SMARTONLINE™ 3-PHASE UPS SYSTEMS •220/380,230/400or240/415VAC
TheMostReliableandCost-EffectivePowerSolutionsforYourDataCenter
SMARTONLINE E3 SERIES (20-80KVA)
IDEAL OUTPUT POWER PROTECTSCRITICALSYSTEMS
MODULAR ARCHITECTURE ELIMINATESDOWNTIME
1-TO-1 GENERATOR SIZING LOWERSINSTALLATIONCOSTS
EXTREME EFFICIENCY LOWERSOPERATINGCOSTS
SMARTONLINE T3 SERIES (30KVA)
RELIABLE OPERATION KEEPSEQUIPMENTPOWERED
VERSATILE BATTERY SYSTEM EXPANDSRUNTIMEOPTIONS
SUPPORT UP TO
320 KVA IN PARALLEL
SMARTONLINE E3 SERIES UPS SYSTEMSExtremely efficient protection for your most important equipment
IDEAL OUTPUT POWER PROTECTSCRITICALSYSTEMSOn-line, double conversion operation continuously delivers precision-regulated, pure sine wave output, isolating your critical systems from damaging and disruptive power problems.
MODULAR ARCHITECTURE ELIMINATESDOWNTIMEInternal N+1 power module redundancy, parallel capability (up to four units) and fault-tolerant bypass features keep your critical systems highly available and productive around the clock.
1-TO-1 GENERATOR SIZING LOWERSINSTALLATIONCOSTSAn advanced IGBT rectifier produces best-in-class <4% THDi (input Total Harmonic Distortion), eliminating costly over-sizing requirements for generators, breakers and cables.
EXTREME EFFICIENCY LOWERSOPERATINGCOSTSEfficiency up to 97% significantly lowers power and cooling costs compared to multiple smaller units or legacy high-capacity units.
2
RELIABLE OPERATION KEEPSEQUIPMENTPOWEREDOn-line operation and fault-tolerant bypass features keep your equipment powered at all times.
VERSATILE BATTERY SYSTEM EXPANDSRUNTIMEOPTIONSA hot-swappable battery system with convenient front-panel access allows you to customize battery backup runtime.
SMARTONLINE T3 SERIES UPS SYSTEMSReliable protection for small and mid-range installations
C O N T E N T S
C O N T E N T S
SMARTONLINE E3 SERIES UPS SYSTEMS
SU80KX 80kVA/64kW
SU60KX 60kVA/48kW
SU40KX 40kVA/32kW
SU20KX 20kVA/16kW
IDEAL OUTPUT POWER 3MODULAR ARCHITECTURE 3PARALLEL FEATURES 31-TO-1 GENERATOR SIZING 4EXTREME EFFICIENCY 4GREEN POWER 4 MONITORING AND CONTROL 5 BATTERY CABINETS 5 COMPACT FOOTPRINT 6ORDERING INFORMATION 6TECHNICAL SPECIFICATIONS 7
SMARTONLINE T3 SERIES UPS SYSTEMSSU30K3/3INT 30kVA / 24kW
TECHNICAL SPECIFICATIONS 7 RELIABLE OPERATION 8VERSATILE BATTERY SYSTEM 8ORDERING INFORMATION 8
IDEAL OUTPUTPOWERSmartOnline E3 Series UPS Systems isolate your critical equipment from power problems, including surges, line noise, harmonic distortion, electrical impulses, frequency variations, brownouts, overvoltages and blackouts. True on-line operation continually transforms AC input power into filtered DC power, then resynthesizes it into precision-regulated AC output with a pure sine wave. Strong overload capacity supports up to 150% output for up to 60 seconds. Reliable backup power with zero transfer time to battery keeps equipment operating safely through shorter power failures and allows time to shut down or switch to generator power during longer outages. Rapid recharging restores battery charge levels in as little as two hours.
