smart displacement type level transmitter 1 - 6th edition no. ss2-slx100-0100 smart displacement...

20
- 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters for the measurement. The model SLX is able to calculate boundary sur- face levels, specific gravity as well as liquid level. These microprocessor-based instruments have two-way communication capabilities that makes possible communication with the communicator with a SLX data base. Tasks such as self-diagno- sis or range or zero/span adjustment can, thus, be performed remotely. FEATURES Economical replacement • The model SLX can be fitted with a existing chamber and float making it an economic investment. Wide selection of element material • Select from various kinds of materials for wet- ted parts to best suit your individual application. • A wide range of allowable operating pressures and specific gravities is available to choose from. High performance and highly reliable • Specific gravity for the process fluid can be set from the communicator. • The effect of transient temperature is minimal. Easy to adjust and maintain • Remote setting of range, self-diagnosis, zero/ span adjustment can be made from the commu- nicator. • Exact, dumping and zero/span adjustments can be made by just using a screwdriver without having to open the meter cover. • An LCD display indicator makes it easier to monitor liquid level and output. Compatible housing and parts • Field proven chamber and float • The transmitter housing is common use with our differential pressure transmitter. • Highly resistant to vibration APPLICATIONS Reactor, distillation, drum, recovery level measurement Boundary surface, specific gravity measurement Cryogenic (-196 °C liquefied gas etc.) and high-temper- ature (+ 400 °C) applications High-vacuum (-101.3 kPa) and high-pressure (15 MPa) applications

Upload: trantu

Post on 18-Mar-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

- 1 - 6th edition

No. SS2-SLX100-0100

Smart Displacement type Level Transmitter

Model SLX

OVERVIEW

The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters for the measurement. The model SLX is able to calculate boundary sur-face levels, specific gravity as well as liquid level. These microprocessor-based instruments have two-way communication capabilities that makes possible communication with the communicator with a SLX data base. Tasks such as self-diagno-sis or range or zero/span adjustment can, thus, be performed remotely.

FEATURES

Economical replacement• The model SLX can be fitted with a existing

chamber and float making it an economic investment.

Wide selection of element material• Select from various kinds of materials for wet-

ted parts to best suit your individual application.• A wide range of allowable operating pressures

and specific gravities is available to choose from.

High performance and highly reliable• Specific gravity for the process fluid can be set

from the communicator.• The effect of transient temperature is minimal.

Easy to adjust and maintain• Remote setting of range, self-diagnosis, zero/

span adjustment can be made from the commu-nicator.

• Exact, dumping and zero/span adjustments can be made by just using a screwdriver without having to open the meter cover.

• An LCD display indicator makes it easier to monitor liquid level and output.

Compatible housing and parts• Field proven chamber and float• The transmitter housing is common use with

our differential pressure transmitter.• Highly resistant to vibration

APPLICATIONS• Reactor, distillation, drum, recovery level measurement• Boundary surface, specific gravity measurement• Cryogenic (-196 °C liquefied gas etc.) and high-temper-

ature (+ 400 °C) applications• High-vacuum (-101.3 kPa) and high-pressure (15 MPa)

applications

Page 2: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 2 -

OPERATION PRINCIPLEOne side of the torque tube is fixed onto the torque tube housing with screw. And the other side of the torque tube is assembled with torque arm, which is supported at the knife-edge supporting point. When installing or using the level mea-surement, suspend the float on the edge of the torque arm, and then the torque tube will be twisted by the float's weight. Use the level measurement in this condition.

When process liquid level changes, buoyancy will generate on the float according to the “Principle of Archimedes”. (Dis-placement type float is heavy. Therefore, float displacement may not change the level despite of the liquid level change. In general, it is designed as to be “generated buoyancy of liquid level at 100 % < float mass”). The proportionally generated buoyancy to the level, converts into torque by torque arm/knife-edge which suspends the float, and to the torque tube. Torque tube functions as to enclose the process liquid and as torsion spring function, and converts torque into angle dis-placement. This angle displacement transfers through torque rod and coupling, and detected by the angle displacement sensor. Then, it will be converted into liquid level signal by A/D converter, and sent it to CPU.

In case the process liquid contacts with torque tube, the shearing module of the torque tube material will be changed by liquid temperature, and then changes the torsional spring constant, and generates the output shift. To compensate the out-put shift, which generates by liquid temperature, temperature around the torque tube is detected by the temperature sensor, converted into temperature signal by A/D converter and then sent to CPU.

These liquid level signal and temperature signal are computed by CPU, and become digital signal based on each config-ured range by the communicator. This computed value will be converted into 4 to 20 mA DC analog signal with D/A con-verter and will be output.

Moreover, model SLX is provided parameters to compensate the output shift which generates by liquid temperature. (Default parameters are set at shipment, can be set using the communicator later.)

Figure 1 Model SLX - Structure of signal route and signal block diagram

Torque arm

FloatKnife-edge

Case

Coupling Shaftbearing

Torque rod

Temp. sensor

Torque tube

Angle sensorExtension

Torque tube housing

Extension assembly

Measurement assembly

Torque tube housing assembly

Float assembly

Liquid levelMeasurementliquid

(electriccircuit)

4 to 20 mA0 to 100 %

Liquid level(specific gravity)0 to 100 %

anglesensorA/DCPUD/A coupling Torque

rodTorquetube

Torque arm/ Knife-edge Float

Output Input

Temperaturesensor

TemperatureVoltage

Voltage (Angle) (Angle) Angle Torque Buoyancy

Page 3: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 3 -

FUNCTIONAL SPECIFICATIONS

Measuring range.

Range of specific gravity1) For level measurement: 0.1 to 1.62) For boundary surface measurement, see the following.

