site survey c....sewermain sip sewer inspection point water meter rain water outlet tap gpit grated...
TRANSCRIPT
P.O. Box 1566, Coffs Harbour, NSW 2450
Ph: (02) 66529600 Fax: (02) 66529644
I/ We approve these drawings correct as
Date:
per contract.
OVERHEAD ELECTRICITY
POWER POLEPP1 PHOTO LOCATION & DIRECTION
LEGEND
SEWER MAN HOLE
GASHYDRANT
TELSTRA PIT
WATERMAIN
SEWERMAIN SEWER INSPECTION POINTSIP
WATER METER
RAIN WATER OUTLET
TAP
GRATED PITGPIT
RW
WMBOUNDARY LINE
TOP & TOE OF BANKS
MAJOR CONTOUR LINE
MINOR CONTOUR LINE
TELSTRA LINE
FENCE LINE
TELSTRA PILLARTPIL
NOTE:-
AUTHORITY.
BEEN SURVEYED.
1. BOUNDARIES HAVE BEEN DETERMINED BY
2. SERVICES HAVE BEEN LOCATED ONLY WHERE VISIBLE, PRIOR TO EXCAVATION OR CONSTRUCTION ALL SERVICES ARE TO BE LOCATED BY RELEVANT
PLAN DIMENSIONS ONLY, AND HAVE NOT
4. APPROXIMATE SITE AREA = 738.8m²
3. SPOT LEVELS AND CONTOURS SHOWN HEREON ARE FOR DESIGN PURPOSES ONLY AND ARE TO BE CONFIRMED ON SITE PRIOR TO EXCAVATION OR CONSTRUCTION.
5. DETAILS OF SURVEY ARE CORRECT TO THE DATE SHOWN 02/02/14
TR16034 = TR/HH/DD/SWHERE:
HH = 16m (HEIGHT)
S = 4m (SPREAD - RADIUS)
DD = 0.3m (DIAMETER)TREE CODES
6. DBD UNAVAILABLE AT TIME OF SURVEY DUE TO UNREGISTERED PLAN ALL SERVICES ARE LOCATED BY SURFACE FEATURES ONLY
(C) POSITIVE COVENANT 10.0m WIDE
Issue Date Amendment
Site survey
MAITLAND
C.C.NOTES:
ORIGIN OF LEVELS - ASSUMED------
CONTOUR INTERVAL 1.0m
Electricity
Telephone
Road
Kerb
J/N
Gas
Flood Affected
Footpath
Drawn by
Surveyor
Client
C.C.
5059
LOT
Suburb
Local Auth
Water
Par
SERVICES
Stormwater
Sewerage
UBD ref
5
UNDERGROUND
--
BITUMEN
ROLL
CONTRETE
Check with Council
Checked
Order No
DATE
C.S.
130107/100
09/02/2015
MAITLAND
AVAILABLE
AVAILABLE
DP 1207153
Cnt
Area
on
THORNTON
738.8m²
NORTHUMBERLAND
C.
AVAILABLE
STREET
Surveying Planning Engineering
ABN: 42 110 897 928
THE JUNCTION
(02) 4963 5521(02) 4963 5520
E-mail:
PO Box 853
Phone: Fax:
NSW 2291
S O L U T I O N S
pmentLand Develo
1 09/20/15 INITIAL ISSUE
KINGHAM CIRCUIT
INTEGRITY PROJEX I PTY. LTD
2 22/09/15 ISSUE 2 - RETAINING & RAINWATER TANKS
935
925
3,6
00
6,000
3,0
00
6,020
5,098
10,215
9,0
35
8,9
65
RAINTANK ONCONC. PAD
APPROXLOCATION
RAINTANK ONCONC. PAD
APPROXLOCATION
EXISTINGFENCE TO BE
RETAINED
GROUND MOUNTED CLOTHESLINEAPPROX LOCATION
FIELD GULLIES AS PERENGINEERS DETAIL
600h MAXIMUM STACKERBLOCK RETAINING WALL
WALL MOUNTED CLOTHESLINEAPPROX LOCATION
EXISTING TREESTO BE RETAINED
AS PER COVENANT
PROPOSEDSUBDIVISION LINE
DRIVE GRADIENT
DRIVE GRADIENT
SEWER MANHOLE LID TO BE REPLACEDWITH HEAVY DUTY TYPE CAPABLE OF
SUPPORTING VEHICLE LOADS
400h MAXIMUM STACKERBLOCK RETAINING WALL
IF REQUIRED
DISPLAY HOMEFENCING
PAIR OFUNEQUAL
GATES
400h MAXIMUM STACKERBLOCK RETAINING WALL
IN FRONT OF FENCE
400h MAXIMUM STACKERBLOCK RETAINING WALL
IN FRONT OF FENCE
SAW CUTS TODRIVEWAY AS
REQUIRED
SAW CUTS TODRIVEWAY AS
REQUIRED
RESIDENCE 1APPROX PAD R.L 10.0
APPROX SLAB R.L 10.4(SITE SCRAPE)
RESIDENCE 2APPROX PAD R.L 10.0
APPROX SLAB R.L 10.4(SITE SCRAPE)
10.2
3
10.1
89.
88
9.64
9.41
9.30
9.37
9.53
9.48
9.74
9.81
9.98
9.95
10.1
4
10.2
1
10.3
3
10.3
0
10.1
09.
87
9.58
9.50
9.56
POWER9.65
9.58
9.58
9.66
9.81
9.98
10.3
6
10.3
710
.02
9.81
9.64
9.91
10.0
7
10.3
2
10.2
8
10.2
4
10.1
0
10.0
79.
87
9.97
9.78
9.68
9.82
10.1
3 10.0
0
10°0
5'5
5"
10°1
5'5
0"
100°15'50"
179°2
6'3
0"
0.6
7
18.0
0
43.315
17.6
45
10.00
LP9.61
R.L. 10.00 ASSUMED TOP OF KERBSITE B.M. WHITE
AR
C. 17.7
55
R. 47.0
0
ED
GE
OF
BIT
UM
EN
BA
CK
OF
KE
RB
CR
OW
N O
F R
OA
D
TR
0101
01TR
0101
01
TR
0101
01
TR
0101
01
TR
0101
01
LOT 5DP 1207153
738.8m²
LOT 4
6
G O
V E
R N
M E
N T
R
O A
D
K I N
G H
A M
C
IRC
UIT
(C)
(C)
(C)
(C)
N
SMH9.70
SMH
SMH10.12
WALL SETOUT LINEPA
RA
LLE
L
WA
LL S
ET
OU
T
100°15'50"40.00
CONCRETE DRIVE & PATHWITH DRY SPRAY FINISH
32m2 APPROX
AP
PR
OX
AP
PR
OX
APPROX
APPROX
AP
PR
OX
5000L
5000L
PAVERS29m2 APPROX CONCRETE DRIVE & PATH
WITH DRY SPRAY FINISH59m2 APPROX
WALL SETOUT LINE
2.5% fall2.5% fall
R.L 9.6R.L 10.3
9% fall
2.5% fall3.0% fall
CUT
FILL
9.50
RA
MP
DO
WN
9.71
Site PlanScale 1:200
BASIX NOTES:SITE AREA: 738.8m2
TOTAL ROOF AREA: 372.9m2
UNIT 1:COND AREA: 127.34m2
UN-COND AREA: 65.67m2
LANDSCAPED AREA: 114.8m2
CATCHMENT AREA: 200.8m2
RAINTANK: 5000L CONNECTED TOTOILETS, EXTERNAL TAPS ANDCOLDWATER TAP TO WASHING MACHINEUNIT 2:COND AREA: 140.82m2
UN-COND AREA: 112.61m2
LANDSCAPED AREA: 124.6m2
CATCHMENT AREA: 172.1m2
RAINTANK: 5000L CONNECTED TOTOILETS, EXTERNAL TAPS ANDCOLDWATER TAP TO WASHING MACHINEALL TAPS TO BE 4 STAR RATEDALL TOILETS TO BE 3 STAR RATED
CONSTRUCTIOND.J.B
NOTE:STORMWATER TO ENGINEER DETAIL &LANDSCAPING TO CONSULTANTS DETAIL
R1 SITE: 360.6m2R1: FOOTPRINT: 171.46m2SITE COVERAGE: 47.5%R2 SITE: 378.2m2R2: FOOTPRINT: 158.72m2SITE COVERAGE: 42.0%
NOTE:STORMWATER, WASTE WATER DISPOSAL & METER BOXLOCATIONS TO BE DETERMINED ON SITE.
