Installation Guide 1 QDM-02-000180 Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved. Spring Conduit The Spring Conduit solution provides power and control to operable window unitscontaining View Dynamic Glass. With this solution, an IGU cable can securely traverse between a window frame and the window unit while accommodating various types of hinge movements. Examples of applications include casement, tilt and turn, awning and hopper-style windows. The Spring Conduit installs on the hinged side of the window installation. Spring Conduit Awning Installation Spring Conduit Casement Installation

Upload: others

Post on 23-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

Installation Guide

1

QDM-02-000180

Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit

The Spring Conduit solution provides power and control to operable window unitscontaining View Dynamic Glass. With this solution, an IGU cable can securely traverse between a window frame and the window unit while accommodating various types of hinge movements. Examples of applications include casement, tilt and turn, awning and hopper-style windows. The Spring Conduit installs on the hinged side of the window installation.

Spring ConduitAwning Installation

Spring ConduitCasement Installation

Page 2: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

2Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

B

A C

D

E

Parts Diagram

Item Qty Part Number Description

A 1 390-000074 Spring Conduit

B 8 500-101116Screw, Flat Head Phillips,

Self-Tapping, 6-32 X 1.000*

Installation Kit Parts

C 1 050-101221 Drill Bit, #52 (1/16”)

D 1 050-101500 Step Drill Bit, 3/16”-1/2”

E 1 050-101220 Transfer Punch, #29 (0.136”)

*Minimum of 2 screws per conduit base required.

Page 3: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

3Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

Dimensions

Initial Length 6 1/4” ± 1/8” (as shipped, between pilot holes)

Installed Lengh 6 1/4” ± 1/8” (between pilot holes)

Maximum Offset 3” (for parallel off set installations)

MINIMUMOFFSET

1" 25.4mm158.75mm ± 3.175mm

MAXIMUMOFFSET

9.525mmTYPICAL

TO IGU

TO WINDOWCONTROLLER

3/8"

3.175mmTYPICAL1/8"

6 1/4" ± 1/8"

19.05 mmTYPICAL3/4"

19.05 mmTYPICAL3/4"

12.7mmTYPICAL

1/2"

3" 76.2mm

Page 4: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

4Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

Specifications

Ordering Information

System Part Number Description

390-000074-01 Spring Conduit Assembly* – Clear Anodized

390-000074-02 Spring Conduit Assembly* – Black Anodized

Installation Kit Part Number Description

015-101376 See Installation Kit Parts List, Page 3

Initial Length 6 1/4 ± 1/8”

Installed Depth 3/8”

Window Offset Minimum gap space of 3/8” between window jamb and window frame

Warranty 5 year warranty

ElectricalThe Spring Conduit is a low voltage product and is only for use with View IGU cables and controllers manufactured by View Dynamic Glass.

This product has IP rated connectors to transfer power and communication to and from the IGU.

* Includes integrated IGU cable and mounting screws for metal window frames.

Page 5: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

5Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

Step 1: Determine Locations of Sash and Frame Cable Transfer Holes

1. Prior to glazing or installation of the frame, determine locations for mounting the Spring Conduit to thewindow sash and frame based on the window type:

2. For windows ≥ 18 1/4 incheshinged length, select alocation ≤ 12 inches from theinterior corner of the hingedsash stile or rail nearest theIGU Cable connection, andtransfer this measurementto the exterior sash surface.For windows < 18 1/4 incheshinged length, select alocation ≥ 6 1/4 inches fromthe interior corner of thehinged sash stile or railopposite the IGU Cableconnection, and transfer thislocation to the exterior sashsurface. Next, determine acenter point equal to 1/2 ofthe sash depth for drillingthe sash cable transfer holeto access the IGU cable.

3. Transfer the sash transferhole center point to thefacing surface of the hingedframe jamb, extend themeasurement 6 1/4 inches,and determine a centerpoint equal to 1/2 of thejamb depth for drillingtahe frame cable transferhole to access the WindowController drop cable.

• Casement window • Awning window • Hopper window• Tilt & Turn window

WINDOW 0FFSET (3/8" MIN.)

WINDOWCONTROLLERDROP CABLE

IGUCABLE

SPRINGCONDUIT

COIL

IGU

DRILL FRAME13mm1/2"

DRILL SASH

FACINGFRAMESURFACE

EXTERIORSASHSURFACE

SPRINGCONDUIT

FRAME-ENDBASE

SPRINGCONDUIT

SASH-ENDBASE

13mm1/2"

6 1/4"159mm

Page 6: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

6Rev v2 | Dec 2019 © 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

IGU Cable,Connector2" Extended

Rev v2 |

Step 2: Drill Cable Transfer Holes in Sash and Frame

Step 3: Mark Locations of Spring Conduit Sash and Frame Screw Mount Holes

Step 4: Drill Spring Conduit Sash and Frame Screw Mount Holes(Metal Sash/Frame Only)

Step 5: Mount IGU Sash to Frame and Complete Spring Conduit Installation

Drill 1/2" cable transfer holes in the the sash and frame using STEP DRILL BIT (D).

1. Insert Spring Conduit cable and sash-end base into the sash cable transfer hole, and positionthe unit parallel to the rail or stile as per the final assembly.

• Mark drilling center points for screw mount holes using TRANSFER PUNCH (E) and mallet.

• Remove Spring Conduit from sash.

2. Insert Spring Conduit cable and frame-end base into the frame cable transfer hole, andposition the unit parallel to the jamb as per the final assembly.

• Mark drilling center points for screw mount holes using TRANSFER PUNCH (E) and mallet.

• Remove Spring Conduit from frame.

Drill 1/16" screw mount holes in sash and frame using DRILL BIT (C).

1. Pass approximately 2" of the IGU cable and connectorthrough the sash cable transfer hole.

2. Complete assembly of the IGU sash.

3. Position sash relative to frame and secure hingeconnections.

4. Connect Spring Conduit sash-end cable to IGU cable.

5. Pass the connected cables through the cable transferhole, and insert Spring Conduit sash-end base intothe hole.

6. Secure Spring Conduit to sash using SCREWS (B).

Page 7: Spring Conduit - View, Inc · Spring Conduit Installation Guide 1. Open and close window to test operation and check for full range of motion. • Spring Conduit should not stretch

7Rev v2 | Dec 2019

view.com | 1-855-478-8468 | [email protected]

© 2019 View, Inc. All rights reserved.

Spring Conduit Installation Guide

1. Open and close window to test operation and check forfull range of motion.

• Spring Conduit should not stretch beyond the 3"maximum off set length in any position (see page 3).

2. Confirm minimum 3/8 inch window off set (see page 5).

• Spring Conduit should not fully compress or coil bindin any position.

• Spring Conduit coil should not contact sash or framein any position.

Step 6: Mount Spring Conduit to Frame

Step 7: Test Spring Conduit Installation

1. Pass approximately 2" of the Window Controller drop cable andconnector through the frame cable transfer hole.

2. Connect Spring Conduit frame-end cable to Window Controller dropcable.

3. Pass the connected cables through the cable transfer hole and insertSpring Conduit frame-end baseinto the hole.

4. Secure Spring Conduit to frame using SCREWS (B).

WindowController

Drop Cable,Connector

2" Extended