When the specific gravity of upper layer liquid is γ2, and

lower layer liquid is γ3,

γ2 < γ3, 0.4 < γ2, γ3 < 1.6, 0.1 < γ3 - γ2 < 1.2

See Figure 2

Figure 2 Range of Specific gravityMedium: Up to JIS63K, ANSI/JPI600 are available as

standardLow: Up to JIS30K, ANSI/JPI300 are available as

standardIf a range beyond those listed here is required, please consult an Azbil Corp. sales representative.For details, see Table 4 and Table 5.

Output / CommunicationAnalog output (4 to 20 mA DC, min. 3.8 mA, max. 20.8 mA)

Burn-out on failure(Three optional directions can be selected)No output burnoutOutput burnout to upscale (over 20.8 mA)Output burnout to down-scale (under 3.8 mA)

Supply voltage and load resistance18.5 to 45 V DC. A load resistance of 250 Ω or more is necessary in a loop. See Figure 3.

Figure 3 Power supply voltage / load resistanceNote) For communication with the communica-

tor, a load resistance of 250 Ω or more is required.

Stability against supply voltage change± 0.005 % F.S./V

Damping timeSelectable from 0 to 100 sec. in increments of ten

Lightening protection characteristicsVoltage surge wave, maximum: 12 kVCurrent surge wave, maximum: 1000 A

Operating pressure-101.3 kPa to each flange ratingPressure (Up to JIS63K, ANSI/JP600#, can be extended to ANSI/JIS1900# with certain conditions) See Table 4 and Table 5.

Operating humidity5 to 100 %RH

Table 1 Model SLX measuring ranges

Range (mm) Measuring and setting range (mm)

0 to 300 Set applicable within the range shown left

0 to 350

0 to 400

0 to 450

0 to 500

0 to 600

0 to 700

0 to 800

0 to 1000

0 to 1200

0 to 1500

0 to 2000

1.6

0.6

0.4

0.20.15

0.1

300 500 700 2000

Spec

ific

gra

vity Medium

(Specific gravity)

Medium(Specific

gravity)

Medium(Specific

gravity)

LowLow

Low

Maximum Range (mm)

1467

500

250

0 13.0 18.5 24 45

OperatingRange

R= E-130.0218

Load

Res

ista

nce

Supply Voltage (V DC)

Page 4: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 4 -

Operating temperatures

For explosion-proof type or with these having the digital meter option, the temperature ranges are as follows:

With digital indicator (option):Normal operating range: -20 to +70 °COperative limits: -30 to +80 °C

JIS flameproof type: Ambient temperature: -20 to +55 °C

Figure 4 For liquid level of boiler application and boundary surface measurement

Figure 5 For liquid level measurement other than boiler application

PHYSICAL SPECIFICATIONS

MaterialSee “Table 6 Material” on page 5.

Case finish

CaseLight beige (Munsell 4Y7.2/1.3)

CoverDark beige (Munsell 10YR4.7/0.5)

WeightApprox. 28 kg (For model SLX110-10551E131-11X-X)

Enclosure ratingEquivalent IEC IP66 / NEMA 4X / JIS C 0920 Watertight

Explosion proofJIS flameproof (Exd IIC T3, Exd IIC T4, Exd IIC T5, Exd IIC T6)NEPSI flameproof (Exds IIC T3, Exds IIC T4, Exds IIC T5, Exds IIC T6)

Note) 1. When selecting explosion-proof specifica-tions, please carefully read the following:Industrial Safety Laboratory's Technical Guideline/Factory Explosion-proof Elec-tric Facility Guide (Gas Explosion Proof-ing 1994), published by Industrial Safety Engineering Institute

Note) 2. When making changes to an existing facil-ity, abide by the explosion proofing con-struction of the existing devices.Example: d2G4 model SLX: ExdIICT4

Figure 6 Allowable external temperature

Table 2 Operating temperatures (°C)

Ambient temperature

Fluid temperature

Standard operation 23±2 23±2

Normal operation -30 to +80 -196 to +400

Operative limits -40 to +85 -196 to +400

Transportation/storage -40 to +85 -40 to +85

600

500

400

300

200

100

-100

-200

0

(0, -196)

(50, 400)

(50, 200)

(80, 80)

Long Extension(Other material: U, M)

Standard Extension(Other material: A, E, D, W)

(-30, -30) -30 -20 -10 0 10 20 30 40 50 60 70 80

Flu

id T

emp

erat

ure

( C

)

Ambient Temperature ( C)

600

500

400

300

200

100

-100

-200

0

(0, -196)

Long Extension(Other material: U, M)

Standard Extension(Other material: A, E, D, W)

(-30, -30) -30 -20 -10 0 10 20 30 40 50 60 70 80

Flu

id T

emp

erat

ure

( C

)

Ambient Temperature ( C)

Table 3 Temperature classifications for explosion-proof

Temperature level

Maximum allowable external

temperature*

Atmospheric ignition temperature

T3 135 °C to 200 °C Over 200 °C

T4 100 °C to 135 °C Over 135 °C

T5 85 °C to 100 °C Over 100 °C

T6 85 °C or less Over 85 °C

* "Maximum allowable externaltemperature" is the temperatureof this part

Page 5: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 5 -

Note) The float weight in the above table is for liquid level application.For interface or hyarometer applications, below conditions will apply:1. Medium specific gravity (model SLX110): Identical to the figures above,2. Low specific gravity application (model SLX120): Depends on customer's specifications. (Weight for liq-

uid level specifications will be the minimum and it will increase depending on customer's specifications)

Table 4 Float test pressure - Material: SUS316L

Model No.Measuring

range (mm)

Medium specific gravity (model SLX110) Low specific gravity (model SLX120)

Float dia. (mm)

Weight (Kg)

With standing pressure (MPa)

Flange rating

Float dia. (mm)

Weight (kg)

With standing pressure (MPa)

Flange pressure

rating (MPa)

