statistical process control 1 chapter 3. lecture outline basics of statistical process control...

55
Statistical Process Control 1 Chapter 3

Upload: dana-bond

Post on 19-Dec-2015

242 views

Category:

Documents


4 download

TRANSCRIPT

3-1

Statistical Process Control

Chapter 3

Copyright 2011 John Wiley & Sons, Inc.

Lecture Outline

• Basics of Statistical Process Control• Control Charts• Control Charts for Attributes• Control Charts for Variables• Control Chart Patterns• SPC with Excel and OM Tools• Process Capability

3-2

Copyright 2011 John Wiley & Sons, Inc.

Statistical Process Control (SPC)

• Statistical Process Control• monitoring production process

to detect and prevent poor quality

• Sample• subset of items produced to

use for inspection

• Control Charts• process is within statistical

control limits

3-3

UCL

LCL

Copyright 2011 John Wiley & Sons, Inc.

Process Variability

• Random• inherent in a process• depends on equipment

and machinery, engineering, operator, and system of measurement

• natural occurrences

• Non-Random• special causes• identifiable and

correctable• include equipment out of

adjustment, defective materials, changes in parts or materials, broken machinery or equipment, operator fatigue or poor work methods, or errors due to lack of training

3-4

Copyright 2011 John Wiley & Sons, Inc.

SPC in Quality Management

• SPC uses• Is the process in control?• Identify problems in order to make

improvements• Contribute to the TQM goal of continuous

improvement

3-5

Copyright 2011 John Wiley & Sons, Inc.

Quality Measures:Attributes and Variables

• Attribute• A characteristic which is evaluated with a

discrete response• good/bad; yes/no; correct/incorrect

• Variable measure• A characteristic that is continuous and can be

measured• Weight, length, voltage, volume

3-6

Copyright 2011 John Wiley & Sons, Inc.

SPC Applied to Services

• Nature of defects is different in services• Service defect is a failure to meet customer

requirements• Monitor time and customer satisfaction

3-7

Copyright 2011 John Wiley & Sons, Inc.

SPC Applied to Services

• Hospitals• timeliness & quickness of care, staff responses to requests,

accuracy of lab tests, cleanliness, courtesy, accuracy of paperwork, speed of admittance & checkouts

• Grocery stores• waiting time to check out, frequency of out-of-stock items, quality

of food items, cleanliness, customer complaints, checkout register errors

• Airlines• flight delays, lost luggage & luggage handling, waiting time at

ticket counters & check-in, agent & flight attendant courtesy, accurate flight information, cabin cleanliness & maintenance

3-8

Copyright 2011 John Wiley & Sons, Inc.

SPC Applied to Services

• Fast-food restaurants• waiting time for service, customer complaints, cleanliness, food

quality, order accuracy, employee courtesy

• Catalogue-order companies• order accuracy, operator knowledge & courtesy, packaging,

delivery time, phone order waiting time

• Insurance companies• billing accuracy, timeliness of claims processing, agent

availability & response time

3-9

Copyright 2011 John Wiley & Sons, Inc.

Where to Use Control Charts

• Process • Has a tendency to go out of control

• Is particularly harmful and costly if it goes out of control

• Examples• At beginning of process because of waste to begin

production process with bad supplies• Before a costly or irreversible point, after which product is

difficult to rework or correct• Before and after assembly or painting operations that

might cover defects• Before the outgoing final product or service is delivered

3-10

Copyright 2011 John Wiley & Sons, Inc.

Control Charts

• A graph that monitors process quality• Control limits

• upper and lower bands of a control chart

• Attributes chart• p-chart• c-chart

• Variables chart• mean (x bar – chart)• range (R-chart)

3-11

Copyright 2011 John Wiley & Sons, Inc.

Process Control Chart

3-12

1 2 3 4 5 6 7 8 9 10Sample number

Uppercontrol

limit

Processaverage

Lowercontrol

limit

Out of control

Copyright 2011 John Wiley & Sons, Inc.

Normal Distribution

• Probabilities for Z= 2.00 and Z = 3.00

3-13

=0 1 2 3-1-2-3

95%

99.74%

Copyright 2011 John Wiley & Sons, Inc.

A Process Is in Control If …

3-14

1. … no sample points outside limits

2. … most points near process average

3. … about equal number of points above and below centerline

4. … points appear randomly distributed

Copyright 2011 John Wiley & Sons, Inc.

