stormwater management plan - cary · 2018-08-21 · est. 1 0 a nc lic. no. p-0799 z:\projects...

1
W W W W W W W W W RW RW RW RW RW RW RW RW SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S 315 315 310 305 300 L4 L5 L6 L7 1095 2098 2106 1307 13`0 1312 1311 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 161.80' 112.43' 31 36.04' 75.00' LOT 9,715 SQFT. 0.22 AC. MAXIMUM IMPERVIOUS SURFACE 4,500 SF VEGETATED SHELF PLANTINGS SLOPE STABILIZATION (TURF GRASS) SLOPE STABILIZATION (NATIVE GRASS) STORM DRAINAGE TABLE INLET# 200 201 TYPE FES RS RIM ELEV (EOP) 303.70 307.75 INV IN (FROM-SIZE) 301.37 (201-24") INV OUT (TO-SIZE) 304.50 (200-24") NOT FOR CONSTRUCTION DATE: FILE NO. HORZ. SCALE: ORIG. SHEET SIZE: REVISIONS ENGINEERING Curry 205 S. Fuquay Avenue Fuquay-Varina, NC 27526 (919) 552-0849 (919) 552-2043 C U R R Y E N G I N E E R S N O R T H C A R O L I N A EST. 10 NC LIC. NO. P-0799 T F Z:\PROJECTS FOLDER-ZEBULON\2016\2016-064 WACKENA ROAD - CARY, NC\PLANS\CONSTRUCTION DRAWINGS\SHEET FILES\C-12 STORMWATER MANAGEMENT PLAN.DWG PLOTTED: 7/26/2018 1:22 PM SEAL 24 x 36 Y T T E SEAL 36823 N A N N G I D R E W E E E P S. R S A R T H P R O N O F E S C R O L I N A I O N A L WELLFIELD DEVELOPMENT PLAN (#17-DP-0905) STORMWATER MANAGEMENT PLAN C-12 A 2/09/2017 2016-064 7/27/2017 TOWN OF CARY COMMENTS B 10/25/2017 TOWN OF CARY COMMENTS C 1/26/2018 TOWN OF CARY COMMENTS D 02/10/2018 TOWN OF CARY COMMENTS E 6/15/2018 TOWN OF CARY COMMENTS F 07/23/2018 NCDOT COMMENTS AS SHOWN 1. THIS DEVELOPMENT IS NOT LOCATED IN A FLOOD PLAIN. 2. THIS DEVELOPMENT IS LOCATED IN THE LOWER NEW HOPE WATERSHED WITHIN CAPE FEAR RIVER BASIN WITHIN THE JORDAN LAKE SUB-BASIN. PROJECT IS "HIGH DENSITY" OPTION DEVELOPMENT USING A WET DETENTION POND FOR TSS REMOVAL AND PEAK FLOW ATTENUATION. 3. WET DETENTION BASIN SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE NORTH CAROLINA DEPARTMENT OF NATURAL RESOURCES STORMWATER BMP MANUAL - LATEST EDITION. WET DETENTION BASIN PROVIDES WATER QUALITY TREATMENT FOR TSS, TN AND TP. 4. THE PROJECT MEETS ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LDO (CHAPTER 4 PART 4.6) 5. MAXIMUM SLOPE OF BASIN IS 3:1 6. ALL SIDE SLOPES, EMBANKMENTS AND SPILLWAYS SHALL BE COMPACTED TO MINIMUM 95% STANDARD PROCTOR PER ASTM-D698. 7. CONTROLLED FILL, AS SPECIFIED BY THE RESIDENT ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS (3-INCH LOOSE LAYERS WITHIN 3-FEET OF EITHER SIDE OF THE PRINCIPAL SPILLWAY PIPE TO A DEPTH OF 2-FEET OVER THE PIPE) AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM-D698. 8. ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL BE USED. STONES GREATER THAN 3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION. 9. FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE MATERIALS. 10. ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT. 11. SURFACE WATER AND STREAM FLOW SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF CONTROLLED FILL. 12. FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON THE PLANS. ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE MONITORED AND DOCUMENTED. IN NO CASE SHALLTHERE BE AN ATTEMPT TO STABILIZE AND PORTIONS OF THE FOUNDATION SOILS WITH CRUSHED STONE. 13. TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E., TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE RESIDENTIAL ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER. 14. FILL ADJACENT TO THE RISER AND PRINCIPAL SPILLWAY PIPE SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH SIDES OF THE STRUCTURES. 15. EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS. 16. COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED. 17. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST-IN-PLACE STRUCTURES UNTIL ADEQUATE CURING TIME HAS ELAPSED. 18. TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2- TO 3-INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED EMBANKMENT SURFACE AND THE AREA SEEDED AND MULCHED OR HYDROSEEDED. 19. ALL RISER STRUCTURES, INCLUDING WEIR WALL TYPE STRUCTURES, SHALL BE REINFORCED CONCRETE. BRICK/CONCRETE BLOCK AND MORTAR TYPE STRUCTURES WILL NOT BE ACCEPTED. 20. ALL RISER STRUCTURES SHALL BE LOCATED SUCH THAT DIRECT ACCESS FROM THE DAM EMBANKMENT CAN BE ACHIEVED. 21. RISER STRUCTURES WITH MULTIPLE BARREL SECTIONS SHALL HAVE GASKETTED JOINTS, AND EACH SECTION SHALL BE BOLTED TO ADJACENT SECTIONS WITH STAINLESS STEEL STRAPS. STEEL STRAPS SHALL BE MINIMUM 4" WIDE, 1/4" THICK, STRAP CENTERED ON JOINT WITH MINIMUM 2" OVERLAP. ATTACH STRAP TO BARREL SECTIONS WITH (2) 1/2" HEXBOLTS EMBEDDED IN STRUCTURE 3 INCHES. EPOXY BOLTS INTO STRUCTURE. 22. ALL SOIL MATERIAL BEHIND RETAINING WALLS SHALL BE AS REQUIRED BY SEGMENTAL BLOCK WALL MANUFACTURE. A DRAINAGE LAYER AS SPECIFIED BY MANUFACTURER SHALL BE INSTALLED. 23. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL TO ENGINEER OR OWNER FOR FENCE PRIOR TO INSTALLATION. 24. THIS PROJECT WILL MEET ALL REQUIREMENTS OF BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE (CHAPTER 4, PART 4.6). 25. CLAY LINER SHALL BE A MINIMUM 8 INCHES THICK. CLAY LINER SHALL BE INSTALLED AT A DEPTH SUFFICIENT ENOUGH SUCH THAT IT DOES NOT IMPEDED THE GROWTH OF VEGETATION OR CAN BE PENETRATED BY ROOTS OF VEGETATION. CLAY LINER SHALL LIMIT INFILTRATION RATE TO 0.01 IN/HR. CLAY LINER SHALL BE INSTALLED UP TO PERMANENT POOL ELEVATION THROUGHOUT POND. ALTERNATIVE LINERS MAYBE ACCEPTABLE IF APPROVED BY ENGINEER OF RECORD. GENERAL NOTES: SCALE: 1 C-12 WET DETENTION BASIN - PLAN VIEW 1"=20' SCALE: 2 C-12 WET DETENTION BASIN - SECTION VIEW N.T.S 20' 40' SCALE IN FEET 10' 20' SCALE: 1 IN = 20 FT SCALE IN FEET HORIZONTAL 0 SCALE: 5 C-12 EMERGENCY SPILLWAY DETAIL N.T.S. 3,000 PSI CONCRETE NO.3 STIRRUPS @ 12" O.C. NO.5 REBAR @ 12" O.C. 12" TYP 3" CLR 3" CLR NOTES: 1. CONCRETE DESIGN & CONSTRUCTION SHALL BE IN ACCORDANCE WITH LATEST EDITION OF ACI SPECIFICATIONS. CONCRETE SHALL BE A MINIMUM OF 3,000 PSI WITH #3 STIRRUPS AT 12" O.C. 2. CONTRACTOR SHALL FINISH ALL CONCRETE SURFACES WITH BROOM. 3. REINFORCING SHALL BE ASTM 615, GR 60. SPLICE LENGTHS SHALL BE CLASS B. 30' CREST LENGTH TOP OF DAM ELEV = 311.00 SPILLWAY ELEV = 310.00 NO.3 STIRRUPS @ 12" O.C. NO.5 REBAR @ 12" O.C. BOTTOM ELEV = 307.50 18" SCALE: 3 C-12 RISER STRUCTURE DETAIL N.T.S. 3:1 24" GASKETTED O-RING RCP OUTLET PIPE ANTI-VORTEX TRASH RACK ANCHORED TO RISER. CONTRACTOR TO SUBMIT SHOP DRAWINGS PRIOR TO INSTALLATION. ANCHOR TO CONCRETE RISER IN 4 LOCATIONS. MANHOLE STEPS, TYP CREST = 308.25 INV = 304.50 BOTTOM = 302.00 12" DRAW