skf multilog on-line system imx-m12-147619/brochure en skf multilog imx-m.pdf · skf multilog imx-m...

16
SKF Multilog On-line System IMx-M State of the art solution for protecting and enhancing the reliability of your critical machinery The SKF Multilog On-line System IMx-M is the latest addition to the current generation of powerful, cost effective solutions suitable for a variety of applications. Together with SKF @ptitude Monitoring Suite software, the SKF Multilog IMx-M can provide a com- plete system for initiation of machinery Key features Machine protection 19 inch rack format Meets the intent of API 670 Up to 64 analog inputs (dynamic and static) per rack Up to 32 digital/speed inputs per rack Up to 96 relay outputs per rack Multiple transducer types Radial vibration, position, temperature TSI measurements (absolute shaft vibra- tion, eccentricity, and complementary dif- ferential expansion) Simultaneous measurement of all input channels Redundant Modbus RTU communications Buffered outputs front and rear Local status indication and display Flexible voting logic Machine condition monitoring Independent of machine protection DC to 40 kHz Overall level and vector processing Spectrum with up to 6 400 line resolution Transient and steady-state data capture Multi-parameter gating SKF Acceleration Enveloping Adaptive alarm levels Data buffering in non-volatile memory Fully supported by SKF @ptitude Moni- toring Suite shutdown, early fault detection and diagno- sis. In addition, the SKF Multilog IMx-M sys- tem provides automated advice for correct- ing existing or impending conditions which can affect machine reliability, availability and performance.

Upload: others

Post on 26-Feb-2020

20 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

SKF Multilog On-line System IMx-M State of the art solution for protecting and enhancing the reliability of your critical machinery

The SKF Multilog On-line System IMx-M is the latest addition to the current generation of powerful, cost effective solutions suitable for a variety of applications. Together with SKF @ptitude Monitoring Suite software, the SKF Multilog IMx-M can provide a com-plete system for initiation of machinery

Key features

Machine protection19 inch rack format•Meets the intent of API 670•Up to 64 analog inputs (dynamic and •static) per rackUp to 32 digital/speed inputs per rack•Up to 96 relay outputs per rack•Multiple transducer types•Radial vibration, position, temperature•TSI measurements (absolute shaft vibra-•tion, eccentricity, and complementary dif-ferential expansion)Simultaneous measurement of all input •channelsRedundant Modbus RTU communications•Buffered outputs front and rear•Local status indication and display•Flexible voting logic•

Machine condition monitoringIndependent of machine protection•DC to 40 kHz•Overall level and vector processing•Spectrum with up to 6 400 line resolution•Transient and steady-state data capture•Multi-parameter gating•SKF Acceleration Enveloping•Adaptive alarm levels•Data buffering in non-volatile memory•Fully supported by SKF • @ptitude Moni-toring Suite

shutdown, early fault detection and diagno-sis. In addition, the SKF Multilog IMx-M sys-tem provides automated advice for correct-ing existing or impending conditions which can affect machine reliability, availability and performance.

Page 2: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Power supplies, 90 to 264 V AC1 Single or dual redundant. Each power supply alone may power a fully loaded rack.

Protection I/O module2 Supports multiple transducer types and performs signal process-ing for alarm generation.

16 dynamic channels and eight digital inputs. Segregation of input channel processing such that any single circuit failure can-not affect more than two channels.

Relay module3 32 electro-mechanical relays with configurable logic assigned to any channel in the 19 inch rack, LEDs indicators and relay status.

CPU module4 Parallel data-acquisition of dynamic data for machinery analysis and diagnostics independent of protection function. Also provides user interface and TCP/IP communications.

SKF Multilog IMx-M system overview – front view

1 3

4

6

7

8

55

2

9

1

8

16 channel CPU and I/O pair5 Consisting of a 16 channel Protection I/O Module and 16 channel condition monitoring CPU Module. Up to four pairs per 19 inch rack. Configuration shown is maximum – 64 channels with 96 relays.

LED Indication6 Each channel provides LED color for status alarms – Alert, Danger and Transducer OK. Module OK indication.