03 0 to 300

55

1.8

15.0

Up toJIS 63K,

ANSI /JPI 600

95 3.4

7.8

Up toJIS 30K,

ANSI /JPI 300

A3 0 to 350 2.2 3.804 0 to 400 2.2 4.2A4 0 to 450 2.2 4.205 0 to 500 2.6 4.606 0 to 600

45

2.2 85 3.4

3.2

Up to JIS10K,

ANSI / JPI 150

07 0 to 700 2.2 3.808 0 to 800 2.6 4.210 0 to 1000 3.0 5.012 0 to 1200

301.8 65 3.8

15 0 to 1500 2.2 4.220 0 to 2000 3.0 55 4.2

Table 5 Float test pressure - Material: Hastelloy C

Model No. Measuring

range (mm)

Medium specific gravity (model SLX110) Low specific gravity (model SLX120)

Float dia. (mm)

Weight (Kg)

With standing pressure (MPa)

Flange rating

Float dia. (mm)

Weight (kg)

With standing pressure (MPa)

Flange pressure

rating (MPa)

03 0 to 300

55

1.8

7.8

Up toJIS 30K,

ANSI / JPI 300

95

3.8

7.8

Up to JIS30K,

ANSI /JPI 300

A3 0 to 350 2.2 3.404 0 to 400 2.2 3.8A4 0 to 450 2.2 4.205 0 to 500 2.6 4.206 0 to 600

45

2.2

85

4.2

3.2

Up to JIS10K,

ANSI / JPI 150

07 0 to 700 2.2 4.608 0 to 800 2.6 5.010 0 to 1000 3.0 5.012 0 to 1200

301.8

653.4

15 0 to 1500 2.2 4.220 0 to 2000 3.0 55 4.2

Table 6 Material

Model (temp. range)

Part

U M A E D W

(350 to 400 °C) (200 to 350 °C) (0 to 200 °C) (0 to 200 °C) (-196 to 0 °C)*i

Note) *i. Available at the range of 0 to 200 °C.

(-40 to +200 °C)

Housing Aluminum alloyTorque tube inconel SUS316L Hastelloy C

Bonnet / chamber Carbon steel (SFVC2A), SUS304, SUS316, SUS316L*ii

Note) *ii. If the optional code is “D”, carbon steel cannot be selected.

SUS316L

Float SUS316L Hastelloy CBolt Chromium-Molydbenum steel (SNB7) SUS304

Gasket Spring type (Semi-metallic, Filler material: Graphite)Extension SUS304 (Long) SUS304 (Standard)

Sensor housing Aluminum alloy casting

Page 6: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 6 -

INSTALLATION

Electrical conduitG½ internal thread, ½NPT internal thread (JIS flameproof is not applicable)

GroundingResistance 100 Ω max.

Wiring connectionWiring terminals screw (M4, SUS304)

Process connectionFlange

External chamber type

ConnectionSide - SideSide - BottomTop - SideTop - Bottom

Flange size2 in. or 1½ in. RF (ANSI / JPI 600)2 in. or 1½ in. RTJ (ANSI/JPI 600)

Internal float type

ConnectionTop

Flange size3, 4, or 5 in. RF (ANSI/JPI 600)3 or 4 in. RTJ (ANSI/JPI 600)

PERFORMANCE

Accuracy rating(at load correction under standard operating condition)+/-0.5 % F.S. (for specific gravity, see Figure 2)

Ambient temperature characteristics(Ambient temperature range: -30 to +80 °C, note1) Zero shift: ± (1.5 × α) % F.S. / 55 °C

Span shift: ± (1.5 × α) % F.S. / 55 °C

Fluid temperature characteristics(Fluid temperature range: -196 to +400 °C, note 1 and 2)Zero shift: ± (1.5 × α) % F.S. / 55 °C

Span shift: ± (1.0 × α) % F.S. / 55 °CNote) 1) Correction factor “α” changes depending

on the mass of measured fluid displaced by float “Mf” when liquid level changes from 0 to 100%. (In case model number is model SLX110, and its measurement range is 300 mm, and specific gravity is 1, “α” will be 1.)

Wherein:D: Float diameter (mm)H: measuring range (Float length is standard,

mm)γ: Specific gravity of measuring liquid

ρstd:Standard density, ρstd = 1 (g/cm3)

π: Circle ratio

Note) 2) Only for liquid surface measurement, when temperature correction coefficient: a variable parameter to reduce the operating influence from the process temperature, is 1.0 (default value at shipment) (Not applicable for bound-ary surface level measurement)

α 709Mf---------=

Mfπ 4⁄( ) D

2H γ ρstd 10

3–×××××

1 5.76 107– π D

2 γ ρstd×××××+--------------------------------------------------------------------------------------=

Page 7: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 7 -

OPTIONAL SPECIFICATIONS

Corrosion-resistant finish

StandardBaked acrylic finish

Corrosion-resistant finishBaked acrylic finish, fungus-proof finish

Corrosion-proof finishBaked epoxy finish, fungus-proof finish

Built-in indicator• Digital LCD indicator (optional)• Digital actual scale (SI unit) available• Liquid level display (%, mm)• Specific gravity display• Available to set from -3000 to +3100 (limit of resolution

is 0.1) (4.5 digits) arbitrary. For actual scale, specify the following items when ordering.

• Actual scale range• Actual scale unit (mm)Each setting are executed using the communicator.

ElbowThis is an adaptor to match the electric conduit connection to field wiring conditions, from horizontal to vertical visa versa. One or two can be selected depending on the field installation requirements.

Oil-free / Water-free treatment (only for SUS material)Measuring range of 1000 mm or less:Delivered after eliminating oil and water from wetted sur-face.

Oil-free treatment (only for SUS material)Measuring range of 1000 mm or less:Delivered after eliminating oil from wetted surface.

Test reportThis report gives the results of testing, including the exter-nal appearance of the liquid level meter, input / output characteristics (3 points), insulation resistance and with-standing voltage tests.

