sterilization physical methods
DESCRIPTION
Sterilization physical methodsTRANSCRIPT
![Page 1: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/1.jpg)
STERILIZATION BY
PHYSICAL METHODSDr.T.V.Rao MD
04/11/2023 Dr.T.V.Rao MD 1
![Page 2: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/2.jpg)
Why we need Sterilization• Microorganisms capable of causing
infection are constantly present in the external environment and on the human body.
• Microorganisms are responsible for contamination and infection.
• The aim of sterilisation is to remove or destroy them from materials or from surfaces.04/11/2023 Dr.T.V.Rao MD 2
![Page 3: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/3.jpg)
How can microorganisms be killed?
1 Denaturation of proteins (e.g. wet heat, ethylene oxide)
2 Oxidation (e.g. dry heat, hydrogen peroxide)3 Filtration4 Interruption of DNA synthesis/repair (e.g.
radiation)5 Interference with protein synthesis (e.g. bleach)6 Disruption of cell membranes (e.g. phenols)
04/11/2023 Dr.T.V.Rao MD 3
![Page 4: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/4.jpg)
Classification There are two types of sterilization: physical and chemical.
1. Physical sterilization includes:
heat radiation filtration
2. Chemical sterilization includes:
Alcohols Aldehydes Phenolics Oxidizing agents Quaternary ammonium co
mpounds
ethylene oxide gas Others
04/11/2023 Dr.T.V.Rao MD 4
![Page 5: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/5.jpg)
Definitions: Sterilisation :
– It is a process by which an article, surface or medium is made free of all microorganisms either in vegetative or spore form.
Disinfection :– Destruction of all pathogens or organisms capable of
producing infections but not necessarily spores.– All organisms may not be killed but the number is
reduced to a level that is no longer harmful to health.
04/11/2023 Dr.T.V.Rao MD 5
![Page 6: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/6.jpg)
Antiseptics :
Antiseptics :– Chemical disinfectants which can safely
applied to living tissues and are used to prevent infection by inhibiting the growth of microorganisms.
Asepsis :– Technique by which the occurrence of
infection into an uninfected tissue is prevented.
04/11/2023 Dr.T.V.Rao MD 6
![Page 7: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/7.jpg)
Factors that influence efficacy of disinfection/sterilization
1 Contact time2 Physico-chemical environment (e.g. pH)3 Presence of organic material4 Temperature5 Type of microorganism6 Number of microorganisms7 Material composition
04/11/2023 Dr.T.V.Rao MD 7
![Page 8: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/8.jpg)
Uses of sterilisation:1. Sterilisation of materials,
instruments used in surgical and diagnostic procedures.
2. Sterilisation of Media and reagents used in the microbiology laboratory.
3. Food and drug manufacturing to ensure safety from contaminating organisms.
04/11/2023 Dr.T.V.Rao MD 8
![Page 9: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/9.jpg)
Understanding the Terminology• a suffix indicating that the antimicrobial agent will kill or • destroy a certain group of microorganism • suffix “cide” – meaning to kill• viricide – destroys virus• fungicide – destroys fungi• bactericide – destroys bacteria•
• Suffix “static/stasis” – meaning to stand still • a suffix indicating that the agent will prevent the growth or • multiplication of the type of organism but are not killed outright •
• bacteriostatic - prevents the growth of bacteria• fungi static – prevents the growth of fungi
04/11/2023 Dr.T.V.Rao MD 9
![Page 10: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/10.jpg)
Relative Resistance of Microbial Forms
Highest resistance Moderate resistance Least resistance
bacterial endospore (Bacillus & Clostridium)
protozoan cystsome fungal sporessome naked virusvegetative bacteria that have higher resistance ( M. tuberculosis, S.aureus, Pseudomonas)
most bacterial vegetative cellsordinary fungal spores & hypaeenveloped virusYeastsTrophozoites
04/11/2023 Dr.T.V.Rao MD 10
![Page 11: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/11.jpg)
04/11/2023 Dr.T.V.Rao MD 11
What to sterilize?• It is mandatory to sterilize :
– all instruments that penetrate soft tissues and bone.– Instruments that are not intended to penetrate the
tissues, but that may come into contact with oral tissues.
