sq range submersible pumps - your water pump superstore€¦ · sq range submersible pumps motor...
TRANSCRIPT
SQ RANGE
SUBMERSIBLE PUMPSMOTOR PROTECTION AND WEAR-REDUCING BENEFITSAt only 3” in diameter, the Grundfos SQ submersible pump is extremely compact and ideal for small or restricted boreholes. In addition to the features and benefits shared with the renowned SP submersible pump, the SQ offers a number of motor protection and wear-reducing features that makes it the obvious choice for groundwater extraction at domestic or small waterworks, for irrigation systems, or for groundwater lowering.
0 4 8 12 16 20 24 28 32 36 Q [US GPM]30
40
60
80
100
150
200
300
400
600
800
[ft]H
0 2 4 6 8 Q [m³/h]
10
20
30
40
50
60
708090
100100
200
[m]H
SQ
ISO 9906
SQESQE-N
SQ-N
5 SQ
/SQ
E
10 S
Q/S
QE
15 S
Q/S
QE
22 S
Q/S
QE
30 S
Q/S
QE
LSQSL001_SQ Range Leaflet.indd 1 10/26/2016 9:21:06 AM
Grundfos2001 Butterfield Rd, Ste 1700 Downers Grove, IL 60515
The
nam
e G
rund
fos,
the
Gru
ndfo
s log
o, a
nd b
e th
ink
inno
vate
are
regi
ster
ed tr
adem
arks
ow
ned
by G
rund
fos H
oldi
ng A
/S o
r Gru
ndfo
s A/S
, Den
mar
k. A
ll rig
hts r
eser
ved
wor
ldw
ide.
L-SQ
-SL-
001
10-
16
www.grundfos.uswww.grundfos.cawww.grundfos.mx
HOW THE SQ PROTECTS AND REDUCES WEAR
VOLTAGE HANDLING
Increased winding temperature caused by undervoltage often results in reduced lifetime. The SQ motor is protected against over and undervoltage, and voltage fluctuation generally.
DRY RUNNING PROTECTION
The SQ pump is factory pre-set based on minimum power consumption, and dry-running protection is activated 40 seconds after power is connected to allow priming of the pump. When there is no water in the hydraulics, power consumption is reduced. The SQ stops automatically when below the dry run power limit and restarts automatically within 5 minutes after cut-out.
ADDED FEATURES THAT PROTECT YOUR SQ PUMP
Compared with a conventional 4” pump and motor, the added features of voltage handling and soft start, power supply, and dry running protection offer simplicity and reliability for your installation.
TECHNICAL DATA
• Flow up to 36 gpm (8.2 m3/h)• Head up to 780 ft (180 m)• Nominal power supply: 1x200-240 V – 50/60 Hz• Max. acceptable media temp: 86°F (40°C) when flow past motor• Pump diameter: 2.9 in. (74 mm) Min. well diameter: 3 in. (76 mm)• Weight (min./max.): 10.4-14.1 lbs (4.7-6.4 kg)• Thread connections: RP 1¼˝ / RP 1½˝• Materials (Stainless steel): DIN W.-Nr. 1.4301/1.4401, AISI 304/316• The SQ pump can be installed vertically or horizontally• Built-in electronics• Permanent magnet motors • Torgue exceeds that of traditional motors• Higher efficiency than traditional motors
SOFT START
Soft start ensures a low starting current with a smooth and steady acceleration. This offers excellent starting reliability at low voltage, prevents overload of the mains power, reduces water hammer in the pipe, and reduces pump wear. Low current draw and soft start allows use of smaller gauge wire compared to traditional 4” motors. This can reduce the overall cost of installation.
POWER SUPPLY
Low ampere usage makes it possible to connect more appliances to the same fuse group or reduce the size of the power line. Small generators can be used with SQ.
Grundfos recommends to use a generator with a capacity 50% higher than rated pump power consumption.
The SQ pump provides several features that simplify your installation and add reliability to the system.
150 180 200
207 V 244 V
Conventional AC Motor
SQ SQ
220 240 260 280 315
Supply voltage [V]
Current
Time
Soft start
Direct online (DOL)
2 sec.
Properties & features SQ Conventional
AC motor
Overvoltage/undervoltage protection Yes No
Integrated dry running protection Yes No
Over temperature protection Yes No
Overload protection Yes No
Start function with high torque and without starter box Yes No
H
Q
Q
PP1P cut-out
H
Q
Q
PP1P cut-out