Five points checkThe measuring point of input / output characteristics described on the test report is changed from 3 points (0, 50, 100 %) to 5 points (0, 25, 50, 75, 100 %)

Traceability certificateThis report consists of three parts; a measurement manage-ment system chart, a calibration certificate and a test report.

Mil sheetTest results of chemical composition, heat treating condi-tions and mechanical properties of main materials (torque tube housing, bonnet, chamber) will be submitted as certif-icate.

Color checkResult of color check penetration test for welding faults on main materials (bonnet, chamber) will be submitted as cer-tificate.

Without float(Please contact to sales representative)Float will not be provided.Please specify if reusing an existing Azbil Corporation's float having the model number NQ31, NQI21, KQP1, KFL00-1, NQP31 or NQP21.

Without chamber(Please contact to sales representative)Chamber will not be provided.Please specify if reusing an existing chamber having the model number NQI31, NQI21, KQP1, KFL00-1, NQP31 or NQP21.

Page 8: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 8 -

SEMI-STANDARD SPECIFICATIONS

1. Stainless steel bolt (Y131):For this feature, SUS304 bolts are used for main body assembly. This will be a certified product under High Pressure Gas Law. If the connecting size is JIS10K, NASI150 or JPI150, please consult an Azbil Corp. repre-sentative.

2. Silver corrosion proof (acrylic) paint (Y138D)

For the prevention of temperature rise by sunlight or radiation heat, as well as protection against corrosive atmosphere. (Note: This does not apply to alkali atmo-sphere)

3. High pressure gas certification (Y2054)Please refer to the following for scope of manufacture:Scope of liquid level instrument manufacture as certified by Minister for high pressure gas types:1)-1 Title of certification: Liquid level measurement,

float type (including welding construction)1)-2 Scope of certified specifications:

Refer to Table 7 "Scope of certified specifications" for design temperatures, pressures and connecting sizes.1)-3 The listing in Table 7 shows scope of certified spec-

ifications, not a scope of certified liquid level meter manufacturing. The scope of manufacture of the certified liquid level meter is within the tempera-tures and pressures listed in the Spec. Sheet.

Note) * When using SF440A. However, the standard material is SFVC2A, temperature will be “0 °C or higher”.

Attention in usage• Azbil Corporation's standard Displacement type level

transmitter measurement range is set equivalent to float length H. Therefore, it will be unsuitable when detecting the levels around 0 % or 100 % (at normal operation), or when continuous output of 4mA or less or 20 mA or more is needed.

• When conducting the actual liquid adjustment (filling adjustment) after installing the displacement type level transmitter at the job site, be sure to set the float bottom to zero point (reference point at 0 % liquid level). (Struc-turally, if the measurement fluid is not in contact with float, output will not change.)If other than the float bottom is set to zero point (refer-ence point at 0 % liquid level), it may cause the measure-ment dead-band at the measurement range of lower limit (or upper limit), or may cause output linearity error.

Figure 7 Appropriate way of adjustment: Set float bottom at zero point

Figure 8 Inappropriate way of adjustment: set other than the float bottom at zero point

Communicator OperationParameter setting(1) Damping: 0~100 sec.

(2) Specific gravity: 0.1~1.6 *Note

(3) Burnout: NON, UP, DOWN(4) Span: Set freely within specified range

Calibration

1. Zero adjustment *1

2. Span adjustment

3. Exact adjustment *2

Table 7 Scope of certified specifications

Certificate No.

MAB-342-0-2Type of equipm

ent

Other accessories

Des

crip

tion

(Typ

e)

MaterialDesign

temperature

Des

ign

pre

ssu

re(M

pa)

Con

nec

tin

gd

ia.(

A)

Oth

ers

Class Group Max. °CMin.°C

Liq

uid

leve

l met

er

(Buo

yanc

y ty

pe)

Carbon steel

G4 450 -10 *Under

6.4Under 125

Stain-less steel

G1 400 -196Under

6.4Under 125

G4 800 -269Under

6.4Under 125

G6 800 -196Under

6.4Under 125

Zero point

Measuringrange Float length H

Measuringrange

Zero point

Zero point

Measurementdead-band

Measurementdead-bandMeasuring

range

Page 9: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 9 -

Note *1) Make sure that this is done after completing instal-lation at the site.

*2) Match the liquid level measurement output with what is being indicated in the glass gauge. Zero can be adjusted to be set to a point anywhere between 0-100% of the range to match.

Display on communicator screen1. Input liquid level2. PV value3. Torque tube temperature4. Instrument temperature

CalibrationProofing by the communicator using a weight is possible.

OthersSelf-diagnostic functions

External adjustmentUse screwdriver (flat screwdriver) from external side of instrument. Zero, span and damping adjustments are possible. Built-in indicator must be selected to use this adjustment.

Note) Change of specific gravity range• It is necessary to define the specific gravity of the liquid to be

measured in order to manufacture the model SLX correctly. However, range change with the communicator will suffice for range setting change for the ranges listed below.

• The scope of range change by the communicator depends on the float size for medium specific gravity range (model SLX110) / or low specific gravity range (model SLX120).Also, note that there is a limitation on boundary surface mea-surement (hydrometer) specifications for the low specific grav-ity meter (model SLX120).

1. Medium specific gravity (model SLX110):1-1. For liquid level measurement specifications, range

change is possible within the ‘Specific Gravity Range’ as given in Table 8 below.

1-2. For an boundary surface measurement (hydrometer), range change is possible within the scope given in Figure 2 "Range of Specific gravity".

The parameters are as follows:• Boundary surface measurement: Δγ = γ3 - γ2, γ3 > γ2

Whereas: γ2: Specific gravity of upper layer liquidγ3: Specific gravity of lower layer liquid

• Hydrometer: Δγ = γ5 -γ4, γ5 >γ4Whereas: γ4: Upper limit of specific gravity measurement

γ5: Lower limit of specific gravity measurement2. Low specific gravity meter (model SLX120)

2-1. Range change of liquid level meter specification is allow-able within the “Range of Specific gravity”, as given in Figure 2.

