Page 1: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

Slit lamp excellenceProven quality for optimum performance

Page 2: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

2 3

// ExcEllEncE MadE By carl ZEiss

Meeting eye care demands with competence

Carl Zeiss has been meeting highest eye care demands with precision engineering and optics for more than 160 years. In 1912, Carl Zeiss developed the first slit lamp together with the Swedish ophthalmologist and Nobel laureate Allvar Gullstrand. Since then, generations of leading eye care professionals have played a key role in helping us perfect this unique eye examination and therapy technology. The result? Premium slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss.

1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre for Sight, Corneoplastic Unit & Eye Bank,

Queen Victoria Hospital, East Grinstead, UK

2) By courtesy of Prof. Dr. med. Thomas Kohnen, Ophthalmology Clinic, Hospital of the Johann Wolfgang Goethe

University Frankfurt am Main, Frankfurt, Germany

3) By courtesy of Prof. Dr. med. Jürgen Strobel, Eye Clinic of the Friedrich Schiller University Jena, Jena, Germany

Glistenings in an IOL1 Structures in direct focal illumination3

Iris-fixated phakic IOL2 Deep anterior lamellar keratoplasty (DALK)1

Page 3: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

SL 120The all-rounder for outstanding performance

SL 115 Classic

As a highly powerful and versatile slit lamp, the SL 120 provides superb support for anterior segment, vitreous and fundus assessments. Sharp images with excellent detail resolution and high contrast enable visualization of finest structures.

Adjustment flexibility

The system's precision image supports a variety of adjustment options such as slit

image rotation, letting you focus directly on to the object of interest. Its compact

and simple design allows short working distances and easy access to the patient's

eyes. What's more, all slit lamp examinations can be performed with one hand.

Features at a glance

• Slit images with high-contrast resolution and detail for reliable examinations and

contact lens fittings

• Single-hand operation for precise and intuitive ergonomics

• Integrated power supply for immediate plug-and-play readiness

• Integrated swing-in yellow filter for fluorescence examinations and contact

lens fittings

• Stereo microscope with 3 magnification steps

• Super high-eyepoint eyepieces offer eyeglass wearers excellent working

convenience

• Large illuminated field for superb view of the entire anterior segment

• Filters to increase the contrast in red-free observation and fluorescence

• Integrated UV and IR filter in compliance with ISO 10939

• Imaging solutions* for convenient documentation

• AT 020 applanation tonometer* for precise intraocular pressure measurements

* Option SL 120

SL 115 ClassicFocus on the essentials

The SL 115 Classic is a solid performer among slit lamps offering outstanding optical performance at an attractive price. Its ease of use during routine examinations and contact lens fittings enables quick, simple and convenient eye diagnostics.

// Optical prEcisiOn MadE By carl ZEiss

Slit image adaptability

Slit decentration enables more precise examinations of low-contrast findings such

as corneal scars and better after-cataract diagnosis. Also, the slit image width and

length can be continuously adapted to the size of the anomaly.

Features at a glance

• Excellent optical transmission with high resolution and contrast for best observation

• Single-hand operation and ergonomic design for comfortable body posture throughout

the procedure

• Optimized ease of use through quick action brake and easy-grip controls

• Stereo microscope with 5 magnification steps, choice of parallel or

convergent tube

• Super high-eyepoint eyepieces for eyeglass wearers

• Large illuminated field for superb view of the entire anterior segment

• Imaging solutions* for convenient documentation

• Two types of applanation tonometers* for precise intraocular pressure measurements

• Coagulation laser attachment via VISULINK® 532/U*

• Tiltable prism head* for reduced reflections during contact lens examinations and

better peripheral observation of the posterior segment

* Option

Page 4: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

7

Maximum information

Crisp, highly detailed images provide a wealth of information.

Superb optical transmission enables examinations with reduced

light exposure and greater patient comfort. A stereo microscope

with 5 magnification steps, large field of view and super high-eye-

point eyepieces also offers eyeglass wearers an outstanding image.

Convenient operation

All system adjustments can be conveniently performed with both

hands. The slit position can be rotated to the object of interest

or decentered for contrast enhancement and better detection of

fine corneal lesions. Also, the prism head* can be tilted up to 20

degrees to reduce reflections during contact lens examinations

and for better chamber angle and fundus observation. Intuitive

operation is provided by the joystick and quick-action brake. The

optional ACCENTO® ergo tube* supports a comfortable working

position to prevent neck strain.

