Compliance Surgical Tables Incorporated (STI) manufactures medical devices that are compliant with the Center for Devices and Radiological Health (CDRH) Code of Federal Regulation 21 Subchapter J Part 1020 Section 30 (CFR21 Subchapter J part 1020.30), the performance standard for ionizing radiation emitting products. Additionally, STI's products are manufactured according to the Food & Drug Administrations (FDA) Current Good Manufacturing Practices (CGMP's). FDA PRODUCT CLASSIFICATION Device Description: Radiologic Table Product Code: KXJ Regulation Number: 892.1980 Device Class: 2 GMP Exempt: No 510(k) Exempt: Yes series series Technical Specifications movements movements MAX-PAINBROCHURE Rev 1 Radiolucent Imaging Tables for Pain Management 1. HEIGHT .................................. 29” TO 40” 2. LATERAL TILT....................... (+/-) 17º 3. TRENDELENbERG ............... (+/-) 20º 4. LONGITUDINAL TRAvEL ..... 10” ( + / - 5 " ) + - Max Series 4 Move Surgical Table Supply Voltage: 120 VAC ˜ 5% Max Current : 3.5A Frequency: 60 Hz 1. HEIGHT .................................. 28” TO 40” 2. LATERAL TILT....................... (+/-) 17º 3. TRENDELENbERG ............... (+/-) 20º + - Max Series 3 Move Surgical Table Supply Voltage: 120 VAC ˜ 5% Max Current : 3.5A Frequency: 60 Hz 1. HEIGHT .................................. 28” TO 40” 2. LATERAL TILT....................... (+/-) 17º + - Max Series 2 Move Surgical Table Supply Voltage: 120 VAC ˜ 5% Max Current : 3.5A Frequency: 60 Hz 1. HEIGHT .................................. 28” TO 40” 1. FIXED HEIGHT ...................... 36” + - Max Series 1 Move Surgical Table Supply Voltage: 120 VAC ˜ 5% Max Current : 3.5A Frequency: 60 Hz Max Series Surgical Table 1. HEIGHT .................................. 32” TO 42” 2. LATERAL TILT....................... (+/-) 17º 3. TRENDELENbERG ............... (+/-) 20º 4. LONGITUDINAL TRAvEL ..... 10” ( + / - 5 " ) 5. LATERAL TRAvEL ................ 10” ( + / - 5 " ) + - Max Series 5 Move Surgical Table Supply Voltage: 120 VAC ˜ 5% Max Current : 7A Frequency: 60 Hz

Upload: others

Post on 26-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: sti brochure2 no info - Surgical Tablessurgicaltables.com/.../2016/11/max_series_surgical_tables_brochure.… · • 2" patient pad is made of soft and flexible material for patient

Compliance

Surgical Tables Incorporated (STI) manufactures medical devices that are compliant with the Center for Devices and Radiological Health (CDRH) Code of Federal Regulation 21 Subchapter J Part 1020 Section 30 (CFR21 Subchapter J part 1020.30), the performance standard for ionizing radiation emitting products. Additionally, STI's products are manufactured according to the Food & Drug Administrations (FDA) Current Good Manufacturing Practices (CGMP's).

FDA PRODUCT CLASSIFICATIONDevice Description: Radiologic TableProduct Code: KXJRegulation Number: 892.1980Device Class: 2GMP Exempt: No510(k) Exempt: Yes

s e r i e s

s e r i e s

Technical Specifications

movementsmovements

MAX-PAINBROCHURE Rev 1

Radiolucent ImagingTables for Pain Management

1. HEIGHT .................................. 29” TO 40”2. LATERAL TILT ....................... ( + / - ) 17º3. TRENDELENbERG ............... ( + / - ) 20º4. LONGITUDINAL TRAvEL ..... 10” (+ / - 5 " )

+-

Max Series 4 Move Surgical TableSupply Voltage: 120 VAC ̃ 5%Max Current : 3.5AFrequency: 60 Hz

1. HEIGHT .................................. 28” TO 40”2. LATERAL TILT ....................... ( + / - ) 17º3. TRENDELENbERG ............... ( + / - ) 20º

+-Max Series 3 Move Surgical TableSupply Voltage: 120 VAC ̃ 5%Max Current : 3.5AFrequency: 60 Hz

1. HEIGHT .................................. 28” TO 40”2. LATERAL TILT ....................... ( + / - ) 17º

+-Max Series 2 Move Surgical TableSupply Voltage: 120 VAC ̃ 5%Max Current : 3.5AFrequency: 60 Hz