2-2. Boundary surface measurement (hydrometer) specifica-tions have following limitations on range change:

• Input Δγ from the the communicator.• The result of specific gravity range change may fall outside

of SS specifications, thereby accuracy cannot be achieved. The accuracy of the meter after range change can be veri-fied by substituting specific gravity γ, with the differential specific gravity Δγ in the verification equation on page 12.

Table 8 Specific gravity range 1

Measuring range (mm)

Allowable specific gravity range γ change by

communicator

300 to 499 0.6 < γ <1.6500 to 2000 0.4 < γ < 1.6

Table 9 Specific gravity range 2

Measuring range (mm)

Allowable differential specific gravity range

Δγ change by communicator

Range of γ3 (or γ5)

300 to 499 0.6 < Δγ < 1.6 γ3(or γ5) < 1.6500 to 2000 0.4 < Δγ < 1.6 γ3(or γ5) < 1.6

Table 10

Measuring range (mm)

Allowable specific gravity range γ change by

communicator

300 to 499 0.2 < γ < 0.6500 to 699 0.15 < γ <0.4700 to 2000 0.1 < γ <0.4

Table 11

Measuring range (mm)

Range change parameter γ2, (γ4)

Range change parameter γ3,

(γ5)

300 to 2000Up to +10 % of spec-

ified initial setting value

Up to +5 % of initial setting

value

Page 10: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 10 -

MODEL SELECTIONBasic model number Selections Options

(Continued)(Continued from previous page)

Medium type for specific gravity (0.4 to 1.6): SLX110- I II III IV V VI VII VIII - IX X XI - XII

Low type for specific gravity (0.1 to 0.4): SLX120 *1

Selections I II III IV V VI VII VIII

I Output/ Communication Analog 4 to 20 mA output (Standard) 1II Measuring range

(mm)0 to 300 0 30 to 350 A 30 to 400 0 40 to 450 A 40 to 500 0 50 to 600 0 60 to 700 0 70 to 800 0 80 to 1000 1 00 to 1200 1 20 to 1500 1 50 to 2000 2 0Others X X

III Connection External type Side – Side 1External type Side – Bottom 2External type Top – Bottom 3External type Top – Side 4Internal Top L1 length is required when ordering 5Others X

IV Main Materials Bonnet/ Chamber Torque tube Housing (TH)Carbon steel Carbon steel (unavailable when temperature 0 °C or lower) 1SUS304 SCS13A 2SUS316 SCS14A 3SUS316L SCS16A 4Others X

V Other materials *3(Temperature range *2)

Torque tube: Inconel (350 to 400 °C) UTorque tube: Inconel (200 to 350 °C) MTorque tube:Inconel(0 to 200 °C) ATorque tube:SUS316L(0 to 200 °C) E

Torque tube:SUS316L (-196 to 0 °C) *2 D

Torque tube: Hastelloy C (-40 to +200 °C) Selection of “4” must be given for “IV material” WOthers X

VI Pressure rating (Type of Joint)

JIS10K (RF) 1JIS20K (RF) 2JIS30K (RF) 3JIS63K (RF) 4ANSI150 (RF smoothing) AANSI150 (RF serration) BANSI300 (RF smoothing) CANSI300 (RF serration) DANSI600 (RF smoothing) EANSI600 (RTJ) FJPI150 (RF) GJPI300 (RF) HJPI600 (RF) JJPI600 (RTJ) K

Others *4 X

VII Flange size 1½ in. (40 mm) For external type 12 in. (50 mm) For external type 23 in. (80 mm) For internal type (medium type only) 34 in. (100 mm) For internal type 4

5 in. (125 mm) *1 For internal type (low type only) 5

Others XVIII Meter body Left side 1

Right side 2

Page 11: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 11 -

Options

*1 to 8: Refer to page 12.

IX Electrical conduit / Explo-sion-proof approvals

G½ / Watertight X

G½ / JIS Flameproof (Ex dsI IC T3) with 1 pc. of cable gland 1

G½ / JIS Flameproof (Ex ds IIC T4) with 1 pc. of cable gland 2

G½ / JIS Flameproof (Ex ds IIC T5) with 1 pc. of cable gland 3

G½ / JIS Flameproof (Ex ds IIC T6) with 1 pc. of cable gland 4

G½ / JIS Flameproof (Ex ds IIC T3) with 2 pcs. of cable gland A

G½ / JIS Flameproof (Ex ds IIC T4) with 2 pcs. of cable gland B

G½ / JIS Flameproof (Ex ds IIC T5) with 2 pcs. of cable gland C

G½ / JIS Flameproof (Ex ds IIC T6) with 2 pcs. of cable gland D

½NPT / NEPSI Flameproof (Ex ds IIC T3) without cable gland *5 E

½NPT / NEPSI Flameproof (Ex ds IIC T4) without cable gland *5 F

½NPT / NEPSI Flameproof (Ex ds IIC T5) without cable gland *5 G

½NPT / NEPSI Flameproof (Ex ds IIC T6) without cable gland *5 H

½NPT/ Watertight 5

X Built-in Indicator None (without external adjustment switch / without explosion-proof) X

Scale in % (0 to 100 % liner scale) *5 1

Engineering unit scale (only “mm” unit) *5 2

XI Finish Standard XCorrosion-resistant finish ACorrosion-proof finish B

XII No option X

One elbow (left) *5 1

One elbow (right) *5 2

Two elbows *5 3

Oil-free treatment / water-free treatment (only for SUS material) range = 1000 mm or less 4Oil-free treatment (only for SUS material) range = 1000 mm or less 5

Test report *6 6

Five points check *6 7

Material certificate 8

Traceability certificate *6 A

Color check B

Without Float *7 C

Without Chamber *8 D

Page 12: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 12 -

Note)*1) For low specific gravity applications or 5B/125A,

pressure ratings 4, E, F, J and K cannot be selected.