• If the sterilization procedure may damage the instruments, then, sterilization can be replaced by Disinfection procedure
![Page 12: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/12.jpg)
Ideal sterilization/disinfection process
• Highly efficacious• Fast• Good penetrability• Compatible with all materials• Non-toxic• Effective despite presence of organic material• Difficult to make significant mistakes in process• Easily monitored
04/11/2023 Dr.T.V.Rao MD 12
![Page 13: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/13.jpg)
Control of Microbial Growth:Rate of Microbial Death
When bacterial populations are heated or treated antimicrobial chemicals, they usually die at a
constant rate.
04/11/2023 Dr.T.V.Rao MD 13
![Page 14: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/14.jpg)
Figure 9.1 A plot of microbial death rate
90% die
1 min
90% die
1 min
Constant percentageof the extant populationis killed each minute
Time (min)
Nu
mb
er
of
livin
g m
icro
bes
04/11/2023 Dr.T.V.Rao MD 14
![Page 15: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/15.jpg)
Methods
1.Physical methods
2.Chemical methods
04/11/2023 Dr.T.V.Rao MD 15
![Page 16: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/16.jpg)
Physical methods:• Physical
methods:1.Sunlight 2.Heat
1.Dry heat2.Moist heat
3.Filtration 4.Radiation
04/11/2023 Dr.T.V.Rao MD 16
![Page 17: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/17.jpg)
Chemical methods• Chemical methods:
1. Alcohols2. Aldehydes3. Phenols4. Halogens5. Oxidizing agents6. Salts7. Surface active agents8. Dyes9. Vapor phase disinfectants
04/11/2023 Dr.T.V.Rao MD 17
![Page 18: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/18.jpg)
Physical Methods
04/11/2023 Dr.T.V.Rao MD 18
![Page 19: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/19.jpg)
Materials Method
1 Inoculating wires and loops Red heat
2 Glass ware- syringes, petridishes, testtubes, flasks etc.
Hot –air oven
3 Disposable syringes, and other disposable items
Gamma radiation
4 Culture media Autoclaving
5 Culture media containing serum and egg Tyndallisation
6 Toxin , serum, sugar, and antibiotic solutions
Filtration
7 Cystoscope and endoscope Glutaraldehyde
8 Infected soiled dressings Incineration
9 Skin Iodine, alcohol
10 Milk Pasteurisation
How to Sterilize
04/11/2023 Dr.T.V.Rao MD 19
![Page 20: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/20.jpg)
Physical Methods of Microbial ControlDry Heat:
Direct Flaming: Used to sterilize inoculating loops and needles. Heat metal until it has a red glow.
Incineration: Effective way to sterilize disposable items (paper cups, dressings) and biological waste.
Hot Air Sterilization: Place objects in an oven. Require 2 hours at 170oC for sterilization. Dry heat is transfers heat less effectively to a cool body, than moist heat.
04/11/2023 Dr.T.V.Rao MD 20
![Page 21: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/21.jpg)
Physical Methods of Microbial Control
• Heat-Related Methods– Moist heat
• Pasteurization– Used for milk, ice cream, yogurt, and fruit juices– Not sterilization
» Heat-tolerant microbes survive– Pasteurization of milk
» Batch method» Flash pasteurization» Ultrahigh-temperature pasteurization
© 2012 Pearson Education Inc.04/11/2023 Dr.T.V.Rao MD 21
![Page 22: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/22.jpg)
Physical Methods of Microbial Control
Moist Heat (Continued): Pasteurization: Developed by Louis Pasteur to
prevent the spoilage of beverages. Used to reduce microbes responsible for spoilage of beer, milk, wine, juices, etc. Classic Method of Pasteurization: Milk was
exposed to 65oC for 30 minutes. High Temperature Short Time Pasteurization
(HTST): Used today. Milk is exposed to 72oC for 15 seconds.
04/11/2023 Dr.T.V.Rao MD 22
![Page 23: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/23.jpg)
Inspissation:
1. Inspissation: Heating at 80-85°C for half an hour daily on
three consecutive days Serum or egg media are sterilised
2. Vaccine bath: Heating at 60°C for an hour daily in vaccine
bath for several successive days. Serum or body fluids can be sterilised by
heating at 56°C for an hour daily for several successive days.
