Journal of Electronics Cooling and Thermal Control, 2013, 3, 144-154 Published Online December 2013 (http://www.scirp.org/journal/jectc) http://dx.doi.org/10.4236/jectc.2013.34016 Open Access JECTC STAR CCM+ CFD Simulations of Enhanced Heat Transfer in High-Power Density Electronics Using Forced Air Heat Exchanger and Pumped Fluid Loop Cold Plate Fabricated from High Thermal Conductivity Materials Kevin R. Anderson 1 , Matthew Devost 1 , Watit Pakdee 2 , Niveditha Krishnamoorthy 3 1 Nonlinear FEA/CFD Multi-Physics Simulation Laboratory, Department of Mechanical Engineering, California State Polytechnic University, Pomona, USA 2 Department of Mechanical Engineering, Faculty of Engineering, Thammasat University (Rangsit Campus), Bangkok, Thailand 3 CD-Adpaco, One Technology Drive, Irvine, CA, USA Email: [email protected], [email protected], [email protected], [email protected] Received November 12, 2013; revised December 5, 2013; accepted December 12, 2013 Copyright © 2013 Kevin R. Anderson et al. This is an open access article distributed under the Creative Commons Attribution Li- cense, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT As telecommunication and RF power electronics applications continue to push the envelope of waste heat dissipation, more and more, we see a need for active thermal control employing forced air electronic cooling fans in unison with pumped fluid loops in order to meet temperature and performance requirements. This research paper presents results of applying Computational Fluid Dynamics (CFD) commercial industry STAR-CCM+ software for heat transfer and fluid flow simulation of a novel heat exchanger/cold plate fabricated from k-core high thermal conductivity material in order to realize thermal control system hardware design for very much applications to very large power density (~1 kW/m 2 ) electronics packaging scenarios. Trade studies involving different heat exchanger/cold plate materials, as well as vari- ous fault scenarios within a mock-up of a typical electronics system, are used to illustrate the upper bounds placed on the convective heat transfer coefficient. Agreement between our present findings and previous research in the field of electronics cooling is presented herein. Keywords: CFD; High Thermal Conductivity; Heat Sink; Cooling Plate; Thermal Control 1. Introduction The novelty of the current research focuses on a system’s level approach to using CFD to examine “cause-and-ef- fect” scenarios in an electronics cooling application. In particular, our thermal control solution uses a very high thermal conductivity material known as “k-core” [1] in order to implement a heat exchanger/cold plate used to cool high power density electronics packaging. Effective heat spreading has been implemented by previous inves- tigators interested in heat transfer augmentation includ- ing the work of [2], which used anisotropic heat plate with preferential thermal conductivity to augment thermal per- formance. In the study of [3], the critical heat flux of a heat spreader was quantified. While in [4], the use of dia- mond coated materials was researched. This current paper utilizes Computational Fluid Dynamics (CFD) in order to study various causes and effects at a system’s le- vel. The CFD work related to electronics currently avai- lable in the literature can be broken into the following categories based on level of characteristic thermal/fluid length scale, or overall size of the hardware being analy- zed: MEMS level; chip/component level; Printed Circuit Board (PCB) board level; hand-held devices (cell phones, instrumentation, etc.); desk-top computer level; interme- diate compact packaging level; rack-mounted server le- vel; very large length scale (i.e. power grid distribution applications, etc.). Herein we are interested in the inter- mediate compact packaging level. At the chip/component/PCB level, various researchers have used CFD to study electronics cooling with the use of a heat sink including the work of [5], which imple-

Upload: others

Post on 12-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

Journal of Electronics Cooling and Thermal Control, 2013, 3, 144-154 Published Online December 2013 (http://www.scirp.org/journal/jectc) http://dx.doi.org/10.4236/jectc.2013.34016

Open Access JECTC

STAR CCM+ CFD Simulations of Enhanced Heat Transfer in High-Power Density Electronics Using Forced Air Heat Exchanger and Pumped Fluid Loop Cold Plate Fabricated

from High Thermal Conductivity Materials

Kevin R. Anderson1, Matthew Devost1, Watit Pakdee2, Niveditha Krishnamoorthy3 1Nonlinear FEA/CFD Multi-Physics Simulation Laboratory, Department of Mechanical Engineering,

California State Polytechnic University, Pomona, USA 2Department of Mechanical Engineering, Faculty of Engineering,

Thammasat University (Rangsit Campus), Bangkok, Thailand 3CD-Adpaco, One Technology Drive, Irvine, CA, USA

Email: [email protected], [email protected], [email protected], [email protected]

Received November 12, 2013; revised December 5, 2013; accepted December 12, 2013

Copyright © 2013 Kevin R. Anderson et al. This is an open access article distributed under the Creative Commons Attribution Li- cense, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