*2) When other material is “D”,1. Temperature 0 to 200 °C is available2. Element material “1” cannot be selected.

*3) Float materials are as follows:

Bolt and nut materials are as follows:

* If Y131 is specified bolt / nut material with * mark can be changed to SUS304 / SUS304

*4) For class 900, contact the Azbil Group representa-tive. Also, class 1500 or higher cannot be manufac-tured.

*5) For the NEPSI flameproof model, only the model codes with the Built-in Indicator are available. However, the codes with the elbow are not avail-able.

*6) When changing measurement point of input / output characteristic written on test report from 3 points (0, 50, 100 %) to 5 point (0, 25, 50, 75, 100 %), select “7” for option together. Option “7” cannot be selected by itself.

*7) Specify when reusing Azbil Corporation's existing float. Pay attention to the following matters:

1. The prerequisites for selecting Additional Specifications C are: “Liquid level specifica-tions - medium specific gravity - Azbil Corpo-ration's models NQI31, NQI21, KQP1, KFL00-1, NQP31 or NQP21 without suffix Z

2. Small diameter float may be delivered due to special design outside of SS specification selec-tion.

3. Please make sure that you confirm the diameter of the existing float to ensure accuracy.• Standard characteristics of model SLX

* The model SLX offers consistent accuracy regardless of liquid level measurement, boundary surface mea-surement or hydrometer applications• Equation to calculate meter accuracy:

Wherein:D: Float diameter (mm)H: Measuring range (float length, mm)

: Specific gravity

std: Standard density, std. = 1 (g/cm3)

: Circle ratioReference: Equation to calculate buoyancy by float

Whereas:: Density of surrounding (measured) fluid,

V: Volume of surrounding (measured) fluid dis-placed by float,

G: Gravity acceleration,Mf: Mass weight of fluid displaced by float

*8) Specify when reusing a chamber. Pay particular attention to the following matters:Please ensure that the model number is one of the following Azbil Corporation's models: NQI31, NQI21, KQP1, KFL00-1, NQP31 or NQP21 without suffix “Z”. If suffix “Z” is speci-fied, the chamber and bonnet connecting size should be 3 in. (nominal) ANSI/JPI50, 300, 600 RF.

* When ordering, specify the following:

Name of fluid =

Type of gas =

Temperature: Normal = °CMin. = °CDesign temperature = °C

Pressure: Normal = MPaMax = MPaDesign pressure = MPa

Other material Float material

U, M, A, E, D SUS316LW Hastelloy C

Other material Bolt / nut material

U, M, A, E SNB7 / S45C *D, W SUS304 / SUS304

Mass of measured fluid displaced by float Mf

Mf > 400 400 > Mf > 200 200 > Mf

Accuracy +/- 0.5 +/- 1.0Outside of guar-anteed accuracy

Mf π 4⁄ D2

H γ ρstd 103–×××××

1 5.76 107– π D

2 γ ρstd×××××+---------------------------------------------------------------------------------------- g( )=

ModelSLX10---

Specific gravity (enter to third decimal point) For liquid level meter =For boundary surface measurement:

Upper level liquid =Lower level liquid =

For hydrometer:Range of specific gravity measurement =

Dimension from the bottom of flange to top of float (L1) =Round off after the decimal point and specify using “mm” unit.If L1 > 1500 mm, consult with sales representative.

: Make sure to specify the necessary information in the box.

γ

ρ ρπ

F ρ V G×× Mf G×= =

ρ

Page 13: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 13 -

DIMENSIONS

External Float typeS-S: Side - Side [Unit: mm]

Note) 1: Dimensions shown inside the bracket is for pressure rating of JIS 20K, JIS 30K, JPI 300 and ANSI 300.2: When pressure rating is JIS 10K, hub shown in the figure above will not be provided.

(Standard, with indicator)(Standard, without indicator)(for high temperature, with indicator)(for high temperature, without indicator)

(Standard)(for high temperature)

(with indicator)(without indicator)

Housing Sensor housingTorque tubehousing

Extension

Bonnet

Bolt / nut (refer to table 2)Gasket

Bolt / nut(refer to table 2)Gasket

Chambersize: 3 in.

Float

Note2

R3/4 drain plug

Terminal connection(Terminal screw size: M4)

refer to table 1

M4, Terminal screwfor grounding

Electric conduitconnection port

Mounting position: right side (Optional)

Note 1

Table 1. Terminal Table 2. Bolt / nut material Table 4. Size H

Symbol DescriptionS+, S- Power supply and output signal terminalCHK+, CHK- Terminal for check meterM+, M- Terminal for ammeter installed outsideE Ground terminal

Bolt / nut materialU, M, A, E SNB7 / S45C *D, W SUS304/SUS304

Measuring range (mm) H 0 to 300 300 0 to 350 350 0 to 400 400 0 to 500 500 0 to 600 600 0 to 700 700 0 to 800 800 0 to 1000 1000 0 to 1200 1200 0 to 1500 1500 0 to 2000 2000

Table 3. Connecting flange size

40 mm50 mm1 1/2 in.

2 in.40 mm50 mm40 mm50 mm1 1/2 in.

2 in.

D140155127152140155160165155165

G8196

73.291.9819690

10573.291.9

T161618

19.51818222221

22.5

f22

1.61.62222

1.61.6

C10512098.6

120.6105120120130

114.3127

H-N19-419-416-419-419-419-823-419-822-419-8

Flange rating

JIS 10 K RF

JIS 20 K RF

JIS 30 K RF

JPIANSI

150 RF

JPIANSI

300 RF

* When Y131 is specified, bolt/nut material shall be SUS304/SUS304.