DOWN ORIFICE INV = 305.00 4"x4" PVC TEE 4" PLUG SET TOP OF PVC PLUG AT TEMPORARY POOL DRILL 2.0" Ø OPENING IN 4" PLUG TOP OF BERM = 311.00 FILL WITH LEAN CONCRETE FROM INVERT OF OUTLET PIPE TO MANHOLE EXTENDED BASE (4) 6" DIAMETER ORIFICE KNOCKOUTS INV ELEV= 306.75 BOTTOM OF POND ELEV = 300 PERMANENT POOL = 305.00 TEMPORARY POOL = 306.75 STANDARD MANHOLE BASE 6" 48" DIAMETER PRE-CAST MANHOLE PLANTING QUANTITIES SHELF AREA SHRUBS REQUIRED 2,166 SF 542 PLANTS **MINIMUM 50 PLANTS PER 200 SF OF VEGETATED SHELF AREA** HERBACEOUS PLANTS ACORUS SUBCORDATUM SWEETFLAG ALISMA SUBCORDATUM WATER PLANTAIN HYDROLEA QUADRIVALVIS WATERPOD IRIS VIRGINICA BLUE FLAG IRIS JUNCUS EFFUSUS VAR. PYLAEI OR SOLUTUS SOFT RUSH LUDWIGIA SPP. PRIMROSE WILLOW PELTANDRA VIRGINICA ARROW ARUM PONTEDERIA CORDATA PICKERELWEED SAGITTARIA LATIFOLIA DUCK POTATO SAGITTARIA LANCIFOLIA BULLTONGUE SAURURUS CERNUUS LIZARD’S TAIL SCHOENOPLECTUS TABERNAEMONTANI SOFT STEM BULRUSH SCHOENOPLECTUS AMERICANUS THREE-SQUARE BULRUSH SCHOENOPLECTUS PUNGENS VAR. PUNGENS SCIRPUS CYPERINUS WOOLGRASS ZIZANIOPSIS MILIACEA GIANT CUTGRASS SHALLOW WATER PLANT LIST BOTANICAL NAME COMMON NAME HERBACEOUS PLANTS ASCLEPIAS INCARNATA SWAMP MILKWEED CAREX TENERA QUILL SEDGE CHELONE GLABRA WHITE TURTLEHEAD EUPATORIADELPHUS DUBIUS DWARF JOE PYE WEED EUPATORIADELPHUS FISTULOSUS JOE PYE WEED EUPATORIADELPHUS MACULATUS SPOTTED TRUMPETWEED HIBISCUS COCCINEUS SCARLET ROSE MALLOW HIBISCUS LAEVIS HALBERDLEAF ROSEMALLOW KOSTELETZKYA VIRGINICA SEASHORE MALLOW LOBELIA CARDINALIS CARDINAL FLOWER LOBELIA ELONGATA LONGLEAF LOBELIA LOBELIA SIPHILITICA GREAT BLUE LOBELIA RHYNCHOSPORA COLORATA STARRUSH WHITETOP SACCHARUM BALDWINII NARROW PLUMEGRASS SHALLOW LAND PLANT LIST BOTANICAL NAME COMMON NAME SHRUBS ARONIA ARBUTIFOLIA RED CHOKEBERRY CEPHALANTHUS OCCIDENTALIS COMMON BUTTONBUSH CLETHRA ALNIFOLIA SWEET PEPPERBUSH CORNUS AMOMUM SILKY DOGWOOD CYRILLA RACEMIFLORA TITI GORDONIA LASIANTHUS LOBLOLLY BAY HYPERICUM DENSIFLORUM BUSHY ST. JOHNSWORT ILEX DECIDUAS POSSUMHAW ILEX GLABRA INKBERRY ITEA VIRGINICA VIRGINIA SWEETSPIRE ROSA PALUSTRIS SWAMP ROSE VACCINIUM CRASSIFOLIUM CREEPING BLUEBERRY VIBURNUM NUDUM VAR. NUDUM POSSUMHAW LEGEND 3:1 SLOPE STABILIZE WITH NATIVE GRASS (NO WEEPING LOVE GRASS) RIP RAP EMERGENCY SPILLWAY BOTTOM ELEV = 348.50 NCDOT CLASS "B" RIP RAP 24" RCP OUTLET PIPE 3:1 SLOPE CAST-IN-PLACE CONCRETE SPILLWAY-REFER TO DETAIL, THIS SHEET MAIN POND PERMANENT POOL = 305.00 TEMPORARY POOL = 306.75 TOP SEDIMENT ELEV = 300.50 BOTTOM SEDIMENT ELEV = 300.00 NOTES: 1. CONTRACTOR SHALL INSTALL FILTER DIAPHRAGM ON DAM OUTLET PIPE. 2. COORDINATE WITH ENGINEER ON APPROVED MATERIALS AND INSTALLATION TECHNIQUES PRIOR TO INSTALLATION. 3. LOCATION OF UNDERDRAINS MAY VARY TO DAYLIGHT. FLOW SCALE: 4 C-12 SAND DIAPHRAGM N.T.S. 3' 6' 6' 1.5 x DIA = 3' 3 x DIA =6'** 2' MIN. ** 2' MIN. FROM TOP OF DAM GOVERNS IF 3 x DIA. IS NOT AVALIABLE. 6' WIDE - 6:1 VEGETATED SHELF TOP ELEV.= 305.50 P.POOL ELEV = 305.00 BOTTOM ELEV.