![Page 1: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/1.jpg)
Features:1.Rotating end cap and standard cap available.2.Patented heat sink and optical diffuser.3.No ballast required, wide voltage and constant current design4.Retro-fit kits available for direct replacement of T8/T10 fluorescent fixtures.5.SMD and DIP available6.cover: Clear, Semi-transparent, Frosted.
TEL:(+86-755)27650321
www.tp-led.com
Specifications for LED T10 UL Lamps(Replace fluorescent tube light)
Model No. Watts Tube Length
ECO-Tube10-2FT
ECO-Tube10-3FT
ECO-Tube10-4FT
ECO-Tube10-5FT
ECO-Tube10-6FT
ECO-Tube10-8FT
LEDs
587± mm110W
12W
18W
22W
26W
36W
160pcs DIP
120pcs SMD
220pcs DIP
220pcs SMD
280pcs DIP
290pcs SMD
320pcs DIP
350pcs SMD
390pcs DIP
410pcs SMD
560pcs DIP
580pcs SMD
8 7± mm9 1
119 17± mm
149 17± mm
1 97 17 ± mm
2383 1± mm
Lumens
900
900
1300
1100
18001650
2100
1850
2600
2350
3400
2950
( cap to cap) Replace Bycover
Clear
Frosted
Clear
Frosted
Clear
Frosted
ClearFrosted
Clear
Frosted
Clear
Frosted
18W
30W
36W
58W
70W
90W
Warm White:3000-3500KNatural White:4000-4500KDaylight White:5800-6300KCool White:7000-7500K
Color Temperature Specification
Voltage:Power Factor:>0.9CRI:>75Lifespan:5yearsLighting Angle:DIP:60°/120°,SMD:120°
AC100-277V 50/60Hz
Rotatable cap Rotatable cap
T8 Fluorescent
standard cap
![Page 2: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/2.jpg)
Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery Hospitals Parking Schools ., , ,
Application:
Dimension(mm)
1. Operating temperature range between -20℃ ~ 45℃2. Suitable for use indoor environment. 3. Suitable for damp locations. 4. Be used only with fluorescent luminaries5. Not to be intended for use with emergency light fixtures or exit lights. 6. Not to be used in enclosed fixtures or insulated ceilings
!
Wiring according to one of the follow diagrams
Wiring Method 1-Two sides connecting Wiring Method 2-One side connecting
L
N
N
L
OPENL
N
TEL:(+86-755)27650321
www.tp-led.com
Application Notes:
![Page 3: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/3.jpg)
Instruction Menu
Retrofit:LED Tube Lamps
Model No. Watts Tube Length
ECO-Tube10-2FT
ECO-Tube10-3FT
ECO-Tube10-4FT
ECO-Tube10-5FT
ECO-Tube10-6FT
ECO-Tube10-8FT
LEDs
AC100-277V 50/60Hz 0.1A 587± mm110W
14W
18W
22W
26W
36W
Input
AC100-277V 50/60Hz 0.15A
AC100-277V 50/60Hz 0.2A
AC100-277V 50/60Hz 0.25A
AC100-277V 50/60Hz 0.3A
AC100-277V 50/60Hz 0.4A
DIP SMD
160
220
120
220
280 290
320 350
390 410
560 580
8 7± mm9 1
119 17± mm
149 17± mm
1 97 17 ± mm
2383 1± mm
( cap to cap )
Color: Warm White, Natural White, Daylight White, Cool White
Cover: Clear, Semi-transparent, Frosted
![Page 4: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/4.jpg)
Maximum distancebetween lamps pinsockets
105mm
SECTION 1 - General Information
Models were only evaluated for factory installation to end luminaire, or to end Retrofit Luminaire, intendedto replace a fluorescent lamp where it is necessary to modify the luminaire.
These LED Tube Lamps intended to retrofit maximum four lamps, surface mount, or Type IC recessed mount fluorescent luminaries that use straight tubular lamps.
-These lamps should be installed by a licensed electrician.-These lamps work on line voltage and require all ballasts to be remove before the bulb is to be installed in the luminaire.-These lamps are to be used in indoor dry or damp location only. Not suitable for wet location luminaire.-These lamps are not to be used with a light dimmer. The starters need to be bypassed. Always contact ground lead to luminaire where applicable.-Please contact your authorized dealer, distributor, or Topband if you have any questions not addressed in these instructions. Please see contact information in last page.
SECTION2- WARNING
WARNING: To reduce the risk of electrical shock, do not remove cover and caps
No user-serviceable parts inside. Refer servicing to qualified service personnel.
WARNINGRISK OF ELECTRICAL SHOCK
DO NOT OPEN
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE
PRODUCT AND THE HAZARDS INVOLVED.
FOR USE ONLY WITH FLUORESCENT LUMINAIRES IDENTIFIED IN MANUFACTURER'S INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK,DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE
LUMINAIRE CONVERSION, RETROFIT
Kit components: 1-LED Tube, 1-Label and 1-Set of Instructions
2
These lamps can be used in any standard T8 lamp luminaire, allowing for it’s minimum spacing requirements
![Page 5: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/5.jpg)
WARNING-Risk of fire or electric shock. Retrofit kit installation requires knowledge of fluorescent lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
3
WARNING-Risk of fire or electric shock. The electrical rating of this product is AC100V-277V , the installer must determine whether they have AC100V-277V at the luminaire before installation.WARNING-Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs drawings.
