StainlessLiteUnvented mains pressure water storage in Duplex stainless steel

S U P P L I E R S T O T H E M E R C H A N T T R A D E F O R O V E R 4 0 Y E A R S

2

StainlessLite

Gledhill - The Cylinder SpecialistThe Gledhill name is synonymous with a family of water

heating and storage products that lead the field in terms

of innovation and quality. We are respected for our world-

leading range of primary stores, but we have also produced

unvented cylinders from the very beginning. Stainless Lite is

an unvented mains pressure store in Duplex stainless steel

that establishes new criteria for quality, performance and

life.

Providing powerful, mains-pressure performance, it

incorporates high flow rate controls, ideal for multi bathroom

homes where baths fill very quickly.

There are Indirect and Direct patterns for gas/oil and

electricity with model sizes from 60 litres to 400 litres in each

pattern with an additional eight options for solar energy.

Duplex Stainless SteelThe Stainless Lite uses the very latest high specification

Duplex to resist all forms of corrosion including crevice and

stress whilst its high mechanical strength gives it durability.

The very latest automated welding procedures along with

full post weld treatments guarantee welds that are as strong

as the parent metal. Stainless Lite is pressure tested in

the factory to a full 12 bar which is four times the normal

working pressure.

Corrugated CoilStainless Lite uses a high heat transfer corrugated tube heat

exchanger to give a 20% faster recovery than plain tube. It is

also lighter and stronger than plain tube making the vessel

the lightest and easiest to handle on site.

3

Heat LossAll Gledhill Stainless Lite cylinders are manufactured using

the very latest HCFC free EnviroFoam insulation. This has

an Ozone Depletion Potential (ODP) of zero and an industry

leading Global Warming Potential (GWP) of 0.7.

Tests show that the 50mm of EnviroFoam insulation

injected into the case and covering both domes achieves

astonishingly low levels of heat loss, which ensures it is fully

compliant with 2010 Part L requirements for both new build

and replacement cylinders.

25 Year GuaranteeThe 25 year guarantee underlines the usual Gledhill

confidence in its own products. We regularly have copper

cylinders returned to us that we made more than 40 years

ago – why should anyone expect less from stainless steel?

ServiceBuying a good reputable product is critical – but it must be

available when needed. Gledhill has strategically located

manufacturing units so that delivery can be made to a

merchant anywhere within hours.

Quality Standard - EN 12897All Stainless Lite cylinders are manufactured in accordance

with BS EN 12897 the specification for unvented water

Our complete range of stainless steel cylinder options are explained in this brochure:

Page 4 Stainless Lite Direct and Indirect

Page 6 Stainless Lite Solar

Page 8 Stainless Lite Slimline Direct, Indirect and Solar

Page 10 Stainless Lite Horizontal

Page 11 Stainless Lite Heat Pump

Page 12 Stainless Lite Heat Pump Solar

Page 14 Stainless Lite Slimline Heat Pump

Page 15 Buffer Store

Page 16 Flexible Buffer Store

Page 17 Stainless Lite Triple Coil

Page 18 Stainless Lite Vented

storage vessels. The cylinders have been tested by NSF-WRc

and WRAS, and found to comply with Building Regulations

G3 and Water Regulations.

In performance, it complies with the requirements of

BS EN 806-1 to 5 and meets the NHBC criteria for domestic

properties.

Gledhill also operates a quality management system audited

and accepted by the BSI in accordance with BS EN ISO

9001:2008.

The Stainless Lite cylinders are supplied with all the quality

fittings needed, according to model, including;

• Immersion heater(s) • 2 port zone valve (indirect)

• Wiring centre (indirect) • Dual thermostat (indirect)

• Inlet control set • Tundish

• Benchmark log book • Installation manual

• Expansion vessel kit including flexible connection hose

• Lift up pressure and temperature relief valve (unvented)

• Control thermostat and drain valve

• 90 degree elbow on hot draw off

4

Gledhill Building Products manufacture 16 standard direct

and indirect cylinders, ranging from 90 litres to 400 litres

capacity.

The Stainless Lite direct model is supplied with two

immersions for off-peak and on-peak use (except 90 litre

model which only has an on-peak immersion). Therefore,

the store of water in the cylinder can be heated utilising

the off-peak electricity, making the unit extremely efficient.

These cylinders are ultimately lightweight, easy to install

answer for electric hot water options.

The immersion heater(s) must be connected to the supply

through a double pole linked isolating switch with a

minimum breaking capacity of 13A.

All models have a temperature and pressure relief valve

factory set at 6 bar and 92-95°C.

The indirect range has a high efficiency corrugated tube

coil which is connected to a conventional boiler to heat

the cylinder of water. The coils corrugated design gives

you much faster re-heat times than can be achieved with

plain tube coils. All indirect models come with an on-peak

immersion but only the 250, 300 and 400 litre models are

supplied with an off-peak immersion.

