135
CIRCUIT BREAKERS
MODEL
B8003B8005B8007B8010B8015
CURRENT A
357
1015
RESISTANCE OHMS
.069
.030
.017
.011
.007
SNAP-IN CIRCUIT BREAKERPHILMORE’S NEW SNAP-IN CIRCUIT BREAKERSEND FUSE REPLACEMENT WORRIES
PUSH BUTTON CIRCUIT BREAKER
Easy to install. Where you use glass cartridge fuseholders, B-8000series can replace them without panel redesign or repunching. Thinkabout putting them out front. B-8000 series breakers can be prewiredand then snapped securely into the panel from the front.
A. 6.35mm terminals are plated and punched for quick connect ot solder connections. Easy to wire and install.
B. Special molded clips, snaps securely into standard 15.9mm panel cutouts. No redesign or repunching.
C. Trip indicator warns of a possible circuit problem. Choice of black or white
B7000 Series PUSH BUTTON THER-MAL CIRCUIT BREAKER
“B7000” Series breakers are UL 1077 recognized asSupplementary protectors, File E99607, and CSACertified as appliance Components protectors, FileLR62590.B7000 Series are single pole, thermal circuit breakersthat feature a recessed reset button which cannot bemanually pulled out to disconnect the circuit. When anoverload occurs and the breaker opens, it allows thereset button to “pop out” for visible trip indication.
No. B7000 - Clear plas-tic boot for Philmore No.B7000 - Series PushButton circuit breaker.Protects reset buttonfrom dust and moisture.
Part No.
B7003B7004B7005B7006B7007B7008B7010B7012B7015B7020B7025B7030B7035B7040B7045B7050
Amps
345678
10121520253035404550
MaximumResistance in
ohms.18
0.10.0260.15.020.020.014.010.010.006
0.005.004.004.004.002.002
Trip time @200% of rating
10-45 Seconds10-45 Seconds10-45 Seconds10-45 Seconds10-45 Seconds10-45 Seconds
6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds6 to 30 Seconds
Endurance: 1,000 times at leastCalibration: Breaker will continuously carry 100% of rated load.It may trip between 101% and 144% of rated load, but musttrip at 145% at 25º C.Dielectric Strength: Over 1,500 volts RMS.Max. Operating Voltages: 50VDC, 250VACInterrupt Capacity: 2,000 Amps, at 50 VDC(1-30 amp Models)
1,000 Amps, at 250VAC (1-30 amp Models)
B-8000 SERIES SPECIFICATIONTHERMAL CIRCUITBREAKERS-FUSE HOLDER TYPE
- SNAP-IN TO INSTALL-MANUALLY RESET
1. VOLTAGE : 32VDC, 250VAC2. RESET TIME : 180 SECONDS MAX3. ENDURANCE : 1,000 TIMES AT LEAST4. WEIGHT : ALMOST 10g
Approvals
* Approval: 3 -30 A 125/250 VACc
* Approval: 5A, 10A, 15A, 20A125 VAC