smokejet - termodinair · the smokejet is equipped with an automatic thermal release mechanism...

12
SMOKEJET Universal Louvre Ventilator

Upload: vandung

Post on 18-Sep-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

SMOKEJET

Universal Louvre Ventilator

The universal louvre

ventilator SMOKEJET is being

installed in industrial, commercial

and community buildings. Due to

its great stability, its low weight

and the extensive possibilities of

application, the SMOKEJET is

always appreciated by architects

and builders.

SMOKEJET BENEFITS:

� Fire prevention / smoke and heat extraction

� Day-to-day ventilation

� Natural daylight

� Energy conservation

� For all conventional roof and

wall construction types

SMOKEJET

The SMOKEJET fulfils the standard

requirements regarding heat

insulation, wind forces and

snow loads.

It can also be integrated into any

walls as an additional air inlet

system.

FIRE PROTECTIONFOR YOUR SAFETY

The SMOKEJET is equipped with an automatic

thermal release mechanism (thermal priority

valve as requested by the regulations

VdS 2159 and DIN 18232).

In the event of fire, when reaching the

release temperature SMOKEJET opens

independent from all other functions.

PREVENTIVE FIREPROTECTION

The fire risk has encreased enormous

by using more plastic material in

production halls which release, when

burning toxic gases in combination

with smoke and heat. Only venting

in the early stage of a fire will

prevent a catastrophe - allows

people to evacuate and makes

effective fire fighting possible.

SMOKEJET in northlight glazing

SMOKEJET integrated into the skylight System DELTALIGHT

SMOKEJET installed in a flat roof

VENTILATION

Especially in the summer month the heat

load from plant heat and solar heat result

in ventilation problems and so cause

bad working conditions.

The universal louvre ventilator

provides lots of fresh air and creates

a good working climate.

SMOKEJET can also be integrated into

any wall construction as an additional

air inlet system. In case of a fire

SMOKEJET in walls can also be used

as natural inlet to make the smoke and

heat exhaust ventilation more effective.

At the same time the materials situated

close to the fire are cooled down by

the air stream of inlet air.SMOKEJET fixed in vertical northlight glazing

SMOKEJET integrated into the domelight system EUROLIGHT

SMOKEJET in northlight glazing

SMOKEJET in vertical glazing

SMOKEJET

SMOKEJET in northlight glazing

ENERGY CONSERVATION

The energy factor plays an important role

particularly for industrial companies.

Especially during the winter leakage leads

to large heat losses, if ventilators are not tight.

This is why seal-brushes at the louvres

and at the unit frames keep the heat loss at a

minimum when the Smokejet is closed.

THE SOLUTION - FOR „COOL CALCULATORS“

Even in a closed position natural daylight

enters the building due to the transparent

louvre blades. This saves energy costs for

artificial lighting and has a positive

motivation effect on employees.

SMOKEJET’S active contribution to energy

conservation assists the amortisation of the

plant.

A1Single-skinned aluminium louvre

A2Double-skinned aluminium louvre

PCDouble-skinned polycarbonate louvre

GLSingle-skinned laminated safety glass (VSG)

SMOKEJET is made from corrosion resistant

aluminium alloy AIMg3.

The following types of louvres are available

due to the installation conditions and the

industrial invironment.

LOUVRE TYPES

1. Base profile2. Pneumatic cylinder3. Connecting rod4. Louvres5. Unit flange

SMOKEJET ADVANTAGES IN DETAIL

The rain sensor provides

weatherproof ventilation.

The louvres close

automatically when

rain is detected.

rain detector

INSTALLATION

Due to its low weight and almost any possible

dimensions and flange models the Smokejet

universal louvre ventilator can be easily

adapted to any kind of roof or facade.

SMOKEJET FLEXIBLE AND RELIABLE

F1 –Installed in glazing

F2 –Installed under profiledroof

F3 – Installed on profiled roof

F4 –Installed directly into rooffelt

F5 –Installed on an upstand

FLANGE VERSIONS:

SMOKEJET integrated into dome-light system EUROLIGHT withpolycarbonate louvres. Unit flange prepared for installation (F5) ontoan upstand.

SMOKEJET on a flat roof with insulated upstand and aluminiumlouvres. The unit flange is prepared for installation (F5) onto anupstand.

SMOKEJET in northlight glazing with reinforced wire glass. Unitflange prepared for installation (F1 or F2) into glazing.