All tappings are within a 90˚segment to make installation

easier.

Direct and IndirectUnvented cylinders for use with a conventional boiler or electric power

5

Stainless Lite Direct Technical Specification

Description D90 D120 D150 D180 D210 D250 D300 D400

Product Stock Code ASL0001 ASL0005 ASL0010 ASL0015 ASL0020 ASL0025 ASL0030 ASL0031

Energy Efficiency Class D D D D D D D D

Heat loss watts 35 44 51 54 65 75 85 118

Capacity litres 90 120 150 180 210 250 300 400

Height mm 745 930 1120 1305 1495 1745 1992 2030

Overall Diameter mm 550 550 550 550 550 550 550 630

Weight (empty) kg 13 18 22 24 28 32 37 48

Weight (full) kg 103 138 172 204 238 282 337 448

Pressure regulator bar 3 3 3 3 3 3 3 3

Expansion vessel size litres 12 12 18 18 24 24 35 2 x 24

kW rating of primary coil kW n/a n/a n/a n/a n/a n/a n/a n/a

Heat up time min 90 119 150 179 209 249 299 398/198

Stainless Lite Model Selection Guide

Maximum hot water demandMaximum number of bed

spaces (bedrooms)Model

1 shower room Bedsit (0) D120 IND90

1 bathroom 2 (2) D150 IND120

1 bathroom 4 (3) D180 IND120

1 bathroom & separate shower room 6 (4) D210 IND150

1 bathroom & 2 separate shower rooms or 2 bathrooms 7 (5) D210 IND180

2 bathrooms & separate shower room 7 (5) D250 IND210

2 bathrooms & 2 separate shower rooms 7 (5) D300 IND250

3 bathrooms & 2 separate shower rooms 9 (6) D400 IND300

3 bathrooms & 3 separate shower rooms 9 (6) - IND400

Stainless Lite Indirect Technical Specification

Description IND90 IND120 IND150 IND180 IND210 IND250 IND300 IND400

Product Stock Code ASL0035 ASL0040 ASL0045 ASL0050 ASL0055 ASL0060 ASL0065 ASL0066

Energy Efficiency Class B B B B C C C D

Heat Loss watts 35 44 51 54 65 75 85 118

Capacity litres 90 120 150 180 210 250 300 400

Height mm 745 930 1120 1305 1495 1745 1992 2030

Diameter mm 550 550 550 550 550 550 550 630

Weight (empty) kg 19 22 26 28 33 38 44 55

Weight (full) kg 109 142 176 208 243 288 344 455

Pressure regulator bar 3 3 3 3 3 3 3 3

Expansion vessel size litres 12 12 18 18 24 24 35 2 x 24

kW rating of primary coil kW 16.5 18.0 18.5 19.0 20.5 21.5 25.0 30.5

Heat up time min 17 21 25 30 32 36 38 41

Notes:

1 Heat up time from 15°C to 60°C (applies to primary source only)2 All connections are supplied with compression fittings for direct connection to copper pipework.3 The heat up times shown for the D400 model indicate the times when 1 or 2 immersions are fitted.4 The model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be made

with an Economy 10 tariff.5 When using the Direct model for high specification developments, an increase of one model size should be considered.6 For further ErP information, please refer to the installation manual at www.gledhill.net

6

StainlessLite SolarUnvented cylinders incorporating a solar coil

Model Selection Guide

Maximum hot water demandMaximum solarpanel area (m2)

Bedrooms Model

1 shower room 2.4 Bedsit SOL180d

1 bathroom 2.8 1-3 SOL210d

1 bathroom & separate shower room 3.36 1-3 SOL250d

1 bathroom & 2 separate shower rooms 4.0 2-4 SOL300d

2 bathrooms & separate shower room 6.0 4-5 SOL400d

Notes:

1 Heat up time from 15°C to 60°C (applies to primary source only)2 All connections are supplied with compression fittings for direct connection to copper pipework.3 The model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be made

with an Economy 10 tariff.4 When using the Direct model for high specification developments, an increase of one model size should be considered.5 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.6 Maximum solar panel area is calculated based on 25l/m2 of net solar panel area.

Gledhill has developed a range of cylinders specifically for solar

applications in mind, therefore providing an efficient way of

providing domestic hot water. Each model features a dedicated

high performance solar coil, transferring the maximum amount

of heat from the solar circuit to the stored water. The cylinders

are compatible with a wide range of solar systems available

through the United Kingdom and have been designed to

maximise the dedicated solar volume.

The direct models are electrically heated cylinders, using

the 3kW immersion heater supplied with the unit, with a

high performance solar coil. They are capable of meeting

the requirements of Building regulations, provided that it is

matched to the panels and the hot water requirement correctly.

The indirect cylinders are heated by a conventional boiler

(either gas or oil) through a second high performance coil.