MODULAR ARCHITECTUREIntelligent, independent 20 kVA power modules provide internal redundancy. When the UPS is configured for N+1 redundancy, convenient hot-swap power modules can be replaced without powering down the connected load. In the event of a power module fault, the load is automatically distributed among the remaining modules. Because load redistribution happens without interrupting critical systems, mean time to recovery is zero—far superior to legacy UPS systems. In addition, redundant control circuits eliminate a single point of failure commonly found in less-reliable UPS designs. Dual input connections provide an additional level of redundancy by allowing each UPS system to be powered by two separate utility sources.
If service or repair requires UPS shutdown, all models include a manual bypass breaker and automatic bypass function that maintain system availability by passing through AC power until the UPS system returns to service.
PARALLEL FEATURESIncrease fault tolerance or quadruple output capacity by connecting up to four SmartOnline E3 Series UPS Systems in parallel. If one UPS system is taken offline for maintenance, the other UPS systems automatically compensate to support the equipment load—without requiring additional programming.
SmartOnline E3 Series UPS Systems ship ready for parallel operation. Patented dual-DSP technology provides optimal synchronization of power sources.
External Battery Cabinet 80 kVA UPS System
60 kVALoad
20 kVARedundancy
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
20 kVAPower Module
MODULAR DESIGN ARCHITECTURE INTERNAL N+1 REDUNDANCY
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
240 kVALoad
320 kVALoad
PARALLEL FOR N+1 REDUNDANCY
PARALLEL TO MAXIMIZE CAPACITY
80 kVA80 kVA 80 kVA 80 kVA
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
80 kVAUPS System
240 kVALoad
320 kVALoad
PARALLEL FOR N+1 REDUNDANCY
PARALLEL TO MAXIMIZE CAPACITY
80 kVA80 kVA 80 kVA 80 kVA
Four 80 kVA SmartOnline E3 Series UPS Systems can provide backup power for a 320 kVA load.
Four 80 kVA SmartOnline E3 Series UPS Systems can provide redundant backup power for a 240 kVA load.
In an N+1 configuration, the supported load is at least 20 kVA less than the maximum output capacity of the UPS system. For example, an 80 kVA UPS is configured for N+1 redundancy when the connected load is 60 kVA or less.
SMARTONLINE E3 SERIES UPS SYSTEMS
3
1-TO-1 GENERATORSIZINGSmartOnline E3 Series UPS Systems have
a generator-friendly design that decreases
installation costs. A high input power
factor and IGBT rectifier with DSP control
create less than 4% input Total Harmonic
Distortion (THDi). Low THDi enables cost-
saving 1-to-1 sizing of UPS systems to
generators, allows generators to run cooler
and extends the operational lifespan of all
input components. Low THDi also reduces
sizing requirements for cables and breakers
and improves reliability by eliminating
nuisance breaker tripping and overheated
transformers.
Legacy UPS Energy Usage (MWh)
SmartOnline E3 Energy Usage (MWh)
Legacy UPS CO2 Emissions (Metric Tons)
SmartOnline E3 CO2 Emissions (Metric Tons)
CUMULATIVE ENVIRONMENTAL IMPACT OVER FIVE YEARS
1956
1752
11881065
1
3911
3504
2378
2130
2
5867
5256
3566
3195
3
78237008
47554259
4
97798760
5944
5324
5
GREEN POWEREfficient SmartOnline E3
Series UPS Systems save
energy and reduce your
carbon footprint. Replacing
160 kVA of legacy UPS
capacity can reduce CO2 emissions by
123 metric tons and save more than 200
megawatt-hours* of electricity per year—
enough to power 16 single-family homes.
An extremely wide voltage correction
range reduces battery wear up to 40%,
so batteries last longer. Batteries are also
recyclable and contain a high percentage
of recycled materials, creating an efficient
manufacturing loop that conserves
resources and reduces landfill waste.
Tripp Lite also restricts hazardous
substances during manufacture,
maintaining industry leadership
in RoHS compliance.
* 1 megawatt-hour = 3,6 gigajoules.
EXTREME EFFICIENCYAdvanced high-utilization IGBT inverter technology and high-speed DSP control provide
superior operating efficiency at all load levels—up to 97% in economy mode. Increasing
efficiency lowers UPS system operating costs by reducing electricity consumption, heat
emissions and cooling costs. Replacing 160 kVA of legacy UPS capacity with SmartOnline
E3 UPS Systems can save more than US$20 000 per year.