ABSTRACT

As telecommunication and RF power electronics applications continue to push the envelope of waste heat dissipation, more and more, we see a need for active thermal control employing forced air electronic cooling fans in unison with pumped fluid loops in order to meet temperature and performance requirements. This research paper presents results of applying Computational Fluid Dynamics (CFD) commercial industry STAR-CCM+ software for heat transfer and fluid flow simulation of a novel heat exchanger/cold plate fabricated from k-core high thermal conductivity material in order to realize thermal control system hardware design for very much applications to very large power density (~1 kW/m2) electronics packaging scenarios. Trade studies involving different heat exchanger/cold plate materials, as well as vari- ous fault scenarios within a mock-up of a typical electronics system, are used to illustrate the upper bounds placed on the convective heat transfer coefficient. Agreement between our present findings and previous research in the field of electronics cooling is presented herein. Keywords: CFD; High Thermal Conductivity; Heat Sink; Cooling Plate; Thermal Control

1. Introduction

The novelty of the current research focuses on a system’s level approach to using CFD to examine “cause-and-ef- fect” scenarios in an electronics cooling application. In particular, our thermal control solution uses a very high thermal conductivity material known as “k-core” [1] in order to implement a heat exchanger/cold plate used to cool high power density electronics packaging. Effective heat spreading has been implemented by previous inves- tigators interested in heat transfer augmentation includ- ing the work of [2], which used anisotropic heat plate with preferential thermal conductivity to augment thermal per- formance. In the study of [3], the critical heat flux of a heat spreader was quantified. While in [4], the use of dia- mond coated materials was researched. This current

paper utilizes Computational Fluid Dynamics (CFD) in order to study various causes and effects at a system’s le- vel. The CFD work related to electronics currently avai- lable in the literature can be broken into the following categories based on level of characteristic thermal/fluid length scale, or overall size of the hardware being analy- zed: MEMS level; chip/component level; Printed Circuit Board (PCB) board level; hand-held devices (cell phones, instrumentation, etc.); desk-top computer level; interme- diate compact packaging level; rack-mounted server le- vel; very large length scale (i.e. power grid distribution applications, etc.). Herein we are interested in the inter- mediate compact packaging level.

At the chip/component/PCB level, various researchers have used CFD to study electronics cooling with the use of a heat sink including the work of [5], which imple-

Page 2: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 145

ments CFD to characterize the performance of carbon composite and copper heat sinks on the heat transfer in a computer CPU. The work of [6] utilizes CFD to perform trade studies on the modeling of finned heat sinks, while [7] has married experimental and CFD analysis to quan- tify the effects of heat sinks and base plates on heat tran- sfer behavior. Finally the work of [8] performs CFD and presents heat transfer correlations for the optimization of fin heat sinks. At a desk-top computer level, CFD has been used to study the heat transfer in computer chassis and computer box such as the work in [9] which focus- es on computer chassis heat transfer performance. The study of [10] implements CFD to investigate PCB heat transfer in a computer. The study of [11] investigates computer heat transfer and cooling using a heat-pipe. More generic analyses of using CFD to electronic sys- tems are given in the work of [12-14], wherein system’s level analysis is performed using CFD to gain insight on heat transfer and thermal performance of various elec- tronic devices, ranging from hand-held devices to desk- top computers. The tutorial offered by [15] allows the novice to gain insight on how to use electronics pac- kaging design lay-out strategies to realize more effective heat transfer flow field patterns. In the arena of rack mounted servers, several pertinent CFD based investiga- tions have been carried out over the last decade or so. The most noteworthy of these is the study of [16], where- in a CFD tool is implemented to study the temperature distribution in rack mounted servers. The investigation of [17] uses a liquid cooling thermal management system to enhance the heat transfer in a rack cooling data center application, while the work of [18] outlines a road-map for future CFD work related to rack mounted cooling systems. For the intermediate length scale, the works of [19,20] address this type of hardware, but the studies only address moderate power density heat transfer ther- mal control strategies. The work of [19] includes the fi- delity of the thermal vias, solder, PCB, and shelf inter- face. Other applications of using numerical heat transfer and CFD in electronic and avionic systems are given in [21,22]. Presently, there appears to be a void of CFD si- mulation databases addressing the so-called intermediate application level. The goal of this current study is to ad- dress this absence of literature by simulation of an inter- mediate sized electronics enclosure, which is subject to very large power densities. This is in an effort to address the ever changing requirements of affording more power in a smaller packaging level.

To date, CFD of intermediate level packaging high- power density enclosures has not been carried out com- prehensively. Furthermore, there have been few or no CFD simulations of electronics cooling using CD-Adapco’s STAR-CCM+ CFD software in the literature, mainly ICEPAK and FLOTHERM, which have the tools of

choice as evidenced in the works of [5,6,9,12-15]. To address this absence in the literature, the current CFD simulations focus on using STAR-CCM+ CFD to simu- late heat transfer and fluid dynamic behavior in interme- diate sized Telecommunication/Observatory Science/Elec- tronics/RF/Avionics systems fabricated primarily from COTS (Commercially Available Off The Shelf) compo- nents (i.e. fans, heat-sinks, cold plates, etc.) to implement the thermal control solution. This current study focuses on cost-effective thermal control system alternative, in contrast to more cost-prohibitive solutions such as those involving heat pipes, nano-fluids and/or phase change materials. The current study uses CFD to quantify the ef- fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios.