The SL 130 slit lamp is a premium instrument for the complete range of diagnostic and laser treatment applications. With its high-quality optics, intuitive handling and special features, it is designed to deliver reliable performance for many years to come.

* Option

SL 130Premium optics from diagnosis to laser therapy

Application flexibility

SL 130 can be fitted with a VISULINK® 532/U* laser link for laser coagulations.

Choose between two different applanation tonometers* for precise intraocular

pressure measurements.

Digital documentation

Optional imaging solutions enable digital documentation of slit images, while the

DigiCam illuminator* ensures homogeneous illumination of the slit area. An additional

beam splitter allows easy connection of co-observation devices as well as camera

and video equipment.

Features at a glance

• Crisp, high-resolution images for the complete range of slit lamp applications

• Ideal handling for laser application and contact glass examinations due to

convenient single-hand operation from both sides of the slit projector

• Ergonomic design for comfortable body posture throughout the procedure

• Accurate and intuitive system operation for precise length, width and rotated slit

image adjustment

• Stereo microscope with 5 magnification steps, tiltable prism head* up to 20 degrees

for better peripheral observation of the posterior segment

• Optimized ease of use through quick action brake and triple slit for fast examinations

• Imaging solutions* for convenient documentation

• Choice of two applanation tonometers* for precise intraocular pressure

measurements

• ACCENTO ergo tube* for comfortable working posture with minimum neck strain

• Coagulation laser attachment via VISULINK 532/U*

// cOnVEniEncE MadE By carl ZEiss

SL 130

Page 5: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

8 9

// OphthalMic sOlutiOns MadE By carl ZEiss

The moment innovation and passion lead to the best vision for your patient. This is the moment we work for.

Page 6: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

10 11

SL 115 Classic Slit Lamp SL 120 Slit Lamp SL 130 Slit Lamp

Magnification 8x, 12x, 20x with 10x eyepieces 5x, 8x, 12x, 20x, 32x with 10x eyepieces6x, 10x, 16x, 25x, 40x with 12.5x eyepieces

5x, 8x, 12x, 20x, 32x with 10x eyepieces6x, 10x, 16x, 25x, 40x with 12.5x eyepieces

Field of view diameter

25 … 10 mm 40 … 6 mm with 10x eyepieces 31 … 5 mm with 12.5x eyepieces

40 … 6 mm with 10x eyepieces 31 … 5 mm with 12.5x eyepieces

Eyepiece magnification

Super high-eyepoint eyepieces 10x compensation of ametropia ±8 D

Optionally 10x or 12.5x super high-eyepoint eyepieces, compensation of ametropia ±8 D

Optionally 10x or 12.5x super high-eyepoint eyepieces, compensation of ametropia ±8 D

Width of slit image Continuous from 0 to 14 mm Continuous from 0 to 14 mm Continuous from 0 to 14 mm; display 1 / 2 / 5 / 10 mm

Length of slit image In steps 0.5 / 3.5 / 8 / 14 mm; continuous 1 … 14 mm

In steps 0.3 / 3.5 / 8 / 14 mm;continuous 1 … 6 mm

In steps 0.3 / 2.5 / 3.5 / 7 / 10 / 14 mm; triple slit

Rotation of slit image

Continuous ±90° Continuous ±90° Continuous ±90°

Decentration of slit image

±4° horizontally, click stop at 0°

±4° horizontally, click stop at 0°

±4° horizontally, click stop at 0°

Swivel range of slit projector

180°, scale for angular difference; click stop at 0°

180°, scale for angular difference;click stops at –10° / 0° / +10°

180°, scale for angular difference; click stops at –10° / 0° / +10°

Angle of incidence 0° 0°; 0° … 20° tiltable with tiltable prism head*

0° … 20° tiltable

Filters Blue, green (red-free), swing-in; heat-reflecting filter, permanently integrated; diffusing screen, swing-in; barrier filter (yellow)

Blue, green (red-free), swing-in; heat-reflecting filter, permanently integrated; diffusing screen, swing-in

Blue, green (red-free), grey, swing-in; heat-reflecting filter, permanently integrated; diffusing screen, swing-in

Free working distance exit prism/ patient’s eye

73 mm2.9 in

65 mm2.5 in

66 mm2.6 in

Travel of instrument base

30 mm (vertical), 1.2 in (vertical), 110 mm (lateral), 4.3 in (lateral), 90 mm (axial) 3.5 in (axial)

30 mm (vertical), 1.2 in (vertical), 110 mm (lateral), 4.3 in (lateral), 90 mm (axial) 3.5 in (axial)

