ss3000e dual channel h2o gas analyzer

14
SpectraSensors, Inc. 4333 W Sam Houston Pkwy N Ste 100 Houston, TX 77043 Tel: 800 619 2861 Fax: 713 466 3172 spectrasensors.com KEY FEATURES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Accurate, real-time measurements No wet-up or dry-down delays RELIABLE in harsh environments Short term payback; no consumables NIST-traceable calibration Analog and digital Outputs for remote monitoring NEW FEATURES Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating Optional RS485 and Ethernet Communications AMS100 Analyzer Management Software SS3000e DUAL CHANNEL H 2 O GAS ANALYZER FOR NATURAL GAS SpectraSensors SS3000e Dual Channel Gas Analyzer is capable of measuring moisture in this dual channel system which enhances cost savings by incorporating two sensors in one. RAPID RESPONSE TIME The SS3000e analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors. TRUSTWORTHY MEASUREMENTS Dependable data is an essential element in the quest for improved safety and quality. The SS3000e analyzer delivers precise, reliable measurements using patented Tunable Diode Laser (TDL) technology developed by NASA. The TDL sensor never comes into contact with the sample gas stream. The result is a sensor which does not suffer from contamination or drift due to vapor impurities such as glycol, methanol or amines. The SS3000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data. STATE OF THE ART TECHNOLOGY The analyzer works by shining a laser beam through the sample cell. The laser beam is selected to interact only with the measured compound, creating an absorption signal. The higher the concentration of H 2 O, the greater absorption of light and the stronger the corresponding absorption signal. Spectrum Software analyzes these absorption peaks to produce very accurate and repeatable measurements. Since the calculation is a direct, fundamental measurement, the amount of H 2 O present can be measured in real- time. LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance. Product Code 10805

Upload: others

Post on 01-Oct-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

Virtually maintenance free

No interference from glycol, methanol or amine contaminants (vapor phase)

Accurate, real-time measurements

No wet-up or dry-down delays

RELIABLE in harsh environments

Short term payback; no consumables

NIST-traceable calibration

Analog and digital Outputs for remote monitoring

NEW FEATURES

Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating

Optional RS485 and Ethernet Communications

AMS100 Analyzer Management Software

SS3000e DUAL CHANNEL H2O GAS ANALYZERFOR NATURAL GAS

SpectraSensors SS3000e Dual Channel

Gas Analyzer is capable of measuring

moisture in this dual channel system

which enhances cost savings by

incorporating two sensors in one.

RAPID RESPONSE TIME The SS3000e analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

TRUSTWORTHY MEASUREMENTS Dependable data is an essential element in the quest for improved safety and quality. The SS3000e analyzer delivers precise, reliable measurements using patented Tunable Diode Laser (TDL) technology developed by NASA.

The TDL sensor never comes into contact with the sample gas stream. The result is a sensor which does not suff er from contamination or drift due to vapor impurities such as glycol, methanol or amines.

The SS3000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.

STATE OF THE ART TECHNOLOGY The analyzer works by shining a laser beam through the sample cell. The laser beam is selected to interact only with the measured compound, creating an absorption signal. The higher the concentration of H2O, the greater absorption of light and the stronger the corresponding absorption signal. Spectrum Software analyzes these absorption peaks to produce very accurate and repeatable measurements. Since the calculation is a direct, fundamental measurement, the amount of H2O present can be measured in real-time.

LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

Product Code 10805

Page 2: SS3000e DUAL CHANNEL H2O GAS ANALYZER

www.spectrasensors.comAN 10089 10805e EN 02

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Direct: +1 713 370-2700 Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nm

ISO 9000:2000No. A16877

SPECIFICATIONS

Application DataTarget Components Dual H2O in Natural GasTypical Measurement Ranges 0-422ppmv (0-20 lb/MMscf )

Ranges up to 10,000ppmv available*Typical Precision ±4ppmvMeasurement Response Time 0.25-2 seconds

(Total system response dependent on fl ow rate and sample system volume)Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental/Sample Temperature Range -20º to 50º C (-4º to 122º F)

-10º to 60º C (14º to 140º F) optionalSample Pressure Maximum cell pressure 70kPaG (10 psig)