In addition, SmartOnline E3 Series UPS Systems automatically correct the widest range of
incoming voltages in their class. The wide voltage window and temperature-compensated
charging combine to decrease battery wear significantly, extending service life and
reducing replacement costs.
The extreme efficiency of SmartOnline E3 Series UPS Systems can reduce your data center’s power costs significantly. Replacing 160 kVA of
legacy capacity can save more than US$20 000 per year.SmartOnline E3 Series UPS Systems reduce
installation costs up to 30% versus legacy UPS systems.
INSTALLATION COST COMPARISON
Generators
Cabling
Breakers
Related Costs
Cost
Smar
tOnl
ine
E3
Leg
acy
UPS
SmartOnline E3
Legacy UPS
100%
85%
70%
50% 75% 100%
SmartOnline E3 SeriesExtreme EfficiencyAdvantage
LOAD
EFF
ICIE
NC
Y
EFFICIENCY CHART
Replacing 160 kVA of legacy UPS capacity with SmartOnline E3 Series UPS Systems can save 200 megawatt-hours* and reduce CO2 emissions by 123 metric tons (enough to offset 2 000+ flights from London to Paris) per year.
4
Convenient communication and management
features allow you to monitor power
conditions, receive automatic alerts and control
SmartOnline E3 Series UPS Systems with
drift-proof digital precision from any distance.
• CONTACTCLOSUREINTERFACE
Connects to an Emergency Power Off (EPO)
circuit for emergency UPS system shutdown.
Also allows the UPS system to monitor
external battery cabinets and communicate
operational messages.
• RS-232SERIALPORT
Connects to a server for shutdown
commands and reporting through
PowerAlert software (included).
• ACCESSORYCARDSLOT
Optional network card (SNMPWEBCARD)
provides remote monitoring and
control. Optional environmental
sensor (ENVIROSENSE) monitors
temperature, humidity and more.
• NETWORKPOWERMANAGEMENT
You can manage UPS systems with
PowerAlert Network Management
System (included) or a third-party
network management system.
• LED/LCDCONTROLPANEL
Offers convenient push button control
and communicates operational modes,
conditions and warnings.
BATTERY CABINETSAll SmartOnline E3 Series UPS Systems can connect to external battery cabinets:
• ModelsSU20KXandSU40KXincludeinternalbatteriesanddonotrequire external battery cabinets, but external battery cabinets can be added to expandruntime.ModelSU20KXalsohasroomtoaddtwoadditional SURBC2030 internal battery packs.
• ModelsSU60KXandSU80KXdonothaveinternalbatteriesandrequirean external battery cabinet. Additional battery cabinets can be connected to expand runtime.
External battery cabinets are available in a variety of capacities. Models BP480V26B and BP480V40C support temperature-compensated charging foroptimal charge levels and increased battery lifespan. They also match the appearance and footprint of the UPS system cabinets. Larger models have heavy-gauge steel cabinets with 10-year design life batteries. SmartOnline E3 Series UPS Systems handle large battery systems with ease, providing up to 20 amps* of user-selectable charging capacity. * Varies with model.
Real-Time Power Status Consoles
POWERALERT NETWORK MANAGEMENT SYSTEM
PowerAlert allows you to manage up to 250 UPS systems from a single workstation.
MONITORING AND CONTROL
BP480V40CBP480V26B
The LED/LCD control panel provides detailed UPS status information.
The rear panel includes several communication interfaces.
Parallel Interface
RS-232 Serial Port
Accessory Card Slot
Contact Closure Interface
5
6
ORDERING INFORMATIONMODEL OUTPUT CAPACITY NOMINAL INPUT/OUTPUT VOLTAGE BATTERY CONFIGURATION
SU20KX 20kVA/16kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)
Internalbatteries;roomfortwoadditionalSURBC2030internalbatterypacks;externalbatterycabinetoptional.
SU40KX 40kVA/32kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)
Internalbatteries;externalbatterycabinetoptional.