Front buffered outputs7 Three BNC connectors on Protection I/O Module front provide direct access buf-fered transducer signals. Channel assignment using keypad on CPU Module. Ideal for use with portable data analyzers (two channels + phase).

USB ports8 For direct configuration of CPU and I/O pair.

Local user interface9 CPU Module provides channel value and alarm status bargraph display for any two channels, selectable by the keypad. Communi-cations and System OK indication LEDs.

2

Page 3: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

SKF Multilog IMx-M system overview – rear view

CPU and I/O pairs1 maximum four pairs per rack

Relay modules2 maximum three modules per rack

Power supply and ground connections3 maximum two modules per rack

Redundant AC power feeds4

Relay outputs5 for machine protection

Status relays6 for circuit fault and disarm indication

Ethernet connections to condition monitoring with internal 7 switchFor convenient interconnection of CPU Modules with external network. Each CPU Module has an individual TCP/IP address.

Redundant RS 485 communications8 Two separate RS 485 lines (L1, L2) provide redundant connec-

tions to DCS. No single protection module failure or removal will affect DCS communications with other modules.

12

13

1 1 1 1 2 2 2 3

5

5

5 46

14

7

8

9

10

11 11

Disarm9 activation by contact closure

Digital field inputs10 Sensor types include, but not limited to:

Eddy current probes (phase reference and speed)•TTL inputs for speed•Logical inputs•

Analog field inputs11 Sensor types include, but not limited to:

Eddy current probes (radial vibration, position)•Accelerometers and velocity sensors•Temperature RTD (Pt 100)•Process variables (4 to 20 mA)•DC voltage•

4 to 20 mA outputs12 16 recorder outputs, assignable to monitored channel variables

(one output per channel)

Rear analog buffered outputs13 for connection to external multi-channel data analyzers

Digital buffered outputs14 re-transmission of tachometer signal to other systems

3

Page 4: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

CMON 200719 inch rack with backplane

System modules, components and technical data

CMON 2007 19 inch rack with backplane • († page 4)CMON 2102 Machine protection • I / O module († page 6)CMON 2103 Condition monitoring CPU module • († page 8)CMON 2109 Relay module • († page 10)CMON 2202 Power supply module • († page 11)

Key featuresStandard 19 inch rack mounted•Standard 6U height•Robust aluminium design•

The 19 inch rack enclosure contains the electronics of the SKF Multilog IMx-M.

Each rack holds up to four I/O cards, four CPU cards, three relay cards and up to two redundant power supplies. The rack has a back-plane providing electric interconnection between CPU cards, I/O cards, relay cards and power supplies. All cards are inserted from the front side of the rack. On the rack rear, there are termination boards for each card set.

Technical data

BackplaneTwo slots for power supplies•Four slots, each for one protection I/O module and one CPU •module (always mounted in pairs)Three slots for relay cards•Screw terminals, RJ45 and D-sub connectors on rear of unit•Redundant power bus to protection I/O modules, total eight per •rack

Physical19 inch rack mounted, 6U high•Dimensions:•

Height: 266 mm – (10.47 in.)Width: 482 mm – (18.98 in.)Depth: 240 mm – (9.45 in.)

Weight (bare rack): 3,5 kg • (123 oz.)

EnvironmentalTemperature range: –20 to +65 °C • (–4 to +149 °F)Humidity: 95% Relative humidity (non-condensing)•

CertificationsIEC 61010-2: 2010•IEC 61010-1: 2001•CAN/CSA 22.2, no. 61010-1, 2• nd EditionUL 61010-1, 2• nd EditionAS 61010-1: 2003•