Pressure inlet to Sample System 140-340kPaG (20-50psig)Sample Flow Rate 0.5-1 L/min (1-2 scfh)Recommended Validation H2O - Bureau of Mines Chilled Mirror or Portable TDL

Electrical DataInput Voltage 100-240 VAC, 50-60 HZ

18-24 VDC optional Max Current (unheated) 1 amp maximum @ 120 VAC , 1.6A @ 24VDCMax Current (heated) 2 amps maximum @ 120 VAC Communication Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load

Serial: RS232C standard, RS485 and Ethernet OptionalProtocol: Modbus Gould RTU or Daniel RTU or ASCII

Digital Outputs 2, General Fault and Concentration/Assignable Alarm LCD Display Concentration, Cell Pressure, Temperature, Alarms & Diagnostics

PhysicalEnclosure Type NEMA 4X Stainless Steel EnclosuresDimensions H,L,W 973, 406, 224mm (38.3, 16, 8.8 inches)Approximate Weight 45kg (100lbs) Sample Cell Dimensions 438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 2

Certifi cation CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters)

Directives EN61010-1 & EN61326-1

* Consult factory for alternative or extended ranges.

SS3000e Dual Moisture Analyzer

Page 3: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

Virtually maintenance free

No interference from glycol, methanol or amine contaminants (vapor phase)

Accurate, real-time measurements

No wet-up or dry-down delays

RELIABLE in harsh environments

Short term payback; no consumables

NIST-traceable calibration

Analog and digital Outputs for remote monitoring

NEW FEATURES

Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating

Optional RS485 and Ethernet Communications

AMS100 Analyzer Management Software

SS3000e DUAL CHANNEL H2O/CO2 GAS ANALYZERFOR NATURAL GAS

SpectraSensors SS3000e Dual Channel

Gas Analyzer is capable of measuring

moisture and carbon dioxide in this cost

eff ective dual channel system which

enhances cost savings by incorporating

two sensors in one.

RAPID RESPONSE TIME The SS3000e analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

TRUSTWORTHY MEASUREMENTS Dependable data is an essential element in the quest for improved safety and quality. The SS3000e analyzer delivers precise, reliable measurements using patented Tunable Diode Laser (TDL) technology developed by NASA.

The TDL sensor never comes into contact with the sample gas stream. The result is a sensor which does not suff er from contamination or drift due to vapor impurities such as glycol, methanol or amines.

The SS3000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.

STATE OF THE ART TECHNOLOGY The analyzer works by shining a laser beam through the sample cell. The laser beam is selected to interact only with the measured compound, creating an absorption signal. The higher the concentration of H2O/CO2, the greater absorption of light and the stronger the corresponding absorption signal. Spectrum Software analyzes these absorption peaks to produce very accurate and repeatable measurements. Since the calculation is a direct, fundamental measurement, the amount of H2O/CO2 present can be measured in real-time.

LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

Product Code 10704

Page 4: SS3000e DUAL CHANNEL H2O GAS ANALYZER

www.spectrasensors.comAN 10090 10704 EN 02

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Direct: +1 713 370-2700 Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nm

ISO 9000:2000No. A16877

SPECIFICATIONS

Application DataTarget Components H2O / CO2 in Natural GasTypical Measurement Ranges - H2O 0-422ppmv (0-20 lb/MMscf )

Ranges up to 10,000ppmv available*Typical Precision - H2O ±4ppmvTypical Measurement Ranges - CO2 0-5% and 0-10% Typical Precision - CO2 ±1% of reading or ±0.04ppmv (400ppmv), whichever is greaterMeasurement Response Time 0.25-2 seconds (Total system response dependent on fl ow rate and sample

system volume)Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental/Sample Temperature Range -20º to 50º C (-4º to 122º F) -10º to 60º C (14º to 140º F) optionalSample Pressure Maximum cell pressure 70kPaG (10 psig)

Pressure inlet to Sample System 140-340kPaG (20-50psig)Sample Flow Rate 0.5-1 L/min (1-2 scfh)Recommended Validation H2O - Bureau of Mines Chilled Mirror or Portable TDL