Unit size standard (F5)Geometric free area and aerodynamic free area

System type Unit dimensions Flange dimensions Ag AwSMOKEJET width length width length m2 m2

in mm = B L C D

JA 05-0607 576 705 830 960 0,406 0,305JA 07-0610 576 971 830 1230 0,559 0,392JA 09-0612 576 1237 830 1490 0,713 0,499JA 11-0615 576 1503 830 1760 0,866 0,606JA 13-0618 576 1769 830 2020 1,019 0,713JA 15-0620 576 2035 830 2290 1,172 0,821JA 17-0623 576 2301 830 2560 1,325 0,928JA 19-0625 576 2500 830 2820 1,440 1,008

JA 05-0707 726 705 980 960 0,512 0,384JA 07-0710 726 971 980 1230 0,705 0,493JA 09-0712 726 1237 980 1490 0,898 0,629JA 11-0715 726 1503 980 1760 1,091 0,764JA 13-0718 726 1769 980 2020 1,284 0,899JA 15-0720 726 2035 980 2290 1,477 1,034JA 17-0723 726 2301 980 2560 1,671 1,169JA 19-0725 726 2500 980 2820 1,815 1,271

JA 05-1007 1026 705 1280 960 0,723 0,506JA 07-1010 1026 971 1280 1230 0,996 0,697JA 09-1012 1026 1237 1280 1490 1,269 0,888JA 11-1015 1026 1503 1280 1760 1,542 1,079JA 13-1018 1026 1769 1280 2020 1,815 1,270JA 15-1020 1026 2035 1280 2290 2,088 1,462JA 17-1023 1026 2301 1280 2560 2,361 1,653JA 19-1025 1026 2500 1280 2820 2,565 1,795

JA 05-1307 1326 705 1580 960 0,935 0,654JA 07-1310 1326 971 1580 1230 1,288 0,902JA 09-1312 1326 1237 1580 1490 1,640 1,148JA 11-1315 1326 1503 1580 1760 1,993 1,395JA 13-1318 1326 1769 1580 2020 2,346 1,525JA 15-1320 1326 2035 1580 2290 2,698 1,754JA 17-1323 1326 2301 1580 2560 3,051 1,983JA 19-1325 1326 2500 1580 2820 3,315 2,155

JA 05-1607 1626 705 1880 960 1,146 0,802JA 07-1610 1626 971 1880 1230 1,579 1,105JA 09-1612 1626 1237 1880 1490 2,011 1,307JA 11-1615 1626 1503 1880 1760 2,444 1,589JA 13-1618 1626 1769 1880 2020 2,876 1,869JA 15-1620 1626 2035 1880 2290 3,309 2,151JA 17-1623 1626 2301 1880 2560 3,741 2,432JA 19-1625 1626 2500 1880 2820 4,065 2,642

JA 05-1907 1926 705 2180 960 1,358 0,951JA 07-1910 1926 971 2180 1230 1,870 1,309JA 09-1912 1926 1237 2180 1490 2,386 1,551JA 11-1915 1926 1503 2180 1760 2,895 1,882JA 13-1918 1926 1769 2180 2020 3,407 2,215JA 15-1920 1926 2035 2180 2290 3,919 2,547JA 17-1923 1926 2301 2180 2560 4,432 2,881JA 19-1925 1926 2500 2180 2820 4,815 3,130

TECHNICAL SPECIFICATIONS

Depending on the complexity of application and

location, there is a choice of different unit versions.

All SMOKEJETS comply with the requirements of

DIN18232 and VdS 2159.

pneumatic cylinder

Thermal priority valve (fusible link)

Version with 350 mm vertical upstand

The universal louvred ventilation and natural smoke and heat exhaustventilation system SMOKEJET for energy-free natural ventilation andsmoke and heat exhaust ventilation meets all demands of preventivefire precautions according to the DIN 18232 as well as VdSregulations 2159.

The construction is designed as a maintenance free, compact andlightweight louvred unit.

A multi-channel drainage system and the overlapping of the louvresguarantee a rain-proof system.

The ventilator side panels are reinforced by inner and outerlongitudinal profiles.

The units are made from corrosion resistant aluminium AlMg3. All another construction parts are corrosion-proof.

The louvres are controlled by a pneumatic cylinder with a specialpermanent lubricant.

In the event of fire the thermal release system releases automatically– independent from every other control mechanism via thermalpriority CO2 valve – or fusible link.

The louvres can be made from either aluminium, polycarbonate orglass in the different versions.

Due to its low weight, as well as its suitable dimensions and flangeversions, an easy installation into all customary roof and wallconstructions is possible.

SMOKEJET SPECIFICATION

Geometric free area: m2

Aerodynamic free area: m2

Weigth: kg

Releasing temperature: °C

Roof opening length: mm

Roof opening width: mm

Flange length: mm

Flange width: mm

WITH USIN BEST COMPANY

Would you like to findout more about us?

Just phone, fax or emailfor further assistance.

© C

op

yrig

ht

2004

M.P.

S.-W

erb

un

g L

an

ge

na

u-Ä

nd

eru

ng

en

vo

rbe

ha

lten

.