Control Charts for Attributes

• p-chart• uses portion defective in a sample

• c-chart• uses number of defects (non-conformities) in a

sample

3-15

Copyright 2011 John Wiley & Sons, Inc.

p-Chart

3-16

UCL = p + zp

LCL = p - zp

z = number of standard deviations from process average

p = sample proportion defective; estimates process mean

p = standard deviation of sample proportionp =

p(1 - p)

n

Copyright 2011 John Wiley & Sons, Inc.

Construction of p-Chart

3-17

20 samples of 100 pairs of jeans

NUMBER OF PROPORTIONSAMPLE # DEFECTIVES DEFECTIVE

1 6 .06

2 0 .00

3 4 .04

: : :

: : :

20 18 .18

200

Copyright 2011 John Wiley & Sons, Inc.

Construction of p-Chart

3-18

UCL = p + z = 0.10 + 3p(1 - p)

n

0.10(1 - 0.10)

100

UCL = 0.190

LCL = 0.010

LCL = p - z = 0.10 - 3p(1 - p)

n

0.10(1 - 0.10)

100

= 200 / 20(100) = 0.10total defectives

total sample observationsp =

Copyright 2011 John Wiley & Sons, Inc.

Construction of p-Chart

3-19

0.02

0.04

0.06

0.08

0.10

0.12

0.14

0.16

0.18

0.20

Pro

por

tion

defe

ctiv

e

Sample number2 4 6 8 10 12 14 16 18 20

UCL = 0.190

LCL = 0.010

p = 0.10

Copyright 2011 John Wiley & Sons, Inc.

p-Chart in Excel

3-20

Click on “Insert” then “Charts”

to construct control chart

I4 + 3*SQRT(I4*(1-I4)/100)

I4 - 3*SQRT(I4*(1-I4)/100)

Column values copiedfrom I5 and I6

Copyright 2011 John Wiley & Sons, Inc.

c-Chart

3-21

UCL = c + zc

LCL = c - zc

where

c = number of defects per sample

c = c

Copyright 2011 John Wiley & Sons, Inc.

c-Chart

3-22

Number of defects in 15 sample rooms

1 122 83 16

: :: :15 15 190

SAMPLE

c = = 12.6719015

UCL = c + zc

= 12.67 + 3 12.67= 23.35

LCL = c - zc

= 12.67 - 3 12.67= 1.99

NUMBER OF

DEFECTS

Copyright 2011 John Wiley & Sons, Inc.

c-Chart

3-23

3

6

9

12

15

18

21

24

Num

ber

of

defe

cts

Sample number

2 4 6 8 10 12 14 16

UCL = 23.35

LCL = 1.99

c = 12.67

Copyright 2011 John Wiley & Sons, Inc.

Control Charts for Variables

3-24

Range chart ( R-Chart ) Plot sample range (variability)

Mean chart ( x -Chart ) Plot sample averages

3-25

x-bar Chart: Known

UCL = x + z x LCL = x - z x

-

-

==

Where

s = process standard deviations

x = standard deviation of sample means =/k = number of samples (subgroups)n = sample size (number of observations)

x1 + x2 + ... + xk

kX = =

- - -

n

Copyright 2011 John Wiley & Sons, Inc.

Copyright 2011 John Wiley & Sons, Inc.

Observations(Slip-Ring Diameter, cm) n

Sample k 1 2 3 4 5 -

x-bar Chart Example: Known

3-26

x

We know σ = .08

x-bar Chart Example: Known

Copyright 2011 John Wiley & Sons, Inc. 3-27

= 5.01 - 3(.08 / )10

= 4.93

_____10

50.09 = 5.01X =

=

LCL = x - z x = -UCL = x + z x

= -= 5.01 + 3(.08 / )10

= 5.09

Copyright 2011 John Wiley & Sons, Inc.

x-bar Chart Example: Unknown

3-28

_UCL = x + A2R LCL = x - A2R

= =_

where

x = average of the sample means

R = average range value

=_

Copyright 2011 John Wiley & Sons, Inc. 3-29

Control Chart Factors

n A2 D3 D42 1.880 0.000 3.2673 1.023 0.000 2.5754 0.729 0.000 2.2825 0.577 0.000 2.1146 0.483 0.000 2.0047 0.419 0.076 1.9248 0.373 0.136 1.8649 0.337 0.184 1.81610 0.308 0.223 1.77711 0.285 0.256 1.74412 0.266 0.283 1.71713 0.249 0.307 1.69314 0.235 0.328 1.67215 0.223 0.347 1.65316 0.212 0.363 1.63717 0.203 0.378 1.62218 0.194 0.391 1.60919 0.187 0.404 1.59620 0.180 0.415 1.58521 0.173 0.425 1.57522 0.167 0.435 1.56523 0.162 0.443 1.55724 0.157 0.452 1.54825 0.153 0.459 1.541