CO2 - Binary Cal Gas Bottle with Methane Background

Electrical DataInput Voltage 100-240 VAC, 50-60 HZ

18-24 VDC optional Max Current (unheated) 1 amp maximum @ 120 VAC , 1.6A @ 24VDCMax Current (heated) 2 amps maximum @ 120 VAC Communication Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load

Serial: RS232C standard, RS485 and Ethernet OptionalProtocol: Modbus Gould RTU or Daniel RTU or ASCII

Digital Outputs 2, General Fault and Concentration/Assignable Alarm LCD Display Concentration, Cell Pressure, Temperature, Alarms & Diagnostics

PhysicalEnclosure Type NEMA 4X Stainless Steel EnclosuresDimensions H,L,W 973, 406, 224mm (38.3, 16, 8.8 inches)Approximate Weight 45kg (100lbs) Sample Cell Dimensions 438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 2

Certifi cation CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters)

Directives EN61010-1 & EN61326-1

* Consult factory for alternative or extended ranges.

SS3000e Dual Channel Moisture & Carbon Dioxide Analyzer

Page 5: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

Virtually maintenance free

No interference from glycol, methanol or amine contaminants (vapor phase)

Accurate, real-time measurements

No wet-up or dry-down delays

RELIABLE in harsh environments

Short term payback; no consumables

NIST-traceable calibration

NEMA 4X enclosure

CSA Certifi ed

Analog and digital Outputs for remote monitoring

NEW FEATURES

Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating

Optional RS485 and Ethernet Communications

AMS100 Analyzer Management Software

SS2000e SINGLE CHANNEL H2O GAS ANALYZERFOR NATURAL GAS

SpectraSensors SS2000e Single

Channel Analyzer for H2O is extremely

reliable and tailored for the needs of

the natural gas industry. The sensor

measures gas using a patented Tunable

Diode Laser Diode (TDL) to determine

the concentration of the gas without

coming into physical contact with the

stream.

RAPID RESPONSE TIME The SS2000e analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

RELIABLE Trustworthy measurements are vital to natural gas pipeline and processing companies. Independent studies have proven that the SS2000e results are highly correlated with those of chilled mirrors. However,

chilled mirrors require skilled experts to operate and the results are highly scattered (large standard deviation).

Uncertain measurements can be extremely costly. Additional processing of dehydration costs, upset conditions, shut-ins and inconsistent process results may be caused by sensors that do not perform properly. The SS2000e is the fi rst to off er truly reliable measurement and simple operation.

LONG LIFE The TDL sensor does not come into contact with the sample gas stream. The result is a sensor which does not suff er from contamination or drift due to vapor impurities such as glycol, methanol or amines.

LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

The SS2000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.

Product Code 10201

Page 6: SS3000e DUAL CHANNEL H2O GAS ANALYZER

www.spectrasensors.comAN 10094 10201 EN 02

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Direct: +1 713 370-2700 Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nm

ISO 9000:2000No. A16877

SPECIFICATIONS

Application DataTarget Components H2O in Natural GasTypical Measurement Ranges 0-422ppmv (0-20 lb/MMscf )

Ranges up to 10,000ppmv available*Typical Precision ±4ppmMeasurement Response Time 0.25-2 seconds (Total system response is dependent

on fl ow rate and sample system volume)Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental/Sample Temperature Range -20º to 50º C (-4º to 122º F)

-10º to 60º C (14º to 140º F) optionalSample Pressure Maximum cell pressure 70kPaG (10 psig)

Inlet Pressure to Sample System 140-340kPaG (20-50psig)Sample Flow Rate 0.5-1 L/min (1-2 scfh)

Recommended Validation Bureau of Mines Chilled Mirror or Portable TDL

Electrical DataInput Voltage 100-240 VAC, 50-60 HZ

18-24 VDC optional Max Current (unheated) 1 amp maximum @ 120 VAC , 1.6A @ 24VDCMax Current (heated) 2 amps maximum @ 120 VACCommunication Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load

Serial: RS232C standard, RS485 and Ethernet OptionalProtocol: Modbus Gould RTU or Daniel RTU or ASCII

Digital Outputs 2, General Fault and Concentration/Assignable AlarmLCD Display Concentration, Cell Pressure, Temperature Alarms & Diagnostics

PhysicalEnclosure Type NEMA 4X Stainless Steel EnclosuresDimensions H,L,W 973, 406, 224mm (38.3, 16, 8.8 inches)Approximate Weight 34kg (75lbs)Sample Cell Dimensions 438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 1

Certifi cation CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters)

Directives EN61010-1 & EN61326-1

* Consult factory for alternative or extended ranges.