SU60KX 60kVA/48kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)
Nointernalbatteries;externalbatterycabinetrequired.
SU80KX 80kVA/64kW 220/380,230/400or240/415VAC (3Ø,4-wire+ground,wye)
Nointernalbatteries;externalbatterycabinetrequired.
EXTERNALBATTERYCABINETS (Hardwire connection. Multiple cabinets can be daisy-chained.)
BP480V26B +/-240VDCexternalbatterycabinet.Supportstemperature-compensatedbatterychargingforoptimalchargelevelsandincreasedbatterylifespan.MatchesappearanceandfootprintofUPSsystemcabinet.
BPE480VB Empty+/-240VDCexternalbatterycabinet(similartoBP480V26Bwithoutbatteries).Requires40user-suppliedbatteries(12VDC/26Ah).Includeswiringandfuses.MatchesappearanceandfootprintofUPSsystemcabinet.
BP480V40C +/-240VDCexternalbatterycabinet.Supportstemperature-compensatedbatterychargingforoptimalchargelevelsandincreasedbatterylifespan.MatchesappearanceandfootprintofUPSsystemcabinet.
BPE480VC Empty+/-240VDCexternalbatterycabinet(similartoBP480V40Cwithoutbatteries).Requires40user-suppliedbatteries(12VDC/40Ah).Includeswiringandfuses.MatchesappearanceandfootprintofUPSsystemcabinet.
BP480V55 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.
BP480V78 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.
BP480V103 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.
BP480V140 +/-240VDCexternalbatterycabinet.Heavy-gaugesteelcabinetwith10-yeardesignlifebatteries.
SURBC2030 240VDCinternalbatterypackforSU20KX.
WALL-MOUNTEDEXTERNALMAINTENANCEBYPASSPANELSWITHKEYEDSAFETYINTERLOCKSYSTEM
SU20KMBPK MaintenancebypasspanelforSU20KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.
SU40KMBPKX MaintenancebypasspanelforSU40KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.
SU60KMBPKX MaintenancebypasspanelforSU60KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.
SU80KMBPKX MaintenancebypasspanelforSU80KXonly.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.
WALL-MOUNTEDPARALLELDISTRIBUTIONPANELS (Required for parallel connection of UPS systems.)
SUPT20KX ParalleldistributionpanelforparallelconnectionofSU20KXmodelsonly.
SUPT40KX ParalleldistributionpanelforparallelconnectionofSU40KXmodelsonly.
SUPT60KX ParalleldistributionpanelforparallelconnectionofSU60KXmodelsonly.
SUPT80KX ParalleldistributionpanelforparallelconnectionofSU80KXmodelsonly.
POWERMANAGEMENTACCESSORIES
SNMPWEBCARD AddsEthernetnetworkinterfacetoUPSsystemforremotemonitoringandcontrolviaSNMP,Webortelnet.
ENVIROSENSE Monitorstemperatureandhumidity.Monitorsuptothreeadditionalsensorsviacontactclosureinterface. RequiresSNMPWEBCARD.
WARRANTIESANDSERVICES
Sitesurveyservices,start-upservices,preventivemaintenanceservices,extendedwarrantiesandon-sitewarrantiesareavailable. Visitwww.tripplite.comorcontactyourTrippLitesalesrepresentativeformoreinformation.
COMPACT FOOTPRINTEach SmartOnline E3 Series UPS System packs enough power for multiple
racks of equipment into a compact footprint, saving valuable data center
floor space for critical systems and cooling. Wall-mounted distribution and
bypass panels do not require additional floor space.