NOTE:ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS
NOTE:DEVELOPMENT TO COMPLY WITH ACOUSTIC REPORT BY REVERB ACOUSTICS REF: 08-1226-R2 DATED: 02/11/13
NOTE:ENSURE SAWCUTS/KEY JOISTSTO DRIVEWAY AS REQUIRED
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:120, 1:1
2 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERS
AUSTRALIA NSW
®
AREAS: RES 2
1. Lower Living
2. Upper Living
3. Garage
4. Upper Alfres
5. Porch
99.83
71.79
36.36
21.24
2.35
231.57 m2
24-0
6LW
06-1
8F
G
24-18SD
12-0
8LW
24-0
6LW
24-2
4S
D
24-06LW06-21FG 06-18FG
24-0
9LW
24-0
9LW
820
820
24-12 WHITE GLASS
24-14 MIRROR
24-1
8 M
IRR
OR
820
720
720
820
720
24-2
7S
T
24-36ST 720
24-0
9LW
82024-1
5S
D24-2
4S
D24-2
4S
D
820 24-05LW
23-1
8 M
IRR
OR
720820
23-1
8 M
IRR
OR
820
23-14 WHITE GLASS
24-09LW 06-18FG
06-1
5F
G
15-0
6F
G
24-36SD-4
820
820
15-0
6F
G
2.4
x2.7
SE
CT
/ST
EE
L D
OO
R
1200
720 CSD
720 C
SD
2.4
x4.8
SE
CT
ION
AL S
TE
EL D
OO
R
820 CSD
1200
2x820 CSD720 C
SD
720 C
SD
1,7
80
15 90
3,4
20
90 5
109
01,0
00
79070 130250
1,0
20
70
930
70
1,0
20
9015
4,6
90
6001590 8,500 1,710 70 1,020 180 2,720 70 1,620 70 1,630 70 1,320 70 3,730 90
151,510
1590 8,500 90 1,620 70 1,020 90
901,070 1,650 70 1,620 70 3,020 70 950 70 3,620 90
15600
900 4,000 15180
3,320 90 1,00090
600 1,020 70 1,730 20070200
70 1,650 70 1,620 70 3,020 70 95070
53070
3,0209015
4959015
915 90 3,895 15180
3,320 90 1,000 90 3,620 9015
3,540 1590
63070
6,020 9015
1,610
4,900 8,420 3,540 6,930 1,610
615 24,485
1,270 6,650 5,300 6,230 1,000 1,510
90 1,1801590 3,020
90510
90600 2,130 90
155,300
1590 6,020 90
151,000 1,510
1590 3,620 90 1,730 1,000 90 3,420 200
901,420 200
906,020 90
151,000 1,510
1590 2,510 90 1,020 90 1,020 90 1,620 90 3,620 90 1,620 90 6,020 90
151,000 925
135450
4,4101590 3,020
90510
901,020 90 1,620 90
154,000
1590230
701,000 4,250 2,770 90
151,510
1590
5,8
00
90
1,0
00
990
907
0 90
1,0
20
705307
03,0
20
70
930
70
2,0
20
9015
5,8
90
1590
1,9
90
250
1,6
20
70
1,0
20
70
1,9
30
70
3,0
20
9015
5,8
90
135
1,9
45
15907
0 90 15
1,5
70
1590
2,8
45
1590 7
090 1
53,0
90
5,8
90
2,0
80
280
1,5
70
2,9
50
280
3,0
90
16,1
40
1,7
80
15 90
4,0
20
90
1,0
00
9015
885
250
1,0
20
70
1,2
20
70
730
9015
4,6
90
1590
920
140
1,9
60
90
4,0
70
90
610
250
4,7
10
90
620
70
2,3
10
9015
1590
1,9
10
90
1,0
20
90
1,0
20
90 5
509
01,0
20
90
1,9
10
250
4,8
00
900
2,1
00
9015
1590
3,0
20
90
1,6
60
90
3,0
20
907
0 90
7,8
00
9015
900
1,1
80
90
5,7
20
90
890
15
9070 9
04,7
10
18015
2,8
95
9015
900
7,9
70
280
4,8
90
3,9
00
1590
1,6
50
140
1,2
30
90
2,6
90
90
1,2
90
700
250
1,0
20
304
1,6
96
70
1,0
20
70
3,6
20
9015
1,7
80
1590
4,0
20
90
1,0
00
9015
885
250
1,0
20
70
1,2
20
70
1,7
10
90
3,6
20
9015
105
22.525 2
2.5
105
EQ.EQ.
25,100
900
eq. 1,200 1,200 eq.