SS2000e Single Channel Moisture Analyzer

Page 7: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

Virtually maintenance free

No interference from glycol, methanol or amine contaminants (vapor phase)

Accurate, real-time measurements

No wet-up or dry-down delays

RELIABLE in harsh environments

Short term payback; no consumables

NIST-traceable calibration

NEMA 4X enclosure

CSA Certifi ed

Analog and digital Outputs for remote monitoring

NEW FEATURES

Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating

Optional RS485 and Ethernet Communications

AMS100 Analyzer Management Software

SS2000e SINGLE CHANNEL CO2 GAS ANALYZERFOR NATURAL GAS

SpectraSensors SS2000e Single

Channel Analyzer for CO2 is extremely

reliable and tailored for the needs of

the natural gas industry. The sensor

measures gas using a patented Tunable

Diode Laser Diode (TDL) to determine

the concentration of the gas without

coming into physical contact with the

stream.

RAPID RESPONSE TIME The SS2000e analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

RELIABLE Trustworthy measurements are vital to natural gas pipeline and processing companies. Independent studies have proven that the SS2000e results are highly correlated with those of chilled mirrors. However,

chilled mirrors require skilled experts to operate and the results are highly scattered (large standard deviation).

Uncertain measurements can be extremely costly. Additional processing of dehydration costs, upset conditions, shut-ins and inconsistent process results may be caused by sensors that do not perform properly. The SS2000e is the fi rst to off er truly reliable measurement and simple operation.

LONG LIFE The TDL sensor does not come into contact with the sample gas stream. The result is a sensor which does not suff er from contamination or drift due to vapor impurities such as glycol, methanol or amines.

LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

The SS2000e dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.

Product Code 10303

Page 8: SS3000e DUAL CHANNEL H2O GAS ANALYZER

www.spectrasensors.comAN 10095 10303 EN 02

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Direct: +1 713 370-2700 Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nm

ISO 9000:2000No. A16877

SPECIFICATIONS

Application DataTarget Components CO2 in Natural GasTypical Measurement Ranges 0-5% and 0-10%*Typical Precision ±1% of reading or ±400ppmv, whichever is greaterMeasurement Response Time 0.25-2 seconds (Total system response is dependent

on fl ow rate and sample system volume)Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental/Sample Temperature Range -20º to 50º C (-4º to 122º F)

-10º to 60º C (14º to 140º F) optionalSample Pressure Maximum cell pressure 70kPaG (10 psig)

Inlet Pressure to Sample System 140-340kPaG (20-50psig)Sample Flow Rate 0.5-1 L/min (1-2 scfh)

Recommended Validation Binary Cal Gas Bottle with Methane Backround

Electrical DataInput Voltage 100-240 VAC, 50-60 HZ

18-24 VDC optionalMax Current (unheated) 1 amp maximum @ 120 VAC , 1.6A @ 24VDCMax Current (heated) 2 ampS maximum @ 120 VAC Communication Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load

Serial: RS232C standard, RS485 and Ethernet OptionalProtocol: Modbus Gould RTU or Daniel RTU or ASCII

Digital Outputs 2, General Fault and Concentration/Assignable AlarmLCD Display Concentration, Cell Pressure, Temperature, Alarms & Diagnostics

PhysicalEnclosure Type NEMA 4X Stainless Steel EnclosuresDimensions H,L,W 973, 406, 224mm (38.3, 16, 8.8 inches)Approximate Weight 34kg (75lbs)Sample Cell Dimensions 438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 1

Certifi cation CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters)

Directives EN61010-1 & EN61326-1

* Consult factory for alternative or extended ranges.

