site manager electronic audit unit ec4z applications guide … · electronic audit unit ec4z...

12
Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 1 of 12 SITE MANAGER Product Range The EC4Z electronic audit unit is an advanced electronic counters designed to work with standard Gaming and amusement machines. The system is complemented with full site management software. For users with their own site management software the DCM RF Control Centre and the separate DCM Smart Card Utility can be used to output data files of meter readings in an open format for importing into other programmes. Smart Card reader DCM Site Manager Software Reports generated for machines (Takings, float & performance) Consolidated reports for sites and groups of sites. Set-up Of Smart Cards for EC3 units DCM RF Control Centre Interactive control of machines fitted with EC4 counters. Displays & logs alarms from machines. Takes regular counter readings for consolidation in the site manager software EC3 Counters EC4 Counters Manual Readings EC1/EC2 Counters Wireless Router

Upload: others

Post on 11-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 1 of 12

SITE MANAGER

Product Range The EC4Z electronic audit unit is an advanced electronic counters designed to work with standard Gaming and amusement machines. The system is complemented with full site management software. For users with their own site management software the DCM RF Control Centre and the separate DCM Smart Card Utility can be used to output data files of meter readings in an open format for importing into other programmes.

Smart Card reader

DCM Site Manager Software

Reports generated for machines

(Takings, float & performance) Consolidated reports for sites

and groups of sites. Set-up Of Smart Cards for EC3

units

DCM RF Control Centre

Interactive control of machines

fitted with EC4 counters. Displays & logs alarms from

machines. Takes regular counter readings for

consolidation in the site manager software

EC3 Counters EC4 Counters

Manual Readings EC1/EC2 Counters

Wireless Router

Page 2: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 2 of 12

SITE MANAGER

EC3 (Smart Card) Counter The EC3 electronic counter is designed to electronically track cash for audit/security purposes within a machine. The readings can be electronically collected on a Smart Card to eliminate the risk of transcription errors that occur when reading meters manually. The EC3 collects serial data from the gaming machine’s BACTA dataport and also supports six conventional electro-mechanical inputs for use in machines without the dataport. BACTA Counts are collected individually for all Coins, Notes and Tokens IN and OUT as communicated via the dataport. Displayed items are:

Cash In The total value of all coins and notes IN. Cash Out the total value of all coins and notes paid OUT. Cash to Float the total value of all coins IN routed to Hopper. Cash Refill the total value of all coins classified as Cash Refill. Cash Float the total value of all cash float reported by the machine. Notes In the total value of all Notes types (£5 values and above) IN. VTP The count of plays from the BACTA data port H/W 1 - 6 count of pulses on the conventional meter hardware inputs

Additionally, individual coin/note counts are taken from the BACTA data to aid identifying discrepancies. The display of these individual counts may be enabled through the menus. Tokens, if used in the machine are counted as separate total values for IN, OUT, to Float, Refill and Float. Cashbox door and service door opening events are counted to assist in identifying unauthorised access to the machine. A smart card can also be used to set the configuration of the unit.

This guide relates to EC3 software version 3.2. Installation Machine with BACTA Dataport Using connection loom EC3-1 and with the machine power switched OFF, connect the 25 way ‘D’ connector to the BACTA port on the main game board and the 12 way Molex connector to the DCM-EC3 unit. If hardware meters are also required use loom EC3-3. Machine without Dataport Using connection loom EC3-2 and with the machine power switched OFF, hard wire the colour coded wires to the meter or coin pulses to be counted and a 12v DC power source in the machine. A spare counter input can be connected to the cashbox or service door to trigger the “snapshot” of readings when the machine is opened.

Page 3: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 3 of 12

SITE MANAGER

Operation In normal operation the display will scroll through all enabled display items in turn e.g.

dd/mm/yy hh:mm Cash In nnnn

dd/mm/yy hh:mm Cash Out nnnn

Value of “Cash In”

dd/mm/yy hh:mm Token In nnnn

dd/mm/yy hh:mm Csh->Flt nnnn

dd/mm/yy hh:mm Notes In nnnn

dd/mm/yy hh:mm Token Out nnnn

dd/mm/yy hh:mm Tok->Flt nnnn

dd/mm/yy hh:mm Cash Ref nnnn

dd/mm/yy hh:mm Tok Ref nnnn

dd/mm/yy hh:mm Cashbox nnnn

dd/mm/yy hh:mm Service nnnn

dd/mm/yy hh:mm CF Total nnnn

dd/mm/yy hh:mm TF Total nnnn

dd/mm/yy hh:mm H/W x nnnn

dd/mm/yy hh:mm VTP nnnn

Count of Cashbox door opened

Value of “Cash Refill”