2. Heat Spreader Thermal Technology

Herein, “k-core” thermal conduction plates available from Thermacore, Inc. [1] are used in conjunction with a pumped fluid loop to illustrate the effects of heat transfer spreading. K-core heat spreader cold plates afford high- efficiency heat transfer in the absence of moving parts, and are invaluable in applications where space, volume, seamless hardware integration and weight constraints dictate thermal design solutions. Physically, k-core base heat spreader cold plates transfer heat from sources such as high power dissipating electronic components, reject- ing it to ambient air (through forced or natural convec- tion) or liquid coolants (water, glycol/water mixtures, dielectric fluids, polyalphaolefin or PAO). These types of k-core cold plates are well suited for operating in harsh environments, including extreme temperatures/humidity, shock and vibration. For cooling high-power density ap- plications, such as semiconductors, lasers, power genera- tion, medical equipment, transportation, military elec- tronics, etc., and other demanding applications where air cooling is insufficient, liquid cooling (pumped fluid loop) is essential. In this case Thermacore k-core based liquid cooled cold plates offer a feasible thermal control system solution. Thermacore’s custom liquid cooling component cold plates include tube-in-plate, aluminum vacumn- brazed and copper brazed types for various applications. Tube-in-plate cold plate materials consist of copper or stainless steel tubes pressed into a channeled aluminum or copper extrusion or machined plate. Thermacore also offers copper cold plates that incorporate vertical fin (micro-channel) technology or, for higher performance, our specialized powdered metal construction. Therma- core’s custom liquid-cooled assemblies are designed spe- cifically for each application’s unique thermal/mechanic- cal requirements. The physical concept of Thermacore’s k-core heat transfer technology is illustrated in Figure 1.

Open Access JECTC

Page 3: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 146

Figure 1. Thermacore k-core technology [1].

Figure 1 shows the various thermal technologies of- fered by Thermacore, Inc. Using Encapsulated Annealed Pryrolytic Graphite (APG) allows one to manufacture a device such as a heat spreader with heat sink integrated on one face while a labyrinth of tubing for a pumped fluid loop can be fabricated on the opposing face.

The encapsulant of Figure 1 sets the Coefficient of Thermal Expansion (CTE) and other structural properties. The encapsulant material is selected to satisfy require- ments such as ease of integration into the overall system. Since the APG is anisotropic in thermal conductivity, i.e. the x-component, and y-component of thermal conduc- tivity is very large with respect to the y-component of the thermal conductivity, the APG acts as an excellent me- chanism with which to realize heat transfer enhancement via preferential heat spreading. Figure 2 illustrates the temperature dependency of the thermal conductivity of APG.

From Figure 2 it can be seen the APG has its largest thermal conductivity at 150 K (−123 C) where k= 2800 W/m-K making is a valuable thermal heat transfer mate- rial for spacecraft applications. For electronics cooling applications where the nominal temperature is on the range of 350 to 400 K (77 C to 127 C) the APG has a thermal conductivity of k = 1500 W/m-K (as compared to Copper have k = 400 W/m-K, and Aluminum = 200 W/m-K). In this current study we investigate the use of APG k-core technology for temperatures in the range of 266 K to 373 C (29 C to 100 C), k = 1600 W/m-K to k = 1100 W/m-K.

3. System Hardware Description

Figure 3 shows the layout of the electronics being inves-tigated in this paper. The configuration of Figure 4 was selected in order to mimic an intermediately sized high power density power electronics application. The overall system consists of a very large housing with eight iden-tical sub-modules arranged in order to minimize overall system volume. The sub-modules were each populated with various components, totaling twelve each per sub- module. These components were left to be very generic

Figure 2. Thermal conductivity for APG material [1].

Figure 3. Fan curve specifications for thermal control hard- ware simulations.

COLD PLATE

HEAT SINK

ENCLOSUREFAN INLETS

Figure 4. Electronics System Components. in order to facilitate our trade study involving simulation of system level electronics using CFD.

As seen in Figure 4, the thermal control system is comprised of three major components; the heat sink, the cold plate and the forced convection fans/housing enclo- sure. The majority of heat transfer removal capacity is accomplished via the forced convection air flow of the fans, while the cold plate serves to hold a constant boun- dary temperature in order to act as a heat sink. This en- closure measures overall dimensions W*L*H = 0.5 m by 1.0 m by 0.5 m (19.7 inches by 39.4 inches by 19.7

Open Access JECTC

Page 4: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 147

inches, thus it is roughly the size of a foot-locker, smaller than a typical rack-mounted server, and larger than a typical PC workstation tower. As is traditionally done in practice in electronics manufacturing, no particular atten- tion was paid to the exact layout of the overall system, i.e. the eight sub-modules were placed into the overall en- closure in a staggered configuration. This of course is not optimum, since some components on some of the sub- modules will be exposed to fans while others will not. The effects of material selection for the manufacturing of the heat exchanger and fluid loop cold plate has profound ramifications on the optimization of the heat transfer enhancement of the electronics package as a whole. Thus, the current study focuses on the effects of using the pre- viously motivated APG k-core high thermal conductivity material in the fabrication of an integrated heat ex- changer, cold plate on the convection heat transfer coef- ficient (aka h-value) in electronics cooling applications.