WARNING-Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when drilling for installation of retrofit kit hardware. Check for enclosed wiring andcomponents.
WARNING-To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING-THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERETHE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION.
![Page 6: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/6.jpg)
4
WARNING-Risk of fire or shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders.
Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words "Instant Start" or "I.S." marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS.
“IMPORTANT SAFETY INSTRUCTIONS”
“Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.”“Not for use with dimmers.”
“The end retrofit luminaire has been modified and can no longer operate theoriginally intended lamp.”
“Caution-Risk of Electric Shock-Use in Dry and Damp Locations Only.”“Risk of Electric shock-Do Not Use WhereDirectly Exposed To Water.”“This device is not intended for use with emergency exit fixtures or emergencyexit lights.”
![Page 7: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/7.jpg)
SECTION3-Installation Instruction
Switch off power supply BEFORE COMMENCING WORK1
Luminaire
StartBallast
“DANGER–RISK OF SHOCK –DISCONNECT POWER BEFORE INSTALLATION”
2 Luminaire Retrofit Steps
1) Principle of wire circle
TP-Tube10
NL
Input Voltage: AC100-277V 50/60Hz
AC In
pu
t
2) Retrofit Steps
1)
2) Use the electric rubberized fabric or pressing wire cap to enlace well all the power supply cord parts which were cut off, especially the end sides of power supply cord.3) Install LED tube Lighting.4) Switch on power.
Choose wires connect method from A, B, C, D options according to the ballast and lumunaire type.
Switch off power supply BEFORE COMMENCING WORK
5
![Page 8: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/8.jpg)
6
A. Luminaire with electronical ballast
Retrofit There are two methods for wiring,Wirng method 1 and Wirng method 2.
Remove diffuser (if applicable)and fluorescent lamp
Cut off all wires which connected to ballast.
Fluorescent Tube Light
Fluorescent Tube Light
Connect two wires to branch circuit L and N according to the figure above.
LED Tube Light
OR
Wirng method 1
Installing the LED tube into the fixtures directionless.
Wirng method 2Connecting the side with
"AC Input" label into the holder with "L"& "N" wires.The tube will not be damaged if installed in reverse
![Page 9: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/9.jpg)
B. magnetic ballast
Retrofit Luminaire with There are two methods for wiring,Wirng method 1 and Wirng method 2.
Fluorescent Tube Light
N
L
ballast
S
6
NL
LED Tube Light
Connect two wires to branch circuit L and N according to the figure above.
Fluorescent Tube Light
N
L
ballast
S
Remove diffuser (if applicable)and fluorescent lamp
Cut off all wires which connected to ballast.
N
L
ballast
S
LED Tube Light
1.Must betake out of starter2.Equip with manufacturer's specified “ short circuit connector”
Take out starter
OR
C. ballastRetrofit Luminaire with two lamps and one There are two methods for wiring,Wirng method 1 and Wirng method 2.
Fluorescent Tube Light
Fluorescent Tube Light
Fluorescent Tube Light
Fluorescent Tube Light
Remove diffuser (if applicable)and fluorescent lamp
Cut off all wires which connected to ballast.
Connect two wires to branch circuit L and N according to the figure above.
OR
Wirng method 1
Installing the LED tube into the fixtures directionless.
Wirng method 2
"AC Input" label into the holder with "L"& "N" wires.The tube will not be damaged if installed in reverse
Connecting the side with
Wirng method 1
Installing the LED tube into the fixtures directionless.
Wirng method 2
"AC Input" label into the holder with "L"& "N" wires.The tube will not be damaged if installed in reverse
Connecting the side with
Sh
ort
cir
cu
it
co
nn
ecto
r
star ter
Or short c ircu it both end of bal last
Must be removed the starter first install the“short circuit connector”and LED Tube Light,then can work.
![Page 10: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/10.jpg)
7
2
Luminaire
Fluorescent tube
Fluorescent tube
Fluorescent tube
Fluorescent tube
D.Retrofit Luminaire with Four Lamps and one ballast There are two methods for wiring,Wirng method 1 and Wirng method 2.
Fluorescent tube
Fluorescent tube
Fluorescent tube
Fluorescent tube
Remove diffuser (if applicable)and fluorescent lamp
Cut off all wires which connected to ballast.
AC In
pu
t
AC Input
AC Input
AC Input
AC In
pu
tA
C In
pu
tA
C In
pu
t
AC Input
Connect two wires to branch circuit L and N according to the figure above.
OR
Wirng method 1
Installing the LED tube into the fixtures directionless.
Wirng method 2
"AC Input" label into the holder with "L"& "N" wires.The tube will not be damaged if installed in reverse
Connecting the side with
![Page 11: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/11.jpg)
Install LED tube and Earth (Ground)3
Luminaire
LED Tube
Ballast and Starter must be operated with the method as in step Luminaire Retrofit Steps”! 2“
4 Connect to power
Luminaire
8
![Page 12: Specifications for LED T10 UL Lamps - eco-smart.org · Restaurants & Hotels, Shopping mall, Retail & Grocey, Show room, Airport, Project Gallery, Hospitals, Parking, Schools . Application:](https://reader030.vdocument.in/reader030/viewer/2022021617/5b5d9b967f8b9ad21d8e94e7/html5/thumbnails/12.jpg)
PIN ROTATED 0~90 DEGREE
120° 120°
AFTER ROTATED
Lighting Angle Lighting Angle
PIN ROTATED 0~90 DEGREE5