30 mm (vertical), 1.2 in (vertical), 110 mm (lateral), 4.3 in (lateral), 90 mm (axial) 3.5 in (axial)

Vertical travel of headrest

59 mm2.3 in

59 mm2.3 in

59 mm2.3 in

Projection illumination

6 V / 10 W halogen lamp 6 V / 20 W halogen lamp 6 V / 20 W halogen lamp

Brightness Continuously adjustable Continuously adjustable Continuously adjustable

Rated voltage 100 … 240 V ±10%, self-sensing, 50 / 60 Hz

100 … 240 V ±10%, self-sensing, 50 / 60 Hz

100 … 240 V ±10%, self-sensing, 50 / 60 Hz

Weight Basic instrument 9.75 kg (21.49 lbs)headrest 1.25 kg (2.76 lbs)

Basic instrument 9.75 kg (21.49 lbs)headrest 1.25 kg (2.76 lbs)

Basic instrument 9.85 kg (21.72 lbs)headrest 1.25 kg (2.76 lbs)

Dimensions of basic instrument (W x H x D)

300 mm x 430 mm x 355 mm11.8 in x 16.9 in x 13.9 in

300 mm x 430 mm x 355 mm11.8 in x 16.9 in x 13.9 in

300 mm x 430 mm x 355 mm11.8 in x 16.9 in x 13.9 in

Selection of optional accessories*

Documentation Imaging solutions available Imaging solutions available Imaging solutions available

Applanation tonometer

AT 020 appalanation tonometer AT 020 applanation tonometer, AT 030 applanation tonometer

AT 020 applanation tonometer, AT 030 applanation tonometer

Tube Parallel tube, convergent tube

Parallel tube, convergent tube

Eyepiece 10x eyepiece for length and angle measurement

10x eyepiece for length and angle measurement; 10x or 12.5x eyepieces

10x eyepiece for length and angle measurements; 10x or 12.5x eyepieces

Ergonomics Fixation light ACCENTO® ergo tube (can only be used in combination with an additional accessory like beam splitter); fixation light

ACCENTO ergo tube; fixation light

Laser attachment VISULINK® 532/U VISULINK 532/U

* For the full range of slit lamp accessories, please contact your local Carl Zeiss sales representative.

Technical Data

// patiEnt carE MadE By carl ZEiss

Page 7: Slit lamp excellence - BSCRS...slit lamp quality and reliability – the SL 115 Classic, SL 120 and SL 130 from Carl Zeiss. 1) By courtesy of Sheraz Daya, MD FACP FACS FRCS(Ed), Centre

Publ

icat

ion

No:

000

000-

1990

-224

SL

I.415

2 Pr

inte

d in

Ger

man

y CZ

-II/2

012

The

cont

ents

of t

he b

roch

ure

may

diff

er fr

om th

e cu

rrent

sta

tus

of a

ppro

val o

f the

pro

duct

in y

our c

ount

ry. P

leas

e co

ntac

t our

regi

onal

repr

esen

tativ

e fo

r mor

e in

form

atio

n.Su

bjec

t to

chan

ge in

des

ign

and

scop

e of

del

iver

y an

d as

a re

sult

of o

ngoi

ng te

chni

cal d

evel

opm

ent.

ACCE

NTO

and

VIS

ULIN

K ar

e ei

ther

trad

emar

ks o

r reg

ister

ed tr

adem

arks

of

Carl

Zeiss

Med

itec

AG in

Ger

man

y an

d/or

oth

er c

ount

ries.

Prin

ted

on e

lem

enta

l chl

orin

e-fre

e bl

each

ed p

aper

201

2 by

Car

l Zei

ss M

edite

c AG

. All

copy

right

s re

serv

ed.

Carl Zeiss Meditec AG Goeschwitzer Strasse 51–5207745 JenaGermanywww.meditec.zeiss.com/slitlampswww.meditec.zeiss.com/contacts

Your local contact:

ArgentinaCarl Zeiss Argentina S.A.Calle Nahuel Huapi 4015 / 25C1430 BCO Buenos AiresArgentinaPhone: +54 11 45 45 66 [email protected]

AustraliaCarl Zeiss Pty Ltd Tenancy Office 4, Level 1 40-52 Talavera Road North Ryde NSW 2113 AustraliaPhone: +61 2 9020 [email protected]

AustriaCarl Zeiss GmbHLaxenburger Str. 21100 ViennaAustriaPhone: +43 1 79 51 [email protected]