The CFD simulations presented herein utilized fully 3-d conjugate heat transfer; forced external air convec- tion; forced internal cooling loop; solid conduction; sur- face to surface gray body radiation, turbulent. To mimic typical COTS cooling fans, the fan-curve of Figure 3 below was used in the simulations. Figure 3 gives fan- curve characteristics for a fan rated at 30 kg/sec with 50 Pa static pressure (60 cfm with 0.2 inches W.G.).

The parametric trade space investigated over the course of our investigation is shown below in Table 1.

The electronics power listed as 500 to 1000 W in Ta- ble 1 was accomplished as per the following example, for a 720 W system, each component was assign 7.5 W, thus 7.5 W/component*12 components/sub-module*8 sub-modules/housing*1 housing = 720 W. Using the footprint of 1 m*0.5 m of the cold plate, this affords and electronics power density of 1440 W/m^2. According to Figure 5, the viable technologies for a tolerated tem- perature delta of 20 C involves direct air, forced convec- tion, while for temperature deltas on the order of 100 C, a Table 1. Parametric trade space for k-core thermal control system study.

Parameter Range

Electronics Power (W) 500 - 1000

Electronics Power Density (Kw/m2) 1 - 2

Inlet Air Flow (m/s) 5 - 15

Inlet Air Temperature (˚C) 10 - 20

Water Inlet Temperature (˚C) 10 - 20

Water Inlet Flow Rate (kg/s) 0.10 - 0.20

Heat Sink Thermal Conductivity (W/m-k) 200 - 1100

Cold Plate Thermal Conductivity (W/m-k) 200 - 1100

Figure 5. Roadmap of thermal technologies [23]. hybrid of forced air and natural convection in addition to radiation is recommended. However, in spacecraft and terrestrial applications of high power density heat trans- fer there is no gravity, thus natural convection cannot be relied on. Additionally, radiation effects in the presence of forced convection have been found to be minimal by prior CFD investigations [9,12,14].

Thus a hybrid solution of forced convection and highly thermally conductive heat sink/pumped fluid looped ther- mal control system architecture is proposed herein to ad- dress spacecraft and terrestrial and avionics applications which continue to push the envelope of power size to area ratio to the extreme limits of today’s capable “state- of-the-art” technologies.

4. CFD Model Description

The CFD package STAR-CCM+ from CD-Adapco was used to import the system geometry of Figure 3. The workflow in STAR-CCM CFD modeling is mush the same as in other packages, such as ANSYS-FLUEN, Flo- therm, NX-Space Systems Thermal, COMSOL, etc. First the geometry is imported, then materials are assigned to components, boundary conditions are assigned, mesh is generated, solvers/models are selected, the equations of motion are then solved and results are post-processed. For the simulations outlined herein the STAR-CCM+ CFD software uses Polyhedral Unstructured Mesh with Prismatic Boundary Layer enhancement. The mesh used in the CFD simulations presented herein is shown below in Figure 6.

The software package STAR-CCM+ allows the user to specify the regions (parts) as well as the thermal interface between each part. The cooling fans are modeled in STAR-CCM using an in-place interface whereby in Fig-

Open Access JECTC

Page 5: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 148

ure 5 this is illustrated with the dark blue circles situated at the northwest portion of the diagram. These in-place interface fans allow the used to assign a fan-curve of the form of that given in Figure 5 to be keyed in as a poly- nomial curve fit. STAR-CCM+ also allows the user to model the swirl of the fan, however for this system’s level study, this option was found to be too computation- ally expensive, since we have three fans at the inlet of the housing to simulate. The impact of this modeling as- sumption if felt to be minimal, since our primary object- tive herein was to simulate the flow of air through the entire enclosure with a fan rated at a certain volumetric flow rate and static pressure drop, the use of interface fans is warranted. The study of swirl around the vicinity of the fans is not within the current scope of investiga- tion.

4.1. Grid Independence Study

Typical cell count for the system level CFD model was on the order of 2.5 million cells. Five prismatic boundary layer cells were employed to resolve the boundary layer at all solid-fluid interfaces. Various trades were run in order to determine the optimum mesh size, for 2.5 mil- lion polyhedral cells, a base element size of 0.01 m was used, mesh independence studies centered around this value were performed, i.e. the base element size was varied from 0.005 m (more cells, highest fidelity mesh) to 0.02 m (fewer cells, coarsest mesh). A monitor point was selected in the model, and the primitive variables were monitored as the cell size was halved, resulting in the choice of 0.01 m (2.5 million cells) as the baseline model size. CPU run-time on a 64-bit quad-core DELL PC workstation was on the order of six hours.

