    Sterner Lighting Systems

  • 8/2/2019 Sterner Area & Roadway Manchester Brochure 1974

    2/6

  • 8/2/2019 Sterner Area & Roadway Manchester Brochure 1974

    3/6

    ,I I I ,I " ~ ~ ~ _ _ ! , ,_I

    L ~~~._. "

  • 8/2/2019 Sterner Area & Roadway Manchester Brochure 1974

    4/6

    DimensionsRecommendedLuminaire Size Standard MountingWattage and Height Arm Length Height

    MANCHESTER 100 upto 16" square X 5314" 8" 7'-6" to 12'-6"100wattsMANCHESTER 250 up to 23%" square x 9112" 12" 10' to 20'

    250wattsMANCHESTER 400 upto 30" square x 12%" 16" 15' to 30'

    400wattsMANCHESTER 1000 upto 37%" square x 143,4" 20" 25' to 39'

    1000 watts

    Photometric FlexibilityThe MANCHESTERlighting systemprovides exceptional lighting flexibility and efficiency. Wattages, for example,range up to 1000 watts in either incandescent or H.I.D. lamps. An exclusive Sterner system, comprised of anacrylic or optional polycarbonate refractor, an optically-engineered aluminum reflector, and an adjustable lamp-holder, allows selection of light distribution patterns to suit the requirements of the project. As a result, IESdistribution patterns II. Ill, IV, and modified V are available in all MANCHESTERluminaires. Patterns are easilyadjustable on-site should illumination requirements change. (Photometric tables for precise fixture and mount-ing height selection are found in SECTION14,Technical Information.) This system is designed and manufacturedto meet or exceed U.L. and N.E.C.requirements; all fixtures bear the I.B.EW. label.

    Options luminaires can be wall-mounted. photoelectric control. single or duplex weatherproof receptacle. bakedfinish available in a wide range of colors, applied electrostatically. pole materials: aluminum, steel, concrete,wood, wood-laid. pole cross-sections: round, square, hexagonal, octagonal. pole profiles: straight or tapered(for specific details, see SECTION 8, Poles) WOODLITE styles available (SeeSECTION 11, WOODLITE).

    Mounting Arrangements

    -I ] ISingle 2@900

    2@ 1800 4@9003@900

  • 8/2/2019 Sterner Area & Roadway Manchester Brochure 1974

    5/6

    EXAMPLE: MR 30 D 28 N 400 M 240 POLE:

    ORDERING INFORMATION:Obtain the catalog number for the luminaire series which fits your requirements. Select, in sequence,a code for each feature from those listed in the format illustrated below.

    16233037

    SPECIFYLAMPWATTAGE

    NOTE 120D 208240

    ,J. ~ "v"" 0"v ~ ~ff:-~"~v~ ~ V : -

    ~ 0" " -c~. : : , ; < c

    1

    277 NOTE Wind. load rating480 E table indicatesVND* minimum pole

    strength.See SECTION 8for pole selection.

    NOTE A NOTEC Wind Load Rating TableD - Clear Refractor Acrylic N ~ Options Not Desired Lumi- Luminaire Number &standard) P - Photoelectric Control naireE - Clear Refractor Size SpacingPoIycarbonate NOTED 10 28 29 32 39 49M - Mercury Vapor 16 3 4 4 5 5 6OTES H - Metal Halide10 - Single 5 - High Pressure Sodium 23 4 7 7 9 9 1128 - 2@1BOo I - Incandescent 30 6 12 12 15 15 1829-2@90o32-3@120o NOTEE 37 9 18 18 23 23 2539-3@90o Obtain color codes from *Voltage Not Determined49-4@90o paint color chart inSECTION 14.

  • 8/2/2019 Sterner Area & Roadway Manchester Brochure 1974

    6/6

    Sample Specification

    acrylic with UV inhibitor. Horizontal and verticalcontrol will be exercised on the light presented tothe refractor with resulting candlepower providingan even distribution of reflected light. Control ofhigh-angle candlepower to provide cutoff rating forall lamp types.Refractor will be encased in a four-piece extrud-ed aluminum frame with two silicone gasketssecured by mechanical means only, providing pro-tection against dirt and moisture. The door to behinged with stainless steel pins with safety clips.Latching will be done with two gOO-turnstainlesssteel latches.Arm assembly shall be an aluminum extrusionserving asa spacer between pole and housing.Twotie rods with prevailing-torque lock nuts shall se-cure the luminaire to the pole.The luminaire will bear the listing mark of Under-writers Lab. Fixtures suitable for use in wetlocations.

    The luminaire shall be formed of aluminum alloy6063 sheet with peaked roof, all welded into onehousing. Finish on housing shall be baked enamel.Ballast components, core and coil, capacitor, andfused terminal block shall be mounted on an alu-minum bar and mounted in area behind reflector.Ballast shall be capable of starting _type of lamp of, watts at__ voltage downto -20F. The 200C,600-volt insulated wiring shallbe installed between the 600-volt fused terminalblock, the ballast components, and the 600-voltclass socket. The socket to have nickel-platedcurrent-carrying parts with lamp grip.Reflector shall be .063 aluminum sheet or great-

    er, die formed, with polished Alzak" finish to giveproper distribution of reflected light into the refrac-tor, where along with the direct light it will provideIES light distribution type _The refractor shall be clear injection-molded

    STeRNeRLIGHTING SYSTEMS INCORPORATED

    Printed in U,S,A,Winsted, Minnesota 55395(612}485-2141

    College Point (Long Island), New York 11356(212}358-5655