INP
UT
MODEL SU20KX SU40KX SU60KX SU80KX SU30K3/3INT
NOMINAL VOLTAGE User-Selectable:220/380,230/400or240/415VAC(3Ø,4-wire+ground,wye)
VOLTAGE RANGE FullLoad:173/300–276/477VAC(-25% / +20% @ 230/400 VAC)
≤70%Load:120/208–276/477VAC(-48%/+20%@230/400VAC)176/304– 288/499VAC
THDi (Full Load) <4%
POWER FACTOR (On-line, Full Load) >0,99 >0,95
FREQUENCY (Auto-Selectable) 50/60Hz
FREQUENCY TOLERANCE ±5% ±3%
NOMINAL CURRENT
(@380/400/415VAC,PerPhase)26/25/24A 53/50/48A 79/76/73A 105/101/97A 45/43/41A
OU
TPU
T
CAPACITY (VA) 20000VA 40000VA 60000VA 80000VA 30000VA
CAPACITY (Watts) 16000W 32000W 48000W 64000W 24000W
POWER FACTOR 0,8PerPhase
NOMINAL VOLTAGE User-Selectable:220/380,230/400or240/415VAC(3Ø,4-wire+ground,wye)
FREQUENCY 50/60Hz±0,05Hz 50/60Hz±0,1Hz
NOMINAL CURRENT
(@380/400/415VAC,PerPhase)30/29/28A 61/58/56A 91/87/83A 121/116/111A 46/43/42A
WAVEFORM (On-line or Battery) PureSineWave
THD (Linear Load) ≤3%
VOLTAGE REGULATION (Static) ±1% ±2%
OVERLOAD CAPACITY ≤125%for10minutes;≤150%for60seconds ≤125%for60sec; ≤150%for30sec
BR
EA
KE
RS
RECTIFIER (3-Pole, 600 VAC) 50A 75A 125A 150A 63A
BYPASS (3-Pole, 600 VAC) 50A 75A 125A 150A 63A
RESERVE (3-Pole, 600 VAC) 50A 75A 125A 150A -
OUTPUT (3-Pole, 600 VAC) 50A 75A 125A 150A -
BATTERY (Negative Pole, 600 VDC) 60A 120A 160A 220A -
GE
NE
RA
L
STANDARD INTERFACE LED/LCDControlPanel,RS-232,ContactClosure,EPO(LocalandRemote) Sameasleft,plusAS/400.
OPTIONAL INTERFACE SNMPWEBCARD,ENVIROSENSE,RELAYIOCARD
UPS TOPOLOGY TrueOn-line,DoubleConversion;Voltage/FrequencyIndependent(VFI-SS-111)Operation; ComplieswithEUDirectives(EN62040-3)
AGENCY APPROVALS CE(EN62040-1-1,EN62040-2,EN62040-3,IEC61000-4-2,IEC61000-4-3, IEC61000-4-4,IEC61000-4-5,IEC61000-4-6),RoHS
CE(Sameasleft),GOST,SASO
EFFICIENCY NormalMode:Upto94%/EconomyMode:Upto97% Upto93%
TRANSFER TIME (Normal Mode) 0ms
AMBIENT OPERATING TEMPERATURE 0°Cto40°C(32°Fto104°F)
ELEVATION 0to3000m(0to10000ft)
HUMIDITY (Non-Condensing) ≤90% ≤95%
AUDIBLE NOISE (@ 1 m) <70dBA <65dBA
TYPICAL RUNTIME* (Half/Full Load) 13/5,5+min(InternalBatteries)
13/5,5+min(InternalBatteries)
14/5,5+min(WithBP480V26B)
10/3,5+min(WithBP480V40C)
13/5+min(InternalBatteries)
DIMENSIONS (Power Module)
Height 1165mm(45,9in) 1165mm(45,9in) 1165mm(45,9in) 1165mm(45,9in) 897mm(35,3in)
Width 520mm(20,5in) 520mm(20,5in) 520mm(20,5in) 520mm(20,5in) 490mm(19,3in)
Depth 855mm(33,7in) 855mm(33,7in) 855mm(33,7in) 855mm(33,7in) 940mm(37,0in)
UNIT WEIGHT** (Power Module) 267kg(589lb) 412kg(908lb) 210kg(463lb) 244kg(538lb) 284kg(627lb)
SHIPPING WEIGHT** (Power Module) 335kg(739lb) 480kg(1058lb) 278kg(613lb) 312kg(688lb) 324kg(715lb)
*Runtimevarieswithload,batteryconditionandotherfactors.Runtimecanbeextendedbyconnectingadditionalinternalbatteries(modelsSU20KXandSU30K3/3INTonly)or external battery cabinets, sold separately. ** WeightincludesinternalbatteriesformodelsSU20KX,SU40KXandSU30K3/3INT.