VELUX 550W x 700L FIXED SKYLIGHT(SQ SET VAULTED OPENING)
SUSPENDEDCONC. SLAB
OVER
WINDOWS TO SIT ON BENCHTOP 915mm A.F.L (FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)
90mm WALLTO CSD
90mm WALLTO CSD
O`HEAD C`BRDS& R`HOOD OVER
CONCEALED CISTERNWALL MOUNTED TOILET
CONCEALEDCISTERN
WALL MOUNTEDTOILET
SQ SET BEAM OVERSEE SECTION DETAIL
PLUMBINGSTACK
PLUMBING STACK (TO BE DISCUSSED)
4x 3000x1200x6mmVERSILUX SHEETS WITH
19x19mm PERIMETER BEAD
6mm
MIN
GLA
ZIN
G T
O D
OO
R/H
I-LI
TE
AS
PE
R A
CO
US
TIC
RE
PO
RT
6mm
MIN
GLA
ZIN
G T
O D
OO
R/H
I-LI
TE
AS
PE
R A
CO
US
TIC
RE
PO
RT
90mm RAKING WALL
GYPROCK SHAFTLINER PARTY WALLSYSTEM (No CSR 360)
10mm SUPERCHEK GYROCK & R2.7SOUND BATTS TO EACH INTERNAL SIDE
(SEE SECTION)
2x 3000x1200x6mm VERSILUX SHEETS ONBATTENS TO UNDERSIDE OF SUSPENDED SLAB VENTED EAVE SHEET
VENTED EAVE SHEET
300mm DROPPEDCEILING FOR A/C
FRAMELESSSHOWER SCREEN
refspace
1650mm
d/wspace
B`BAR
UBO
KITCHEN GARAGE
BED 3
ENTRY
BED 2
900
VA
Nca
b-m
ade
wal
l hun
g
1000x1200
BED 1
900
VA
Nca
b-m
ade
wal
l hun
g
1000x1200
LIVING
ALFRESCO 1
DINING
LINENROBE
RO
BE
PTY
LIN
EN
w/m
spac
e
PORCH
HWD TIMBER DECK
LINEN
WIR
nich
e
nich
e
1000
h x
200w
tile
d bo
x
cutout (see detail)
HWD TIMBER DECK
HWD TIMBERDECK
4x s
helv
es c
ab-m
ade
cab-madeappliance
shelf
RAKED CEILING
cab-
mad
ebe
nch
NO SETDOWN
cornerlessstacker
GARAGENO SETDOWN
BED 3
BED 1
BED 2
1650
mm90
0 V
AN
cab-
mad
ew
all h
ung
ENTRY
BENCH(cab-made)
WIR
1000x1200
1600x1000
PORCHRO
BE
RO
BE
w/mspace
LINEN
LINEN
1500
VA
Nca
b-m
ade
wal
l hun
g
BROOM
200w
x 1
000h
tile
d bo
x
cab-madebench
VOID OVER
UPPOLISHED HARDWOOD STAIRS(center stringer with open risers)
PAVEDAREA
LIGHT COURT VOID OVER
ST
EE
L B
EA
M O
VE
RS
TE
EL
BE
AM
OV
ER
ST
EE
L B
EA
M O
VE
R
no h
ob
no hob
HI-
LIT
E O
VE
RRAKED CEILING
HWD TIMBERDECK
FC SHEETCEILING
FC SHEETCEILING
AIR
CO
N
sq s
et b
ox
no h
ob
no hob
B`H
EA
D (
2400
FR
OM
FF
L)
1200h nib wall
1200h nib wall
hosecock
DP
DPDP
DP
DPDPDP
DP
DP
DP DP DP
DP
DPDPhose cock
PUMP
GAS (instantaneous)
PU
MP
VERSILUX SHEET CEILING
STEP DOWN
angled wall
living/dining
nib
deck
alfrescopost kitchen
linen
pty
nib
wir shr
shr
ens
bath
bath
bath wc
wc
powder robe linen
bed 2
bed 2 hall
hall
robe
entry
bed 3
bed 3
bed 1 courtyard garage
nib
porch
box
bed 3
laundry
bed 2
bed 2post robe bath
halllinen
robe brm nook
wir
nib bed 1
bed 1
light court
ens/linen
ens
stack stairs
garage
garage
garage
entry porch
post
box boxbath
nib
deck
kitchen
living/dining
shr
linen
bed
1
ens
gara
ge
linen
hall
light
cou
rt
hall
stai
rs
post
hall
hall
hall en
try
porc
h
lin/r
obe
vani
tyshr
wc
wal
l uni
t
hall
robe
bed
2/be
d 3
deck
cour
tyar
d
linen
nib
gara
ge
laun
dry
bed
1
stac
k
wir
shrha
ll
bath
bathrobe
bed
2
post
post
bed
3
robe
hall
linen
hall
hall
hall
light
cou
rt
brm
hall
hall
shr
angl
edw
all
dini
ng
dini
ng/k
itche
n
livin
gal
fres
co
isla
nd
linen
hall
ens
bed
1
b'he
ad
pty
deck
post
laun
dry
nib
wc
nib
hall
dini
ng
hosecock
hosecock
(see
det
ail)
box
(RE
MO
TE
)(R
EM
OT
E)
MH
RAKED CEIL
ING
STEEL BEAM OVER IN CEILING
BEAMOVER
BEAM OVER
RA
KIN
G B
EA
M O
VE
R
LINE OF UPPER FLOOR ABOVE
BEAM
OVER
nook
RAKED CEILIN
G
deck
BEAM OVER(IN CEILING)
HARDIGROOVECEILING LINING
HARDIGROOVECEILING LINING
(300w)
SQ
SE
TB
EA
M O
VE
R
BE
AM
OV
ER
(IN
CE
ILIN
G)
06-21LW/FG/LW
2100H
06-21LW/FG/LW
2100H
2100H
06-30LW/FG/LW
2100H
12-15LW/FG
12-15FG/LW 12-15LW/FG
WA
LL M
OU
NT
ED
CLO
TH
ES
LIN
E
party wall length
MBOX
MBOX
entr
y
porc
h
deck
deck
rece
ss
BEAM OVER
lift-off hinge
ALFRESCO 2
2340h
PIV
OT
HI-
LIT
E O
VE
R2340h
PIV
OT
2040h2040h
2040h2040h
2040h
2040h
2040h
2040h
2040h
hosecock
24-2
1S
D(T
EM
PO
RA
RY
)24-2
1S
D(T
EM
PO
RA
RY
)
tow
el r
ail
towel rail
towel rail
tow
el r
ail
Ensuite4.62 m2
Bathroom8.24 m2
Laundry1.21 m2
Bathroom4.64 m2
Powder3.29 m2
Ensuite5.54 m2
Laundry4.17 m2
CAB-MADE WALLUNIT SEE DETAIL
TEMPORARY FRAMEDWALL FOR SALES OFFICE
(TO BE REMOVED AT ALATER DATE)
(instantaneous)GAS
cab-
mad
ew
all u
nit
AREAS: RES 1
1. Living
2. Garage
3. Alfresco 1
4. Porch
136.98
21.66
12.00
1.56
172.20 m2
Floor Plan - NOT TO SCALEScale 1:120
RESIDENCE 1Ext Perimeter: 49.94 l/m(not inc party wall)Kitchen: 4.84 l/mWet Areas: 13.76m2
Raked Ceilings: 70.23m2
Alfresco 1 Deck: 19.1m2
Alfresco 2 Deck: 16.6m2
RESIDENCE 2Lower Ext Perimeter: 38.650 l/m(not inc party wall)Lightwell Perimeter: 5.830 l/m(not inc party wall)Upper Ext Perimeter: 42.840 l/mKitchen: 7.1 l/mWet Areas: 19.8m2
Raked Ceilings: 83.4m2
Timber Deck: 3.2m2
Paved Area: 28.7m2
NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE
NOTE: ALL EXT WALL OUTER FACES TO BE SHEETED WITH 15mm PLY (PRIOR TO CLADDING)& 13mm GYPROCK TO INTERNAL WALL FACE AS PER ACOUSTIC REPORT
NOTE: ALL GLAZED DOORS & WINDOWSTO COMPLY WITH MINIMUM RW RATINGSAS PER ACOUSTIC REPORT