4.2. Governing Equations

Headings, The governing equations solved in STAR- CCM+ via the Finite Volume Method for our laminar, conjugate heat transfer simulations are the incompressi- ble Navier-Stokes equations stated below in continuous integral form

d dV

Vt

W F G a H dV

V (1)

Figure 6. CFD mesh used in simulations.

, ,

0

,

g

g

g

u

u

pI

E H p

S

T

T S

g

u u

W u F u u u

u u u

G H f

u q

(2)

where , , E, and p denote the density, velocity, total energy per unit mass, and pressure of the fluid, respect- tively. The parameter T is the viscous stress tensor, while

u

q denotes the heat flux vector and gu is the

grid velocity vector. The total energy is related to the total enthalpy via the caloric equation of state

p

HE (3)

where the total enthalpy is the sum of the internal energy and the kinetic energy via

2

2uTCH p (4)

For the remaining terms in the Navier-Stokes equation, denotes the body force vector, is the vector of

conserved quantities H W

F is the vector of inviscid terms, is the vector of viscous terms, G I is the identity ten-

sor, denotes the porosity, and is the dynamic viscos- ity. The constitutive equation modeling heat conduction in the solid bodies is taken to by Fourier’s Law stated below in differential form

k T q (5)

The above equations are implemented on an unstruc- tured polyhedral mesh and the resulting algrebraic equa- tions are solved using the algebraic multi-grid method.

5. Results

The results for temperature distribution, flow vectors and streamlines in our simulations are illustrated in Figures 7-9. The parameters for the simulation were as follows: each component has 7.5 W giving 720 W for 12 compo- nents and 8 sub-modules. Additionally, each PCB card had an additional 10 W of power applied to it, thus 80 W for the total package of eight cards. Hence, this simula-tion is 800 W over a 1 m × 0.5 m footprint giving 1600 W/m2 = 1.6 kW/m2, which is in the category of a very high power density application. Figure 7 shows the inlet air coming from the fans at 303 K (30˚C) and a heat sink/cooling plate temperature of 283 K (10˚C). Figure 8 shows the velocity vectors for the situation of Figure 7, while Figure 9 illustrates streamlines of the flow field for the system of Figure 7.

Open Access JECTC

Page 6: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 149

Figure 7. Component temperatures.

Figure 8. Velocity vectors colored by air speed and electro- nics components colored by temperature.

Figure 9. Streamlines colored by air stream speed and elec- tronics components colored by temperature.

The heat sink/cooling plate assemblage serve to keep the baseplate of the system at 10˚C, serving as an effect- tive heat sink. The isothermal contours of Figures 7-9 in- dicate that the components witness a maximum tempera- ture of 356.4 K (83.4˚C), thus there is temperature diffe- rence of 73.4˚C in this system. Next, a series of paramet- ric studies was completed each of which is discussed in detail below.

5.1. Effect of Thermal Conductivity on Heat Transfer

The primary objective of this current research is to dem- onstrate the heat spreading characteristics of APG k-core material. Thus, the CFD model described above was ex- ercised by changing the thermal conductivity of the heat sink/cold plate from a very low (bare Aluminum) to a very high value (APG k-core). The results of this para-

metric study are shown below in Figure 10 which shows the system temperature delta, T (˚C) plotted as a func- tion of the heat sink/cold plate thermal conductivity k (W/m-K).

By inspecting Figure 10 the spreading effects of APG k-core become immediately obvious. The relationship between thermal conductivity and maximum system tem- perature delta is expected to be linear via the relationship for heat conduction given by the first law of thermody- namics

thermal

1Q

RT (6)

where the thermal resistance for conduction and contact interface is given by

thermal contact conductioncontact

1 xR R R

h k

A (7)

The terms are written in series to indicate that the heat must flow from the heat sink via conduction to the cold plate with an intermediate resistance due to contact in be- tween them. For this study we assumed that the contact h-value for the contact conductance was very large, i.e. since the heat sink/cold plate will ultimately be fabrica- ted as one cohesive unit.

5.2. Heat Transfer Coefficient Comparison

One very important piece of information valuable to the electronics cooling community continues to be the elu- sive film convection heat transfer coefficients. To this end, Figure 11 shows values of convective heat transfer coefficient (W/m2-K) for a typical CFD simulation of our study. From Figure 11, the convective heat transfer val- ues are found to range from 20 < h < 70 W/m2-K for the sub-modules, PCB cards, and component assembly. These values are in agreement with the heat transfer literature [24] for systems of this category.

In order to quantify the effect of inlet fan air speed upon the heat transfer coefficient behavior, a series of

Figure 10. Thermal conductivity effect on heat spreading in CFD simulations.