Value of “Cash routed to Float”

VTP count

Hardware meter counts (all 6 shown)

Total Value of “Cash Float”

Count : Service door opened

Page 4: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 4 of 12

SITE MANAGER

A “short” press on the Function button will step the display to the next counter name in sequence, the counter value is then displayed for 30 seconds before the normal scrolling continues. A “medium” press on the Function button displays the unit serial number and site code. The EC3 counter features resettable as well as absolute “non-resettable” counters for all items. If the resettable counters are enabled these are added to the display sequence above with their values always shown as 5 digits, prefixed with a “R”. Input pulses on the hardware counter inputs are filtered to prevent noise and fast pulses corrupting the count. The filter value can be changed if required to set the maximum operating rate of the hardware input EC3. The operation rate of the BACTA dataport is controlled by the handshaking within the protocol, however the EC3 should be able to handle 20+ counting messages per second. All counter values and settings are stored in non-volatile EEPROM memory. For security and integrity multiple coded copies of the main counter values are maintained enabling recovery in most cases from single bit or byte data corruption. The counters themselves comprise a “main counter” which is non-resettable and a smaller “resettable” counter which may be cleared through the menus. The main counters are “absolute counts” and cannot be cleared, however they can be set to operate and display as 5, 6 or 7 digit counters:

Digits Count “From” Count “To” (before rolling over back to zero)

5 00000 99999 6 000000 999999 7 0000000 9999999

The resettable counters count in the range 00000 to 49999 before rolling over back to zero.

Main Counter 5, 6, or 7 digit

Resettable Counter Clear from Menu or card

data collection

Input Trigger

Page 5: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 5 of 12

SITE MANAGER

Connections

Pin Signal Loom EC3-1 Wire Colour

Loom EC3-2 Wire Colour

Loom EC3-3 Wire Colour

1 +12V EC3 supply Orange or Red Red Red 2 Counter 6 Common No connection Brown Brown 3 Counter 6 No connection Green Green 4 BACTA_TX Grey No connection Grey 5 BACTA_RX1 Blue No connection White/Black 6 0v EC2 supply return Black Black Black 7 Counter 5 No connection Yellow Yellow 8 Counter 4 No connection Pink Pink 9 Counter 3 No connection White White

10 Counter 2 No connection Violet Violet 11 Counter 1 No connection Blue Blue 12 Counter Common No connection Orange Orange

The EC3-1 loom is 1.5 metres long to connect to a standard data port (25 pin D connector). The EC3-2 loom is 1.0 metres long (Power connections 1.5 metres) with free ends. The EC3-3 loom has a 1.5 metre connection to the dataport and 1.0 metre long free ends.

View looking at connector Pins

Pin 1 Pin

12 Function Button

Page 6: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 6 of 12

SITE MANAGER

Appendix 1 - Specification BACTA Dataport compatible – 1200 baud data rate

Hardware Counter inputs – voltage levels 0v / 12v, auto detecting 0v or 12v common line. Hardware Counter inputs – 390 ohm load between pins 2 and 3, other counters 470 ohm load

to pin 12. (These values allow the correct operation of most meter detect circuits. These inputs can also be driven directly by most coin mechanisms, hoppers etc).

38 non resettable 7 digit and 38 resettable 4½ digit electronic counters

12 way Molex interface connector

2 line by 16 character LCD display with 5mm characters Battery backed real-time clock for date & time stamping meter readings. Battery Life : 10

years. Display scrolls through active counters continuously Single “Function” switch to access a simple set-up menu. Counts held in non volatile EEPROM memory with a life of greater than 1 million counts on

any single counter. For security multiple copies of each count are held to permit error correction.

Power Supply

Voltage: 12v DC nominally (9v – 15 v acceptable) Current: 120mA max supply (plus 30mA pulsed for each hardware counter active)

Operating Temperature +0°C to +45°C Storage Temperature -10°C to +60°C EMC The EC3 module is supplied as a component with no intrinsic function

under the definition of the EU EMC Directive. The complete machine is subject to EMC conformance.

Safety The EC3 is a low voltage device – It is recommended that the power supply

transformer and mains wiring within the machine conforms to a relevant standard such as IEC 950.

Page 7: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 7 of 12

SITE MANAGER

Mechanical Dimensions Appendix 2 - Menu Operation Menus are accessed and controlled with the single “Function” key with the length of press differentiating between tasks:

Function Key Time held ON Action Short press (S) < 1 second Steps to next item in menu

Medium Press (M) >1 second, < 5 seconds Enters the next menu level/ sub menu, or displays /

changes a value Long Press (L)

HOLD until display changes > 5 seconds Enters menus from normal

operation, or exits from the current menu level

If the Function key is not pressed for 15 seconds the menus will exit, one level at a time.