(under-roof)
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
3 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERS
AUSTRALIA NSW
®
24-0
6LW
06-1
8F
G
24-18SD
12-0
8LW
24-0
6LW
24-2
4S
D
24-06LW06-21FG 06-18FG
24-0
9LW
24-0
9LW
820
820
24-12 WHITE GLASS
24-14 MIRROR
24-1
8 M
IRR
OR
820
720
720
820
720
24-2
7S
T
24-36ST 720
24-0
9LW
820
24-1
5S
D24-2
4S
D24-2
4S
D
820 24-05LW
23-1
8 M
IRR
OR
720820
23-1
8 M
IRR
OR
820
23-14 WHITE GLASS
24-09LW 06-18FG
06-1
5F
G
15-0
6F
G24-36SD-4
820
820
15-0
6F
G
2.4
x2.7
SE
CT
/ST
EE
L D
OO
R
1200
720 CSD
720 C
SD
2.4
x4.8
SE
CT
ION
AL S
TE
EL D
OO
R
820 CSD
1200
2x820 CSD
720 C
SD
720 C
SD
VELUX 550W x 700L FIXED SKYLIGHT(SQ SET VAULTED OPENING)
SUSPENDEDCONC. SLAB
OVER
WINDOWS TO SIT ON BENCHTOP 915mm A.F.L (FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)
90mm WALLTO CSD
90mm WALLTO CSD
O`HEAD C`BRDS& R`HOOD OVER
CONCEALED CISTERNWALL MOUNTED TOILET
CONCEALEDCISTERN
WALL MOUNTEDTOILET
SQ SET BEAM OVERSEE SECTION DETAIL
PLUMBINGSTACK
PLUMBING STACK (TO BE DISCUSSED)
4x 3000x1200x6mmVERSILUX SHEETS WITH
19x19mm PERIMETER BEAD
6mm
MIN
GLA
ZIN
G T
O D
OO
R/H
I-LI
TE
AS
PE
R A
CO
US
TIC
RE
PO
RT
6mm
MIN
GLA
ZIN
G T
O D
OO
R/H
I-LI
TE
AS
PE
R A
CO
US
TIC
RE
PO
RT
90mm RAKING WALL
GYPROCK SHAFTLINER PARTY WALLSYSTEM (No CSR 360)
10mm SUPERCHEK GYROCK & R2.7SOUND BATTS TO EACH INTERNAL SIDE
(SEE SECTION)
2x 3000x1200x6mm VERSILUX SHEETS ONBATTENS TO UNDERSIDE OF SUSPENDED SLAB VENTED EAVE SHEET
VENTED EAVE SHEET
300mm DROPPEDCEILING FOR A/C
FRAMELESSSHOWER SCREEN
refspace
1650mm
d/wspace
B`BAR
UBO
KITCHEN GARAGE
BED 3
ENTRY
BED 2
900
VA
Nca
b-m
ade
wal
l hun
g
1000x1200
BED 1
900
VA
Nca
b-m
ade
wal
l hun
g
1000x1200
LIVING
ALFRESCO 1
DINING
LINENROBE
RO
BE
PTY
LIN
EN
w/m
spac
e
PORCH
HWD TIMBER DECK
LINEN
WIR
nich
e
nich
e
1000
h x
200w
tile
d bo
x
cutout (see detail)
HWD TIMBER DECK
HWD TIMBERDECK
4x s
helv
es c
ab-m
ade
cab-madeappliance
shelf
RAKED CEILING
cab-
mad
ebe
nch
NO SETDOWN
cornerlessstacker
GARAGENO SETDOWN
BED 3
BED 1
BED 2
1650
mm90
0 V
AN
cab-
mad
ew
all h
ung
ENTRY
BENCH(cab-made)
WIR
1000x1200
1600x1000
PORCHRO
BE
RO
BE
w/mspace
LINEN
LINEN
1500
VA
Nca
b-m
ade
wal
l hun
g
BROOM
200w
x 1
000h
tile
d bo
x
cab-madebench
VOID OVER
UPPOLISHED HARDWOOD STAIRS(center stringer with open risers)
PAVEDAREA
LIGHT COURT VOID OVER
ST
EE
L B
EA
M O
VE
RS
TE
EL
BE
AM
OV
ER
ST
EE
L B
EA
M O
VE
R
no h
ob
no hob
HI-
LIT
E O
VE
RRAKED CEILING
HWD TIMBERDECK
FC SHEETCEILING
FC SHEETCEILING
AIR
CO
N
sq s
et b
ox
no h
ob
no hob
B`H
EA
D (
2400
FR
OM
FF
L)
1200h nib wall
1200h nib wall
hosecock
DP
DPDP
DP
DPDPDP
DP
DP
DP DP DP
DP
DPDPhose cock
PUMP
GAS (instantaneous)
PU
MP
VERSILUX SHEET CEILING
STEP DOWN
hosecock
hosecock
(see
det
ail)
(RE
MO
TE
)(R
EM
OT
E)
MH
RAKED CEIL
ING
STEEL BEAM OVER IN CEILING
BEAMOVER
BEAM OVER
RA
KIN
G B
EA
M O
VE
R
LINE OF UPPER FLOOR ABOVE
BEAM
OVER
RAKED CEILIN
G
BEAM OVER(IN CEILING)
HARDIGROOVECEILING LINING
HARDIGROOVECEILING LINING
(300w)
SQ
SE
TB
EA
M O
VE
R
BE
AM
OV
ER
(IN
CE
ILIN
G)
06-21LW/FG/LW
2100H
06-21LW/FG/LW
2100H
2100H
06-30LW/FG/LW
2100H
12-15LW/FG
12-15FG/LW 12-15LW/FG
WA
LL M
OU
NT
ED
CLO
TH
ES
LIN
E
MBOX
MBOX
rece
ss
BEAM OVER
lift-off hinge
ALFRESCO 2
2340h
PIV
OT
HI-
LIT
E O
VE
R2340h
PIV
OT
2040h
2040h
2040h2040h
2040h
2040h
2040h
2040h
2040h
hosecock
24-2
1S
D(T
EM
PO
RA
RY
)24-2
1S
D(T
EM
PO
RA
RY
)
tow
el r
ail
towel rail
towel rail
tow
el r
ail
Ensuite4.62 m2
Bathroom8.24 m2
Laundry1.21 m2
Bathroom4.64 m2
Powder3.29 m2
Ensuite5.54 m2
Laundry4.17 m2
CAB-MADE WALLUNIT SEE DETAIL
TEMPORARY FRAMEDWALL FOR SALES OFFICE
(TO BE REMOVED AT ALATER DATE)
(instantaneous)GAS
cab-
mad
ew
all u
nit
900
790
1,0
00
300
1,2
00
300
600
R2 ENSUITE DETAIL R2 BOX DETAIL
200dsq. set box
R2 SHOWER DETAIL
90d niche
polished edgemirror over
200w tiled box
1500 vanity(cab-made)
shwr
1,2
00
1,0
00
1,2
00
300
300 300
550
1,0
00
300
900
cab-made recessed wallunit with mirror fixed to door
R1 CUTOUTDETAIL
cutoutopening
R1 TYPICALSHOWER DETAIL
90d niche
R1 ENS DETAIL
200w tiled box
900 vanity(cab-made)
adj shelf
adj shelf
Ground Floor PlanScale 1:100
NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE
N
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
4 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERSAUSTRALIA NSW
®
06-30 OPENING
06-30FG
06-15FG12-06FG
720
09-06FG
06-30FG
6,740 15180
4,020 9015
4,000 1590230
70910 70 2,020 70 1,680 90
15495
1054,180
90 3,510 15180
9,440 90 4,250
3,600 15180
9,440 9015
3,735 9015
13,340 3,840 600
3,140 3,600 4,320 4,000 5,860 4,180
1590
5,7
10
790
70 130105
1590
5,7
10
9015
990
1590
6,7
00
9015
6,9
10
90
5,7
20
90
1,0
10
5,9
00
1,0
10
1590
5,7
10
990
9015
1590
4,7
10
1,0
00
70
920
90 15
4,7
10
1590
1,0
00
990
9015
4,7
10
1,9
20
280
equal