The solar range is based on the standard Stainless Lite

cylinders, therefore still providing you with mains pressure

hot water, low standing heat losses and lightweight

construction. The range of cylinders is suitable for properties

from a bedsit to a 5 bedroom family home.

Stainless Lite Direct Solar Technical Specification

Description SOL180d SOL210d SOL250d SOL300d SOL400d

Product Stock Code ASL0070 ASL0075 ASL0080 ASL0085 ASL0086

Energy Efficiency Class B C C C D

Heat Loss watts 54 65 75 85 118

Capacity litres 180 210 250 300 400

Height mm 1305 1495 1745 1992 2030

Diameter mm 550 550 550 550 630

Weight (empty) kg 26 30 34 39 49

Weight (full) kg 206 240 284 339 449

Pressure regulator bar 3 3 3 3 3

Expansion vessel size litres 18 24 24 35 2 x 24

kW rating of primary coil kW n/a n/a n/a n/a n/a

Heat up time min n/a n/a n/a n/a n/a

Surface area of solar coil

m2 0.680 0.680 0.970 0.970 1.270

Dedicated solar volume litres 60 70 84 100 150

7

Model Selection Guide

Maximum hot water demandMaximum solarpanel area (m2)

Bedrooms Model

1 bathroom 2.8 1-3 SOL180i

1 bathroom & separate shower room 3.6 1-3 SOL210i

1 bathroom & 2 separate shower rooms 4.8 2-4 SOL250i

2 bathrooms & separate shower room 5.0 3-4 SOL300i

2 bathrooms & 2 separate shower rooms 6.6 4-5 SOL400i

Notes:

1 Heat up time from 15°C to 60°C (applies to primary source only)2 All connections are supplied with compression fittings for direct connection to copper pipework.3 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.4 Maximum solar panel area is calculated based on 25l/m2 of net solar panel area.

Stainless Lite Indirect Solar Technical Specification

Description SOL180i SOL210i SOL250i SOL300i SOL400i

Product Stock Code ASL0090 ASL0095 ASL0100 ASL0105 ASL0110

Energy Efficiency Class B C C C D

Heat Loss watts 54 65 75 85 118

Capacity litres 180 210 250 300 400

Height mm 1305 1495 1745 1992 2030

Diameter mm 550 550 550 550 630

Weight (empty) kg 30 35 40 46 59

Weight (full) kg 210 245 290 346 459

Pressure regulator bar 3 3 3 3 3

Expansion vessel size litres 18 24 24 35 2 x 24

kW rating of primary coil kW 18.0 18.5 19.0 20.5 22.0

Heat up time min 28 35 38 41 45

Surface area of solar coil

m2 0.680 0.680 0.970 0.970 1.270

Dedicated solar volume litres 96 101 107 125 165

8

StainlessLite SlimlineUnvented cylinders designed for restricted spaces with optional solar coil

The new Stainless Lite Slimline cylinders have been added

to our range of Duplex stainless steel cylinders, to enable

you to utilise those smaller storage areas.

The standard size Stainless Lite cylinders are 550mm

in diameter but the new slimline range has a reduced

diameter of 475mm.This now enables installers to fit the new

cylinders into smaller properties or older homes where there

are space limitations, and so provide the benefits of mains

pressure hot water.

The new range of Stainless Lite Slimline cylinders come in

sizes from 60 litres to 210 litres in both indirect and direct

versions. In addition, it also comes with a solar option in

180 litre and 210 litre sizes. This now means there will be a

model to suit most homes.

The introduction of the Slimline solar range enables

homeowners to not only upgrade to a Duplex stainless steel

cylinder, but also have the added benefit of being able to

utilise solar power to contribute to the heating of the store.

Properties that previously could not enjoy mains pressure

hot water can now enjoy powerful, mains-pressure

performance, incorporating high flow rate controls, ideal for

multi bathroom homes, where baths fill very quickly.

You will still benefit from the high heat transfer corrugated

tube giving 20% faster recovery than plain tubing, controlled

stratification and minimal heat loss.

All slimline models (except 60 and 90 litre direct options)

come complete with an on-peak immersion. All direct

models have an off-peak immersion.