4

Page 5: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Con

Link1

E t h e r n e t

Act1

Link2

Act2

Ready

S T A T U S

I M x -M

C P U

V1V2V3V4

P o w e r S u pply

V1V2V3V4

P o w e r S u pply R e la y R e la yR e la y

D ig it a l O u t pu t

R A W O u t pu t 2

R A W O u t pu t 1

R S 4 8 5

1

Circuit

Trip

Disarm

Fault

Multiply

Config

C O M M O N

A N A L O G

2

4

6

8

1 0

1 2

D I G /S P D

1

3

5

7

2

4

6

8

2

1

3

5

7

9

1 1

1 3

1 5

1 4

1 6

I /O

Con

Link1

E t h e r n e t

Act1

Link2

Act2

Ready

S T A T U S

I M x -M

C P U

D ig it a l O u t pu t

R A W O u t pu t 2

R A W O u t pu t 1

R S 4 8 5

1

Circuit

Trip

Disarm

Fault

Multiply

Config

C O M M O N

A N A L O G

2

4

6

8

1 0

1 2

D I G /S P D

1

3

5

7

2

4

6

8

2

1

3

5

7

9

1 1

1 3

1 5

1 4

1 6

I /O

Con

Link1

E t h e r n e t

Act1

Link2

Act2

Ready

S T A T U S

I M x -M

C P U

D ig it a l O u t pu t

R A W O u t pu t 2

R A W O u t pu t 1

R S 4 8 5

1

Circuit

Trip

Disarm

Fault

Multiply

Config

C O M M O N

A N A L O G

2

4

6

8

1 0

1 2

D I G /S P D

1

3

5

7

2

4

6

8

2

1

3

5

7

9

1 1

1 3

1 5

1 4

1 6

I /O

Con

Link1

E th e r n e t

Act1

Link2

Act2

Ready

S T A T U S

I M x -M

C P U

D ig it a l O u t pu t

R A W O u t pu t 2

R A W O u t pu t 1

R S 4 8 5

1

Circuit

Trip

Disarm

Fault

Multiply

Config

C O M M O N

A N A L O G

2

4

6

8

1 0

1 2

D I G /S P D

1

3

5

7

2

4

6

8

2

1

3

5

7

9

1 1

1 3

1 5

1 4

1 6

I /O

CMON 2007 Rack dimensions

27,8 mm (1.1 in.) 426,7 mm

(16.8 in.)

265,9 mm (10.5 in.)

190,5 mm (7.5 in.)

27,8 mm (1.1 in.)

435,8 mm (17.2 in.)

213 mm (8.4 in.)

14 mm (0.6 in.) 213 mm

(8.4 in.)

5

Page 6: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

CMON 2102Machine protection I/O module

Key featuresMeets the intent of API 670•Multiple transducer types•RTD temperature (Pt 100)•Radial vibration, position, temperature•TSI functions (absolute shaft vibration, •eccentricity, complementary differential expansion)Simultaneous measurement of all chan-•nelsRedundant Modbus RTU communications•Buffered outputs front and rear•Local status Indication and display•Alarm evaluation and response within •100 msFlexible voting logic•

The CMON 2102 Machine protection I/O module accepts a variety of sensor inputs. Signals such as acceleration, velocity and displacement or other parameters are easily adopted. Each input can be configured for standard accelerometers, velocity sensors, proximity probes, 4 to 20 mA or ±25 V. All channels are processed in parallel.

In addition to the analog channels, eight digital channels may be used for measuring speed or digital status.

The design prevents a single circuit failure from affecting more than two measurement channels, and it is possible to detect and indicate circuit failure. All channel pairs are independent, and can be configured for redundancy. Each channel has indicators for alarm/shutdown and it is possible to manu-ally bypass alarm and shutdown (alert/dan-ger) functionality. The system provides remote reset of latching alarm/shutdown conditions.

Technical data

Physical19 inch rack mounted•Size: 6U high, 4TE wide•Weight: 0,5 kg • (18 oz.)

EnvironmentalTemperature range: –20 to +65 °C •(–4 to +149 °F)Humidity: 95% Relative humidity (non-•condensing)

Input board

Analog inputs16 analog differential inputs (8 can be •used for RTD’s)Individual ±24 V transducer power, maxi-•mum 40 mA/channelPower supply for standard accelerometers •(8 mA constant current) for each channelInput range: ±25 V•Impedance: >100 kΩ•

Digital inputs8 digital Opto isolated inputs with +24 V •sensor power, maximum 40 mA/channel (TTL two-wire tachometers, three-wire tachometers, pulse, etc.). Available –24 V DC power for eddy current probes on 4 inputs.

