solenoid control system test product bulletin 190 jan

2
Versa Products Company is excited to offer a valve option for the testing of a solenoid valve control circuits in applications where closing down or “shutting in” the system is not an option. Versa’s bypass valve allows the testing and replacement of a component within the circuit while not shutting down the main system. Versa’s solution is simple to apply, operate and accomplished in one valve. The, basic valve is a 3 position manual valve. Operation is as follows: Position 1. This position is the normal position or the regular operation mode. Position 2. This position places the control circuit in the test mode. In this position the bypass valve allows pressure to the circuit for testing while maintaining pressure on the actuator. With pressure to solenoid inlet and solenoid circuit outlet blocked/isolated this position allows complete testing of solenoid circuit while not shutting down the system. Position 3. This position places the control system in a replace mode. Should it be determined that a component in the control circuit needs to be repaired and or replaced this position allows total isolation from pressure while still holding system pressure to actuator. Based on Versa’s proven C-316 or V-316 series high flow valves. Actuation is available as a rotary switch or key operated. Optional position indication available. Description: ¼” Solenoid Bypass valve Function: Custom circuit, 3 position (see circuit above) Actuator: Manual, detented Pressure: 0 to 150 psi (0- 14 bar) Flow: 2.0 Cv in normal position Temperature: 5ºF (-15ºC) to 300ºF (149ºC) Ports: ¼” npt Media: Air, Inert Gas, Natural Gas & Hydraulic Materials; Body: 316 stainless steel Actuators: 316 stainless steel Seals: FKM Options: Position indicator: Suffix -9SE Low temp Buna: Suffix -44 Description: ½” Solenoid Bypass valve Function: Custom circuit, 3 position, (see circuit above) Actuator: Manual, detented Pressure: 0 to 200 psi (0- 14 bar) Flow: 5.5 Cv in normal position Temperature: 5ºF (-15ºC) to 300ºF (149ºC) Ports: ½” npt Media: Air, Inert Gas, Natural Gas & Hydraulic Materials; Body: 316 stainless steel Actuators: 316 stainless steel Seals: FKM Options: Position indicator: Suffix -9E Low temp Buna: Suffix -44 SOLENOID CONTROL SYSTEM TEST Stainless Steel Bypass Valve Product Bulletin 190 Jan. 2021 Typical Circuit Versa Products Company, Inc., 22 Spring Valley Rd., Paramus, NJ 07652 USA Phone: (201) 843-2400 FAX: (201) 843-2931 Versa BV, Prins Willem Alexanderlaan 1427, 7312 GB Apeldoorn, The Netherlands Phone: +31-55-368-1900 FAX: +31-55-368-1909 e-mail: [email protected] www.versa-valves.com Size Detent Key Actuator Rotary Actuator 1/4” Detent CAU-430X-316-314E507-2039 CAU-430X-316-357E-2039 Detent w plunger extension CAU-430X-316-314E507-9SE-2039 CAU-430X-316-357E-9SE-2039 1/2” Detent VAU-450X-316-314E507-2039 VAU-450X-316-357E-2039 Detent w plunger extension VAU-450X-316-314E507-9E-2039 VAU-450X-316-357E-9E-2039 Visit VersaSelect for the full selection VAU-450X-316-357E-9E-2039 To Actuator Supply Bypass Valve Solenoid Valve Positions 1 3 2 5 3 A2 B4

Upload: others

Post on 18-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Versa Products Company is excited to offer a valve option for the testing of a solenoid valve control circuits in applications where closing down or “shutting in” the system is not an option. Versa’s bypass valve allows the testing and replacement of a component within the circuit while not shutting down the main system. Versa’s solution is simple to apply, operate and accomplished in one valve. The, basic valve is a 3 position manual valve. Operation is as follows:

Position 1. This position is the normal position or the regular operation mode.

Position 2. This position places the control circuit in the test mode. In this position the bypass valve allows pressure to the circuit for testing while maintaining pressure on the actuator. With pressure to solenoid inlet and solenoid circuit outlet blocked/isolated this position allows complete testing of solenoid circuit while not shutting down the system.