1,2
00
1,2
00
1,2
00
equal
3,140 3,600 14,180 4,180
900
700
200
600
300
O`HEAD C`BRDS, R`HOOD & 2400hPLASTER BULKHEAD OVER
DUCTED MECHANICALVENTILATION TO BCA REQ
5x 3600x1200x6mmVERSILUX SHEETS WITH
19x19mm PERIMETER BEAD
SQ SET BEAM(SEE DETAIL)
15mm PLY TO START FROM TOP OF LOWERADJOINING UNIT ROOF & CONTINUE UPWARDS
VENTED EAVE SHEET
MIRRORED SPLASHBACK
LIVING
refspace
d/wspace
B`BAR
UBO
DINING
KITCHEN
PTY VOIDhandbasin
ALFRESCO
12-36AW
24-5
4S
T
12-3
6A
W
CONC. TILED RAKED CEILING
RAK
ED C
EILI
NG
1000h WALL
RA
KIN
G B
EA
M O
VE
R
sq s
et b
ox
LIGHT COURTYARD - VOID BELOW
SPREADER SPREADER SPREADER
SPREADER
DP
VERSILUX CEILING
alfresco
alfrescopost
kitchen courtyard
dining/lounge stairs
nibvoidpowderhallstack
livin
g
dini
ng/k
itche
n
alfr
esco
post co
urty
ard
livin
gbo
xst
ack
wc
stai
rs
stai
rsvo
id
(see
det
ail)
p. stack
kitc
hen
LINE OF STOREY BELOW LINE OF STOREY BELOW
LINE OF STOREY BELOW
2100H 2100H
VELUXSKY
LIGHT
courtyard
hosecock
gascock
lift-
off h
inge
m/ospace
a/c ducts Upper Powder1.86 m2
600
790
R2 BOX DETAIL
200dsq. set box
Upper Floor PlanScale 1:100
NOTE: WINDOWS RESTRICTEDAS PER B.C.A 2013
N
NOTE: ALL EXT. & INT. DOOR AND WINDOWHEAD HEIGHTS ARE 2400H (NOM) UNLESSNOTED OTHERWISE
NOTE: ALL EXT WALL OUTER FACES TO BE SHEETED WITH 15mm PLY (PRIOR TO CLADDING)& 13mm GYPROCK TO INTERNAL WALL FACE AS PER ACOUSTIC REPORT
NOTE: ALL GLAZED DOORS & WINDOWSTO COMPLY WITH MINIMUM RW RATINGSAS PER ACOUSTIC REPORT
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
5 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDING
DESIGNERS
AUSTRALIA NSW
®2,7
40
2,7
40
2,1
00
2,1
00
2,1
00
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH
'SCYON' STRIA CLADDINGCOLORBOND ROOF @ 5° PITCH
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH'SCYON' AXON CLADDING
OPENING TO DECK
ALUMINUM ADAPTORTRIM TO ALL LOUVRES
EASYLAP HORIZONTALALUM JOINER STRIP
Finished slab height
Underside of trusses
Finished ground height
Finished floor height
Underside of floor joists
easylap setout from center of windoweasylap setout from center of wall easylap setout from internal cornereasylap setout from ext corner
2,7
40
2,7
40
2,7
40
600
600
450 450
COLORBOND ROOF @ 5° PITCH
'SCYON' STRIA 300h CLADDING
COLORBONDROOF @ 8° PITCH
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH
'SCYON' AXON CLADDING
135x135 STAINEDHWD TIMBER POST
ALUMINUM ADAPTOR TRIM TO ALL LOUVRES
NIB WALL CLAD IN HARDIESEASYLAP WITH TEXTURE COAT FINISH
NIB WALLS CLAD IN HARDIESEASYLAP WITH TEXTURE COAT FINISH
COLORBOND ROOF @ 5° PITCH
Finished slab height
Underside of trusses
Finished ground height
Finished floor height
Underside of floor joists
Finished slab height
Underside of trusses
easylap setout from edge of g/door easylap setout from center of g/door
TEMPORARY FRAMED WALL FOR SALES OFFICE(TO BE REMOVED AT A LATER DATE)
Left ElevationScale 1:100
Front ElevationScale 1:100
NOTE:
THESE DRAWINGS ARE A PICTORIAL INDICATION ONLY,
SOME VARIATION MAY OCCUR ON SITE.
NOTE:
ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS
THERMAL COMFORT COMMITMENTS:
-R 1.0 ANTICON BLANKET TO ROOF
-R 3.0 BATTS TO CEILING
-R 1.0 SISALATION TO EXT. WALLS
-R 2.0 BATTS TO EXT. WALLS
NOTE: ALL GLAZED DOORS & WINDOWS
TO COMPLY WITH MINIMUM RW RATINGS
AS PER ACOUSTIC REPORT
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
6 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDING
DESIGNERSAUSTRALIA NSW
®
2,7
40
2,7
40
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH
WINDOWS TO SIT ON BENCHTOP 915mm A.F.L(FRAME MANUFACTURER TO MAKE SILL HEIGHT 870mm)
ALUMINUM ADAPTORTRIM TO ALL LOUVRES
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH
Finished slab height
Underside of trusses
Finished ground height
Finished floor height
Underside of floor joists
easylap setout from ext corners
easylap setout from ext corner easylap setout from ext corner
easylap setout from center of window
easylap setout from int corner
'SCYON' AXON CLADDINGVELUX FIXED SKYLIGHT RAISED/FRAMED UP
TO 15° AS PER MANUFACTURERS SPEC
2,7
40
2,7
40
2,7
40
450
600
450
COLORBOND ROOF @ 5° PITCH
COLORBOND ROOF @ 8° PITCH
1020h POWDERCOATED ALUMBALUSTRADE WITH S/S WIRE
TO N.C.C. REQUIREMENTS
HARDIES EASYLAP CLADDINGWITH TEXTURE COAT FINISH
RAKING DUMMY BEAM OVER
ALUMINUM ADAPTORTRIM TO ALL LOUVRES
90x90 STAINEDHWD TIMBER POST
'SCYON' AXON CLADDING
VELUX SKLIGHT
Finished slab height
Finished ground height
Underside of trusses
Finished floor height
Underside of floor joists
Finished slab height
Underside of trusses
easylap setout from edge of sliding door
horizontal alum joiner
90x90 GAL STEEL POSTS (UNPAINTED)
Right ElevationScale 1:100
Rear ElevationScale 1:100
NOTE:
THESE DRAWINGS ARE A PICTORIAL INDICATION ONLY,
SOME VARIATION MAY OCCUR ON SITE.