Outputs16 rear analog buffered outputs•8 rear digital buffered outputs•Two analog buffered outputs (at front, •user selectable)One digital buffered output (at front, user •selectable)Single 4 to 20 mA output per channel•

ProcessingOverall level processing•Radial vibration (mils, microns) peak to •peakAcceleration (g’s) 0 to peak, rms•Velocity (ips, mm/sec) 0 to peak, rms•Position (mils, mm)•Temperature (°C, °F)•TSI functions (absolute shaft vibration, •eccentricity, complementary differential expansion)

InterfaceUSB service interface•RS 485, Modbus, redundant•

MiscellaneousCE certified according to EN61000-6-4•

6

Page 7: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

CMON 2102 Machine protection I/O module

D ig it a l O u t pu t

R A W O u t pu t 2

R A W O u t pu t 1

R S 4 8 5

1

Circuit

Trip

Disarm

Fault

Multiply

Config

C O M M O N

A N A L O G

2

4

6

8

1 0

1 2

D I G /S P D

1

3

5

7

2

4

6

8

2

1

3

5

7

9

1 1

1 3

1 5

1 4

1 6

I /O

Front view of I/O board Rear view of CPU – I/O slot

Modulestatus LED

Channelstatus LED

RedundantRS 485 LEDs

USB port for configuration of protection part

Analog buffered outputs

Digital buffered outputs

Analog transducer inputs

Digital inputs

Digitalbuffered outputs

RedundantRS 485(protection)

Analog transducer inputs

Analog buffered outputs

4 to 20 mA outputs

Digital inputs

Statusrelays

Disarm

7

Page 8: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Key features – machine condition monitoring

Independent of machine protection•DC to 40 kHz•Overall level and vector processing•FFT up to • 6 400 line resolutionTransient and steady-state data capture•Multi-parameter gating•SKF Acceleration Enveloping•Adaptive alarm levels•Data buffering in nonvolatile memory•Fully supported by SKF @ptitude Moni-•toring Suite

The CPU module for the SKF Multilog IMx-M offers data acquisition for condition moni-toring purposes, and is independent of the machinery protection function. It acquires and processes data from all channels simul-taneously and in parallel. This allows for multiple advanced signal analysis methods to be employed. Several measurement points can be connected to each channel signal and individual conditions for warning and alarm may be set for each point. These conditions can be based on fixed frequencies and/or speed-following frequencies (includ-ing harmonics). For each measurement point, multiple conditions can be applied – such as warning and alarm levels may be controlled by machine speed or load. A built-in hardware diagnostic system continuously checks all sensors, cabling and electronics for any faults, signal interruption, shortcuts or power failure. Any malfunction can be set to trigger an alert alarm. In the case of sys-tem power failure, the system will automati-cally restart when the power returns.

Technical data

Physical19 inch rack mounted•Size: 6U high, 8TE wide•Weight: 0,6 kg • (21 oz.)

EnvironmentalTemperature range: –20 to +65 °C •(–4 to +149 °F)Humidity: 95% Relative humidity (non-•condensing)

CMON 2103Condition monitoring processing (CPU) module

Analog measurement24-bit AD conversion enables •continuous transient capture (no gain or AC/DC switching neces-sary)True simultaneous sampling of all •16 channels (no multiplexing)Simultaneous sampling of differ-•ent channels with different sam-pling ratesFrequency range: From DC to •40 kHzDynamic range: 120 dB•Signal to noise ratio: 90 dB•Cross-talk rejection: 100 dB•Accuracy amplitude: ±2%, phase •±3° (up to 100 Hz)

Digital measurementFrequency range: 0.1 Hz to •7.5 kHzAccuracy frequency: 0.01%•Pulse counting•