04/11/2023 Dr.T.V.Rao MD 23
![Page 24: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/24.jpg)
Sun light:
• Sun light:– Active germicidal
effect due to its content of ultraviolet rays .
– Natural method of sterilisation of water in tanks, rivers and lakes.
04/11/2023 Dr.T.V.Rao MD 24
![Page 25: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/25.jpg)
Heat :
• Factors influencing:• Nature of heat• Temperature and duration• Characteristic of organism and
spores• Type of material
04/11/2023 Dr.T.V.Rao MD 25
![Page 26: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/26.jpg)
Heat effectively kills Majority of Microbes
Heat :• Principle:
– Dry heat kills the organism by• denaturation of the bacterial proteins, • oxidative damage• toxic effect of elevated levels of
electrolytes.
04/11/2023 Dr.T.V.Rao MD 26
![Page 27: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/27.jpg)
Heat :• Dry heat:
1.Red heat2.Flaming 3.Incineration 4.Hot air oven
04/11/2023 Dr.T.V.Rao MD 27
![Page 28: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/28.jpg)
04/11/2023 Dr.T.V.Rao MD 28
Dry-Heat Sterilization• Involves heating at atmospheric pressure
and often use a fan to obtain uniform temperature by circulation.
• Heat at 180º for half hour , 170º for 1 hr., or 160º C for 2 hrs.
• Times are the periods during which object is maintained at the respective temp.
![Page 29: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/29.jpg)
Dry heat:• Dry heat:
1. Red heat: Materials are held in the flame of a bunsen burner till they become red hot.» Inoculating
wires or loops» Tips of forceps» Needles
04/11/2023 Dr.T.V.Rao MD 29
![Page 30: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/30.jpg)
Dry heat:
• Dry heat:2. Flaming: Materials are
passed through the flame of a bunsen burner without allowing them to become red hot.
» Glass slides» scalpels» Mouths of culture
tubes
04/11/2023 Dr.T.V.Rao MD 30
![Page 31: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/31.jpg)
Incineration: • Materials are
reduced to ashes by burning.
• Instrument used was incinerator.
• Soiled dressings• Animal carcasses• Bedding • Pathological material
04/11/2023 Dr.T.V.Rao MD 31
![Page 32: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/32.jpg)
04/11/2023 Dr.T.V.Rao MD 32
Dry-Heat Sterilization Disadvantages
• Disadvantages:–Less reliable than autoclaving–Large temp difference may arise within
device.–sharp instruments get dulled–Many materials do not tolerate dry heat
![Page 33: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/33.jpg)
Hot air oven: • Most widely used method• Electrically heated and fitted with a fan to
even distribution of air in the chamber.• Fitted with a thermostat that maintains
the chamber air at a chosen temperature.• Temperature and time:
» 160 C for 2 hours.» 170 C for 1 hour» 180 C for 30 minutes.
04/11/2023 Dr.T.V.Rao MD 33
![Page 34: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/34.jpg)
Uses of Hot Air Oven
– Sterilisation of 1.Glassware like glass syringes, petri
dishes, pipettes and test tubes. 2.Surgical instruments like scalpels,
scissors, forceps etc.3.Chemicals like liquid paraffin, fats
etc.
04/11/2023 Dr.T.V.Rao MD 34
![Page 35: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/35.jpg)
– Precautions :1. Should not be overloaded 2. Arranged in a manner which allows free
circulation of air3. Material to be sterilized should be perfectly dry.4. Test tubes, flasks etc. should be fitted with
cotton plugs.5. petridishes and pipetts should be wrapped in
paper.6. Rubber materials and inflammable materials
should not be kept inside.7. The oven must be allowed to cool for two hours
before opening, since glass ware may crack by sudden cooling.04/11/2023 Dr.T.V.Rao MD 35
![Page 36: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/36.jpg)
Sterilisation controls :
• Sterilisation controls
1.Spores of Bacillus subtilis subsp. niger
2. Thermocouples
3.Browne’s tube
04/11/2023 Dr.T.V.Rao MD 36
![Page 37: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/37.jpg)
Sterilizing below100°C
1. temperature below 100° Pasteurization of milk
1.Inspissation2.Vaccine bath
04/11/2023 Dr.T.V.Rao MD 37
![Page 38: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/38.jpg)
Principle of Pasteurization
04/11/2023 Dr.T.V.Rao MD 38
![Page 39: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/39.jpg)
A temperature at 100°C
II. A temperature at 100°C
1. Boiling 2. Tyndallisation
3. Steam sterilisation
04/11/2023 Dr.T.V.Rao MD 39
![Page 40: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/40.jpg)
Boiling :1 Boiling for 10 – 30 minutes may kill most of vegetative forms but spores with stand boiling.