BelgiumCarl Zeiss NV-SAIkaroslaan 491930 ZaventemBelgiumPhone: + 32 2 719 39 [email protected]

BrazilCarl Zeiss do Brasil Ltda.Av. Naçoes Unidas, 21711CEP04795-100 São PauloBrazilPhone: +55 11 5693 [email protected]

CanadaCarl Zeiss Canada Ltd.45 Valleybrook DriveToronto, ON M3B 2S6CanadaPhone: +1 800 387 [email protected]

ChinaCarl Zeiss Shanghai Co. Ltd.1/f., Ke Yuan Building11 Ri Yin Nan RoadWaigaoqiao Free Trade Zone2005 Yang Gao Bei RoadShanghai 200131ChinaPhone: +86 21 5048 17 [email protected]

Czech RepublicCarl Zeiss spol. s.r.o.Radlická 14/3201150 00 Prague 5Czech RepublicPhone: +420 233 101 [email protected]

FranceCarl Zeiss Meditec France SAS60, route de Sartrouville78230 Le PecqFrancePhone: +33 1 34 80 21 [email protected]

GermanyCarl Zeiss Meditec VG mbHCarl-Zeiss-Strasse 2273447 OberkochenGermanyPhone: +49 7364 20 [email protected] Ophthalmology:Phone: +49 800 470 50 [email protected]

Hong KongCarl Zeiss Far East Co. Ltd.Units 11-12. 25/FTower 2, Ever Gain PlazaNo. 88 Container Port RoadKwai ChungHong KongPhone: +852 2332 [email protected]

IndiaCarl Zeiss India Pvt. Ltd.22. Kensington RoadUlsoorBangalore 560 008IndiaPhone: +91 80 2557 88 [email protected]

ItalyCarl Zeiss S.p.A.Viale delle Industrie 2020020 Arese (Milan)ItalyPhone: +39 02 93773 [email protected]

JapanCarl Zeiss Meditec Japan Co. Ltd.Shinjuku KuTokyo 160-000322 Honchio-ChoJapanOphthalmic instruments:Phone: +81 3 33 55 [email protected] instruments:Phone: +81 3 33 55 [email protected]

MalaysiaCarl Zeiss Sdn Bhd.Lot2, Jalan 243/51 A46100 Petaling JayaSelangor Darul EhsanMalaysiaPhone: +60 3 7877 50 [email protected]

MexicoCarl Zeiss de México S.A. de C.V.Avenida Miguel Angel de Quevedo 49604010 Mexico CityMexicoPhone: +52 55 59 99 [email protected]

NetherlandsCarl Zeiss B.V.Trapezium 300Postbus 3103364 DL SliedrechtNetherlandsPhone: +31 184 43 34 [email protected]

New ZealandCarl Zeiss (N.Z.) Ltd.15B Paramount DriveP.O. Box 121 - 1001Henderson, Auckland 0650New ZealandPhone: +64 9 838 [email protected]

PolandCarl Zeiss sp. Z o.o.ul. Lopuszanska 3202-220 WarsawPolandPhone: +48 22 858 [email protected]

SingaporeCarl Zeiss Ptd. Ltd.50 Kaki Bukit PlaceSingapore 415926SingaporePhone: +65 6741 [email protected]

South AfricaCarl Zeiss (Pty.) Ltd.363 Oak AvenueFerndaleRandburg 2194South AfricaPhone: +27 11 886 [email protected]

South KoreaCarl Zeiss Co. Ltd.Seoul 121-828Mapo-gu141-1, Sangsu-dong2F, BR Elitel Bldg.South KoreaPhone: +82 2 3140 [email protected]

SpainCarl Zeiss Meditec Iberia S.A.U.Ronda de Poniente, 15Tres Cantos28760 MadridSpainPhone: +34 91 203 37 [email protected]

SwedenCarl Zeiss ABTegeluddsvaegen 7610254 StockholmSwedenPhone: +46 84 59 25 [email protected]

SwitzerlandCarl Zeiss AGFeldbachstrasse 818714 FeldbachSwitzerlandPhone: +41 55 254 [email protected]

ThailandCarl Zeiss ThailandFloor 8, Thosapol Land Building 2230 Ratchadapisek RoadHuaykwang, Bangkok 10310ThailandPhone: +66 2 2 74 06 [email protected]

United KingdomCarl Zeiss Ltd.15-20 Woodfield RoadWelwyn Garden CityHertfordshire, AL7 1JQUnited KingdomPhone: +44 1707 [email protected]

United States of AmericaCarl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAPhone: +1 925 557 [email protected]

0297