Solar Taurus 60 Mobile Power Units Return to Main Equipment Page Back to Generators Index Page Solar Taurus 60 Mobile Power Units (Pic1) Solar Taurus 60 Mobile Power Units (Pic2) Qty 12 (Available): Solar Taurus 60 Turbine Generators, Model T7300 Mobile Power Units, Package: XQ5200, Rated: 4.9 MW @ 50 HZ, 13400 Volts, Dual Fuel (Diesel #2 & Natural Gas), (9) Units have less than 500 Hours. Bill of Materials, Solar Taurus 60 Mobile Power Unit: The Solar Taurus 60 Mobile Power Unit is a "Truly Portable" 5200 KW generation system that is easy to move, easy to setup, easy to operate, easy to tear down, and easy on the pocketbook by avoiding high installation costs. The design features are outlined below. 1. Trailer transportable by permit. 2. No concrete slabs for placement of mobile generation system. 3. No large cranes or large fork lifts required to set up. 4. Setup in five days or less. 5. Quiet operation. 76dba @ 50 ft. 6. Minimum of auxiliary connections required. (i.e. gas powered units require a 12.47KV or 13.8KV connection & 250 pound gas connection). 7. Black start capability (requires 200 KW, 480vac power source) 8. High quality factory design, manufacturing, & testing by Solar

Upload: khaldoon-alnashi

Post on 18-Dec-2015

10 views

Category:

Documents


1 download

DESCRIPTION

turbine

TRANSCRIPT

Solar Taurus 60 Mobile Power UnitsReturn to Main Equipment PageBack to Generators Index Page

Solar Taurus 60 Mobile Power Units (Pic1)Solar Taurus 60 Mobile Power Units (Pic2)