Factors for R-chartSample

Size Factor for X-chart

Copyright 2011 John Wiley & Sons, Inc.

x-bar Chart Example: Unknown

3-30

OBSERVATIONS (SLIP- RING DIAMETER, CM)

SAMPLE k 1 2 3 4 5 x R

1 5.02 5.01 4.94 4.99 4.96 4.98 0.082 5.01 5.03 5.07 4.95 4.96 5.00 0.123 4.99 5.00 4.93 4.92 4.99 4.97 0.084 5.03 4.91 5.01 4.98 4.89 4.96 0.145 4.95 4.92 5.03 5.05 5.01 4.99 0.136 4.97 5.06 5.06 4.96 5.03 5.01 0.107 5.05 5.01 5.10 4.96 4.99 5.02 0.148 5.09 5.10 5.00 4.99 5.08 5.05 0.119 5.14 5.10 4.99 5.08 5.09 5.08 0.15

10 5.01 4.98 5.08 5.07 4.99 5.03 0.10

50.09 1.15Totals

Copyright 2011 John Wiley & Sons, Inc.

x-bar Chart Example: Unknown

3-31

∑ Rk

1.1510R = = = 0.115

_ ____ ____

_UCL = x + A2R

=

= 50.0910

_____x = = = 5.01 cmåx

k___

= 5.01 + (0.58)(0.115) = 5.08

_LCL = x - A2R

== 5.01 - (0.58)(0.115) = 4.94

Copyright 2011 John Wiley & Sons, Inc.

x- bar Chart

Example

3-32

UCL = 5.08

LCL = 4.94

Mea

n

Sample number

|1

|2

|3

|4

|5

|6

|7

|8

|9

|10

5.10 –

5.08 –

5.06 –

5.04 –

5.02 –

5.00 –

4.98 –

4.96 –

4.94 –

4.92 –

x = 5.01=

Copyright 2011 John Wiley & Sons, Inc.

R- Chart

3-33

UCL = D4R LCL = D3R

R = åRk

WhereR = range of each samplek = number of samples (sub groups)

Copyright 2011 John Wiley & Sons, Inc.

R-Chart Example

3-34

OBSERVATIONS (SLIP- RING DIAMETER, CM)

SAMPLE k 1 2 3 4 5 x R

1 5.02 5.01 4.94 4.99 4.96 4.98 0.082 5.01 5.03 5.07 4.95 4.96 5.00 0.123 4.99 5.00 4.93 4.92 4.99 4.97 0.084 5.03 4.91 5.01 4.98 4.89 4.96 0.145 4.95 4.92 5.03 5.05 5.01 4.99 0.136 4.97 5.06 5.06 4.96 5.03 5.01 0.107 5.05 5.01 5.10 4.96 4.99 5.02 0.148 5.09 5.10 5.00 4.99 5.08 5.05 0.119 5.14 5.10 4.99 5.08 5.09 5.08 0.15

10 5.01 4.98 5.08 5.07 4.99 5.03 0.10

50.09 1.15Totals

Copyright 2011 John Wiley & Sons, Inc.

R-Chart Example

3-35

Retrieve chart factors D3 and D4

UCL = D4R = 2.11(0.115) = 0.243

LCL = D3R = 0(0.115) = 0_

_

Copyright 2011 John Wiley & Sons, Inc.

R-Chart Example

3-36

UCL = 0.243

LCL = 0

Ra

nge

Sample number

R = 0.115

|1

|2

|3

|4

|5

|6

|7

|8

|9

|10

0.28 –

0.24 –

0.20 –

0.16 –

0.12 –

0.08 –

0.04 –

0 –

Copyright 2011 John Wiley & Sons, Inc.

X-bar and R charts – Excel & OM Tools

3-37

Copyright 2011 John Wiley & Sons, Inc.

Using x- bar and R-Charts Together

• Process average and process variability must be in control

• Samples can have very narrow ranges, but sample averages might be beyond control limits

• Or, sample averages may be in control, but ranges might be out of control

• An R-chart might show a distinct downward trend, suggesting some nonrandom cause is reducing variation

3-38

Copyright 2011 John Wiley & Sons, Inc.

Control Chart Patterns

• Run• sequence of sample values that display same

characteristic

• Pattern test• determines if observations within limits of a control

chart display a nonrandom pattern

3-39

Copyright 2011 John Wiley & Sons, Inc.

Control Chart Patterns

• To identify a pattern look for:• 8 consecutive points on one side of the center line• 8 consecutive points up or down• 14 points alternating up or down• 2 out of 3 consecutive points in zone A (on one side of

center line)• 4 out of 5 consecutive points in zone A or B (on one

side of center line)

3-40

Copyright 2011 John Wiley & Sons, Inc.