75mm slimmer than a standard unit

9

Stainless Lite Indirect Slimline and Solar Technical Specification

Description IND60-SL IND90-SL IND120-SL IND150-SL IND180-SL IND210-SLSOL

180i-SLSOL

210i-SL

Product Stock CodeASL475IND60

ASL475IND90

ASL475IND120

ASL475IND150

ASL475IND180

ASL475IND210

ASL475IND180SOL

ASL475IND210SOL

Energy Efficiency Class B C C C C C C CHeat Loss watts 40 52 59 68 76 84 76 84Capacity litres 60 90 120 150 180 210 180 210Height mm 705 978 1250 1520 1790 1970 1790 1970Diameter mm 475 475 475 475 475 475 475 475Weight (empty) kg 14 19 23 28 31 34 33 37Weight (full) kg 74 109 143 178 211 244 213 247Pressure regulator bar 3 3 3 3 3 3 3 3Expansion vessel size litres 12 12 12 18 18 24 18 24kW rating of primary coil kW 15.0 16.5 18.0 18.5 19.0 20.5 18.0 18.5Heat up time min 13 17 21 25 30 32 28 35Surface area of solar coil

m2 n/a n/a n/a n/s n/a n/a 0.680 0.680

Dedicated solar volume litres n/a n/a n/a n/a n/a n/a 60 70

Stainless Lite Direct Slimline and Solar Technical Specification

Description D60-SL D90-SL D120-SL D150-SL D180-SL D210-SLSOL

180d-SLSOL

210d-SL

Product Stock CodeASL475

D60ASL475

D90ASL475

D120ASL475

D150ASL475

D180ASL475

D210ASL475

D180SOLASL475

D210SOL

Energy Efficiency Class D D D D D D C CHeat Loss watts 40 52 59 68 76 84 76 84Capacity litres 60 90 120 150 180 210 180 210Height mm 705 978 1250 1520 1790 1970 1790 1970Diameter mm 475 475 475 475 475 475 475 475Weight (empty) kg 13 16 22 30 31 32 32 36Weight (full) kg 73 106 142 180 211 242 212 246Pressure regulator bar 3 3 3 3 3 3 3 3Expansion vessel size litres 12 12 12 18 18 24 18 24kW rating of primary coil kW n/a n/a n/a n/a n/a n/a n/a n/aHeat up time min n/a n/a n/a n/a n/a n/a n/a n/aSurface area of solar coil

m2 n/a n/a n/a n/s n/a n/a 0.680 0.680

Dedicated solar volume litres n/a n/a n/a n/a n/a n/a 60 70

Model Selection Guide

Maximum hot water demandMaximum number of

bed spaces (bedrooms)Direct Model Indirect Model

1 shower room Bedsit (0) D120-SL / SOL180d-SL IND90-SL

1 bathroom 2 (2) D150-SL / SOL210d-SL IND120-SL / SOL180i-SL

1 bathroom 4 (3) D180-SL / SOL210d-SL IND120-SL / SOL180i-SL

1 bathroom & separate shower room 6 (4) D210-SL IND150-SL / SOL210i-SL

1 bathroom & 2 separate shower rooms or 2 bathrooms 7 (5) D210-SL IND180-SL

2 bathrooms & separate shower room 7 (5) - IND210-SL

Maximum solar panel area (m2) Direct Model Indirect Model

2.4 SOL180d-SL SOL180i-SL

2.8 SOL210d-SL SOL210i-SL

Notes:

1 Heat up time from 15°C to 60°C (applies to primary source only)2 All connections are supplied with compression fittings for direct connection to copper pipework.3 The Direct model sizes shown are based on a typical days hot water use assuming an Economy 7 tariff is provided. A reduction of one model size can normally be

made with an Economy 10 tariff.4 When using the Direct model for high specification developments, an increase of one model size should be considered.5 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.6 Maximum solar panel area is calculated based on 25l/m2 of net solar panel area.7 For further ErP information, please refer to the installation manual at www.gledhill.net

10

Horizontal OptionStainlessLite horizontal unvented cylinders with a solar option available

We have achieved yet another market first with the launch of

the UK’s only domestic horizontal unvented cylinder. This has

been independently approved by public health and safety

organisation, NSF-WRc, to meet the legal requirements of

Building Regulations

With another new addition to Gledhill’s market leading

family of StainlessLite cylinders, the new range of horizontal

products are available in sizes from 180 litres to 300 litres in

both indirect and indirect solar configurations.

Providing the ideal solution for locations where installation

height is restricted, Gledhill’s StainlessLite range is up to 50

per cent lighter than other unvented stainless steel cylinders,

making the product perfectly suited to loft spaces.

NSF

-WRC

APPROVED

P RO DUC

T

Notes:

1 Heat up time from 15°C to 60°C (applies to primary source only)2 All connections are supplied with compression fittings for direct connection to copper pipework.3 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.4 Maximum solar panel area is calculated based on 25l/m2 of net solar panel area.