Qty 12 (Available): Solar Taurus 60 Turbine Generators, Model T7300 Mobile Power Units, Package: XQ5200, Rated: 4.9 MW @ 50 HZ, 13400 Volts, Dual Fuel (Diesel #2 & Natural Gas), (9) Units have less than 500 Hours. Bill of Materials, Solar Taurus 60 Mobile Power Unit:The Solar Taurus 60 Mobile Power Unit is a "Truly Portable" 5200 KW generation system that is easy to move, easy to setup, easy to operate, easy to tear down, and easy on the pocketbook by avoiding high installation costs. The design features are outlined below.1. Trailer transportable by permit.2. No concrete slabs for placement of mobile generation system.3. No large cranes or large fork lifts required to set up.4. Setup in five days or less.5. Quiet operation. 76dba @ 50 ft.6. Minimum of auxiliary connections required. (i.e. gas powered unitsrequire a 12.47KV or 13.8KV connection & 250 pound gas connection).7. Black start capability (requires 200 KW, 480vac power source)8. High quality factory design, manufacturing, & testing by Solar Turbines Inc.There are currently over 1,000 Taurus turbines in service world wide.9. Low emissions output to meet today's stringent standards.Detailed Bill of MaterialsTurbine Generator Set Module:- Taurus 60 Gas Turbine with SoLoNOx, Dry Low NOx Combustion System- Epicyclic Reduction Gearbox, 1800 rpm output speed- Salient Pole, 3 Phase Generator with the follow characteristics:Rating. The generator is rated per NEMA standards so that the generator will not limit turbine performance over the range of site ambient temperatures.Generator standard features include: Sleeve Bearings with pressure fed sumps Six-lead WYE connection Terminal box Form wound stator windings Damper windings Rotor balance to 125% rated speed Permanent magnet pilot exciter Anti-condensation space heaters 300% short circuit capability for 10 seconds Overload capacity per NEMA: 150% rated current for 1 minute 110% for 2 hoursVoltage Regulator Characteristics Solid state Single-phase sensing 10% voltage adjustment range 0.5% steady state voltage regulation Reactive load sharing to within 5% nameplate rating Crosscurrent compensation capabilityWave Form Characteristics. Deviation Factor [maximum] 6% Harmonic Content [maximum] 3% Telephone Interference Factor 50 Balanced Residual 75Voltage Drift. The change in voltage will not exceed 1.0% over a 30 minuteperiod when the generator is operating at rated voltage and 0.8 to 1.0 power factor and with a constant load between no load and full rated load.Generator Construction. An open drip proof generator per NEMA standards isprovided.Generator Voltage. The generator output is 13,800 or 12,470 Volts, 3 phase, 60 Hz. Insulation conforms to NEMA class F with class F (1050C) temperature rise.- NEC, non-hazardous Electrical Classification- Direct AC Drive Start System- Lube Oil System:Tank, Filters, Pre/Post Lube Pump, Back-up Pump, Vent Separator- Vibration and Temperature Monitoring System- PLC based Control System with 120 VDC Battery Supply (installed on the Auxiliary Equipment Module)- Generator Control and Monitoring System with the following features and functions:Integrated monitoring and control of the generator is provided using a specially designed module in the PLC to receive input data from potential and current transformers. The system calculates real and reactive power, power factor and the variables required for synchronization.Automatic Synchronizing. An automatic synchronizer is provided with thecontrol system to automatically synchronize the unit to the bus through pushbutton control on the digital control panel [DCP] or by receipt of an appropriate remote signal. A synch check relay is provided as an additional permissive and for backup protection.Motorized Voltage Adjust. Raise/lower voltage push button control is providedon the digital control panel to control a motorized potentiometer for voltagecontrol. An additional raise/lower switch, supplied by others, may be used tocontrol voltage from a remote location.KW Controller. A kW controller is provided to control the real load (kW) on thegenerator set while operating in parallel with a utility or other large source. The kW controller monitors the load carried by the generator set and adjusts the turbine's fuel flow to maintain a constant load as plant load changes. Protection against excessive kW load while in parallel with a large source is provided by the control system "T5" temperature limiter. The kW control system provides additional operational flexibility by allowing unit kW load level to be set at any desired level within the capacity of the unit. The kilowatt load level select switch and level adjustment is located on the digital control panel.KVAR/Power Factor Controller. A kVAR/power factor controller is providedto maintain a constant reactive load (kVAR) output or constant power factor (pf) on the generator set while the unit is operating in parallel with a utility or other large source. The controller applies a signal directly to the voltage regulator adjust circuit to maintain a constant reactive load or power factor with changes in the infinite bus voltage level. The system incorporates a set point adjust rheostat to set the desired kVAR or pf, a selector switch to choose kVAR or pf control mode, and a switch to turn the controller on and off.- Remote Control Capability (via Optional Supervisory Interface)An RS 232C/422 interface module is provided to give the user's supervisorycomputer access, such as SCADA, to the Turbotronic control system data.Limited control capability is provided to allow the supervisory computer to start and stop the unit, reset alarms, and raise/lower speed and load set points. The communications protocol is Allen Bradley's DF1. The interface module may be located up to 10,000 feet (3,048 meters) from the turbine control system and located up to 50 feet (15 meters) from the supervisory computer for the RS 232C module or 4,000 feet (1,219 meters) for the RS 422 module. The modules are "table top" units and require 120 Vac, 50/60 Hz power.- Turbine Compressor Cleaning:Piping Manifold for On-Crank cleaning- Weatherproof Acoustic Enclosure: Noise Level 76 dba @ 50 ft.Ventilation Silencers and Fans, Lights, Fire Detection and Gas MonitoringSystem with Auto Shutdown and Fuel Supply Shutoff, High TemperatureDetection and AlarmCO2 Fire Suppression System for Generator Set Enclosure- Documentation:Interface Drawings, Operation and Maintenance Manuals, Test Reports- Inlet System:Barrier Filter and Silencer mounted on top of Generator Set enclosure- Exhaust Silencer and Outlet Extension Pipe (approximately 24 above ground)Tri-Axle Transport Trailer with Two Axle Pivoting BoosterTrailer Length 48 + 141 Booster (removable at site)Width 86, 90 across trailer axles133 Swing Clearance49 5th wheel Height (loaded)Air Ride Suspension and Air Raise and Lower KitSteel Disc Wheels with 275/70R x 22.5 TiresThree Tail Light PackageLanding Gear6 Additional Landing Legs with Soil Bearing Plates for Leveling and Stabilizationat SiteOverall transport height: 142Estimated Transport Weight: 118,000 lbs.Power Control Module:- Power Control Room (PCR)PCR HVAC systemGenerator Main Circuit Breaker, Single interface point to power gridTransformer Feeder Circuit BreakerBus PTs, Feeder CTs, Metering CTs and PTs, and Beckwith M-3425 ProtectiveRelayModule with the following relays:Impedance (21)Reverse Power Protection (32)Loss of Field Protection (40)Negative Phase Sequence Protection (46)PT Blown Fuse Protection (60)Time Overcurrent Protection (50/51 V)Neutral Overcurrent Protection (51 N) utilized in grounded site designBus Ground Fault Detection (59N) utilized in ungrounded site designGenerator Differential Fault Protection (87 G)One High Speed Tripping Relay (86) for Circuit Breaker Trip, Lockout,and Turbine ShutdownSettings, Programming, and Factory Testing are includedLightning Arrestor and Surge CapacitorMotor Control Center, Serves Turbine Generator AC Auxiliary Loads120VDC Turbine Generator Battery System with ChargerDedicated 120VDC Switchgear Battery System with ChargerStart Motor Variable Frequency Drive (VFD)DC Backup Lube Oil Pump ContactorInterior LightingPhotocell Controlled Exterior Lighting at Access DoorsEmergency Eyewash Station- Ancillary EquipmentGas Turbine Lube Oil CoolerNeutral Ground ResistorAuxiliary Load Transformer (13.8 kv:480 v, 60 Hz)Eliminates site requirement to supply 480VAC shore power480VAC shore power connection point, (to be used when load side of generatorcircuitbreaker is not energized continuously with 13.8 kv)- Two Axle Transport Trailer for Power Control Room (PCR)Trailer Length 46 OverallWidth 8649 5th wheel Height (loaded)Air Ride Suspension and Air Raise and Lower KitSteel Disc Wheels with 255/70R x 22.5 TiresThree Tail Light PackageLanding Gear4 Additional Landing Legs with Soil Bearing Plates for Leveling and Stabilizationat SiteCapacity: 70,000 lbs. UniformOverall Transport Height: 140Estimated Transport Weight: 48,000 lbs.

Accessories IncludedControl System Remote Dial Up. Provides remote control and monitoring capability viatelephone connection. Includes Video Display (VDT) and modem.480VAC Shore Power Connection with transfer switch. This feature allows black start ofTaurus 60 with a diesel generator.Dual Fuel Configuration with Gas Only Injectors. Allows 25 ppmv NOX level on gasfuel.Includes fuel boost pump, primary fuel filter, and air assist compressor in a single moduleconfiguration. In order to operate in the dual fuel mode in the field would requireinstallation of dual fuel injectors. Dual fuel injectors are not included.SML RESOURCES INTERNATIONALFOR INQUIRIES CONTACTROY LEADER