Case

pc.

External adjustment switch (without indicator)

Page 14: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 14 -

S-B: Side - Bottom [Unit: mm]

Note) 1: Dimensions shown inside the bracket is for pressure rating of JIS 20K, JIS 30K, JPI 300 and ANSI 300.2: When pressure rating is JIS 10K, hub shown in the figure above will not be provided.

Note 1

(Standard, with indicator)(Standard, without indicator)(for high temperature, with indicator)(for high temperature, without indicator)

(Standard)(for high temperature)

Housing Sensor housingTorque tubehousing

Extension

Bonnet

Bolt / nut (refer to table 2)Gasket

Bolt / nut(refer to table 2)

pc.

Gasket

Chambersize: 3 in.

Float

Note2

Terminal connection(Terminal screw size: M4)

refer to table 1

M4, Terminal screwfor grounding

Electric conduitconnection port

Mounting position: right side

Table 1. Terminal Table 2. Bolt / nut material Table 4. Size H

Symbol DescriptionS+, S- Power supply and output signal terminalCHK+, CHK- Terminal for check meterM+, M- Terminal for ammeter installed outsideE Ground terminal

Bolt / nut materialU, M, A, E SNB7 / S45C *D, W SUS304/SUS304

Measuring range (mm) H 0 to 300 300 0 to 350 350 0 to 400 400 0 to 500 500 0 to 600 600 0 to 700 700 0 to 800 800 0 to 1000 1000 0 to 1200 1200 0 to 1500 1500 0 to 2000 2000

Table 3. Connecting flange size

* When Y131 is specified, bolt/nut material shall be SUS304/SUS304.

40 mm50 mm1 1/2 in.

2 in.40 mm50 mm40 mm50 mm1 1/2 in.

2 in.

D140155127152140155160165155165

G8196

73.291.9819690

10573.291.9

T161618

19.51818222221

22.5

f22

1.61.62222

1.61.6

C10512098.6

120.6105120120130

114.3127

H-N19-419-416-419-419-419-823-419-822-419-8

Flange rating

JIS 10 K RF

JIS 20 K RF

JIS 30 K RF

JPIANSI

150 RF

JPIANSI

300 RF

Case

(Optional)

(with indicator)(without indicator)

External adjustment switch(with indicator)

Page 15: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 15 -

T-B: Top - Bottom [Unit: mm]

Note) 1: Dimensions shown inside the bracket is for pressure rating of JIS 20K, JIS 30K, JPI 300 and ANSI 300.2: When pressure rating is JIS 10K, hub shown in the figure above will not be provided.

(Standard, with indicator)(Standard, without indicator)(for high temperature, with indicator)(for high temperature, without indicator)

(Standard)(for high temperature)

Housing Sensor housingTorque tubehousing

Extension

Bonnet

Bolt / nut(refer to table 2)Gasket

Bolt / nut(refer to table 2)

pc.

Gasket

Chambersize: 3 in.

Float

Terminal connection(Terminal screw size: M4)

refer to table 1

M4, Terminal screwfor grounding

Electric conduitconnection port

Mounting position: right sideNote 1

Table 1. Terminal Table 2. Bolt / nut material Table 4. Size H

Symbol DescriptionS+, S- Power suuply and output signal terminalCHK+, CHK- Terminal for check meterM+, M- Terminal for ammeter installed outsideE Ground terminal

Bolt / nut materialU, M, A, E SNB7 / S45C *D, W SUS304/SUS304

Measuring range (mm) H 0 to 300 300 0 to 350 350 0 to 400 400 0 to 500 500 0 to 600 600 0 to 700 700 0 to 800 800 0 to 1000 1000 0 to 1200 1200 0 to 1500 1500 0 to 2000 2000

Table 3. Connecting flange size

* When Y131 is specified, bolt/nut material shall be SUS304/SUS304.

40 mm50 mm1 1/2 in.

2 in.40 mm50 mm40 mm50 mm1 1/2 in.

2 in.

D140155127152140155160165155165

G8196

73.291.9819690

10573.291.9

T161618

19.51818222221

22.5

f22

1.61.62222

1.61.6

C10512098.6

120.6105120120130

114.3127

H-N19-419-416-419-419-419-823-419-822-419-8

Flange rating

JIS 10 K RF

JIS 20 K RF

JIS 30 K RF

JPIANSI

150 RF

JPIANSI

300 RF

Case

(Optional)

Note 2

(with indicator)(without indicator)

External adjustment switch(with indicator)

Page 16: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 16 -

T-S: Top - Side [Unit: mm]

Note) 1: Dimensions shown inside the bracket is for pressure rating of JIS 20K, JIS 30K, JPI 300 and ANSI 300.2: When pressure rating is JIS 10K, hub shown in the figure above will not be provided.

(Standard, with indicator)(Standard, without indicator)(for high temperature, with indicator)(for high temperature, without indicator)

(Standard)(for high temperature)

Housing Sensor housing Torque tube

Extension

Bonnet

Bolt / nut(refer to table 2)Gasket

Bolt / nut(refer to table 2)

pc.

Gasket

Chambersize: 3 in.

Float

Terminal connection(Terminal screw size: M4)

refer to table 1

M4 Terminal screwfor grounding

Electric conduitconnection port

Mounting position: right sideNote 1

drain plug

Case

Table 1. Terminal Table 2. Bolt / nut material Table 4. Size H

Symbol DescriptionS+, S- Power suuply and output signalCHK+, CHK- Terminal for check meterM+, M- Terminal for ammeter installed outsideE Ground terminal

Bolt / nut materialU, M, A, E SNB7 / S45C *D, W SUS304/SUS304

Measuring range (mm) H 0 to 300 300 0 to 350 350 0 to 400 400 0 to 500 500 0 to 600 600 0 to 700 700 0 to 800 800 0 to 1000 1000 0 to 1200 1200 0 to 1500 1500 0 to 2000 2000

Table 3. Connecting flange size

* When Y131 is specified, bolt/nut material shall be SUS304/SUS304.

