1
Hardware Requirements
In C Drive : Min 4GB Free
RAM Should be: 1GB
Operating System : XP,XP SP1,XP SP2,Vista Business
DVD Reader
![Page 2: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/2.jpg)
2
Set IP Address to your LCT (Laptop/Desktop)
Start Control PanelNetwork ConnectionsRight Click on Local Area Connections Properties
![Page 3: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/3.jpg)
3
Precautions for installing LCT Software
1) “Local Area Connection” Should be in Active (The LCT should be connected to a LAN, The LAN can be activated, we can use Sub
rack/Office LAN/ADSL modem)
2) Give the IP address 129.9.0.200
3) We can use any RJ45 ( Straight or Cross) Cable to access node
4) We have to create “LCT” (i.e that Folder name should be LCT) folder in “C Drive”, Copy the DVD in to that Folder. Then We have to follow the bellow steps.
![Page 4: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/4.jpg)
4
Installation steps of iManagerT2000
Double click on the install.bat
Step 1
4
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
05/29/10
To Start Installation we have to type yes and press Enter
![Page 5: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/5.jpg)
5
Installation steps of iManagerT20005
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
05/29/10
We have to type 5 and press Enter ( i.e We are going to install “MSDE Edition for NMS Release”
Step 2
![Page 6: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/6.jpg)
6
Installation steps of iManagerT20006
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
05/29/10
Step 3
![Page 7: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/7.jpg)
7
Installation steps of iManagerT20007
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
05/29/10
Step 4
![Page 8: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/8.jpg)
8
Installation steps of iManagerT20008
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
05/29/10
Step 5
![Page 9: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/9.jpg)
9
Installation Steps of iManagerT20009
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.) 05/29/10
Step 6
![Page 10: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/10.jpg)
10
Installation Steps of iManagerT200010
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.) 05/29/10
Step 7
![Page 11: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/11.jpg)
11
Installation Steps of iManagerT2000
Step 8
![Page 12: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/12.jpg)
12
Installation Steps of iManagerT2000
Step 9
![Page 13: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/13.jpg)
13
Installation Steps of iManagerT2000
Step 10
![Page 14: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/14.jpg)
14
Installation Steps of iManagerT2000
Step 11
![Page 15: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/15.jpg)
15
Installation Steps of iManagerT2000
Step 12 Step 13
![Page 16: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/16.jpg)
16
Installation Steps of iManagerT2000
Step 14
![Page 17: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/17.jpg)
17
Installation Steps of iManagerT2000
Step 15
This password is default, if you want to change we can change
![Page 18: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/18.jpg)
18
Installation Steps of iManagerT2000
Step 16
![Page 19: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/19.jpg)
19
Installation Steps of iManagerT2000
Step 17
We have to wait atleast ½ Hour for installation to complete
Finally click Finish
Its asking Restart your System YES or NO, Select YES ( The PC has to be restarted )
Step 18
![Page 20: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/20.jpg)
20
Operation of iManagerT2000
How to login in to iManager T2000 First Login into “System Monitor” Next Login in to Client
Double click on the “” on your desktop.
20
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.) 05/29/10
User Name : adminPassword : T2000Server Name: Local
![Page 21: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/21.jpg)
21
How to Start iManager T2000
Note:
We have to “wait until all the services should be start”. ( i.e Service Should be Running State),
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.) 05/29/10
![Page 22: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/22.jpg)
22
How to Start iManager T2000
Note:
Now “T2000 System Monitor is Ready (i.e All the Services are in Running State), Now We have to Start “T2000 Client”
Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.) 05/29/10
![Page 23: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/23.jpg)
23
Operation of iManagerT2000
How to login in to iManager T2000 First Login into System Monitor Next Login in to Client
Double click on the “T2000-Client” on your desktop.
05/29/10Mr.S.S.Reddy (Prithvi Informations Solutions Ltd.)
23
User Name : adminPassword : T2000
![Page 24: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/24.jpg)
24
Searching For NE
To Search NE, we have to click on Auto Discovery
![Page 25: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/25.jpg)
25
Searching for NE (Adding the “lct” User)
Note:
1) Don’t use root user for NE search/login
2) So we have to add one more user (i.e Eg: LCT bangalore, LCT Anjimedu, LCT Adoni )
3) Password : password ( by Default )
![Page 26: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/26.jpg)
26
Searching for NE
Select the lct user then click Next
![Page 27: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/27.jpg)
27
Searching for NE
Wait up to Searching the all nodes in particular network
![Page 28: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/28.jpg)
28
Searching for NE
If searching is completed, all the nodes are displayed here, now here one node is displayed
![Page 29: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/29.jpg)
29
Searching for NE
User Name: lct
Password: password
![Page 30: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/30.jpg)
30
Configure the NE
Right click on the NE Select “Configure”
![Page 31: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/31.jpg)
31
Onfigure the NE( Manual Configuration)
If first time your going to configure the NE, select “Manual
Configuration”
Second time onwards it should be “Upload”
![Page 32: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/32.jpg)
32
Manual Configuration
![Page 33: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/33.jpg)
33
Manual Configuration
Self Type : Enhanced Sub rack
Remaining all the parameters are Default
![Page 34: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/34.jpg)
34
Manual Configuration
Note:
Check ( Front & Rare Panel) the Configuration which is available in physical NE with the Result on this LCT( Front & Rare Panel), If it is correct (i.e its appearing all the boards correctly) click NEXT
In Rare Panel JSTI Card (Slot No 58), its not appearing if you Query Physical Information. S we have to right click on the particular slot Select “Add JSTI ”
![Page 35: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/35.jpg)
35
![Page 36: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/36.jpg)
36
Configured NE Status
If we want to work on that particular NE, Select that NE in NE Information List and Click on the “NE Explorer”
If our configuration is completed, once check the Status in NE Information List (i.e Configured/ unconfigured )
![Page 37: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/37.jpg)
37
Open NE Explorer
![Page 38: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/38.jpg)
38
Synchronization NE with NM Time
Select NE Time Synchronization
Select NM
![Page 39: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/39.jpg)
39
Synchronization NE with NM Time
Right click on the NE,Select “Synchronize with NM Time”
![Page 40: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/40.jpg)
40
Set NE Performance Monitoring Time
Select the NE after that Enable the 15-Minute Monitoring time Then Apply
![Page 41: STM16_Huawei_(OSN_9500_&_7500)_Modified](https://reader034.vdocument.in/reader034/viewer/2022042713/544a378baf79596c4d8b45a4/html5/thumbnails/41.jpg)
41
Query Optical Power
Select Particular Optical Card, Under configuration Select
“Optical Power Management”, Then click on “Query”