= 304.50 6' VEGETATED SHELF TOP OF DAM 24" RCP OUTLET FINE SAND FILTER PER ASTM C33 SHALLOW WATER SHALLOW LAND REFER TO TABLES ON THIS SHEET FOR PLANTING LIST & QUANTITY FOREBAY TOP SED. ELEV = 302.50 BOTTOM SED. ELEV = 302.00 FES 200 RS 201 1. WET POND PLANTINGS SHALL CONTAIN A MINIMUM OF 3 DIVERSE SPECIES OF SHALLOW WATER AND SHALLOW LAND HERBACEOUS VEGETATION ON THE VEGETATED SHELF. MINIMUM 50 PLANTS PER 200 SF OF VEGETATED SHELF AREA. SEE TABLE THIS SHEET FOR LIST OF APPROVED PLANTS. WETLAND SEED MIX IS NOT AN ACCEPTABLE SUBSTITUTE FOR PLANTINGS. WETLAND SEED MIX MAYBE USED WITH IN POOL. 2. SHALLOW WATER PLANTS SHALL BE PLANTED WITHIN AREA OF VEGETATED SHELF SUBMERGED 6 INCH IN THE PERMANENT POOL. SHALLOW LAND PLANTS SHALL BE PLANTED WITHIN AREA OF VEGETATED SHELF UN-SUBMERGED IN THE PERMANENT POOL. 3. PLANTS SHALL BE OF AT LEAST 4 CUBIC INCH CONTAINER SIZE. 4. SPACING OF PLANTINGS SHALL BE 24" TO 36" ON CENTERS. 5. IF TREES AND SHRUBS ARE PLANTED FOR AESTHETICS PER OWNER'S REQUEST, THEY SHALL BE OUTSIDE OF THE POND AND SELECTED TO MAXIMIZE SHADING. NO TREES SHALL BE PLANTED WITHIN THE EMBANKMENT OF THE POND. 6. TOP OF BERMS AND SLOPES SURROUNDING POND SHALL BE SEEDED WITH CENTIPEDE GRASS. 7. THE SOIL MIX MUST BE UNIFORM AND FREE OF STONES, STUMPS, ROOTS, OR OTHER SIMILAR MATERIAL GREATER THAN 2 INCHES IN DIAMETER. 8. THE PH SHOULD BE BETWEEN 4.5 AND 7.0. IF THE PH FALLS OUTSIDE OF THIS RANGE, IT MAY BE MODIFIED WITH LIME TO INCREASE THE PH OR IRON SULFATE AND SULFUR TO LOWER THE PH. THE LIME OR IRON SULFATE MUST BE MIXED UNIFORMLY INTO THE SOIL PRIOR TO USE. 9. TOPSOIL CAN BE NATIVE IF STOCKPILED ON-SITE SOILS OR IMPORTED TO THE DEVELOPMENT FROM OTHER LOCATIONS. PROVIDE SOIL ANALYSIS FOR ALL TOPSOIL TO BE USED WITHIN A BMP FACILITY. BMP LANDSCAPE NOTES: 24" TW / 314.00 BW / 308.00 TW / 314.00 BW / 308.00 TW / 311.50 BW / 311.00 TW / 312.75 BW / 308.00 300 305 310 310 305 SHALLOW WATER SHALLOW LAND TW / 313.75 BW / 308.00 TW / 313.00 BW / 311.00 TW / 311.50 BW / 311.00 RETAINING WALL WITH ORNAMENTAL FENCE AT TOP. REFER TO DETAILS FOREBAY BERM TOP ELEV = 306.00 WEIR ELEV = 305.00 11' RIP-RAP OUTLET PROTECTION NCDOT CLASS "1" RIP-RAP L=16', W1=6', W2=8', d=24" D50=13" Dmax=20" PERMANENT POOL ELEV = 305.00 10' WIDE BERM 30' EMERGENCY SPILLWAY WQV TEMPORARY POOL ELEV = 306.75 2' 42" HIGH ORNAMENTAL SAFETY FENCE MODULAR RETAINING WALL BOTTOM EL. 310 PRECAST RISER STRUCTURE W/ TRASH RACK-REFER TO DETAIL, THIS SHEET ELEV = 311.00 3 1 3 1 24" RCP @ 5.0% (O-RING JOINTS ASTM C443) COMPACTED SUBGRADE SAND DIAPHRAGM-REFER TO DETAIL, THIS SHEET MAIN PERMANENT POOL BOTTOM ELEV = 302.00 SEDIMENT STORAGE ELEV = 302.50 2.5 1 1 FOREBAY FOREBAY WEIR BOTTOM ELEV = 305.00 FOREBAY BERM TOP ELEV = 306.00 SEDIMENT STORAGE ELEV = 300.50 BOTTOM ELEV = 300.00 STORM WATER SURFACE ELEVATIONS 100 YEAR 310.70 25 YEAR 310.27 10 YEAR 309.60 5 YEAR 309.03 2 YEAR 308.43 1 YEAR 308.04 REFER TO TABLE ON THIS SHEET FOR WATER SURFACE ELEVATION AT DESIGN STORMS 2.5 6' VEGETATED SHELF AT 6:1 MAX SLOPE. PERMANENT POOL TO BE CENTERED IN SHELF 1 3 ** SHWT ELEVATION = 306.33 ** EMERGENCY SPILLWAY. REFER TO DETAIL ON THIS SHEET 4" PERFORATED PVC WRAPPED IN FABRIC TO DAYLIGHT 4" PERFORATED PVC WRAPPED IN FABRIC TO DAYLIGHT 3 1 REFER TO NOTES FOR EMBANKMENT COMPACTION CLAY LINER - REFER TO NOTE #25 RIP-RAP OUTLET PROTECTION NCDOT CLASS "B" RIP-RAP L=18', W1=9', W2=11', d=18" D50=6" Dmax=9" TOWN OF CARY SIGNATURE SET APPROVED by the Town of Cary Development Review Committee 08/09/2018 By: Kevin A. Hales