Stainless Lite Horizontal Indirect and Solar Technical Specification

Description IND180 IND210 IND250 IND300IND180

SOLIND210

SOLIND250

SOLIND300

SOL

Product Stock Code ASL0050H ASL0055H ASL0060H ASL0065H ASL0090H ASL0095H ASL0100H ASL0105H

Energy Efficiency Class C C C C C C C C

Heat Loss watts 78 82 86 91 78 82 86 91

Capacity litres 176 207 246 296 174 208 244 294

Overall Height mm 585 585 585 585 585 585 585 585

Overall Width mm 1310 1495 1745 1992 1310 1495 1745 1992

Diameter mm 550 550 550 550 550 550 550 550

Weight (empty) kg 27 31 35 46 34 34 35 46

Weight (full) kg 203 238 281 342 205 242 279 340

Pressure regulator bar 3 3 3 3 3 3 3 3

Expansion vessel size litres 18 24 24 35 18 24 24 35

kW rating of primary coil kW 18.4 20.9 20.3 21.6 15.4 16.0 20.2 17.7

Heat up time min 27 27 36 32 21 24 38 26

Surface area of solar coil

m2 n/a n/a n/a n/a 0.49 0.49 0.59 0.59

Dedicated solar volume litres n/a n/a n/a n/a 64 85 112 145

11

StainlessLite HPStainless steel unvented cylinder designed for use with heat pumps

Gledhill have expanded its range of unvented stainless steel

units specifically for heat pump applications by developing

a model with an increased size heat exchanger to maximise

the lower temperatures available from the heat pump.

The heat exchanger is a new design, and has been

increased up to 4 square metres in the largest units,

maximising the heat exchange.

Due to the fact that many heat pumps will not raise the

stored water temperature to 60˚C, which is necessary to

prevent the growth of legionella, the Stainless Lite HP model

is supplied with an immersion heater and a thermostat. It

is recommended that a thermostat is fitted which brings the

immersion heater ‘on’ at a temperature just below the heat

pump maximum and switches off at 60˚C or 65˚C.

Stainless Lite HP Technical Specification

Description HP180IND HP210IND HP250IND HP300IND HP400IND

Product Stock CodeASL180HP

2.5SQMASL210HP

3SQMASL250HP

3SQMASL300HP

3SQMASL400HP

4SQM

Energy Efficiency Class B C C C D

Heat Loss watts 54 65 75 85 118

Capacity litres 180 210 250 300 400Height mm 1305 1495 1745 1992 2030Diameter mm 550 550 550 550 630Weight (empty) kg 33 38 43 58 62Weight (full) kg 213 248 293 358 462Pressure regulator bar 3 3 3 3 3Expansion vessel size litres 18 24 24 35 2 X 24kW rating of heat pump coil kW 16.74 17.91 15.93 13.18 18.87Heat pump coil pressure loss bar 0.04 0.05 0.06 0.05 0.07Surface area of heat pump coil m2 2.5 3 3 3 4

Model Selection Guide

Maximum hot water demand Bedrooms Model

1 bathroom 1-3 HP180IND1 bathroom & separate shower room 2-3 HP180IND1 bathroom & 2 separate shower rooms 2-3 HP180IND2 bathrooms & separate shower room 2-4 HP210IND2 bathrooms & 2 separate shower rooms 2-4 HP250IND2 bathrooms & 2 separate shower rooms 3-5 HP300IND2 bathrooms & 3 separate shower rooms 4-5 HP400IND

Notes:

1 All connections are supplied with compression fittings for direct connection to copper pipework.2 Thesuggestedmodelsizesshownarebasedonatypicaldayshotwateruseassumingthattheheatpumpwillheatthedomestichotwatertoapproximately50˚C.3 HeatpumpkWratingperformedat80˚Cand0.25l/s.

12

StainlessLite HP SOLUnvented cylinders designed for use with heat pump and solar technology

Gledhill have produced an unvented stainless steel unit

specifically for heat pump applications providing mains

pressure domestic hot water. Utilising the well established

Gledhill Stainless Lite unvented hot water cylinder, this

product has been developed to maximise the lower

temperatures available from the heat pump.

The heat exchanger is a totally new design. It consists

of a multi-pass corrugated stainless steel tube in parallel

to reduce the pressure loss whilst maximising the heat

exchange. Many medium to large heat pumps need heat

exchangers in the store that will cope with the higher flow

rates associated with primary temperatures that are typically

50˚C or 60˚C.

All the usual features of the Gledhill Stainless Lite are

maintained together with all the necessary controls and

expansion devices included.

Due to the fact that many heat pumps will not raise the

stored water temperature to 60˚C, which is necessary to

prevent the growth of legionella, the Stainless Lite HP model

is supplied with an immersion heater and a thermostat.

It is recommended that a thermostat is fitted which brings the

immersion heater ‘on’ at a temperature just below the heat

pump maximum and switches off at 60˚C or 65˚C. In this

way the use of ‘direct’ electricity is minimised and most of the

water heating is achieved through the heat pump.

The key features of the Stainless Lite HP SOL are:

• The latest and highest quality Duplex Stainless Steel.

• A 25 year guarantee.

• Fast reheat rate from its purpose designed low

resistance coil.

• One of the highest insulation ratings on offer today.

• The Stainless Lite HP SOL is supplied with all the

necessary connections including two dry thermostat

pockets.