105mm

32mm

72mm Mounting Holes : 2 x 5mm diameter on 95mm pitch

Page 8: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 8 of 12

SITE MANAGER

Top level Menu Map

M

S

S

S

S

M

M

M

M

M

M

M

M

Normal Mode

Menu 3.2

Digits

Short display of software version number

L

Enable

Filter

Configuration

Clear R-Count

S

Set Number of Digits

Counter Enable Sub-menu

Set Filter value

Diagnostics, snapshot etc

Clear resettable Counters

M

M

M

M

Date

Month

Year

Hour

Minute

Set Date, Time and day of week

Day

H/W Snap Select Hardware input (1 –6 or none) to trigger snapshot Select Parallel Inputs to log alarm event in Activity Log (ON/OFF)

Alarm Enable

Page 9: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 9 of 12

SITE MANAGER

Digit Selection Counter Enables

Digits Digits 5

Digits 6

Digits 7

M

M

M

M

L

Enable H/W ON

VTP ON

Token ON

Float ON

Refill ON

L

M

S

S

S

S

S

M - toggles individual counter ON and OFF

Other ON

R-Count ON

S

S

S

Legend – Items displayed: H/W- hardware meters Token- Token totals Float- Cash/Tokens routed to Float Refill- Cash or Token Refill Other- All individual cash counters VTP- Value of Total Play count R-Count- Resettable Counters

Page 10: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 10 of 12

SITE MANAGER

Set Filter Value Configuration

Configuration Diag1 ON

Diag2 OFF

CLR on Snap ON

S

S

S

M

L

Dia1 – display received messages Dia2 – do not use CLR on Snap – clear resettable counters when snapshot taken One-Shot – If ON, takes snapshot of all meter readings on the 1st Cashbox door open event after data collected by card. (If OFF the snapshot data reflects the readings on the most recent opening of the Cashbox door) BACTA Ctrs – if ON, allows BACTA counter data to be collected by smart card. This mode will automatically be enabled if the EC3 unit detects communications via the BACTA dataport. H/W Ctrs – if ON, allows hardware counter data to be collected by smart card. This mode will automatically be enabled if the EC3 unit detects activity on the hardware inputs. GMT/BST – if ON automatically adjusts the clock forward one hour on the last Sunday in March and back one hour on the last Sunday in October.

Filt Filt 15 S – steps between standard values 5, 10, 15, 20, 25 L

M

One-Shot ON

BACTA Ctrs ON

H/W Ctrs ON

GMT/BST ON

Page 11: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 11 of 12

SITE MANAGER

Appendix 3 – Diagnostic Information In normal operation when an input event is detected the counter number/type is displayed on the 2nd line of the LCD with a “+” character. e.g. for a 10p coin inserted : On power up the model and software version number are displayed for a short period of time: Error Messages: Internally the EC3 counter can detect communication errors. If these are detected they are displayed for a short period when the units is powered up and when the menus are entered in the format below, where Exx is the error number followed by the number of occurrences. Please refer these errors to JCA Systems. Appendix 4 – Factory Settings

Digits 7 Filter 10 Counter Values All zero EC3 Serial Number factory set to a unique number Snapshot One-shot mode + clears resettable counters GMT/BST ON H/W Snap None BACTA Ctrs OFF (will automatically configure) H/W Ctrs OFF (will automatically configure)

10p CI+

DCM –EC3 v3.2

EE Error An irrecoverable memory has occurred – try powering off and on again

E01 003

Page 12: SITE MANAGER Electronic Audit Unit EC4Z APPLICATIONS GUIDE … · Electronic Audit Unit EC4Z APPLICATIONS GUIDE V1.0 © 2007 JCA Systems Ltd Page 5 of 12 SITE MANAGER Connections

Electronic Audit Unit EC4Z APPLICATIONS GUIDE

V1.0

© 2007 JCA Systems Ltd Page 12 of 12

SITE MANAGER

Appendix 5 : Collecting Meter Readings from an EC3 unit 1. Create a collection card using either the Site Manager or Smart Card Utility software

packages 2. Collect readings from one or more machines

The display will show Where nnnnn is the record number being written. (A 256K card has capacity for over 100 records, a 64K card can hold a maximum of 34 records). If the card is full, no records will be written and a warning message issued. Wait until the display shows

Before taking the card out, otherwise the data from the meter will not be read completely. 3. Repeat for all machines to be read

Insert card into slot with the gold contacts away from the Display If the Display shows “INVALID CARD” it may be inserted the wrong way round

Writing Record nnnnn

Remove Card