Upload: others

Post on 12-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: STORMWATER MANAGEMENT PLAN - Cary · 2018-08-21 · est. 1 0 a nc lic. no. p-0799 z:\projects folder-zebulon\2016\2016-064 wackena road - cary, nc\plans\construction drawings\sheet

W

WW W

W

W

W

W

W

RW

RWRW RW

RW

RW

RW

RW

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS SS SS

SS

SS

SS

SS

SS

SS

SS

SSSS

SSSS

SSSS

SSSS

SS

SS

SS

SS

SS

SS

SS

S

315

315

310

305

300L4

L5

L6

L7

1095

2098

2106

1307

13`0

1312

1311

X

XXXX

X

X

X

X

X

X

X

X

X

XX

XX

XX

X

X

X

X

X

XX

XX

XX

X

161.80'

112.

43'

31

36.04'

75.00'

LOT

9,715 SQFT.0.22 AC.

MAXIMUM IMPERVIOUSSURFACE 4,500 SF

VEGETATED SHELFPLANTINGS

SLOPE STABILIZATION(TURF GRASS)

SLOPE STABILIZATION(NATIVE GRASS)

STORM DRAINAGE TABLE

INLET#

200

201

TYPE

FES

RS

RIM ELEV(EOP)

303.70

307.75

INV IN(FROM-SIZE)

301.37(201-24")

INV OUT(TO-SIZE)

304.50(200-24")

NOT FOR CONSTRUCTION

DA

TE

:

FIL

E N

O.

HO

RZ

. SC

ALE

:

OR

IG. S

HE

ET

SIZ

E:

RE

VIS

ION

S

EN

GIN

EE

RIN

G

Curry

205

S. F

uqua

y A

venu

e

Fuq

uay-

Var

ina,

NC

275

26

(919

) 55

2-08

49

(919

) 55

2-20

43

CURRY

E

NG

IN

E

E R S

N OR

TH

C

AR

OL

INA

ES

T.

10

NC

LIC

. N

O.

P-0

79

9

T F

Z:\P

RO

JEC

TS

FO

LDE

R-Z

EB

ULO

N\2

016\

2016

-064

WA

CK

EN

A R

OA

D -

CA

RY

, NC

\PLA

NS

\CO

NS

TR

UC

TIO

N D

RA

WIN

GS

\SH

EE

T F

ILE

S\C

-12

ST

OR

MW

AT

ER

MA

NA

GE

ME

NT

PLA

N.D

WG

PLO

TT

ED

: 7/2

6/20

18 1

:22

PM

SEAL

24 x

36

YTTE

SEAL36823

N

AN N G IDR EW

EE E

PS.

R

S

ARTH

PR

ON OFES

C ROL I NAI ONAL

WE

LL

FIE

LD

DE

VE

LO

PM

EN

T P

LA

N (

#1

7-D

P-0

90

5)

ST

OR

MW

AT

ER

MA

NA

GE

ME

NT

PL

AN

C-12

A

2/09

/201

7

2016

-064

7/27

/201

7T

OW

N O

F C

AR

Y C

OM

ME

NT

SB

10/2

5/20

17T

OW

N O

F C

AR

Y C

OM

ME

NT

SC

1/26

/201

8T

OW

N O

F C

AR

Y C

OM

ME

NT

SD

02/1

0/20

18T

OW

N O

F C

AR

Y C

OM

ME

NT

SE

6/15

/201

8T

OW

N O

F C

AR

Y C

OM

ME

NT

SF

07/2

3/20

18N

CD

OT

CO

MM

EN

TS

AS

SH

OW

N

1. THIS DEVELOPMENT IS NOT LOCATED IN A FLOOD PLAIN.

2. THIS DEVELOPMENT IS LOCATED IN THE LOWER NEW HOPE WATERSHED WITHIN CAPE FEAR RIVER BASIN WITHIN THE JORDAN LAKE

SUB-BASIN. PROJECT IS "HIGH DENSITY" OPTION DEVELOPMENT USING A WET DETENTION POND FOR TSS REMOVAL AND PEAK FLOW

ATTENUATION.

3. WET DETENTION BASIN SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE NORTH CAROLINA DEPARTMENT OF

NATURAL RESOURCES STORMWATER BMP MANUAL - LATEST EDITION. WET DETENTION BASIN PROVIDES WATER QUALITY TREATMENT

FOR TSS, TN AND TP.

4. THE PROJECT MEETS ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER

CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LDO (CHAPTER 4 PART 4.6)

5. MAXIMUM SLOPE OF BASIN IS 3:1

6. ALL SIDE SLOPES, EMBANKMENTS AND SPILLWAYS SHALL BE COMPACTED TO MINIMUM 95% STANDARD PROCTOR PER ASTM-D698.

7. CONTROLLED FILL, AS SPECIFIED BY THE RESIDENT ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS

(3-INCH LOOSE LAYERS WITHIN 3-FEET OF EITHER SIDE OF THE PRINCIPAL SPILLWAY PIPE TO A DEPTH OF 2-FEET OVER THE PIPE) AND

SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE

CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM-D698.

8. ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO

THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL BE USED. STONES GREATER THAN

3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION.

9. FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE

SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH

ACCEPTABLE MATERIALS.

10. ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY

SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT.

11. SURFACE WATER AND STREAM FLOW SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF

CONTROLLED FILL.

12. FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON

THE PLANS. ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE

MONITORED AND DOCUMENTED. IN NO CASE SHALLTHERE BE AN ATTEMPT TO STABILIZE AND PORTIONS OF THE FOUNDATION SOILS

WITH CRUSHED STONE.

13. TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E.,

TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE RESIDENTIAL

ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER.

14. FILL ADJACENT TO THE RISER AND PRINCIPAL SPILLWAY PIPE SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH

SIDES OF THE STRUCTURES.

15. EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY

DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS.

16. COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED.

17. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST-IN-PLACE STRUCTURES UNTIL ADEQUATE CURING TIME HAS

ELAPSED.

18. TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2- TO 3-INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED

EMBANKMENT SURFACE AND THE AREA SEEDED AND MULCHED OR HYDROSEEDED.