13

Solarpumping

station

Solar circuitzone valve

Central heating�ow and return

Central heating zone valve

Heat pump

PRV

Expansionvessel

Hot water zone valve

System pump

PRV

Primary circuitsealed system kit

Stainless Lite HP system (with optional solarpanels) for use on a sealed heating system.(See our Technical Manual for otherinstallation options)

Stainless Lite HP SOL system (with optional solar panels) for use on a sealed heating system.

Stainless Lite HP SOL Technical Specification

Description HP180INDSOL HP210INDSOL HP250INDSOL HP300INDSOL HP400INDSOL

Product Stock Code ASL180HP ASL210HP ASL250HP ASL300HP ASL400HP

Energy Efficiency Class B C C C D

Heat Loss watts 54 65 75 85 118

Capacity litres 180 210 250 300 400Height mm 1305 1495 1745 1992 2030Diameter mm 550 550 550 550 630Weight (empty) kg 33 38 43 49 61Weight (full) kg 213 248 293 349 461Pressure regulator bar 3 3 3 3 3Expansion vessel size litres 18 24 24 35 2 X 24kW rating of heat pump coil kW 24.3 26.2 27.5 34.2 47.2Heat pump coil pressure loss bar 0.048 0.054 0.060 0.019 0.027Surface area of heat pump coil m2 1.36 1.56 1.94 2.04 2.91Surface area of solar coil m2 0.680 0.680 0.970 0.970 1.270Dedicated solar volume litres 65 75 90 105 130

Model Selection Guide

Maximum hot water demandMaximum solarpanel area (m2)

BedroomsModel (without

solar heating input)Model (with solar

heating input)

1 bathroom 2.6 1-3 HP180INDSOL HP180INDSOL1 bathroom & separate shower room 3.0 2-3 HP180INDSOL HP210INDSOL1 bathroom & 2 separate shower rooms 3.6 2-3 HP180INDSOL HP250INDSOL2 bathrooms & separate shower room 4.2 2-4 HP210INDSOL HP300INDSOL2 bathrooms & 2 separate shower rooms 5.2 2-4 HP250INDSOL HP400INDSOL2 bathrooms & 2 separate shower rooms - 3-5 HP300INDSOL -2 bathrooms & 3 separate shower rooms - 4-5 HP400INDSOL -

Notes:

1 All connections are supplied with compression fittings for direct connection to copper pipework.2 Thesuggestedmodelsizesshownarebasedonatypicaldayshotwateruseassumingthattheheatpumpwillheatthedomestichotwatertoapproximately50˚C.3 When connecting to solar heating input, it is important to check the dedicated solar volume is suitable for the total floor area to comply with Building Regulations.4 The Stainless Lite HP units are the same whether you are running solar thermal systems in conjunction with heat pump or just using a heat pump input only.5 The solar dedicated volume is only applicable when used in conjunction with solar thermal systems.6 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.7 Maximum solar panel area is calculated based on 25 l/m2 of net solar panel area.8 HeatpumpkWratingperformedat80˚Cand0.25l/s.

14

Slimline Heat PumpStainless steel unvented heat pump cylinders designed for restricted spaces

In situations where you want to upgrade a standard cylinder

with a heat pump installation, you will constantly come up

against the problem of installing a standard diameter unit

into a small cupboard space, common in older properties.

As a result, in addition to our existing Stainless Lite standard

heat pump range, we have developed the new Stainless Lite

Slimline HP which has a reduced diameter of 475mm.This

now enables installers to fit the new cylinders into smaller

properties or older homes where there are space limitations,

and so provide the benefits of mains pressure hot water.

The new range of Stainless Lite Slimline HP cylinders come

in 180 litres and 210 litres sizes.

Utilising the well established Gledhill Stainless Lite unvented

hot water cylinder, this product has been developed to

maximise lower temperatures available from the heat pump.

Although the cylinder has a reduced diameter, it still has

Model Selection Guide

Maximum hot water demand Bedrooms Model

1 bathroom 1-3 HP180SL1 bathroom & separate shower room 2-3 HP180SL1 bathroom & 2 separate shower rooms 2-3 HP180SL2 bathrooms & separate shower room 2-4 HP210SL

Notes:

1 All connections are supplied with compression fittings for direct connection to copper pipework.2 Thesuggestedmodelsizesshownarebasedonatypicaldayshotwateruseassumingthattheheatpumpwillheatthedomestichotwatertoapproximately50˚C.3 HeatpumpkWratingperformedat80˚Cand0.25l/s.

a 3m2 high performance corrugated coil which has been

specifically designed for maximum heat transfer. The heat

exchanger is a totally new design. It consists of a multi-

pass corrugated stainless steel tube in parallel to reduce

the pressure loss whilst maximising the heat exchange and

ensuring high flow rates essential to work with heat pumps.

