solid applied technologies
DESCRIPTION
Solid Applied Technologies. Gauger 420. Gauger420 – Description. Compact, continuous, non-contact, loop-powered, ultrasonic level meter: Simple installation and configuration 4-20mA output, RS485, USB, optional HART For measurement of liquids and solids. NEW. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/1.jpg)
Solid Applied Technologies
Gauger420
![Page 2: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/2.jpg)
2
Compact, continuous, non-contact, loop-
powered, ultrasonic level meter:
Simple installation and configuration
4-20mA output, RS485, USB, optional HART
For measurement of liquids and solids
Gauger420 – Description
Visit www.solidAT.com for other products
![Page 3: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/3.jpg)
3
Long range of 8 meters (26’)
Dead zone of only 15 cm (6”)
Fast process tracking rate up to 10 meter/minute (32’/min)
Reporting volume in Liters or Gallons
Supporting Open Channel Flow: flumes, weirs and Manning flow
Two temperature sensors for higher accuracy
A model for range of 9.5 meter (31’) is available.
Application Highlights
![Page 4: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/4.jpg)
4
PVDF sensor, superior in the presence of aggressive materials
Sealing rate IP68 withstanding full immersion/
rain/dust/snow
Low operating temperature down to -30°C / -22°F
High operating temperature of +70°C / +160°F
Plastic PC/ABS+UV, blending roughness and rigidity
Power supply 12-33 VDC
The most rugged design
![Page 5: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/5.jpg)
5
Liquid targets, solids (grains) and Open Channel Flow (OCF)
Storage vessels, process tanks and outdoor piles
Wastewater, water desalination, water treatment plants
Petrochemical, chemical, food and agriculture industries
OEM models and kit parts are available to partners
Markets and partners
![Page 6: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/6.jpg)
6
Configuration options
Full level
Empty level
Value to display
Application
A four-step manual setup
Configuration by PC and Device
Cloning
4-20 manual setup
20mA setting
4mA setting
Error indication
4-20 value
Process dynamics
Near block distance
Temperature sensors
Far block distance
Advanced setup
No need for any custom
tools !
![Page 7: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/7.jpg)
7
Flexible settings
4-20 Indication error
• Low 3.6 mA
• High 22 mA
• Hold Last Value
• Jump to near Low / High
Display
• Level
• Distance
• Volume
• Flow
• % Level, Distance,
Volume, Flow
4-20 representation
• Level
• Distance
• Volume
• Flow
• Fixed current
HART
• Values
• Address
Unit System
• Metric
• US
Temperature Sensors
• Embedded
• External
• Average
Open channel Flow
• Rectangular weir
• Trapezoidal weir
• V-Notch / H-Flume
• Parshall Flume
• Palmer Bowlus
• Khafagi-Venturi
• Leopold-Lagco
• Manning flowMore options
•Gas Factor
• Expansion coefficient
• False echo scan
![Page 8: Solid Applied Technologies](https://reader035.vdocument.in/reader035/viewer/2022062314/56813a30550346895da21912/html5/thumbnails/8.jpg)
About Solid Applied TechnologiesLeading manufacturer of ultrasonic-level-meters and
remote monitoring solutions