Position 3. This position places the control system in a replace mode. Should it be determined that a component in the control circuit needs to be repaired and or replaced this position allows total isolation from pressure while still holding system pressure to actuator.

Based on Versa’s proven C-316 or V-316 series high flow valves. Actuation is available as a rotary switch or key operated. Optional position indication available.

Description: ¼” Solenoid Bypass valve

Function: Custom circuit, 3 position (see circuit above)Actuator: Manual, detentedPressure: 0 to 150 psi (0- 14 bar)

Flow: 2.0 Cv in normal positionTemperature: 5ºF (-15ºC) to 300ºF (149ºC)Ports: ¼” npt

Media: Air, Inert Gas, Natural Gas & Hydraulic

Materials; Body: 316 stainless steel Actuators: 316 stainless steel Seals: FKM

Options: Position indicator: Suffix -9SE Low temp Buna: Suffix -44

Description: ½” Solenoid Bypass valve

Function: Custom circuit, 3 position, (see circuit above)Actuator: Manual, detentedPressure: 0 to 200 psi (0- 14 bar)

Flow: 5.5 Cv in normal positionTemperature: 5ºF (-15ºC) to 300ºF (149ºC)Ports: ½” npt

Media: Air, Inert Gas, Natural Gas & Hydraulic

Materials; Body: 316 stainless steel Actuators: 316 stainless steel Seals: FKM

Options: Position indicator: Suffix -9E Low temp Buna: Suffix -44

SOLENOID CONTROL SYSTEM TESTStainless Steel Bypass Valve

Product Bulletin 190Jan. 2021

Typical Circuit

Versa Products Company, Inc., 22 Spring Valley Rd., Paramus, NJ 07652 USA Phone: (201) 843-2400 FAX: (201) 843-2931 Versa BV, Prins Willem Alexanderlaan 1427, 7312 GB Apeldoorn, The Netherlands Phone: +31-55-368-1900 FAX: +31-55-368-1909 e-mail: [email protected] www.versa-valves.com

Size Detent Key Actuator Rotary Actuator

1/4”Detent CAU-430X-316-314E507-2039 CAU-430X-316-357E-2039

Detent w plunger extension CAU-430X-316-314E507-9SE-2039 CAU-430X-316-357E-9SE-2039

1/2”Detent VAU-450X-316-314E507-2039 VAU-450X-316-357E-2039

Detent w plunger extension VAU-450X-316-314E507-9E-2039 VAU-450X-316-357E-9E-2039

Visit VersaSelect for the full selection

VAU-450X-316-357E-9E-2039

To Actuator Supply

Bypass Valve

SolenoidValve

Positions 13 25 3

A2B4

Dimensions

Versa Products Company, Inc., 22 Spring Valley Rd., Paramus, NJ 07652 USA Phone: (201) 843-2400 FAX: (201) 843-2931 Versa BV, Prins Willem Alexanderlaan 1427, 7312 GB Apeldoorn, The Netherlands Phone: +31-55-368-1900 FAX: +31-55-368-1909 e-mail: [email protected] www.versa-valves.com

Visit VersaSelect for the full selection

CAU-430X-316-314E***-9SE-2039

VAU-450X-316-314E***-9E-2039

CAU-430X-316-314E***-9SE-2039Shown with key actuation and optional position indicator.

ByPass Valve

VAU-450X-316-314E***-9E-2039Shown with key actuation and optional position indicator.

3.5690

1.6541.9

4.69119

0.246.2Ø

Ø (3 MOUNTING HOLES)0.174.4

27º

0.6516.5In Position 3

0.5514.0In Position 2

Position Indicator

0.4511.4In Position 1

Ø (3 MOUNTING HOLES)0.266.6

6.52166

3.6192

2.5063.5

27º

0.8020.5In Position 3

0.6316In Position 2

Position Indicator

0.4511.5In Position 1