Signal processing – condition monitoring

Time waveform•Vector analysis with circular •alarmsFFT: 100 to • 6 400 linesSKF Acceleration Enveloping•Integration/differentiation in fre-•quency domainWindow function: Hanning•Mathematical expressions•Dynamic alarm levels, active •range determined on multiple parametersData storage on time, event or •alarm conditionData buffering in flash memory when •communication link is downDetection of sensor and cable fault•Watchdog and self testing•

Protection LCD and keypadSet-up menu•Bargraph•Buffered output front selection•Channel values•

InterfaceEthernet: 10/100 Mbit RJ45, TCP/IP•Built-in two port data switch, 10/100 •Base-TUSB service interface•RS 485, Modbus•

MiscellaneousCE certified according to • EN61000-6-4

8

Page 9: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

CMON 2103 Condition monitoring processing (CPU) module

Con

Link1

E t h e r n e t

Act1

Link2

Act2

Ready

S T A T U S

I M x -M

C P U

Front view of CPU board Rear view of CPU – I/O slot

Modulestatus LED

Local displayselection keypad

Ethernetconnectionstatus LEDs

USB port forconditionmonitoringconfiguration

Local display:Bargraph•Buffered •output front selectionChannel values•

RS 485 forconditionmonitoringdata

Ethernetconnections

9

Page 10: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Key features – machine protection

32 relays per module (28 SPDT, 4 DPDT)•Up to three modules per rack•Software configurable•Flexible relay assignment•On board voting logic•Voting across protection • I/O modulesRedundant operation•Normally open/normally closed•Normally energized/de-energized (user-•selectable)Latching/non-latching•

Each CMON 2109 Machine protection relay module has 32 relays, for a maximum of 96 relays per 19 inch rack. All channels can access all relays.

The relay module is software configurable, with no need for DIP switch settings. Relay log-ic is flexible AND/OR/MAJORITy voting.

CMON 2109Relay module

Technical data

Relay specificationMaximum switching capacity: Up to •60 V DC, 30 V RMS/42.4 V peakMaximum switching current: 2A•Mechanical endurance: Typical 10• 8 opera-tionsElectrical endurance: Minimum 10• 5 oper-ations at maximum ratingCategory of protection: Hermetically •sealed (RT V)

Physical19 inch rack mounted•Size: 6U high, 4TE wide •Weight: 0,4 kg • (14.11 oz.)

EnvironmentalTemperature range: –20 to +65 °C •(–4 to +149 °F)Humidity: 95% Relative humidity (non-•condensing)

MiscellaneousCE certified according to • EN61000-6-4

CMON 2109 Relay module

R e la y

Front view ofRelay board

Rear view ofRelay slot

RelaystatusLEDs

ModulestatusLED

Relaycontactson D-subconnectors

10

Page 11: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Key featuresFour individual LED status indicators (one •per I/O / CPU slotSupports power supply redundancy•

The CMON 2202 supplies power to the vari-ous modules in the SKF Multilog IMx-M rack. The power supply accepts AC (90 to 264 V). A single power supply can support a fully loaded rack. A second power supply can provide redundancy.

Technical data

Physical19 inch rack mounted•Size: 6U high, 12TE wide•Weight: 1,6 kg • (56.44 oz.)

EnvironmentalTemperature range: –20 to +65 °C •(–4 to +149 °F)Humidity: 95% Relative humidity (non-•condensing)

CMON 2202Power supply module

Power supply90 to 264 V AC, 47 to 63 Hz input voltage•Maximum power consumption: 300 W•Redundant option, individual main termi-•nal

MiscellaneousCE certified according to • EN61000-6-4

CMON 2202 Power supply module

V1V2V3V4

P o w e r S u pply

Front and rear views of Power Supply Unit

Future usePowerpresenceindicator LEDs

Instrumentground/protectionground

RedundantAC powerfeed forpowersupplyunit 1

RedundantAC powerfeed forpowersupplyunit 2

11

Page 12: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Scalable plantwide solutions for machinery monitoring

Typical non-hazardous area installation

SKF offers comprehensive solutions for protection and condition monitoring of all classes of rotating machinery, encompassing a variety of architectures that can be scaled to optimize functionality with respect to total installed cost.