SS2000e Single Channel Carbon Dioxide Analyzer

Page 9: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

Virtually maintenance free

No interference from glycol, methanol or amine contaminants (vapor phase)

Accurate real-time measurements

No wet-up or dry-down delays

Reliable in harsh environments

Short term payback; no consumables

NIST-traceable calibration

Analog and digital outputs for remote monitoring

NEW FEATURES

Heated and Unheated Stainless Steel Sample Conditioning Enclosures with NEMA-4X System Rating

Optional RS485 and Ethernet Communications

AMS100 Analyzer Management Software

SS500e SINGLE CHANNEL H2O GAS ANALYZERFOR NATURAL GAS

SpectraSensors SS500e Analyzer is an economical analyzer which utilizes the same state-of-the-art technology as SpectraSensors higher detection analyzers, assuring the user of high reliability and repeatability.

RAPID RESPONSE TIME At four measurements per second, the analyzer can measure the fastest changes in the pipeline. Adjustable, real-time results display every 0.25-2 seconds.

NO CONSUMABLES Because the analyzer’s sensor never touches the gas stream it does not get contaminated. The factory set calibration lasts for the life of the analyzer and reconditioning is never required.

PAYBACK The SS500e very quickly pays for itself by doing away with expensive consumables, extra sensor heads, labor and overhead associated with excessive maintenance. Costs due to unreliable gas measurements can be reduced by eliminating added

processing steps, poor gas quality and the possibility of damage to expensive equipment can result from sensors that produce incorrect data.

NO INTERFERENCE As with all SpectraSensors analyzers, the SS500e combines a patented laser with control electronics and “smart” software. The analyzer’s sensor heads are not subjected to corrosives or contaminants in the gas because the sensor is isolated from the sample gas stream.

The result is an analyzer which does not suff er from contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfi de, or mercaptans.

STATE OF THE ART TECHNOLOGY The analyzer works by shining a laser beam through the sample cell. The laser beam is selected to interact only with the measured compound, creating an absorption signal. The higher the concentration of H2O the greater absorption of light and the stronger the corresponding absorption signal. Spectrum Software analyzes these absorption peaks to produce very accurate and repeatable measurements. Since the calculation is a direct, fundamental measurement, the amount of H2O present can be measured in real-time.

Product Code 10101

A read out comparison of the SS500e (left curve)and a slower sensor demonstrates how eliminating

long dry-downs can drastically reduce costlyshutdown times. In this example, the alarm state is

erroneously extended for hours.

Page 10: SS3000e DUAL CHANNEL H2O GAS ANALYZER

www.spectrasensors.comAN 10096 10101e EN 02

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Direct: +1 713 370-2700 Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nm

ISO 9000:2000No. A16877

SPECIFICATIONS

Application DataTarget Components H2O in Natural GasTypical Measurement Ranges 40-422ppmv/40-2000ppmv (2-20 lb/MMscf )Typical Precision ±10ppmMeasurement Response Time 0.25-2 seconds (Total system response is dependent

on fl ow rate and sample system volume)Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental/Sample Temperature Range -20º to 50º C (-4º to 122º F)

-10º to 60º C (14º to 140º F) optionalSample Inlet Pressure Maximum cell pressure 70kPaG (10 psig)

Inlet Pressure to Sample System 140-340kPaG (20-50 psig)Sample Flow Rate 0.5-1 L/min (1-2 scfh)

Recommended Validation Bureau of Mines Chilled Mirror or Portable TDL

Electrical DataInput Voltage 100-240 VAC, 50-60 HZ

18-24 VDC optionalMax Current (unheated) 1 amp maximum @ 120 VAC , 1.6A @ 24VDCMax Current (heated) 2 amps maximum @ 120 VACCommunication Analog: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load

Serial: RS232C standard, RS485 and Ethernet OptionalProtocol: Modbus Gould RTU or Daniel RTU or ASCII

Digital Outputs 2, General Fault and Concentration/Assignable AlarmLCD Display Concentration, Cell Pressure, Temperature, Alarms & Diagnostics

PhysicalEnclosure Type NEMA 4X Stainless Steel EnclosuresDimensions H,L,W 973, 406, 224mm (38.3, 16, 8.8 inches)Approximate Weight 34kg (75lbs)Sample Cell Dimensions 438 mm H x 108 mm W (17 1/4”H x 4 1/4”W)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 1

Certifi cation CSA Class 1, Division 2, Groups BCD, Temp Code T3C (T3 with Heaters)