NOTE:
ALL CONSTRUCTION TO BAL 12.5 BUSHFIRE REQUIREMENTS
THERMAL COMFORT COMMITMENTS:
-R 1.0 ANTICON BLANKET TO ROOF
-R 3.0 BATTS TO CEILING
-R 1.0 SISALATION TO EXT. WALLS
-R 2.0 BATTS TO EXT. WALLS
NOTE: ALL GLAZED DOORS & WINDOWS
TO COMPLY WITH MINIMUM RW RATINGS
AS PER ACOUSTIC REPORT
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
7 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERS
AUSTRALIA NSW
®
Electrical - R2
Electrical Item
011257 - Clayton 1lt CeramicPendant-Black
170550 - LEDLUX 3m RibbonII Kit IP65 Warm WH
170565 - 11w LEDLUX VIVID700LM Dim DL - White-WW
190406 - 28w Horizo II mirrorlight - Silver-Frost Glass
2 - Way Light Switch
200026 - Thermalite 3 in 1- 2Lamp - White
200241 - Hellar Round fan-light - SS
210260 - ARTEMIS 58in Fan-Light - Matt Black
210817 - 48in Altitude Eco18w LED - White
3 - Way Light Switch
300866 - LEDLUX FORO4.5w Rec Steplight - White
Datapoint
Dimmer
Double GPO 1050mm AFL
Double GPO 300mm AFL
Double GPO Weather Proof
Flourescent Tube Light
Garage Remote
Phone Point
Sensor
Single GPO 1050mm AFL
Single GPO 1900mm AFL
Single GPO 300mm AFL
Single GPO Weather Proof
Smoke Alarm
TV Point
Wall Light
Symbol
011257
P
170550
170565
190406
2w
200026
200241
210260
210817
3w
300866
D
Dim
WP
Remote
WP
TV
Quantity
3
1
34
2
6
2
1
1
3
3
2
8
14
6
15
2
2
1
1
1
1
2
2
2
2
2
2
Electrical - R1
Electrical Item
011030 - Pentone 3lt PendantAsh-Opal
170565 - 11w LEDLUX VIVID700LM Dim DL - White-WW
190406 - 28w Horizo II mirrorlight - Silver-Frost Glass
2 - Way Light Switch
200026 - Thermalite 3 in 1- 2Lamp - White
210817 - 48in Altitude Eco18w LED - White
Datapoint
Dimmer
Double Fluorescent TubeLight
Double GPO 1050mm AFL
Double GPO 300mm AFL
Garage Remote
Phone Point
Sensor
Single GPO 1050mm AFL
Single GPO 1900mm AFL
Single GPO 300mm AFL
Single GPO Weather Proof
Smoke Alarm
TV Point
Symbol
011030P
170565
190406
2w
200026
210817
D
Dim
Remote
WP
TV
Quantity
1
31
1
2
2
3
2
7
1
7
14
1
1
1
1
2
1
2
2
2
24-0
6LW
06-1
8F
G
24-18SD
12-0
8LW
24-0
6LW
24-2
4S
D
24-06LW06-21FG 06-18FG
24-0
9LW
24-0
9LW
820
820
24-12 WHITE GLASS
24-14 MIRROR
24-1
8 M
IRR
OR
820
720
720
820
720
24-2
7S
T
24-36ST 720
24-0
9LW
820
24-1
5S
D24-2
4S
D24-2
4S
D
820 24-05LW
23-1
8 M
IRR
OR
720820
23-1
8 M
IRR
OR
820
23-14 WHITE GLASS
24-09LW 06-18FG
06-1
5F
G
15-0
6F
G
24-36SD-4
820
820
15-0
6F
G
2.4
x2.7
SE
CT
/ST
EE
L D
OO
R
1200
720 CSD
720 C
SD
2.4
x4.8
SE
CT
ION
AL S
TE
EL D
OO
R
820 CSD
1200
2x820 CSD
720 C
SD
720 C
SD
210817
TV
D
Rem
ote
WP
210817
170565170565
170565
210817
170565
200026
200026
170565
170565
3w
3w
3w
2w2w
170565 170565
170565
170565
170565
TV
DR
em
ote
WP
210817
210817170565
200026
170565
170565170565
210817
170565
170565
170565 170565
200026
2w 2w2w
WPWP
170565
2w2w
170565
DD
TV
170565
170565
170565
170565
170565
170565170565
170565
170565
170565
170565 170565
170565 170565
170565
170565
170565
170565
170565
011030P
190406
Dim
Dim
Dim
Dim
Dim
Dim
Dim
170565
170565
Dim
170565
190406
170565
170565
170565
170565
Dim
Dim
Dim Dim
Dim Dim
Dim
190406
170565
170565
170565
170565
170565
170565
170565
WP
D
D
D
D
D
D
SINGLE GPO FORD/W & R/HOOD
DOUBLE GPO FOR FUTURE NBN
DOUBLE GPO FOR FUTURE NBN
SINGLE EXT GPOFOR PUMP
SIN
GLE
EX
T G
PO
FO
R P
UM
P
SINGLE EXT GPOFOR HWS
SINGLE EXT GPOFOR HWS
refspace
1650mm
d/wspace
1000x1200
1000x1200
LINENROBE
RO
BE
PTY
LIN
EN
w/m
spac
e
LINEN
WIR
nich
e
nich
e
1000
h x
200w
tile
d bo
x
cutout (see detail)
4x s
helv
es c
ab-m
ade
cab-madeappliance
shelf
cab-
mad
ebe
nch
1650
mm
RO
BE
RO
BE
w/mspace
ST
EE
L B
EA
M O
VE
R
AIR
CO
N
no h
ob
no hob
hosecock
DP
DPDP
DP
DPDPDPD
P
DP
DP DP DP
DP
DPDPhose cock
PUMP
GAS (instantaneous)
PU
MP
hosecock
hosecock
(RE
MO
TE
)(R
EM
OT
E)
MH
STEEL BEAM OVER IN CEILING
BEAMOVER
BEAM OVER
RA
KIN
G B
EA
M O
VE
R
(300w)
SQ
SE
TB
EA
M O
VE
R
BE
AM
OV
ER
(IN
CE
ILIN
G)
06-21LW/FG/LW
2100H
06-21LW/FG/LW
2100H
2100H
06-30LW/FG/LW
12-15LW/FG
12-15FG/LW 12-15LW/FG
MBOX
MBOX
2040h
2040h
2040h2040h
2040h
2040h
2040h
2040h
2040h
hosecock
24-2
1S
D(T
EM
PO
RA
RY
)24-2
1S
D(T
EM
PO
RA
RY
)
(instantaneous)GAS
cab-
mad
ew
all u
nit
Lower Electrical PlanScale 1:100
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
8 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERSAUSTRALIA NSW
®
06-30 OPENING
06-30FG
06-15FG12-06FG
720
09-06FG
06-30FG
2w
TV
170565
170565
200241
170565
170565
170565 170565
170565 170565
170565
170565
Dim
011257
P
011257
P
011257
P
DimDim
Dim
Dim
WP
170550
170565
300866 300866Dim
210260
DUCTED MECHANICALVENTILATION TO BCA REQ
SINGLE GPO FORM/O, D/W & R/HOOD
refspace
d/wspace
PTY12-36AW
24-5
4S
T
12-3
6A
W
SPREADER SPREADER SPREADER
SPREADER
DP
p. stack
LINE OF STOREY BELOW LINE OF STOREY BELOW
LINE OF STOREY BELOW
2100H 2100H
hosecock
gascock
lift-
off h
inge
m/ospace