Open Access JECTC

Page 7: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 150

Figure 11. Convective heat transfer coefficient contours. CFD simulation were performed whereby the flow rate of air was varied, thus resulting in a different average ve- locity emanating from the fan. Figure 12 shows the re- sults of our CFD simulations in comparison with the la- minar flat plate Nusselt number based correlation of [25]. The correlation of [25] is based on the Nusselt number for flat plate laminar flow, and is written as

0.00109V

hL

(8)

with V (ft/min) and L (in). As expected, the handbook correlation of [25] is conservative, i.e. it over predicts the heat transfer coefficient for the range of flow speeds in- vestigated. This is expected, as the uncertainty in a stan- dard textbook based correlation is at least 25% and that the handbook based correlations should not be viewed as sacrosanct [24]. The real mediation to resolve this uncer- tainty is to perform a system’s level test on actual engi- neering hardware, and then perform a correlation of the numerical model. The data from our CFD study are found to be in qualitative agreement with the simulations and correlations offered by the research of [11,26], which both present plots of Nusselt number versus Reynolds number (i.e. heat transfer coefficient versus flow speed) for heat sinks in electronics cooling applications.

Next, the heat transfer coefficient of the system is plotted against temperature delta of the system as shown in Figure 13. Figure 10 shows convective heat transfer coefficient h (W/m2-K) versus temperature delta (T-To). The CFD data points are assigned a power-law curve fit and compared to the correlation offered by [23]. The recommended correlation of [23] for electronics cooling is given by

1 4

2.44T

hL

(9)

As shown in Figure 13, the hand-book correlation of

Equation (9) is found to over-predict the heat transfer coefficient in the range of system temperature differences studied. At this point it should be reiterated that accord- ing to [24], the heat transfer correlations given by Equa- tion (8) and Equation (9) are expected to carry an uncer- tainty of at least 25%. Clearly, the agreement of our cur- rent CFD results in Figures 12 and 13 are within the realm of this uncertainty range.

5.3. Effect of Cold Plate Coolant Flow Rate

Next we investigate the effects of cold plate coolant flow rate on the system thermal performance. A series of CFD simulations were carried out varying the inlet flow rate of the water in the cold plate from 0.1 kg/sec to 0.2 kg/sec (1.6 gpm to 3.2 gpm for water with = 1000 kg/m3). The results are shown in Figure 14 where the heat transfer coefficient of the system is plotted as a function of the flow rate in the cold plate.

It should be clarified here that the influence of convec- tive heat transfer coefficient of the entire system, as shown in Figures 7-9, i.e. components and PC boards is plotted in Figure 14, rather than the internal heat transfer coefficient of the tubes comprising the cold plate. As can be seen in Figure 15 the heat exchanger/cold plate as- sembly maintains a relatively constant temperature dis- playing only a 5˚C overall spatial gradient. This is pri- mary advantage of utilizing a pumped fluid system cold plate apparatus, i.e. it gives one the ability to hold a somewhat isothermal boundary condition in an actual thermal system.

5.4. Effect of Contact Resistance

The next segment of our investigation deals with simula- tion of the thermal gasketing material comprising the contact conductance interface between the various com- ponents in the system. Typical thermal gasket materials used extensively in the commercial electronics cooling industry include Chotherm [26], Thermal Grease [27]

F igure 12. Heat transfer coefficient versus fan air speed.

Open Access JECTC

Page 8: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL.

Open Access JECTC

151

Figure 13. Heat transfer coefficient comparison.

Figure 14. Heat Transfer coefficient versus cold plate flow rate. and Grafoil [28]. These materials have advertised nomi- nal contact heat transfer coefficients of 5000 W/m2-K for Chotherm, 50,000 W/m2-K for Grafoil, and 10,000 W/m2-K. In practice it is best to apply an area void frac- tion of at least 50% to these nominal values in order to account for that fact that uniform pressure is not avai- lable between the two interfaces being mounted together. This puts a more conservative bounds of the values or thermal contact resistance for these materials as follows, R = 4 × 10−4 K-m2/W for Chotherm, R = 4 × 10−5 K-m2/W for Grafoil, and R = 2 × 10−4 K-m2/W for Thermal Grease. Using these values as guidance, CFD simulations were performed on the system level model, whereby all of the interfaces were set to have a contact interference with the values of contact resistance in the range 4 × 10−4 < R < 2 × 10−3 K-m2/W (2500 < h < 500 W/m2-K) thus emulating a “very good” thermal interface to a “very poor” thermal interface. These results are shown in Figure 16 which plots maximum temperature in the system versus thermal contact resistance.

As expected the trend of Figure 16 is linear, since the

thermal contact resistance is embedded in the conduction heat transfer model of Equation (7) as previously dis- cussed. Figure 17 shows isothermal contours for a sub- module which has a very poor thermal contact interface, i.e. R = 32 10 K-m2/K.

Figure 17 shows the range of temperatures, from smallest of 286 K (13˚C) where the PCB card is in con- tact with the heat sink/cold plate assembly, to a largest value of 350 K (77˚C) where the warmest component on the PCB is at the extremity of the PCB card near the air flow region. Here, the impact of a poor thermal contact interface is profound, leading to a 64˚C temperature spa- tial thermal gradient across this particular sub-model.

