staple-line reinforcement dan geisler, md, facs, fascrs west penn allegheny health system

20
Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

Upload: liliana-barton

Post on 24-Dec-2015

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

Staple-Line Reinforcement

Dan Geisler, MD, FACS, FASCRSWest Penn Allegheny Health System

Page 2: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

2

Disclosures

Covidien Consultant

Page 3: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

3

Staple Line Reinforcement

WHY?

Anastomotic Leak

Staple Line Bleeding

Page 4: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

4

Staple Line Reinforcement

WHAT?Synthetic, bioabsorbable staple-line

reinforcementCollagen matrixPolyglycolic acid

Page 5: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

5

Staple Line Reinforcement

WHAT?Gore SeamguardSynovis Staple Line ReinforcementCook biodesign staple line reinforcementCovidien Duet TRS

Page 6: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

6

GORE SeamguardBioabsorbable Staple Line Reinforcement

• Synthetic Absorbable• Sleeves (“socks”) held by non-absorbable

polyester braided suture• Increases thickness of tissue by up to 0.5mm

Page 7: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

7

Staple Line Reinforcement

Synovis® Peri-Strips Dry®• Biologic tissue prepared from bovine pericardium

(U.S. cattle)• Strips attached by gel (“glue”)• Increases thickness of tissue by 0.5mm to 1.5mm

Synovis® Peri-Strips Dry® with Veritas® Collagen Matrix• Prepared from dehydrated bovine pericardium (U.S.

cattle)• Similar assembly to Peri-Strips Dry®

Page 8: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

8

Staple Line Reinforcement

PeriPatch™ Aegis• Processed Bovine Pericardial Staple Line

Reinforcement• Made ONLY for Ethicon staplers

• (ETS/Flex 45 and Echelon 60)• Easier to assemble, but more preparation involved

(pre-soak)• IFU recommends use of 15mm trocar

PeriPatch™ Aegis EQ• Identical in design to PeriPatch™ Aegis, but it is

made from equine pericardium

Page 9: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

9

Staple Line Reinforcement

DUET Thinnest On the Market

• will increase the thickness of the tissue to be stapled by approximately 0.12mm – 0.18mm

Clear• easily view staple formation

Synthetic Absorbable• Consistent Thickness

Optimal Absorption Profile• Strength During Critical • Wound Healing Time

Page 10: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

10

Staple Line Reinforcement

WHAT?

Page 11: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

11 Covidien | April 19, 2023 | Confidential11 |

Duet Tissue Reinforcement – Absorption Profile

Reinforcement material is a synthetic absorbable film

• prepared from synthetic polyester composed of glycolide, dioxanone and trimethylene carbonate

• Measurable mechanical strength through 14 days

• Absorption should be complete between 90-110 days

Page 12: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

12

Page 13: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

13

Page 14: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

14

Staple Line Reinforcement

WHEN?High-risk anastomosisBleeding Anastomotic leaks

Page 15: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

15

Page 16: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

16

DATA?

Page 17: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

17

Staple Line Reinforcement

Gastric Bypass N = 1073 (568 bovine collagen matrix) Abdominal septic events

• 4% versus 1%• Staple line leakage• Purulent drainage• Abscess

Callery CD, Filiciotto S, Neil KL

Page 18: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

18

Staple Line Reinforcement

Colorectal Anastomosis N = 117 laparoscopic + open Circular bioabsorbable Seanguard 4 intraoperative leaks

Use of Seamguard may result in a lower incidence of anastomotic leakage

Portillo & Franklin

Page 19: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

19

Staple Line Reinforcement

Colorectal Anastomosis

“most…need to be accepted and optimized”

“not much experience…further investigation

is needed”

Page 20: Staple-Line Reinforcement Dan Geisler, MD, FACS, FASCRS West Penn Allegheny Health System

20

Staple Line Reinforcement

Seems promising

Preventing leakage + bleeding

More studies are needed