a/c ducts
Upper Electrical PlanScale 1:100
NOTE:
SEE LOWER FLOOR ELECTRICAL PLAN FOR QUANTITIES
BASIX NOTES:
ENERGY - ALL DWELLINGS:
*HWS: GAS INSTANTANEOUS - 5 STAR RATED
*COOKTOP/OVEN: ELECTRIC
*RANGEHOOD: NON DUCTED, MAN SWITCH
*LIGHTING: LED LIGHTS TO KITCHEN, LIVING & HALLWAYS
*CLOTHESLINE: EXTERNAL
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:1, 1:100
9 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERSAUSTRALIA NSW
®
Legend:Carpet:Vinyl Plank:Tiles:
Floor coverings approx area`s (not inc waste) - R2
Type
R2 Lo Ext Tiles
R2 Lower Carpet
R2 Up Ext Tiles
R2 Low V/Plank
R2 Upp V/Plank
Approx Area (m2)
3.63
41.02
20.56
31.40
54.57
24-0
6LW
06-1
8F
G
24-18SD
12-0
8LW
24-0
6LW
24-2
4S
D
24-06LW06-21FG 06-18FG
24-0
9LW
24-0
9LW
820
820
24-12 WHITE GLASS
24-14 MIRROR
24-1
8 M
IRR
OR
820
720
720
820
720
24-2
7S
T
24-36ST 720
24-0
9LW
820
24-1
5S
D24-2
4S
D24-2
4S
D
820 24-05LW
23-1
8 M
IRR
OR
720820
23-1
8 M
IRR
OR
820
23-14 WHITE GLASS
24-09LW 06-18FG
06-1
5F
G
15-0
6F
G24-36SD-4
820
820
15-0
6F
G
2.4
x2.7
SE
CT
/ST
EE
L D
OO
R
1200
720 CSD
720 C
SD
2.4
x4.8
SE
CT
ION
AL S
TE
EL D
OO
R
820 CSD
1200
2x820 CSD
720 C
SD
720 C
SD
refspace
1650mm
d/wspace
1000x1200
1000x1200
LINENROBE
RO
BE
PTY
LIN
EN
w/m
spac
e
LINEN
WIR
nich
e
nich
e
1000
h x
200w
tile
d bo
x
cutout (see detail)4x
she
lves
cab
-mad
e
cab-madeappliance
shelf
cab-
mad
ebe
nch
1650
mm
RO
BE
RO
BE
w/mspace
ST
EE
L B
EA
M O
VE
R
AIR
CO
N
no h
ob
no hob
hosecock
DP
DPDP
DP
DPDPDP
DP
DP
DP DP DP
DP
DPDPhose cock
PUMP
GAS (instantaneous)
PU
MP
hosecock
hosecock
(RE
MO
TE
)(R
EM
OT
E)
MH
STEEL BEAM OVER IN CEILING
BEAMOVER
BEAM OVER
RA
KIN
G B
EA
M O
VE
R
(300w)
SQ
SE
TB
EA
M O
VE
R
BE
AM
OV
ER
(IN
CE
ILIN
G)
06-21LW/FG/LW
2100H
06-21LW/FG/LW
2100H
2100H
06-30LW/FG/LW
12-15LW/FG
12-15FG/LW 12-15LW/FG
MBOX
MBOX
2040h
2040h
2040h2040h
2040h
2040h
2040h
2040h
2040h
hosecock
24-2
1S
D(T
EM
PO
RA
RY
)24-2
1S
D(T
EM
PO
RA
RY
)
(instantaneous)GAS
cab-
mad
ew
all u
nit
Floor coverings approx area`s (not inc waste) - R1
Type
R1 Carpet
R1 Tiles
Approx Area (m2)
38.93
70.86
Lower Floor Coverings PlanScale 1:100
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
10 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDINGDESIGNERSAUSTRALIA NSW
®
Legend:Carpet:Vinyl Plank:Tiles:
06-30 OPENING
06-30FG
06-15FG12-06FG
720
09-06FG
06-30FG
refspace
d/wspace
PTY12-36AW
24-5
4S
T
12-3
6A
W
SPREADER SPREADER SPREADER
SPREADER
DP
p. stack
LINE OF STOREY BELOW LINE OF STOREY BELOW
LINE OF STOREY BELOW
2100H 2100H
hosecock
gascock
lift-
off h
inge
m/ospace
a/c ducts
Upper Floor Coverings PlanScale 1:100
NOTE:SEE LOWER FLOOR COVERINGS PLAN FOR QUANTITIES
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
11 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDING
DESIGNERS
AUSTRALIA NSW
®
915 90 3,895
5,8
90
2,0
80
280
1,5
70
2,9
50
280
3,0
90
3,140 90 1,180 6,650 5,300 6,230 1,000 925135
450
1,7
80
1,3
45
1,7
80
1,1
80
90
5,7
20
90
890
280
2,0
40
600
2,2
50
2,8
95
9015
900
7,9
70
280
4,8
90
3,0
00
900
135
1,9
45
600
910 600
1,510
1,510
300600 4,000 8,420 3,540 6,930 1,610
24,991
16,1
40
600 24,500
2,835
3,1
25
3,5
25
2,615
3,2
15
1,6
60
1,620 6,215
2,1
25
805
885
1,3
40
2,0
20
980 1,930 105
2,035
3,0
00
3,8
15
75 4,000
3,140 1,270 18,180 1,000 1,510
2,730 105
4,410
900 580 3,420 220
220
2,5
20
480
810
90
5,610 7,905
600
2045
1,683 45 1,683 4520
65
1,5
27
1,5
27
1,5
27
45
20 90
1,4
37
90
1,4
37
90
1,4
37
90
20 45
1,3
70
45
1,3
70
45
960
45
90 1,507 90 1,507 90 1,507 9020
65
1,3
90
1,4
18
983
45
1,597 1,597 1,596 65
20 90
1,3
50
9020
90
895
90
895
9020
2090 1,310 90
700
400
385
2,4
60
450
1,5
00
455
2,4
50 190 3,620 190
2,4
50
1,0
40
4,6
90
220w x 20dREBATE FOR
STACKING DOOR 130w x 20dREBATE FOR
SLIDING DOOR
130w x 20dREBATE FOR
SLIDING DOOR`S
OUTLINE OF SUSPENDED CONC.SLAB & STEEL BEAM OVER
PLUMBING STACKPLUMBING STACK
100mm SETDOWN WITH FALL TOFIELD GULLY AS PER ENGINEERING
130w x 20d REBATEFOR SLIDING DOOR
END BEARER SPACED20mm FROM SLAB EDGE
END BEARER SPACED20mm FROM SLAB EDGE
END BEARER SPACED20mm FROM SLAB EDGE
END BEARER SPACED20mm FROM SLAB EDGE
ALLOW PLUMBINGTO KITCH. BENCH
PAD FOR A/C ATREBATE HEIGHT
PAD FOR PUMP ATREBATE HEIGHT
PAD FOR PUMP ATREBATE HEIGHT
35mm SETDOWNTO WET AREA
35mmSETDOWN
TO WETAREA
35mm SETDOWNTO WET AREA
35mmSETDOWN TO
WET AREA
35m
m S
ET
DO
WN
TO
WE
T A
RE
A
TOTAL SLAB AREA: 300.2m2
TIMBER DECK
TIMBER DECK
TIMBER DECK
TIMBER DECK
c/l c/l
c/l
c/l
Slab PlanScale 1:100
DECK - END BEARERS140x45 MGP10 TREATED PINE ON HALF STIRRUP POST ANCHOR (BEARER LENGTHS MUST BE CONTINUOUS OVER TWO SPANS WHERE APPLICABLE)DECK JOISTS140x45 MGP10 TREATED PINE IN-LINE WITH BEARERS & SUPPORTED BY JOIST HANGERS ENSURE TERMITE BARRIER
Owners:Job Address: Integrity Projex I Pty.Ltd.