5.5. Thermal Runaway Due to Faulty Components

Thermal runaway due to faulty components in the system are readily simulated using a turn-key CFD model of the sort presented in this paper. Figure 18 shows the effect of simulation of a bad component due to an internal ma- nufacturing flaw(s), an internal short, etc. on a particular PC board. The component experiencing thermal runaway is immediately identified as the outlier in Figure 18, with a case temperature of 580 K (307˚C) while the interface of the sub-modules with the heat sink is 290 K (17˚C), thus a delta of 290˚C is manifested by this single com- ponent failure simulation.

5.6. Fan Outage Simulations

One very common lead to failure in large data racks and thermally controlled avionics electronics systems is fan failure. This leads to the thermal designer having to carry a redundant system, i.e. back-up fans, in case the primary fan cooling system experiences failure due to power drop

Page 9: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 152

Figure 15. Heat sink/cold plate temperatures.

Figure 16. Thermal fault simulation showing effect of contact resistance.

Figure 17. Effect of poor thermal contact resistance. out and/or fan motor burn-out. In order to understand the effects of fan failure, various CFD simulations were per- formed in by varying the air flow around a nominal value of 6 m/s (for a 80 mm dia. fan rated at 60 cfm). Figure 19 shows the results of the fan failure parametric trade

Figure 18. Thermal fault simulation of defective chip. study. Figure 19 is a plot of the system level maximum component/chip temperature versus fan air speed.

The trend depicted in Figure 19 is to be expected, i.e. as the fan speed approaches zero, the various components and PC cards within the sub-modules will witness a large

Open Access JECTC

Page 10: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL. 153

Figure 19. Maximum component/chip temperature versus cooling fan inlet air speed. temperature. The results of Figure 19 are in agreement with the trends of thermal impedance ΔT/Q versus Rey- nolds number identified in the study of [29] which fo- cused on the free stream cooling heat transfer cooling of micro-processor chips.

6. Conclusion

This paper has presented CFD simulations of heat and fluid flow behavior in a moderate sized package of elec- tronics undergoing very large power dissipations on the order of 1000 W/m2. A combination of heat transfer en-hancement thermal control strategies (high thermal con- ductivity materials, forced convection cooling using DC computer fans, and internal forced convection heat trans- fer using a pumped fluid loop cold plate/heat exchanger system) have been combined in order to simulate the ef- fectiveness of implementing COTS components to real- ize a thermal control solution. The results obtained herein are in qualitative agreement with previous studies involv- ing electronics cooling simulations [7,9,13,16]. Paramet- ric exercises involving air flow rate, water flow rate, ther- mal interface material, defective electronic components, and failed fans have been carried out.

REFERENCES [1] “Thermacore k-Core Data Sheet,” 2013.

http://www.thermacore.com/products/kcore.aspx

[2] D. D. L. Chung and Y. Takizawa, “Performance of Isotro- pic and Anisotropic Heat Spreaders,” Journal of Electro- nic Materials, Vol. 41, No. 9, 2012, pp. 2580-2587.

[3] Y. S. Yoon, H. Yang and H. Y. Kwak, “Enhancement of the Critical Heat Flux by Using Heat Spreader,” KSME International Journal, Vol. 17, No. 7, 2003, pp. 1063- 1072.

[4] K. J. Gray, “Effective Thermal Conductivity of a Diamond Coated Heat Spreader,” Diamond and Related Materials, Vol. 9, No. 2, 2000, pp. 201-204.

[5] P. Mohan, and P. Govindarajan, “Thermal Analysis of CPU with CCC and Copper Base Plate Heat Sinks Using

CFD,” Heat Transfer Asian Research, Vol. 40, No. 3, 2011, pp. 217-232.

[6] A. Part, R. Linton and D. Agonafer, “Coarse and Detailed CFD Modeling of a Finned Heat Sink,” IEEE Transac- tions on Components, Packaging and Manufacturing Te- chnology, Vol. 18, No. 3, 1995, pp. 517-520.

[7] P. Mohan and P. Govindarajan, “Experimental and CFD Analysis of Heat Sinks with Base Plate for CPU Cool- ing,” Journal of Mechanical Science and Technology, Vol. 25, No. 8, 2011, pp. 2003-2012.

[8] J. Yang, W. Wang and L. Huazhi, “2-Dimensional CFD Simulation and Correlation Development for Optimiza- tion of Fin Heatsinks in Electronic Cooling,” Journal of Thermal Science, Vol. 10, No. 4, 2001, pp. 363-371.

[9] E. Ozturk and I. Tari, “CFD Modeling of Forced Cooling of Computer Chassis,” Engineering Applications of Com- putational Fluid Mechanics, Vol. 1, No. 4, 2007, pp. 304- 313.

[10] V. Eveloy, J. Lohan, and P. Rodgers, “A Benchmark Stu- dy of Computational Fluid Dynamics Predictive Accura- cy for Component-Printed Circuit Board Heat Transfer,” IEEE Transactions on Components and Packaging Tech- nologies, Vol. 23, No. 3, 2000, pp. 568-578.