Control Chart Patterns

3-41

UCL

LCL

Sample observationsconsistently above thecenter line

LCL

UCL

Sample observationsconsistently below thecenter line

Copyright 2011 John Wiley & Sons, Inc.

Control Chart Patterns

3-42

LCL

UCL

Sample observationsconsistently increasing

UCL

LCL

Sample observationsconsistently decreasing

Zones for Pattern Tests

3-43

UCL

LCL

Zone A

Zone B

Zone C

Zone C

Zone B

Zone A

Process average

3 sigma = x + A2R=

3 sigma = x - A2R=

2 sigma = x + (A2R)= 23

2 sigma = x - (A2R)= 23

1 sigma = x + (A2R)= 13

1 sigma = x - (A2R)= 13

x=

Sample number

|1

|2

|3

|4

|5

|6

|7

|8

|9

|10

|11

|12

|13

Copyright 2011 John Wiley & Sons, Inc.

Copyright 2011 John Wiley & Sons, Inc.

Performing a Pattern Test

3-44

1 4.98 B — B

2 5.00 B U C

3 4.95 B D A

4 4.96 B D A

5 4.99 B U C

6 5.01 — U C

7 5.02 A U C

8 5.05 A U B

9 5.08 A U A

10 5.03 A D B

SAMPLE x ABOVE/BELOW UP/DOWN ZONE

Copyright 2011 John Wiley & Sons, Inc.

Sample Size Determination

• Attribute charts require larger sample sizes• 50 to 100 parts in a sample

• Variable charts require smaller samples• 2 to 10 parts in a sample

3-45

Copyright 2011 John Wiley & Sons, Inc.

Process Capability

• Compare natural variability to design variability • Natural variability

• What we measure with control charts• Process mean = 8.80 oz, Std dev. = 0.12 oz

• Tolerances• Design specifications reflecting product

requirements• Net weight = 9.0 oz 0.5 oz • Tolerances are 0.5 oz

3-46

Copyright 2011 John Wiley & Sons, Inc.

Process Capability

3-47

(b) Design specifications and natural variation the same; process is capable of meeting specifications most of the time.

Design Specifications

Process

(a) Natural variation exceeds design specifications; process is not capable of meeting specifications all the time.

Design Specifications

Process

Copyright 2011 John Wiley & Sons, Inc.

Process Capability

3-48

(c) Design specifications greater than natural variation; process is capable of always conforming to specifications.

Design Specifications

Process

(d) Specifications greater than natural variation, but process off center; capable but some output will not meet upper specification.

Design Specifications

Process

Copyright 2011 John Wiley & Sons, Inc.

Process Capability Ratio

3-49

Cp =tolerance range

process range

upper spec limit - lower spec limit

6=

Copyright 2011 John Wiley & Sons, Inc.

Computing Cp

3-50

Net weight specification = 9.0 oz 0.5 ozProcess mean = 8.80 ozProcess standard deviation = 0.12 oz

Cp =

= = 1.39

upper specification limit - lower specification limit

6

9.5 - 8.5

6(0.12)

Copyright 2011 John Wiley & Sons, Inc.

Process Capability Index

3-51

Cpk = minimum

x - lower specification limit

3

=

upper specification limit - x

3

=

,

Copyright 2011 John Wiley & Sons, Inc.

Computing Cpk

3-52

Net weight specification = 9.0 oz 0.5 ozProcess mean = 8.80 ozProcess standard deviation = 0.12 oz

Cpk = minimum

= minimum , = 0.83

x - lower specification limit

3

=

upper specification limit - x

3

=

,

8.80 - 8.50

3(0.12)

9.50 - 8.80

3(0.12)

Copyright 2011 John Wiley & Sons, Inc.

Process Capability With Excel

3-53

=(D6-D7)/(6*D8)

See formula bar

Copyright 2011 John Wiley & Sons, Inc.

Process Capability With OM Tools

3-54

Copyright 2011 John Wiley & Sons, Inc. 3-55

Copyright 2011 John Wiley & Sons, Inc.All rights reserved. Reproduction or translation of this work beyond that permitted in section 117 of the 1976 United States Copyright Act without express permission of the copyright owner is unlawful. Request for further information should be addressed to the Permission Department, John Wiley & Sons, Inc. The purchaser may make back-up copies for his/her own use only and not for distribution or resale. The Publisher assumes no responsibility for errors, omissions, or damages caused by the use of these programs or from the use of the information herein.