CONSTRUCTIOND.J.B
Lot 5, Kingham Circuit, Thornton.
Drawn:
Date:
Job Number:
Type:
Scale:
Page:
1:50
12 / 14Custom
130107
6/04/2017
DJB Issue:SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566, COFFS HARBOUR NSW, 2450 - PHONE NO. (02) 6652 9600 - FAX NO. (02) 6652 9644
Owners signatures confirm these plans are approved as a representation of what is to be built. Items not included in these plans & attached specification are deemed not to be included in the contract: I / We approve these plans.
INTEGRITYNEW HOMES
Changing my world
®
NOTE:- These plans are copyright in whole & in part to Integrity Projex I Pty. Ltd. & may not be used or reproduced without written permission
BUILDINGDESIGNERS
AUSTRALIA NSW
450
600
450
METAL BATTENS@ 900mm cts
PREFABRICATED TIMBERFRAMES TO MANUFACTURER'S
SPECIFICATIONS
10mm PLASTERBOARDTO CEILINGS
PREFABRICATED TIMBER ROOF TRUSSES @ 8° PITCH.600mm MAX. CENTRES WITH BRACING OF TRUSSES
ALSO TO MANUFACTURER'S SPECIFICATIONS
SMART JOIST RAFTERS @ 5° PITCH.600mm MAX. CENTRES TO TILLINGS SPECIFICATIONS
CONCRETE SLAB
SMART JOIST FLOOR450mm MAX. CENTRES TOTILLINGS SPECIFICATIONS
UNDER SLABMOISTURE BARRIER
WATER PROOFEXPOSED
SLAB EDGE ASREQUIRED
RAKED CEILING
450mm EAVEWITH4.5mm
HARDIFLEX
COLORBOND ROOFING FIXED TOMANUFACTURER'S SPECIFICATIONS
GYPROCK SHAFT LINER PARTY WALL SYSTEMTO CONTINUE TO UNDERSIDE OF ROOFINGAS PER MANUFACTURERS SPECIFICATION
55mm ANTICON BLANKET OVER ROOF BATTENS
R2.0 BATTS TO EXT WALLS
R3.0 BATTSTO CEILINGS
HARDIES CLADDINGS ASPER ELEVATIONS WITH
15mm PLY TO ALL EXTERNALWALLS (BEHIND CLADDINGS)AS PER ACOUSTIC REPORT
13mm GYPROCK TOEXTERNAL WALL AS
PER ACOUSTIC REPORT
GYPROCK SHAFTLINER PARTYWALL SYSTEM (No CSR 360)
10mm SUPERCHEK GYROCK &R2.7 SOUND BATTS TO EACH
INTERNAL SIDE
BULKHEADOVER KITCHEN
COLORBOND ROOF (PITCH VARIES)2740 WALL HEIGHTS - 'H' SOIL CLASSIFICATION
POD POD POD POD POD POD POD POD POD POD POD POD POD
KITCHEN LAYOUT SEEMANUFACTURERS.
DETAIL
REFER TO ENGINEER'S REPORTFOR FOOTING & SLAB DETAILS
2340h INTERNAL DOORS
TERMITE BARRIER TO AS 3660 PARTS 1,2 & 3.INSTALLED AS PER MANUFACTURERS SPECIFICATIONS
SectionScale 1:50
Owners:Job Address: Integrity Projex I Pty.Ltd.
CONSTRUCTIOND.J.B
Lot 5, Kingham Circuit, Thornton.
Drawn:
Date:
Job Number:
Type:
Scale:
Page: 13 / 14Custom
130107
6/04/2017
DJB Issue:SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566, COFFS HARBOUR NSW, 2450 - PHONE NO. (02) 6652 9600 - FAX NO. (02) 6652 9644
Owners signatures confirm these plans are approved as a representation of what is to be built. Items not included in these plans & attached specification are deemed not to be included in the contract: I / We approve these plans.
INTEGRITYNEW HOMES
Changing my world
®
NOTE:- These plans are copyright in whole & in part to Integrity Projex I Pty. Ltd. & may not be used or reproduced without written permission
BUILDING
DESIGNERS
AUSTRALIA NSW
SMART JOIST FLOOR450mm MAX. CENTRES TOTILLINGS SPECIFICATIONS
13mm GYPROCK TOEXTERNAL WALL AS
PER ACOUSTIC REPORT
METAL BATTENS@ 900mm cts
SMART JOIST RAFTERS @ 5° PITCH.600mm MAX. CENTRES TO TILLINGS SPECIFICATIONS55mm ANTICON BLANKET OVER ROOF BATTENS
CONCRETE SLAB
SQ SET BEAM
RAKED CEILINGRAKED CEILING
HARDIES CLADDINGS ASPER ELEVATIONS WITH
15mm PLY TO ALL EXTERNALWALLS (BEHIND CLADDINGS)AS PER ACOUSTIC REPORT
SUSPENDED CONC. SLABTO ENG DETAIL
POD PODPODPODPODPODPOD POD PODPODPODPOD
REFER TO ENGINEER'S REPORTFOR FOOTING & SLAB DETAILS
TERMITE BARRIER TO AS 3660 PARTS 1,2 & 3.INSTALLED AS PER MANUFACTURERS SPECIFICATIONS
UNDER SLABMOISTURE BARRIER
SectionScale 1:60
Lot 5, Kingham Circuit,
Thornton.
Integrity Projex I Pty.Ltd.
DJB
6/04/2017
130107
Custom
1:100
14 / 14
CONSTRUCTION
D.J.B
Date:
Page:
Issue:
Type:
Scale:
Job Number:
Drawn:
Owners:
Job Address:
SIGNATURE
SIGNATURE
DATE
DATE
HEAD OFFICE: PO BOX 1566,
COFFS HARBOUR NSW, 2450
PHONE NO. (02) 6652 9600
FAX NO. (02) 6652 9644
Owners signatures confirm these plans are
approved as a representation of what is to be
built. Items not included in these plans &
attached specification are deemed not to be
included in the contract:
I / We approve these plans.
NOTE:- These plans are copyright in whole & in part
to Integrity Projex I Pty. Ltd. & may not be used or
reproduced without written permission
INTEGRITYNEW HOMES
Changing my world
BUILDING
DESIGNERS
AUSTRALIA NSW
®
8° R
OO
F P
ITC
H
8° R
OO
F P
ITC
H
8° R
OO
F P
ITC
H
8° R
OO
F P
ITC
H
5° R
OO
F P
ITC
H
5° R
OO
FP
ITC
H
5° R
OO
FP
ITC
H
UPPER FLOOR OVER
VOID
UPPER FLOOR
5° R
OO
F P
ITC
H
5° R
OO
FP
ITC
H
Roof PlanScale 1:100