Directives EN61010-1 & EN61326-1

SS500e Moisture Analyzer

Page 11: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

One Technology, One Supplier

Complete Gas Quality Analyzer in One Small Package

Includes Sample Conditioning and Regulation

No Chemometrics

No Complex Fiber or Fiber Optics

Simple Installation and Operation

Fast and Continuous

Low Maintenance, No Light Source or Probe Replacements, No Tape and No Carrier Gas

No Field Calibration

Reliable in Harsh Environments

APPLICATIONS

Transportation Pipeline & Sales Gas

Raw Gas / Gathering

Underground Storage

Gas Processing, Dehydration & Sweetening

3-PACK H2S, H2O, CO2 ANALYZER SYSTEMFOR NATURAL GAS

The SpectraSensors H2S, H2O & CO2

3-Pack gas analyzer system retains

the analytical benefi ts and reliability

known by our existing customers. In

addition, reduced installation costs,

support and complexity are achieved

via a single technology for gas quality

measurements.

GAS QUALITY SIMPLIFIED The analyzer system includes all required sample conditioning and regulation. The sample system is heated to 50°C (122°F) to keep all constituents in vapor phase.

Training requirements are reduced and the system enables fewer electrical runs, fewer sample runs and less labor. Installation and operational costs are dramatically reduced.

The Installation diagram on the left is a simple representation of connection to the pipeline.

A variety of sample probe products are available to compliment the application.

SpectraSensors off ers probes, probe regulators, and heated regulators depending on the pressure in the pipeline, the gas and ambient temperatures and the hydrocarbon dew point.

Product Code 11715

3-Pack Analyzer System with Heated Sample Conditioning and Pressure Regulation

Page 12: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SPECIFICATIONS

Application DataTarget Components H2S, H2O, CO2 in Natural GasTypical Measurement Ranges - H2S 0-20 ±0.5 ppmv (other ranges available)Typical Measurement Ranges - H2O 0-20 ±0.2 lb/MMscf (other ranges available)Typical Measurement Ranges - CO2 0-10 ±0.04 % (other ranges available)Measurement Update Time H2S: 2 seconds

H2O & CO2: 1 secondTotal system response is dependant on fl ow rate and sample system volume

Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental Temperature Range -20º to 50º C (-4º to 122º F)

-15º to 60º C (5º to 140º F) optionalSample Inlet Pressure 1.5-4 barG (20-50 PSIG) to enclosure inletSample Cell Temperature Range -20º to 50º C (-4º to 122º F)

-15º to 60º C (5º to 140º F) optionalMaximum Cell Pressure 70kPag (10 PSIG)Sample Flow Rate H2S: 2-4 L/min (4 to 8 scfh)

H2O & CO2: 0.1-2 L/min (0.2 to 4 scfh)Recommended Validation H2O : Bureau of Mines Chilled Mirror

H2S & CO2: Binary Cal Gas Bottle with Methane Background

Electrical DataVoltage 100-240 VAC, 50-60 Hz standardMax Current 3A max @ 120 VAC , 1.5A max @ 240 VAC HzCommunications 4-20mA loop (concentration only), RS232 (all parameters)Digital Outputs 2, 1 General Fault and 1 Hi/Lo Concentration Alarm per measurement cellModbus Gould RTU, Daniel RTU or ASCIILCD Display Concentration, Cell Pressure and Temperature & Diagnostics

PhysicalEnclosure Type NEMA 4X - stainless steelDimensions 1450 mm H × 760 mm W × 330 mm D (57” H × 30” W × 13” D)Weight Approximately 154Kg (340lbs)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 3

Area Classifi cationCertifi cation CSA Class 1 Div 2 Groups ABCD, T3

SpectraSensors 3-Pack

Natural Gas Analyzer System

www.spectrasensors.comAN 10131 11715 EN 01

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nmISO 9000

Page 13: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SpectraSensors, Inc. • 4333 W Sam Houston Pkwy N Ste 100 • Houston, TX 77043 • Tel: 800 619 2861 • Fax: 713 466 3172 • spectrasensors.com

KEY FEATURES

One Technology, One Supplier

Complete Gas Quality Analyzer in One Small Package

Includes Sample Conditioning and Regulation

No Chemometrics

No Complex Fiber or Fiber Optics

Simple Installation and Operation

Fast and Continuous

Low Maintenance, No Light Source or Probe Replacements, No Tape and No Carrier Gas

