smart building solution - chipkin automation systems · 2017. 2. 22. · smart buildings –...
TRANSCRIPT
SMART BUILDING SOLUTIONS
Controlled
InstantEnergy $avings
BAS
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
fromfromfromfrom
&
GatewayPeople Counter
Energy $avings
Our Value
Designing Solutionsthat deliver value Strong partnership
with industry leaders
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
Help controloperational costs
Team Work
Differentiation
Why Count in Buildings:
� Understand traffic flow - movement of people IN and OUT of the building – floor - room
� Understand occupancy levels in a room – floor - building
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
� Control Ventilation System based on actual occupancy
� React faster to changes in your IAQ (Internal Air Quality)
� Interface with any 'Building Automation System' (BAS)
Introducing the ‘Counter Network Gateway’
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
The CNG-1000/CAS Gateway is a Joint-Venture development between Chipkin
Automation Systems, Vancouver, a specialist engineering firm providing services
to 'Building Automation' users in North America, and Feedback Solutions,
Toronto, a People Counting company offering solutions built round 'people-counting'
technology to deliver value to customers.
With Energy Management being a concern for all property management companies,
Chipkin Automation & Feedback Solutions have jointly developed the 'Counter
Network Gateway' that enables communication between two diverse technology
platform and facilitates instant savings on energy consumption.
How the Gateway Works
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
Using accurate IP based 'People Counting Sensors', as the source for
capturing the flow of people into a building/floor/room the CNG-1000
Gateway converts 'Occupancy Data' and makes it available in real-time
on BACnet IP or Modbus TCP so that it can be discovered by any BAS
system. system.
BacNetGateway
IN – OUT
Data on
IP
OccupancyData on
BacNet
SensorBAS System
Data Available Every 5 minutes
Discover• Device Instance• Object• Properties
Adjusting your HVAC/ Lighting on any level you desire
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
Building
Floor 1
Floor 2
Entrance 1 (1 Sensor; 1 IP address)
Entrance 2 (1 Sensor; 1 IP address)
Entrance 1 (1 Sensor; 1 IP address)Floor 2
Floor 3
Entrance 1 (1 Sensor; 1 IP address)
Entrance 1 (1 Sensor; 1 IP address)Room 1
Floor 4Room 1
Room 2
Entrance 1 (1 Sensor; 1 IP address)
Entrance 1 (1 Sensor; 1 IP address)
Traditional Buildings
• Ventilation System running at full capacity irrespective of the number of people in each floor or building
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
• May or may not use a Building Automation System
• Waste of energy • Continuous use of ventilation
• Excessive heating or cooling of outside air• Huge energy bills
Smart Buildings - Controlling HVAC using a ‘CO2 Sensor’
• Ventilation Requirementadjusted based on CO2 levels Inside the building- when compared to CO2 levels Outside the building
CO2
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
• Based on assumed occupancy (number of people) on each floor / building
CO2Sensor
Cons –• Time lag to register change results in triggering
controls based on assumed occupancy and not actual occupancy
• Does not reflect occupancy in real-time hence not very accurate
Pros –• Save on Energy • Controlled use of ventilation • Lower energy bills• Lower cost of deployment
Smart Buildings – Controlling HVAC using a ‘People Counter’
• Ventilation adjusted based on actual occupancy (number of people) on each floor / building / room in real-time.
• Can calculate actual cfm based
PeopleCounter
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
• Can calculate actual cfm based on actual number of people inside
Cons –• Higher cost of deployment• Requires configuration of people counter on site
Pros –• Save instantly on Energy • Faster reaction to change in air• Better controlled use of ventilation • Lower energy bills• Short ROI• Extremely accurate
BACnetGateway
Where it can be used:
� Office buildings – floors – offices – meeting rooms
� University buildings – floors / classrooms/ lecture halls
� Libraries
Auditorium
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
� Auditorium
� Night club / Theatres
� Class rooms / Lecture halls
� Retail stores / Shopping malls
� Any building………..
What you get:
� Data in real-time
� Acceptable air quality
� Reduced energy consumption
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
� Reduced energy consumption
� Accurate occupancy values
� Lower energy bills - Instant savings
� Meet Ashrae standards
ROI:
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
Payback TimeSystem Cost
Monthly Energy Saving
Typical ROI is in few months.
About Us:
Feedback Feedback Feedback Feedback SolutionsSolutionsSolutionsSolutions
Chipkin Automation –
Chipkin Automation systems is a specialist engineering company excelling in areas of protocol conversion and system integration. Established in 2000, Chipkinautomation system has made a long journey providing niche solutions for building automation systems integration. Our primary purpose is to provide our customers with excellent solutions, and support them till the project is successfully done with. Chipkin automation system has been leaving an impression by providing excellent services worldwide.services worldwide.
Feedback Solutions -Feedback Solutions was launched in July 2012 with the objective of providing a platform where companies can utilize our expertise as a 'People Counting Technology' provider to design and develop solutions that utilize Count Data to address specific needs within the company. Solutions that will not only help them but one that can be applied by many more. Presently, we service the 'Library' and 'Smart Building' segment. Libraries for basic patron counting while smart buildings use our technology to save on energy consumption.