40 mm50 mm1 1/2 in.

2 in.40 mm50 mm40 mm50 mm1 1/2 in.

2 in.

D140155127152140155160165155165

G8196

73.291.9819690

10573.291.9

T161618

19.51818222221

22.5

f22

1.61.62222

1.61.6

C10512098.6

120.6105120120130

114.3127

H-N19-419-416-419-419-419-823-419-822-419-8

Flange rating

JIS 10 K RF

JIS 20 K RF

JIS 30 K RF

JPIANSI

150 RF

JPIANSI

300 RF

Note 2

)(Optional)

(with indicator)(without indicator)

External adjustment switch(when with indicator)

Page 17: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Azbil Corporation No. SS2-SLX100-0100

- 17 -

Internal float typeT: Top connection [Unit: mm]

Note) 1: When pressure rating is JIS 10K, hub shown in the figure above will not be provided.

(Standard, with indicator)(Standard, without indicator)(for high temperature, with indicator)(for high temperature, without indicator)

(Standard)(for high temperature)

Housing Sensor housingTorque tubehousing

Extension

Bonnet

Bolt / nut(refer to table 2)

pc.

Gasket

Float

Terminal connection(Terminal screw size: M4)

refer to table 1

M4, Terminal screwfor grounding

Electric conduitconnection port

Mounting position: right side

Note 1

(Refer to table 4)

Table 1. Terminal Table 2. Bolt / nut material Table 4. Size H

Symbol DescriptionS+, S- Power suuply and output signal terminalCHK+, CHK- Terminal for check meterM+, M- Terminal for ammeter installed outsideE Ground terminal

Bolt / nut materialU, M, A, E SNB7 / S45C *D, W SUS304/SUS304

Measuring range (mm) H 0 to 300 300 0 to 350 350 0 to 400 400 0 to 500 500 0 to 600 600 0 to 700 700 0 to 800 800 0 to 1000 1000 0 to 1200 1200 0 to 1500 1500 0 to 2000 2000

Table 3. Connecting flange size

* When Y131 is specified, bolt/nut material shall be SUS304/SUS304.

80 mm100 mm125 mm

3 in.4 in.5 in.

80 mm100 mm125 mm80 mm

100 mm125 mm

3 in.4 in.5 in.

D185210250190229254200225270210240275210254279

G126151182127

157.2185.6132160195140160195127

157.2185.6

T181820242424222426283236

28.532

35.5

f222

1.61.61.6222222

1.61.61.6

C150175210

152.4190.5215.9160185225170195230

168.1200.2235

H-N19-819-823-819-419-822-823-823-825-823-825-825-822-822-822-8

Flange rating

JIS 10K RF

JIS 20K RF

JIS 30K RF

JPIANSI

150 RF

JPIANSI

300 RF

Case

(Optional)

(with indicator)(without indicator)

External adjustment switch(when with indicator)

Page 18: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

No. SS2-SLX100-0100 Azbil Corporation

- 18 -

Cautions for handling the product

In order to ensure maximum performance from the product's functions, please handle it properly while paying attention to the following precau-tions. Please make sure that you read the instruc-tion manual of this product before use.

Cautions for installation

� WARNING

• When installing, make sure that the gasket between process connections (flange connec-tions) does not protrude; otherwise fluid leak-age or output error may occur.

• Do not operate the instrument beyond the specified pressure, temperature or conditions. Could result in damage to the instrument or fluid leakage which may lead to a serious accident.

• Wiring installation in an explosion-proof area must be done in accordance with the proce-dures stated in the explosion-proof guideline. For an explosion-proof model with explo-sion-proof cable gland adaptor, make sure that an Azbil Corporation-made certified explosion-proof cable gland adaptor is used. The cable for wiring should have a 60 °C

withstanding temperature or higher.*1

Note *1) If temperature class is as listed below, use cables with higher allowable temperature rating:

Temp. class Maximum allowable temperatureT3 70°CT4 65°C

� CAUTION

• Do not use this instrument as a step or scaf-fold after installation. The instrument may be damaged and this may result in injury.

• Do not hit indicator's glass window with any tool or hard object. Broken glass may cause the injury.

• Make sure that installation has been per-formed properly. If not, it may result in output error or violation of industry regulations.

• This instrument is heavy. Be careful on scaf-fold and wear safety shoes.

� WARNING

• Do not perform wiring with wet hands or while the power supply is on. This may result in electric shock.

� CAUTION

• Make sure that wiring is done properly and checked thoroughly. Incorrect wiring may damage the instrument.

• Make sure that the power supply conforms to specifications and is used properly. An incor-rect power supply will damage the instru-ment.

When ordering, please specify each of the fol-lowing:1) Model number (attach suffix “Z” to the end

of basic model number for hydrometer.2) Name of gas or fluid, type of gas, design

temperature, pressure (in particular instru-ment for High Pressure Gas Law certifica-tion).

3) Specific gravity of fluid, its pressure, tem-perature.

4) Dimension from bottom of flange to top of float (L1)

5) For hydrometer application (range of spe-cific gravity measurement)

6) For interface measurement application (spe-cific gravities of upper and lower fluid)

7) Additional specifications.

Page 19: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly
Page 20: Smart Displacement type Level Transmitter 1 - 6th edition No. SS2-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly

Please, read ‘Terms and Conditions’ from following URL beforethe order and use.

http://www.azbil.com/products/bi/order.html

(11)

1-12-2 Kawana, Fujisawa

Kanagawa 251-8522 Japan

http://www.azbil.com/

Specifications are subject to change without notice.

No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.

1st edition: June 20016th edition: July 2015