TECHNICAL SPECIFICATIONS
7
RELIABLE OPERATIONSmartOnline T3 Series UPS Systems protect your equipment from power problems,
including surges, line noise, harmonic distortion, electrical impulses, frequency variations,
brownouts, overvoltages and blackouts. On-line operation continually transforms AC
input power into filtered DC power, then resynthesizes it into precision-regulated AC
output with a pure sine wave. Reliable backup power with zero transfer time to battery
keeps equipment operating safely through shorter power failures and allows time to
shut down or switch to generator power during longer outages. Fault-tolerant bypass
features keep your equipment powered at all times—even if the UPS system requires
maintenance, repair or replacement.
VERSATILE BATTERYSYSTEMSmartOnline T3 Series UPS Systems have an expandable, hot-swappable battery system
withconvenientfront-panelaccess.ModelSU30K3/3INTincludesthreeinternalbattery
packs and has room to add one additional SURBC2030 battery pack. Runtime can also
be expanded with external battery cabinets. Each SUBF2030 external battery cabinet
has room for up to four SURBC2030 battery packs.
SMARTONLINE T3 SERIES UPS SYSTEMS
Expand battery backup runtime by installing additional internal battery packs and/or
external battery cabinets.
SU30K3/3INT
SUBF2030 External Battery Cabinet
SURBC2030 Internal Battery Pack
+ _+ _
+ _OPEN
OPEN OPEN
OPEN OPEN
ORDERING INFORMATIONMODEL OUTPUT CAPACITY BATTERY CONFIGURATION
SU30K3/3INT 30kVA/24kW Includesthreeinternalbatterypacks;roomforoneadditionalSURBC2030batterypack.
BATTERYEXPANSION (Multiple battery cabinets can be daisy-chained.)
SURBC2030 240VDCinternalbatterypackforSmartOnlineT3UPSSystemsandSUBF2030externalbatterycabinets.
SUBF2030 Externalbatterycabinet.RequiresSURBC2030batterypacks(uptofourpercabinet),soldseparately.
BP240V99 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.
BP240V120 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.
BP240V1207C 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.Built-inbatterycharger.
BP240V150 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.
BP240V1507C 240VDCexternalbatterycabinetwith10-yeardesignlifebatteries.Built-inbatterycharger.
WALL-MOUNTEDEXTERNALMAINTENANCEBYPASSPANELSWITHKEYEDSAFETYINTERLOCKSYSTEM
SU30KMBPK Maintenancebypasspanelfor30kVAmodels.Keyedsafetyinterlocksystempreventssequenceofoperationerrors.
POWERMANAGEMENTACCESSORIES
SNMPWEBCARD AddsEthernetnetworkinterfacetoUPSsystemforremotemonitoringandcontrolviaSNMP,Webortelnet.
ENVIROSENSE Monitorstemperatureandhumidity.Monitorsuptothreeadditionalsensorsviacontactclosureinterface. RequiresSNMPWEBCARD.
RELAYIOCARD Programmablecontactclosureaccessorycardwithsixoutputcontactsandoneinputcontact.
WARRANTIESANDSERVICES
Sitesurveyservices,start-upservices,preventivemaintenanceservices,extendedwarrantiesandon-sitewarrantiesareavailable. Visitwww.tripplite.comorcontactyourTrippLitesalesrepresentativeformoreinformation.
ABOUT TRIPP LITESince 1922, Tripp Lite has established a global reputation for qualitymanufacturing, superior value and excellent service. Tripp Litemakes more than 1000 products to power, protect and connectelectronic equipment, including UPS systems, replacement batteries,power distribution units, rack systems, surge suppressors, KVMswitches, cables, laptop accessories, power strips and inverters. Learnmoreatwww.tripplite.com.
Copyright © 2009 Tripp Lite. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from final products.
20080224095-2917