2. Tyndallisation : Steam at 100C for 20 minutes on three
successive days Used for egg , serum and sugar containing
media.3. Steam sterilizer :
Steam at 100°C for 90 minutes. Used for media which are decomposed at high
temperature.04/11/2023 Dr.T.V.Rao MD 40
![Page 41: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/41.jpg)
Temperatures above 100°CIII. A temperature
above 100°CAutoclave : -Steam above
100°C has a better killing power than dry heat.
-Bacteria are more susceptible to moist heat.
04/11/2023 Dr.T.V.Rao MD 41
![Page 42: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/42.jpg)
Components of autoclave:
• Components of autoclave:– Consists of vertical or horizontal cylinder of
gunmetal or stainless steel.– Lid is fastened by screw clamps and
rendered air tight by an asbestos washer.– Lid bears a discharge tap for air and steam,
a pressure gauge and a safety valve.
04/11/2023 Dr.T.V.Rao MD 42
![Page 43: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/43.jpg)
Figure 9.6 Autoclave-overview
04/11/2023 Dr.T.V.Rao MD 43
![Page 44: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/44.jpg)
Autoclave: Closed Chamber with High Temperature and Pressure
![Page 45: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/45.jpg)
04/11/2023 Dr.T.V.Rao MD 45
![Page 46: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/46.jpg)
Sterilisation conditions• Sterilisation conditions:
–Temperature – 121 °C–Chamber pressure -15 lb per square
inch.–Holding time – 15 minutes–Others :
• 126°C for 10 minutes• 133°C for 3 minutes
04/11/2023 Dr.T.V.Rao MD 46
![Page 47: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/47.jpg)
04/11/2023 Dr.T.V.Rao MD 47
Sterilization – instrument Packing
• Often instruments are packed for sterilization to be stored and handled without being contaminated.
• Packing depend on the intended shelf life after sterilization.
• The available packing options are:– Textile has shelf life of 1 month– Paper has shelf life of 1 – 6 months– Nylon, glass, and metal have shelf life of 1 year if
tightly closed
![Page 48: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/48.jpg)
Uses of Autoclaves:
• Uses :1. Useful for
materials which can not withstand high temp.
2. To sterilize culture media, rubber material, gowns, dressings, gloves etc.
04/11/2023 Dr.T.V.Rao MD 48
![Page 49: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/49.jpg)
Sterilisation controls:
• Sterilisation controls:1. Thermocouples2. Bacterial spores-
Bacillus stearothermophilus
3. Browne’s tube4. Autoclave tapes
04/11/2023 Dr.T.V.Rao MD 49
![Page 50: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/50.jpg)
Cap that allowssteam to penetrate
Flexible plasticvial
Crushable glassampule
Nutrient mediumcontaining pHcolor indicator
Endospore strip
Incubation
After autoclaving, flexiblevial is squeezed to breakampule and releasemedium onto spore strip.
Yellow mediummeans spores areviable; autoclavedobjects are notsterile.
Red mediummeans spores werekilled; autoclavedobjects aresterile.
Sterility Controls
04/11/2023 Dr.T.V.Rao MD 50
![Page 51: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/51.jpg)
Filtration:• . Filtration:
• Useful for substances which get damaged by heat.
• To sterilize sera, sugars and antibiotic solutions.
• To obtain bacteria free filtrates of clinical samples.
• Purification of water.04/11/2023 Dr.T.V.Rao MD 51
![Page 52: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/52.jpg)
FILTRATION STERILIZATION This method is commonly used for
sensitive pharmaceuticals and protein solutions in biological research.
A filter with pore size 0.2 µm will effectively remove bacteria.