Due to the fact that many heat pumps will not raise the

stored water temperature to 60˚C, which is necessary to

prevent the growth of legionella, the Stainless Lite Slimline

HP model is supplied with an immersion heater and a

thermostat.

It is recommended that a thermostat is fitted which brings the

immersion heater ‘on’ at a temperature just below the heat

pump maximum and switches off at 60˚C or 65˚C. In this

way the use of ‘direct’ electricity is minimised and most of the

water heating is achieved through the heat pump.

Stainless Lite Slimline HP Technical Specification

Description HP180SL HP210SL

Product Stock Code ASL180HPSL ASL210HPSL

Energy Efficiency Class C C

Heat Loss watts 76 84

Capacity litres 180 210Height mm 1790 1970Diameter mm 475 475Weight (empty) kg 33 37Weight (full) kg 213 247Capacity litres 180 210Pressure regulator bar 3 3Expansion vessel size litres 18 24kW rating of heat pump coil kW 32.8 31.2Heat pump coil pressure loss bar 0.018 0.018Surface area of heat pump coil m2 3.01 3.01

15

Buffer StoreVented store for use with heat pump systems

Buffer vessels are simply a duplex stainless steel tank that

contains a volume of water, increasing the overall volume of

the heating distribution system. This extra volume of water

is designed to absorb any extra heat generated by the heat

pump in low load conditions.

If the building cannot absorb the extra heat generated

the return temperature to the heat pump will increase

and will potentially cause the heat pump to turn off. If the

temperature drops in the water returning to the heating

appliance, then it will turn itself back on. If this cycling

occurs at a greater frequency than the minimum run time for

the appliance, this is classed as short cycling. The aim of a

buffer vessel is to remove the possibility of any short cycling

of the heating appliance.

These buffer vessels are designed to work at up to 3.5 bar

pressure for primary water only. They should not be used

for potable domestic hot water and are not approved for this

purpose.

Stainless Lite Direct Buffer Store Technical Specification

Description 90D 120D 210D 300D 400D

Product Stock Code ASLD90BUFFER ASLD120BUFFER ASLD210BUFFER ASLD300BUFFER ASLD400BUFFER

Energy Efficiency Class B B C C D

Heat Loss watts 35 44 65 85 118

Capacity litres 90 120 210 300 400

Height mm 745 930 1495 1992 2030

Diameter mm 550 550 550 550 630

Weight (empty) kg 13 18 28 37 51

Weight (full) kg 103 138 238 337 451

Stainless Lite Indirect Buffer Store Technical Specification

Description 120IND 210IND 300IND 400IND

Product Stock Code ASLIND120BUFFER ASLIND210BUFFER ASLIND300BUFFER ASLIND400BUFFER

Energy Efficiency Class B C C D

Heat Loss watts 44 65 85 118

Capacity litres 120 210 300 400

Height mm 930 1495 1992 2030

Diameter mm 550 550 550 630

Weight (empty) kg 22 33 44 55

Weight (full) kg 142 243 344 455

16

Flexible Buffer StoreVented store for use with multiple heat pumps or additional heat sources

Stainless Lite Flexible Buffer Store Technical Specification

Description 90FLX 120FLX 210FLX 250FLX 300FLX 400FLX

Product Stock Code ASL90BUF ASL120BUF ASL210BUF ASL250BUF ASL300BUF ASL400BUF

Energy Efficiency Class B B C C C D

Heat Loss watts 35 44 65 75 85 118

Capacity litres 90 120 210 250 300 400

Height mm 745 930 1495 1745 1992 2030

Diameter mm 550 550 550 550 550 630

Weight (empty) kg 13 18 28 32 37 51

Weight (full) kg 103 138 238 282 337 451

Maximum working pressure - cylinder bar 3.5 3.5 3.5 3.5 3.5 3.5

Maximum working pressure - space heating bar 3.5 3.5 3.5 3.5 3.5 3.5

Tappings mm 28 28 35 35 35 35

UpperPlain PipeConnections

LowerPlain PipeConnections

High LevelStat

Low LevelStat

InspectionHatch

22mm Compression

½ " BSPFitting forDrain Valve

The Buffer Store range has been extended providing

multiple connections. This not overcomes the issue of

connecting multiple heat pump units to a single store, but

you are now also able to connect a wood burning stove

and open vented gas boiler (subject to correct controls

being installed), making the Flexible Buffer Store the perfect

solution. This allows you to utilise multiple heat sources to

boost the temperature of the water within the store initially

generated by the heat pumps.

In addition to the multiple inputs, the Flexible Buffer Store

also allows installers to connect a heating circuit to the

cylinder to provide heating to the property.

These buffer vessels are designed to work at up to 3.5 bar

pressure for primary water only. They should not be used

for potable domestic hot water and are not approved for this

purpose.