19. ALL RISER STRUCTURES, INCLUDING WEIR WALL TYPE STRUCTURES, SHALL BE REINFORCED CONCRETE. BRICK/CONCRETE BLOCK AND

MORTAR TYPE STRUCTURES WILL NOT BE ACCEPTED.

20. ALL RISER STRUCTURES SHALL BE LOCATED SUCH THAT DIRECT ACCESS FROM THE DAM EMBANKMENT CAN BE ACHIEVED.

21. RISER STRUCTURES WITH MULTIPLE BARREL SECTIONS SHALL HAVE GASKETTED JOINTS, AND EACH SECTION SHALL BE BOLTED TO

ADJACENT SECTIONS WITH STAINLESS STEEL STRAPS. STEEL STRAPS SHALL BE MINIMUM 4" WIDE, 1/4" THICK, STRAP CENTERED ON

JOINT WITH MINIMUM 2" OVERLAP. ATTACH STRAP TO BARREL SECTIONS WITH (2) 1/2" HEXBOLTS EMBEDDED IN STRUCTURE 3 INCHES.

EPOXY BOLTS INTO STRUCTURE.

22. ALL SOIL MATERIAL BEHIND RETAINING WALLS SHALL BE AS REQUIRED BY SEGMENTAL BLOCK WALL MANUFACTURE. A DRAINAGE

LAYER AS SPECIFIED BY MANUFACTURER SHALL BE INSTALLED.

23. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL TO ENGINEER OR OWNER FOR FENCE PRIOR TO INSTALLATION.

24. THIS PROJECT WILL MEET ALL REQUIREMENTS OF BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL

STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE (CHAPTER 4, PART 4.6).

25. CLAY LINER SHALL BE A MINIMUM 8 INCHES THICK. CLAY LINER SHALL BE INSTALLED AT A DEPTH SUFFICIENT ENOUGH SUCH THAT IT

DOES NOT IMPEDED THE GROWTH OF VEGETATION OR CAN BE PENETRATED BY ROOTS OF VEGETATION. CLAY LINER SHALL LIMIT

INFILTRATION RATE TO 0.01 IN/HR. CLAY LINER SHALL BE INSTALLED UP TO PERMANENT POOL ELEVATION THROUGHOUT POND.

ALTERNATIVE LINERS MAYBE ACCEPTABLE IF APPROVED BY ENGINEER OF RECORD.

GENERAL NOTES:

SCALE:

1

C-12

WET DETENTION BASIN - PLAN VIEW1"=20'

SCALE:

2

C-12

WET DETENTION BASIN - SECTION VIEWN.T.S

20' 40'

SCALE IN FEET

10'20'

SCALE: 1 IN = 20 FT

SCALE IN FEETHORIZONTAL

0

SCALE:

5

C-12

EMERGENCY SPILLWAY DETAILN.T.S.

3,000 PSI CONCRETE

NO.3 STIRRUPS @ 12" O.C.

NO.5 REBAR @ 12" O.C.

12" TYP

3" CLR

3" CLR

NOTES:

1. CONCRETE DESIGN & CONSTRUCTION SHALL BE IN ACCORDANCE WITH LATEST EDITION

OF ACI SPECIFICATIONS. CONCRETE SHALL BE A MINIMUM OF 3,000 PSI WITH #3

STIRRUPS AT 12" O.C.

2. CONTRACTOR SHALL FINISH ALL CONCRETE SURFACES WITH BROOM.

3. REINFORCING SHALL BE ASTM 615, GR 60. SPLICE LENGTHS SHALL BE CLASS B.

30'

CREST LENGTH

TOP OF DAM

ELEV = 311.00SPILLWAY

ELEV = 310.00

NO.3 STIRRUPS @ 12" O.C.

NO.5 REBAR @ 12" O.C.

BOTTOM

ELEV = 307.50

18"

SCALE:

3

C-12

RISER STRUCTURE DETAILN.T.S.

3:1

24" GASKETTED O-RING

RCP OUTLET PIPE

ANTI-VORTEX TRASH RACK

ANCHORED TO RISER. CONTRACTOR

TO SUBMIT SHOP DRAWINGS PRIOR

TO INSTALLATION. ANCHOR TO

CONCRETE RISER IN 4 LOCATIONS.

MANHOLE

STEPS, TYP

CREST = 308.25

INV = 304.50

BOTTOM = 302.00

12"

DRAW DOWN

ORIFICE

INV = 305.00

4"x4" PVC TEE

4" PLUG

SET TOP OF PVC PLUG AT

TEMPORARY POOL

DRILL 2.0" ØOPENING IN 4" PLUG

TOP OF

BERM = 311.00

FILL WITH LEAN CONCRETE

FROM INVERT OF OUTLET PIPE

TO MANHOLE EXTENDED BASE

(4) 6" DIAMETER ORIFICE

KNOCKOUTS

INV ELEV= 306.75

BOTTOM OF POND

ELEV = 300

PERMANENT POOL = 305.00

TEMPORARY POOL = 306.75

STANDARD

MANHOLE BASE

6"

