streaming server installation and operation...

11
1 \ Streaming server installation and operation manual

Upload: others

Post on 10-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�1

\

Rev

Streaming server installation and operation manual

Page 2: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�2

SECTION DESCRIPTION PAGE

1 General Information 3

1.1 Introduction 3

1.2 Purpose of the equipment 3

2 Application 3

2.1 Introduction 3

2.2 Typical application 43 Installation 4

3.1 Prior to installation 4

3.2 Cautions and warnings 6

3.3 Wiring 6

3.4 Physical Characteristics 6

3.5 Electrical Characteristics 6

3.6 Post Installation Test 6

3.7 Troubleshooting 74 Layout and Operation 9

4.1 Layout diagram 9

4.2 Lamp Codes 9

4.3 Operation 10

5 Specifications 11

Page 3: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�3

1.0 General Information 1.1 Introduction This manual contains information for the proper installation of the Advanced Offshore Streaming (AOS) SD Streaming server. Also included are physical and electrical characteristics of the unit.

1.2 Purpose of the equipment AOS’s SD Streaming server (SDSS) has been designed to offer low bandwidth composite video streaming to a globally accessible shore based server. In the recommended installation, the unit receives power from a 240v AC Source, Video from a composite video source, and internet via an ethernet port.

2.0 Application

2.1 Introduction The SDSS is a 100-240 Vac product that serves as a rack mount unit. It contains a seperate processing unit, cooling system, and video multiplexer. The unit is designed with simplicity in mind, with a single composite BNC Video port, a single IEC Power connection, and a single RJ45 ethernet port.

Page 4: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�4

2.2 Typical application Within a rack mount environment, the SDSS will be installed above or below other servers. Specific rack mount instructions apply to the installation process. Please see section 3 for more details. 3.0 Installation

3.1 Prior to installation The SDSS is a simple module to install. Before installation, the following items should be considered

3.1.1 Careful consideration of the location of the SDSS is necessary. Some of the items to consider include: * Space to allow adequate airflow

* Length of cable runs * Environmental conditions

* Access for service repair (if applicable) * Detailed rack mount instructions 3.1.3 3.1.2 The SDSS shall be installed to conform to the standards designated by the customer and manufacturer specifications as to the unit location and type of installation.

Page 5: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�5

3.1.3 The following rack mount instructions should be followed:

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature specified by the following table:

Operating temperature : 10° to 35° C (50° to 95° F)Storage temperature : -40° to 47° C (-40° to 116° F)

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

D) Cautions and Warnings – All caution and warning instructions noted on the product and in the manual should be followed (see Section 3.2 below for details).

Page 6: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�6

3.2 Cautions and Warnings 3.3.1 Do not remove any factory-installed screws 3.3.2 Do not install near heat sources 3.3.3 ESD (Electro Static Discharge) precautions shall be followed when installing

3.3 Wiring Requirements 3.4.1 The length and routing of external cables should be carefully studied and planned before attempting installation of the equipment. Allow adequate space for installation of cable and connectors. Ensure mechanical support of cables is not relied upon the connector.

Please observe the following requirements: A) A BNC Composite video signal is required on the rear BNC connector and will be the video source for the live stream. B) An internet connection is required via the rear RJ45 connector C) A clean power supply conforming to the below electrical characteristics is required (see 3.5 for details)

Page 7: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�7

3.4 Physical characteristics 3.5.1 The SDSS shall be located away from heat sources, magnetic fields and areas with excessive dust. 3.5.2 When using a rack mount, the unit shall be rigidly mounted to its location using the appropriate hardware

3.5 Electrical characteristics Input Voltage : 100-240Vac 50-60Hz Ethernet : 10/100/1000BASE‑T Ethernet (RJ-45 connector)

Video : Composite video source

3.6 Post installation test 3.6.1 The authorised installer will be supplied with the stream password. 3.6.2 Ensure all installation and input requirements have been met and are confirmed working. 3.6.3 Press the power button on the front panel to power the unit on. 3.6.4 Wait 60 seconds for the system to power up 3.6.5 Press the start stream button and the bezel will turn green to confirm a successful stream. (note : this does not guarantee an input signal)

Page 8: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�8

3.6.6 Confirm live stream present by accessing the online location. The stop stream button is used to cancel a live stream, in which case the stream start stream green led will be extinguished. 3.7 Troubleshooting 3.7.1 If the stop stream red LED is illuminated after startup, the SDSS has not detected a reliable internet connection.Please check the connection. 3.7.2 If the online stream is showing a black screen with coloured flashing bars, the input signal is not recognised, or is missing. 3.7.3 Occasionally due to unforeseen network errors, power surges etc, the unit may become unresponsive. To correct, power cycle the unit by holding the power button for 6 seconds until the system powers off, then power back on. 3.7.4 A flashing power light is not a fault, it is an indication the unit is in power save mode. Press the start stream button to wake the system.

3.7.5 Contact us below for any help / questions relating to operation or installation.

Page 9: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�9

4.0 Layout and Operation

4.1 Layout diagram

4.2 Lamp Codes

Solid Green Lamp - Connection with AOS Server established, streaming.

Flashing Green Lamp - Connecting to AOS Server. Can take several minutes initially. Solid Red Lamp - Network error, WAN connection to AOS Server Not available.

Page 10: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�10

4.3 Operation To power on the unit after initial installation or power fail, press the power button above.

To start streaming, press the Start stream button. the green button bezel will flash periodically while the unit establishes a live stream. When the stream is established, the green light will become solid. If the stream is periodically lost due to network conditions, the lamp will begin flashing until the stream is re-established. No user input is required after the initial start stream button press.

To stop streaming, press the stop stream button, The green stream indication on the start stream button will extinguish when the stream has halted.

note: If the Red Stop stream button is solid illuminated, this indicates the network connection has failed, and the unit can not establish a stream. The unit will not attempt to connect in this state. Periodic flashes of the stop stream lamp are normal during connection attempts.

Page 11: Streaming server installation and operation manualadvancedoffshorestreaming.com/Support/AVRManual.pdf · 3 Installation 4 3.1 Prior to installation 4 3.2 Cautions and warnings 6 3.3

�11

Power and requirements Input Voltage : 100-240Vac 50-60HzTypical Consumption : 600wOperating temperature : 10° to 35° C (50° to 95° F)Storage temperature : -40° to 47° C (-40° to 116° F)Relative humidity : 5% to 95% non-condensingWAN : Min 256KbpsTypical acoustical performance: Sound pressure level (operator position): less than 45dBA at idle

Input Ethernet : 10/100/1000BASE‑T Ethernet (RJ-45 connector) Video : DVI / HDMI / SDI / Composite / Component / RF / Ethernet

Mounting Form factor : 1u - 5u 19" Rack mount enclosure Construction : Aluminium / Stainless / Plastic

Operations ManagerJimmy Dean+61 (0) 490 667 [email protected]

Lead DeveloperJaron Warburton+61 (0) 400 753 [email protected]

Please forward ordering information and queries to:

Please forward compatibility and installation queries to :

5. Specifications