SKF Multilog On-line System IMx-MProvides a 19 inch rack format solution that is located in a non-haz-ardous area such as an instrument or control room. The SKF Multi-log IMx-M combines high functionality with high channel density, which leads to lower requirements for a cabinet and associated infrastructure.

SKF Multilog On-line System DMxAPI 670 compliant in a distributed field I/O format solution, located on the machine skid in the hazardous area. The SKF Multilog DMx combines a high functionality in a small physical package that greatly reduces field cable, and almost eliminates the need for instrument room cabinets.

SKF Multilog On-line System IMx-SA multi-channel, on-line condition monitoring device suitable for field installation in non-hazardous areas. The SKF Multilog IMx-S provides fully automated monitoring and analysis capabilities and is best suited for semi-critical and balance of plant equipment.

SKF MultilogIMx-M

(API 670)

SKFMultilogIMx-S

SKFMultilog

DMx(API 670)

RS 485

4 to20 mA

SKF Machine ConditionTransmitters (MCT)

Main turbo-alternator sets Boiler feed pumps ID / FD fansOn-line

process data

SKF Remote ConditionMonitoring Centers

Internet

Reliabilityserver

DistributedControlSystem (DCS)OPC server

Reliabilityworkstations

SKF @ptitude Monitoring SuiteSKF @ptitude Decision Support

Ethernet Ethernet

Redundant RS 485

4 to 20 mA

Relay Outputs

DistributedControlSystem

SKF Microlog

Plant Information Network (PIN)

Redundant RS 485

Plant Control Network (PCN)

12

Page 13: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Scalable plantwide solutions for machinery monitoring

Typical hazardous area installation

SKF Machine Condition Transmitters (MCT)Provides a range of simple single-point devices for providing tradi-tional 4 to 20 mA signals to the plant control system and basic machine trip functionality.

SKF Microlog AnalyzerSKF Microlog portable instruments offer a comprehensive range of predictive maintenance tools.

SKF @ptitude Monitoring SuitePredictive maintenance software platform that brings all data from field instruments together for processing into actionable information regarding equipment reliability. The package provides the database for complex dynamic vibration data, and provides plots and tools for the experienced analyst. SKF @ptitide Decision Support is a data reduction engine and knowledge base for automating much of the analysis process. In addition, the cloud/server architecture allows for remote diagnostic services.

SKF Remote ConditionMonitoring Centers

Internet

Reliabilityserver

DistributedControlSystem (DCS)OPC server

Reliabilityworkstations

SKF MultilogIMx-M

(API 670)

SKFMultilogIMx-S

SKF @ptitude Monitoring SuiteSKF @ptitude Decision Support

SKFMultilog

DMx(API 670)

RS 485

4 to20 mA

SKF Microlog

SKF Machine ConditionTransmitters (MCT)

Critical machines Balance of plants

On-lineprocess

data

Safe areaSafearea

Critical machines Semi-critical machines Balance of plants

ATEX Zone 1 and NEC Class I Division 1

Plant Information Network (PIN)

Safety barrier Safety barrier Safety barrier Safety barrier Safety barrier

ATEX Zone 2 and NEC Class I Division 2

Ethernet Ethernet

Redundant RS 485

4 to 20 mA

Relay Outputs

DistributedControlSystem

Plant Control Network (PCN)

Redundant RS 485

13

Page 14: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Analytical tools from SKF @ptitude Monitoring Suite software

SKF @ptitude Monitoring Suite allows your operations, maintenance and reliability staff to view data from different sources using the same application and communicate information to other depart-ments in a customizable format.

SKF @ptitude Monitoring Suite integrates the range of SKF on-line and off-line data collection devices into one enterprise-wide software platform.

SKF @ptitude Monitoring Suite is a comprehensive software solu-tion with powerful diagnostic and analytical capabilities. SKF @ptitude Monitoring Suite provides fast, efficient and reliable stor-age, analysis, and retrieval of complex asset information and makes the information accessible throughout your organization. SKF @ptitude Monitoring Suite easily scales to your specific needs, whether it is operator inspection rounds, condition monitoring data collection or in-depth vibration analysis and expert advice.