48" DIAMETER

PRE-CAST

MANHOLE

PLANTING QUANTITIES

SHELF AREA SHRUBS REQUIRED

2,166 SF 542 PLANTS

**MINIMUM 50 PLANTS PER 200 SF OF VEGETATED SHELF AREA**

HERBACEOUS PLANTS

ACORUS SUBCORDATUM SWEETFLAG

ALISMA SUBCORDATUM WATER PLANTAIN

HYDROLEA QUADRIVALVIS WATERPOD

IRIS VIRGINICA BLUE FLAG IRIS

JUNCUS EFFUSUS VAR. PYLAEI OR SOLUTUS SOFT RUSH

LUDWIGIA SPP. PRIMROSE WILLOW

PELTANDRA VIRGINICA ARROW ARUM

PONTEDERIA CORDATA PICKERELWEED

SAGITTARIA LATIFOLIA DUCK POTATO

SAGITTARIA LANCIFOLIA BULLTONGUE

SAURURUS CERNUUS LIZARD’S TAILSCHOENOPLECTUS TABERNAEMONTANI SOFT STEM BULRUSH

SCHOENOPLECTUS AMERICANUS THREE-SQUARE BULRUSH

SCHOENOPLECTUS PUNGENS VAR. PUNGENS

SCIRPUS CYPERINUS WOOLGRASS

ZIZANIOPSIS MILIACEA GIANT CUTGRASS

SHALLOW WATER PLANT LIST

BOTANICAL NAME COMMON NAME

HERBACEOUS PLANTS

ASCLEPIAS INCARNATA SWAMP MILKWEED

CAREX TENERA QUILL SEDGE

CHELONE GLABRA WHITE TURTLEHEAD

EUPATORIADELPHUS DUBIUS DWARF JOE PYE WEED

EUPATORIADELPHUS FISTULOSUS JOE PYE WEED

EUPATORIADELPHUS MACULATUS SPOTTED TRUMPETWEED

HIBISCUS COCCINEUS SCARLET ROSE MALLOW

HIBISCUS LAEVIS HALBERDLEAF ROSEMALLOW

KOSTELETZKYA VIRGINICA SEASHORE MALLOW

LOBELIA CARDINALIS CARDINAL FLOWER

LOBELIA ELONGATA LONGLEAF LOBELIA

LOBELIA SIPHILITICA GREAT BLUE LOBELIA

RHYNCHOSPORA COLORATA STARRUSH WHITETOP

SACCHARUM BALDWINII NARROW PLUMEGRASS

SHALLOW LAND PLANT LIST

BOTANICAL NAME COMMON NAME

SHRUBS

ARONIA ARBUTIFOLIA RED CHOKEBERRY

CEPHALANTHUS OCCIDENTALIS COMMON BUTTONBUSH

CLETHRA ALNIFOLIA SWEET PEPPERBUSH

CORNUS AMOMUM SILKY DOGWOOD

CYRILLA RACEMIFLORA TITI

GORDONIA LASIANTHUS LOBLOLLY BAY

HYPERICUM DENSIFLORUM BUSHY ST. JOHNSWORT

ILEX DECIDUAS POSSUMHAW

ILEX GLABRA INKBERRY

ITEA VIRGINICA VIRGINIA SWEETSPIRE

ROSA PALUSTRIS SWAMP ROSE

VACCINIUM CRASSIFOLIUM CREEPING BLUEBERRY

VIBURNUM NUDUM VAR. NUDUM POSSUMHAW

LEGEND

3:1 SLOPE

STABILIZE WITH NATIVE

GRASS (NO WEEPING LOVE

GRASS)

RIP RAP EMERGENCY

SPILLWAY

BOTTOM ELEV = 348.50

NCDOT CLASS "B" RIP RAP24" RCP OUTLET

PIPE

3:1 SLOPE

CAST-IN-PLACE CONCRETE

SPILLWAY-REFER TO

DETAIL, THIS SHEET

MAIN POND

PERMANENT POOL = 305.00

TEMPORARY POOL = 306.75

TOP SEDIMENT ELEV = 300.50

BOTTOM SEDIMENT ELEV = 300.00

NOTES:

1. CONTRACTOR SHALL INSTALL FILTER

DIAPHRAGM ON DAM OUTLET PIPE.

2. COORDINATE WITH ENGINEER ON

APPROVED MATERIALS AND INSTALLATION

TECHNIQUES PRIOR TO INSTALLATION.

3. LOCATION OF UNDERDRAINS MAY VARY

TO DAYLIGHT.

FLOW

SCALE:

4

C-12

SAND DIAPHRAGMN.T.S.

3'

6'6'

1.5 x DIA = 3'

3 x DIA =6'**

2' MIN.

** 2' MIN. FROM TOP OF DAM

GOVERNS IF 3 x DIA. IS NOT

AVALIABLE.

6' WIDE - 6:1 VEGETATED SHELF

TOP ELEV.= 305.50

P.POOL ELEV = 305.00

BOTTOM ELEV.= 304.50

6' VEGETATED

SHELF

TOP OF DAM

24" RCP

OUTLET

FINE SAND FILTER

PER ASTM C33

SHALLOW WATERSHALLOW LAND

REFER TO TABLES ON

THIS SHEET FOR

PLANTING LIST &

QUANTITY

FOREBAY

TOP SED. ELEV = 302.50

BOTTOM SED. ELEV = 302.00

FES

200

RS

201

1. WET POND PLANTINGS SHALL CONTAIN A MINIMUM OF 3 DIVERSE SPECIES OF SHALLOW WATER AND SHALLOW LAND

HERBACEOUS VEGETATION ON THE VEGETATED SHELF. MINIMUM 50 PLANTS PER 200 SF OF VEGETATED SHELF AREA. SEE

TABLE THIS SHEET FOR LIST OF APPROVED PLANTS. WETLAND SEED MIX IS NOT AN ACCEPTABLE SUBSTITUTE FOR

PLANTINGS. WETLAND SEED MIX MAYBE USED WITH IN POOL.