17

StainlessLite Triple CoilOpen vented cylinders for use with multiple heat sources

Stainless Lite Triple Coil Technical Specification

Description IND300-STC IND400-STC

Product Stock Code

Energy Efficiency Class C D

Heat Loss watts 85 118

Capacity litres 300 400

Height mm 1992 2030

Diameter mm 550 630

Weight (empty) kg 46 60

Weight (full) kg 346 460

kW rating of primary coil kW 20.5 20.5

Surface area of solar coil m2 0.97 1.27

Dedicated solar volume litres 100 150

Maximum solar panel area m2 4.0 6.0

Notes:

1 All connections are supplied with compression fittings for direct connection to copper pipework.2 When selecting a solar model, it is important to check the dedicated solar volume is suitable for either the total floor area of the dwelling or the total net area of the

solar panel to ensure compliance with Building Regulations.3 Maximum solar panel area is calculated based on 25l/m2 of net solar panel area.

To satisfy the growing demand for a stainless steel cylinder

being capable of accepting multiple heat sources, Gledhill

has developed a triple coil version of the Stainless Lite

cylinder, which can accept solar and uncontrolled heat

sources such as solid fuel or wood burning appliances.

The cylinder has a dedicated solar coil at the bottom of

the cylinder. It then has a double coil for the solid fuel heat

supply and a single coil for the gas/oil boiler. It also has a

back up heat source in the form of an immersion heater.

The three separate coils will work independently providing

the maximum heat to the store, and subsequently reduce

the households fuel bills. The boiler coil and solar coil are

both 22mm and the solid fuel gravity circulation are 28mm.

18

StainlessLite VentedUnvented cylinders converted for use with uncontrolled heat sources

The only difference between the vented and unvented range

of Stainless Lite cylinders is that instead of being supplied

with the unvented kit, the vented option is supplied with a

control thermostat and a drain valve.

The technical and dimensional data for the Stainless Lite

vented is the same as the Stainless Lite and Stainless Lite

Solar, both of which are available in direct and indirect

configurations. Full technical details can be found on pages

5-8 in this brochure.

The Stainless Lite vented option provides a high quality

open vented stainless steel cylinder for use in a traditional

vented cylinder installation. As an open vented cylinder, it

also permits the connection of an uncontrolled heat source

such as a solid fuel or wood burning appliance, which is not

permitted with an unvented cylinder. Please note when using

in this application, a fully pumped system will be required.

The traditional vented storage water heater has a proven

track record of reliability and safety. The operating pressure

is dictated by the vertical distance between the cistern tank

and the bottom of the heater.

The open vented system is renowned for its safety because

the open vent that discharges in to the cistern tank

automatically equalises any excess pressure or vacuum.

The Stainless Lite vented cylinder is fully compliant with

2010 Part L regulations, therefore it now enables you to fit a

vented cylinder into a new build property.

19

Up against time to replace that cylinder?

The required model is not stocked at the

merchant?

Then the obvious choice has to be

the complete cylinder service

PLACE YOUR ORDER STOCKED LOCALLY DELIVERED NEXT DAY

* The same day collection service is subject to orders before 1pm** Not applicable to all postcode regions in Scotland, please speak to Inverkeithing depot for further details

Ordering your urgently required unvented cylinder couldn’t be simpler;

• Place your order at the merchant• Order is sent to one of our nationwide depots where the core range

of cylinders stocked• Same day collection available from the local depot*• Next day delivery to any mainland UK address at no extra cost**

“Only the bestis acceptable” FM 02057

Blackpool

Head Office and

Stainless Steel Manufacturing Site

Blackburn

Telephone: 01254 693844

Fax: 01254 673615

Bristol

Telephone: 01179 820814

Fax: 01179 820821

Inverkeithing

Telephone: 01383 414133

Fax: 01383 413123

Luton

Telephone: 01582 728253

Fax: 01582 318976

Maidstone

Telephone: 01622 714770

Fax: 01622 882286

UK Super Depot InfrastructureNottingham

Telephone: 01773 580684

Fax: 01773 581129

Oldbury

Telephone: 01384 636245

Fax: 01384 413700

Paignton

Telephone: 01803 557470

Fax: 01803 559213

Southampton

Telephone: 01329 846601

Fax: 01329 845881

For technical adviceplease call

01253 474584

SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Gledhill Building Products LimitedSycamore Estate, Squires Gate, Blackpool FY4 3RL Tel: 01253 474550 Fax: 01253 474551 [email protected]

Due to a programme of continuous improvement Gledhill Building Products reserve the right to modify products without prior notice.It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website.

It is an offence to copy or adapt this document without consent of the owner.

Gledhill Building Products produce cylinders for use with a wide range of heat sources including;

Gas and oil boilers Electricity Air source heat pumps Ground source heat pumps Solar energy Wood burning stoves

Further information on Gledhill products can be found on the internet at www.gledhill.net

Spec 103/09 09/15