[11] I. Tari and Y. Fidan-Seza, “CFD Analyses of a Notebook Computer Thermal Management System and a Proposed Passive Cooling Alternative,” IEEE Transactions on Com- ponents and Packaging Technologies, Vol. 33, No. 2, 2010, pp. 443-452.

[12] A. Part and P. G. Tucker, “CFD Applied to Electronic Systems: A Review,” IEEE Transactions on Components, Packaging, and Manufacturing Technology, Vol. 20, No. 4, 1997, pp. 518-529.

[13] T. Y. Lee and M. Mahalingam, “Application of a CFD Tool for System Level Thermal Simulation,” IEEE Trans- actions on Components, Packaging and Manufacturing Technology—Part A, Vol. 17, No. 4, 1994, pp. 564-572.

[14] T. Y. Lee, B. Chambers and M. Mahalingam, “Applica- tion of a CFD Technology to Electronic Thermal Mana- gement,” IEEE Transactions on Components, Packaging and Manufacturing Technology—Part B,” Vol. 18, No. 3, 1995, pp. 511-520. http://dx.doi.org/10.1109/96.404110

[15] S. Aradag, U. Olgun, F. Aktuk and B. Baskbuyuk, “CFD Analysis of Cooling Electronic Equipment as an Under- graduate Project,” Wiley Periodicals Inc., 2009.

[16] J. Choi, Y. Kim, A. Sivasubramaniam, J. Srebric, Q. Wang and J. Lee, “A CFD Based Tool for Studying Tempera- ture in Rack Mounted Servers, IEEE Transactions on Com- puters,” Vol. 57, No. 8, 2008, pp. 1129-1142. http://dx.doi.org/10.1109/TC.2008.52

[17] A. Almodi, A. Thompson, N. Kapur, J. Summers, H. Thompson G. and Hannah, “Computational Fluid Dyna- mics Investigation of Liquid Rack Cooling in Data Cen- tres,” Applied Energy, Vol. 89, No. 1, 2012, pp. 150-155. http://dx.doi.org/10.1016/j.apenergy.2011.02.003

[18] J. Rambo and Y. Joshi, “Modeling of Data Center Air- flow and Heat Transfer: State of the Art and Future Trends,” Distributed Parallel Databases, Vol. 21, No. , 2007, pp. 193-225.

Open Access JECTC

Page 11: STAR CCM+ CFD Simulations of Enhanced Heat …...fects of heat transfer augmentation using high thermal conductivity materials in high power density electronics cooling scenarios

K. R. ANDERSON ET AL.

Open Access JECTC

154

http://dx.doi.org/10.1007/s10619-006-7007-3

[19] R. Boukhanouf and A. Haddad, “A CFD Analysis of an Electronics Cooling Enclosure for Application in Tele- communication Systems,” Applied Thermal Engineering, Vol. 30, No. 16, 2010, pp. 2426-2434. http://dx.doi.org/10.1016/j.applthermaleng.2010.06.012

[20] Z. Khatir, J. Paton, H. Thompson, N. Kapur, V. Toropov, M. Lawres and D. Kirk, “Computational Fluid Dynamics (CFD) Investigation of Air Flow and Temperature Distri- bution in a Small Scale Bread-Baking Oven,” Applied Energy, Vol. 89, No. 1, 2012, pp. 89-96. http://dx.doi.org/10.1016/j.apenergy.2011.02.002

[21] D. B. Flowers and K. R. Anderson, “Numerical Simula- tion of Conduction Heat Transfer in a System of Slowly Rotating Concentric Shells Separated by Small Annular Gap Distances,” Numerical Heat Transfer Part A, Vol. 46, No. 9, 2004, pp. 1-17.

[22] K. R. Anderson, “CFD Analysis of OPALS Sealed Enclo- sure Electronics Sub-System,” Proceedings from the Ther- mal & Fluids Workshop, NASA JPL, Pasadena, 2012.

[23] Y. A. Cengel, “Heat Transfer—A Practical Approach,” McGraw-Hill, New York, 2010.

[24] F. P. Incropera and D. P. Dewitt, “Heat Transfer,” Mc- Graw-Hill, New York, 1991.

[25] G. Ellison, “Thermal Computations for Electronics—Con- ductive, Radiative, and Convective Air Cooling,” CRC Press, Boca Raton, 2011.

[26] “Graftech Data Sheet,” 2013. www.graftech.com

[27] D. G. Gilmore, “Spacecraft Thermal Control,” Aerospace Press, El Segundo, 2002.

[28] “Chotherm Data Sheet,” 2013. www.chomerics.com

[29] M. A. Ismail, M. Z. Abdullah and M. A. Mujeebu, “A CFD Based Analysis on the Effect of Free Stream Cooling on the Performance of Micro Processor Heat Sinks,” Interna- tional Communications in Heat and Mass Transfer, Vol. 35, No. 6, 2008, pp. 771-778. http://dx.doi.org/10.1016/j.icheatmasstransfer.2008.02.012