No Field Calibration

Reliable in Harsh Environments

APPLICATIONS

Transportation Pipeline & Sales Gas

Raw Gas / Gathering

Underground Storage

Gas Processing, Dehydration & Sweetening

2-PACK H2S+H2O OR H2S+CO2 ANALYZER SYSTEMFOR NATURAL GAS

The SpectraSensors H2S + H2O

and H2S + CO2 2-Pack gas analyzer

systems retains the analytical

benefi ts and reliability known by

our existing customers. In addition,

reduced installation costs, support

and complexity are achieved via a

single technology for gas quality

measurements.

GAS QUALITY SIMPLIFIED The analyzer system includes all required sample conditioning and regulation. The sample system is heated to 50°C (122°F) to keep all constituents in vapor phase.

Training requirements are reduced and the system enables fewer electrical runs, fewer sample runs and less labor. Installation and operational costs are dramatically reduced.

The Installation diagram on the left is a simple representation of connection to the pipeline.

A variety of sample probe products are available to compliment the application.

SpectraSensors off ers probes, probe regulators, and heated regulators depending on the pressure in the pipeline, the gas and ambient temperatures and the hydrocarbon dew point.

Product Code 11006 and 11107

2-Pack Analyzer System with Heated Sample Conditioning and Pressure Regulation

Page 14: SS3000e DUAL CHANNEL H2O GAS ANALYZER

SPECIFICATIONS

Application DataTarget Components H2S + H2O and H2S + CO2 in Natural GasTypical Measurement Ranges - H2S 0-20 ±0.5 ppmv (other ranges available)Typical Measurement Ranges - H2O 0-20 ±0.2 lb/MMscf (other ranges available)Typical Measurement Ranges - CO2 0-10 ±0.04 % (other ranges available)Measurement Update Time H2S & CO2: 2 seconds

H2O: 1 secondTotal system response is dependant on fl ow rate and sample system volume

Principle of Measurement Tunable Diode Laser Absorption SpectroscopyEnvironmental Temperature Range -20º to 50º C (-4º to 122º F)

-15º to 60º C (5º to 140º F) optionalSample Inlet Pressure 1.5-4 barG (20-50 PSIG) to enclosure inletSample Cell Temperature Range -20º to 50º C (-4º to 122º F)

-15º to 60º C (5º to 140º F) optionalMaximum Cell Pressure 70kPag (10 PSIG)Sample Flow Rate H2S : 2-4 L/min (4 to 8 scfh)

H2O & CO2: 0.1-2 L/min (0.2 to 4 scfh)Recommended Validation H2S & CO2: Binary Cal Gas Bottle with Methane Background

H2O : Bureau of Mines Chilled Mirror

Electrical DataVoltage 100-240 VAC, 50-60 Hz standardMax Current 3A max @ 120 VAC , 1.5A max @ 240 VAC HzCommunications 4-20mA loop (concentration only), RS232 (all parameters)Digital Outputs 2, 1 General Fault and 1 Hi/Lo Concentration Alarm per measurement cellModbus Gould RTU, Daniel RTU or ASCIILCD Display Concentration, Cell Pressure and Temperature & Diagnostics

PhysicalEnclosure Type NEMA 4X - stainless steelDimensions 1450 mm H × 760 mm W × 330 mm D (57” H × 30” W × 13” D)Weight Approximately 154Kg (340lbs)Sample Cell Construction 316L Series Polished Stainless Steel StandardNumber of Sample Cells 2

Area Classifi cationCertifi cation CSA Class 1 Div 2 Groups ABCD, T3

SpectraSensors 2-Pack

Natural Gas Analyzer System

www.spectrasensors.comAN 10133 11006 EN 01AN 10133 11107 EN 01

4333 W Sam Houston Pkwy N, Ste 100Houston, TX 77043Tel: +1 800 619-1223Fax: +1 713 856-6623

LASER RADIATION–AVOID DIRECT EXPOSURE TO BEAM

CLASS IIIb LASER PRODUCT

10 mW MAX CW 800-3000 nmISO 9000