Cascade plot.Topology plot.

Orbit plot.Bode plot.

14

Page 15: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

Transducer systems

Eddy current probe systemsSKF offers a full range of API 670 compliant non-contacting dis-placement sensors (Eddy current probes) for use in critical machin-ery, including models with NEC and ATEX agency approvals.

CMSS 65 / CMSS 665 series, 5 mm eddy probe system5 mm tip diameter, 2 mm (80 mil) measurement range•5 m system length•CMSS 65 Eddy current probe •CMSS 665 Driver•CMSS 958 Extension cable•

CMSS 68 / CMSS 668 series, 8 mm eddy probe system8 mm tip diameter, 2,3 mm (90 mil) measurement range•5 m or 10 m system lengths•CMSS 68 Eddy current probe •CMSS 668 Driver•CMSS 958 Extension cable•

Accelerometers and velocity sensorsSKF offers a full range of piezoelectric casing vibration sensors, including models with NEC and ATEX agency approvals.

General purpose industrial accelerometers CMSS 2100 Top exit, industrial accelerometer •CMSS 2200 Low profile, side exit, industrial accelerometer •CMSS 2106 High temperature, top exit, industrial accelerometer •CMSS 2207 High temperature, low profile, side exit, industrial •accelerometerCMSS 793V Piezoelectric industrial velocity sensor•

Agency approved accelerometers*CMSS 786A-IS and CMSS 786A-D2 CSA and ATEX approved, •intrinsically safe, general purpose, top exit, industrial accelero-meter CMSS 787A-IS and CMSS 787A-D2 CSA and ATEX approved, •intrinsically safe, general purpose, low profile, side exit, industrial accelerometer CMSS 793-CA CSA approved, intrinsically safe, general purpose, •top exit, industrial accelerometer CMSS 793-EE ATEX approved, intrinsically safe, general purpose, •top exit, industrial accelerometerCMSS 793-FM Factory Mutual approved, intrinsically safe, gen-•eral purpose, top exit, industrial accelerometerCMSS 797-EE ATEX approved, intrinsically safe, general purpose, •low profile, ring mode, industrial accelerometer

Installation must conform to hazardous area requirements when used in this *environment.

15

Page 16: SKF Multilog On-line System IMx-M12-147619/Brochure EN SKF Multilog IMx-M.pdf · SKF Multilog IMx-M system overview – rear view 1 CPU and I/O pairs maximum four pairs per rack 2

skf.com

Please contact: SKFCondition Monitoring Center – LuleåAurorum 30, SE-977 75 · Luleå, SwedenTel: +46 (0)920 758 00 · Fax: +46 (0)920 134 40Web Site: www.skf.com/cm

® SKF, @PTITUDE, MICROLOG and MULTILOG are registered trademarks of the SKF Group.

All other trademarks are the property of their respective owners.

© SKF Group 2012The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior writ-ten permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the informa-tion contained herein. SKF reserves the right to alter any part of this publication without prior notice.

PUB CM/P8 11416/1 EN · February 2012

Bearings and unitsSeals Lubrication

systems

Mechatronics Services

The Power of Knowledge Engineering

Drawing on five areas of competence and application-specific expertise amassed over more than 100 years, SKF brings innovative solutions to OEMs and production facilities in every major industry world-wide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics (combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D computer modelling to advanced condition monitoring and reliability and asset management systems. A global presence provides SKF customers uniform quality standards and worldwide product availability.

Ordering informationSKF Multilog On-line System IMx-M components:

CMON 2007:• 19 inch rack enclosure including backplane and power terminal cardCMON 2102:• Machine protection I/O module including terminal card (maximum four per rack)CMON 2103:• Condition monitoring processing (CPU) module (one per CMON 2102)CMON 2109:• Relay module and terminal card (one per CMON 2102 and maximum three per rack)CMON 2202:• Power supply unit (maximum two per rack)