If viruses must also be removed, a much smaller pore size around 20 nm is needed.
Prions are not removed by filtration. The filtration equipment and the
filters themselves may be purchased as presterilized disposable units in sealed packaging,
or must be sterilized by the user, generally by autoclaving at a temperature that does not damage the fragile filter membranes.
To ensure sterility, the filtration system must be tested to ensure that the membranes have not been punctured prior to or during use.
To ensure the best results, pharmaceutical sterile filtration is performed in a room with highly filtered air (HEPA filtration) or in a laminar flow cabinet or "flowbox", a device which produces a laminar stream of HEPA filtered air.
HEPA filters are critical in the prevention of the spread of airborne bacterial and viral organisms and, therefore, infection. Typically, medical-use HEPA filtration systems also incorporate high-energy ultra-violet light units to kill off the live bacteria and viruses trapped by the filter media.
![Page 53: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/53.jpg)
Several Types of Filters• Types of filters:
1. Candle filters2. Asbestos disc filters3. Sintered glass filters4. Membrane filters5. Air filters6. Syringe filters
04/11/2023 Dr.T.V.Rao MD 53
![Page 54: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/54.jpg)
Filtration Sterilize solutions
that may be damaged or denatured by high temperatures or chemical agents.
04/11/2023 Dr.T.V.Rao MD 54
![Page 55: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/55.jpg)
The pore size for filtering bacteria, yeasts, and fungi is in the range of 0.22-0.45 μm (filtration membranes are most popular for this purpose).
The filtering Depends on Pore Size
04/11/2023 Dr.T.V.Rao MD 55
![Page 56: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/56.jpg)
Candle filters
04/11/2023 Dr.T.V.Rao MD 56
![Page 57: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/57.jpg)
The roles of HEPA filters in biological flow safety cabinets
Exhaust HEPAfilter
Blower
Supply HEPAfilter
Light
High-velocityair barrier
Safety glassviewscreen
04/11/2023 Dr.T.V.Rao MD 57
![Page 58: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/58.jpg)
Radiations :• Radiations :
•Ionizing radiations
•Non - Ionizing radiations
04/11/2023 Dr.T.V.Rao MD 58
![Page 59: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/59.jpg)
Ionising radiations:
– Ionizing radiations:1. X rays2. Gamma rays3. Cosmic rays
• Gamma radiation are commercially used for sterilisation of disposable items. (cold sterilisation)
04/11/2023 Dr.T.V.Rao MD 59
![Page 60: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/60.jpg)
Physical Methods of Microbial Control
• Radiation– Nonionizing radiation
• Wavelengths greater than 1 nm• Excites electrons, causing them to make new covalent
bonds– Affects 3-D structure of proteins and nucleic acids
• UV light causes pyrimidine dimers in DNA• UV light does not penetrate well• Suitable for disinfecting air, transparent fluids, and
surfaces of objects
© 2012 Pearson Education Inc.04/11/2023 Dr.T.V.Rao MD 60
![Page 61: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/61.jpg)
Forms of Radiation
04/11/2023 Dr.T.V.Rao MD 61
![Page 62: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/62.jpg)
Physical Methods of Microbial Control:
Radiation: Three types of radiation kill microbes: Ultraviolet light (Nonionizing Radiation): Wavelength is longer than 1 nanometer. Damages DNA by producing thymine dimers, which cause mutations. Used to disinfect operating rooms, nurseries, cafeterias. Disadvantages: Damages skin, eyes. Doesn’t penetrate paper, glass, and cloth.
04/11/2023 Dr.T.V.Rao MD 62
![Page 63: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/63.jpg)
Non-Ionising radiation:
1. Infra red rays2. Ultraviolet (UV) rays
– Infra red is used for rapid mass sterilisation of syringes and catheters.
– Ultraviolet radiation is used for disinfecting enclosed areas such as bacterial laboratory, inoculation hood, laminar flow and operation theatres.
04/11/2023 Dr.T.V.Rao MD 63
![Page 64: Sterilization physical methods](https://reader033.vdocument.in/reader033/viewer/2022061613/554b2526b4c905d3088b4634/html5/thumbnails/64.jpg)
Programme Created by Dr.T.V.Rao MD for Medical and Paramedical Students