2. SHALLOW WATER PLANTS SHALL BE PLANTED WITHIN AREA OF VEGETATED SHELF SUBMERGED 6 INCH IN THE PERMANENT

POOL. SHALLOW LAND PLANTS SHALL BE PLANTED WITHIN AREA OF VEGETATED SHELF UN-SUBMERGED IN THE PERMANENT

POOL.

3. PLANTS SHALL BE OF AT LEAST 4 CUBIC INCH CONTAINER SIZE.

4. SPACING OF PLANTINGS SHALL BE 24" TO 36" ON CENTERS.

5. IF TREES AND SHRUBS ARE PLANTED FOR AESTHETICS PER OWNER'S REQUEST, THEY SHALL BE OUTSIDE OF THE POND AND

SELECTED TO MAXIMIZE SHADING. NO TREES SHALL BE PLANTED WITHIN THE EMBANKMENT OF THE POND.

6. TOP OF BERMS AND SLOPES SURROUNDING POND SHALL BE SEEDED WITH CENTIPEDE GRASS.

7. THE SOIL MIX MUST BE UNIFORM AND FREE OF STONES, STUMPS, ROOTS, OR OTHER SIMILAR MATERIAL GREATER THAN 2

INCHES IN DIAMETER.

8. THE PH SHOULD BE BETWEEN 4.5 AND 7.0. IF THE PH FALLS OUTSIDE OF THIS RANGE, IT MAY BE MODIFIED WITH LIME TO

INCREASE THE PH OR IRON SULFATE AND SULFUR TO LOWER THE PH. THE LIME OR IRON SULFATE MUST BE MIXED

UNIFORMLY INTO THE SOIL PRIOR TO USE.

9. TOPSOIL CAN BE NATIVE IF STOCKPILED ON-SITE SOILS OR IMPORTED TO THE DEVELOPMENT FROM OTHER LOCATIONS.

PROVIDE SOIL ANALYSIS FOR ALL TOPSOIL TO BE USED WITHIN A BMP FACILITY.

BMP LANDSCAPE NOTES:

24"

TW / 314.00

BW / 308.00

TW / 314.00

BW / 308.00

TW / 311.50

BW / 311.00

TW / 312.75

BW / 308.00

300

305

310

310

305

SHALLOW WATER

SHALLOW LAND

TW / 313.75

BW / 308.00

TW / 313.00

BW / 311.00

TW / 311.50

BW / 311.00

RETAINING WALL WITH

ORNAMENTAL FENCE AT

TOP. REFER TO DETAILS

FOREBAY BERM

TOP ELEV = 306.00

WEIR ELEV = 305.00

11'

RIP-RAP OUTLET PROTECTION

NCDOT CLASS "1" RIP-RAP

L=16', W1=6', W2=8', d=24"

D50=13"

Dmax=20"

PERMANENT POOL ELEV = 305.00

10' WIDE

BERM

30' EMERGENCY SPILLWAY

WQV TEMPORARY POOL ELEV = 306.75

2'

42" HIGH ORNAMENTAL

SAFETY FENCE

MODULAR RETAINING

WALL

BOTTOM EL. 310

PRECAST RISER STRUCTURE

W/ TRASH RACK-REFER TO

DETAIL, THIS SHEET

ELEV = 311.00

3

1

3

1

24" RCP @ 5.0%(O-RING JOINTS ASTM C443)

COMPACTED SUBGRADE

SAND DIAPHRAGM-REFER

TO DETAIL, THIS SHEET

MAIN PERMANENT POOL

BOTTOM ELEV = 302.00

SEDIMENT STORAGE

ELEV = 302.50

2.5

11 FOREBAY

FOREBAY WEIR BOTTOM

ELEV = 305.00

FOREBAY BERM

TOP ELEV = 306.00

SEDIMENT STORAGE ELEV = 300.50

BOTTOM ELEV = 300.00STORM WATER SURFACE ELEVATIONS

100 YEAR 310.70

25 YEAR 310.27

10 YEAR 309.60

5 YEAR 309.03

2 YEAR 308.43

1 YEAR 308.04

REFER TO TABLE ON THIS

SHEET FOR WATER SURFACE

ELEVATION AT DESIGN STORMS

2.5

6' VEGETATED SHELF AT 6:1 MAX

SLOPE. PERMANENT POOL TO BE

CENTERED IN SHELF1

3

** SHWT ELEVATION = 306.33 **

EMERGENCY SPILLWAY.

REFER TO DETAIL ON THIS

SHEET

4" PERFORATED PVC

WRAPPED IN FABRIC TO

DAYLIGHT

4" PERFORATED PVC

WRAPPED IN FABRIC TO

DAYLIGHT

3

1

REFER TO NOTES FOR

EMBANKMENT COMPACTION

CLAY LINER - REFER TO

NOTE #25

RIP-RAP OUTLET PROTECTION

NCDOT CLASS "B" RIP-RAP

L=18', W1=9', W2=11', d=18"

D50=6"

Dmax=9"

TOWN OF CARY SIGNATURE SET

APPROVED by the Town of CaryDevelopment Review Committee

08/09/2018By: Kevin A. Hales