1. HEIGHT .................................. 28” TO 40”

1. FIXED HEIGHT ...................... 36”

+-

Max Series 1 Move Surgical TableSupply Voltage: 120 VAC ̃ 5%Max Current : 3.5AFrequency: 60 Hz

Max Series Surgical Table

1. HEIGHT .................................. 32” TO 42”2. LATERAL TILT ....................... ( + / - ) 17º3. TRENDELENbERG ............... ( + / - ) 20º4. LONGITUDINAL TRAvEL ..... 10” (+ / - 5 " )5. LATERAL TRAvEL ................ 10” (+ / - 5 " )

+-

Max Series 5 Move Surgical TableSupply Voltage: 120 VAC ̃ 5%Max Current : 7AFrequency: 60 Hz

Page 2: sti brochure2 no info - Surgical Tablessurgicaltables.com/.../2016/11/max_series_surgical_tables_brochure.… · • 2" patient pad is made of soft and flexible material for patient

STI Features

versatility

Suggested Radiation Safety Products

DD e s i g n e d t o s u p p o r t t h e l a t e s ta d v a n c e m e n t s i n s u r g i c a l p r o c e d u r e s a n di m a g i n g t e c h n i q u e s , s e t t i n g t h e s t a n d a r d f o ro p e r a t i n g e f f i c i e n c y , e r g o n o m i c s a n d s a f e t y .

• Protective bellows provides safety by enclosing all motors, controls and wiring. The protective bellows are also easily cleaned with standard operating or procedural room sanitizers (See Picture)

• Rated for 500 pound patients• The patient transfer bar is mounted to the removable side rail system and helps reduce "patient roll-over" when transferring a patient from a stretcher or gurney to the table (See Picture)

• 2" patient pad is made of soft and flexible material for patient comfort. The patient pad can be cleaned with standard operating or procedural room sanitizers. (See Picture)

• 2" patient pad is made of durable vinyl which is puncture and stain resistant. Vinyl is easily cleaned with standard operating or procedural room sanitizers.• MAX series imaging tables are very easy to move. A single nurse or staff person can easily rotate a MAX series imaging table when reversing the operating or procedural set-up• 4 swivel locking castors have a rated capacity of 1760 pounds. (See Picture)

• Modular side rail system accepts all OR accessories and allows for maximum radiolucency while not sacrificing surgical or procedural possibilities. The Modular side rail system locks into grooves on table top for maximum stability. (See Picture)

• Optional power adjustable backrest for Breast Augmentation motion• Optional wireless remote control. (See Picture)

• Uninterruptible Power Supply(UPS). See Picture)

• Optional foot controls. (See Picture)

SPINE SURGERY

ORTHOPEDIC PROCEDURESSPINAL INJECTIONSPAIN MANAGEMENT

LEADED GLOvES

LEAD TAbLE DRAPELEADED GLASSES

LEAD APRON

TRANSPARENT LEAD SHIELD

T h e M A X s e r i e s S u r g i c a l Tables prov ide a f lex ib le

solution for the medi-cal & budgetary con-cerns of al l surgical

environments.

POWER INDICATOR LAMP

LOCKING CASTORS

EMERGENCY STOP SWITCH

REMOvAbLE POWER CORD

PATIENT TRANSFER bAR

PROTECTIvE bELLOWS

SURGICAL ARMbOARDSPROCEDURAL ARMbOARDS

• 24" wide carbon fiber top (84” length) comfortably fits larger patients and in most cases eliminates the need for arm boards

• Emergency Stop Switch for maximum Operating or Procedural safety (See Picture)

• MAX series allows simultaneous motions for quick patient positioning

• Power indicator lamp on handset lights green when the table is in motion. (See Picture)

• Easily transfer patients from stretcher or gurney. Standard stretcher or gurney table tops can be flush with the MAX series radiolucent top allowing for easy pre or post procedural transfer for incapacitated patients.

• Modern base design allows for maximum c-arm clearance. The MAX series tables have the most c-arm clearance in the market.

• Low boarding height for elderly or wheelchair bound patients.

• Removable power cord for easy transport of imaging table (See Picture)

• Surgical Armboards incorporate 180 degrees of rotation which provides infinite arm positioning (See Picture)

• Advanced airway management system provides maximum access to the patient which adds to overall patient comfort

MODULAR SIDE RAIL SYSTEM

FOOT CONTROLSWIRELESS REMOTEUPS