Strengthening of Steel Girder Bridges Using Fiber Reinforced Polymer (FRP) Strengthening of Steel Girder Strengthening of Steel Girder Bridges Using Fiber Reinforced Bridges Using Fiber Reinforced Polymer (FRP) Polymer (FRP) B. M. Phares, T. J. Wipf, F. W. Klaiber, A. Abu-Hawash, Y. S. Lee Bridge Engineering Center Iowa State University

Upload: others

Post on 27-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Strengthening of Steel Girder Bridges Using Fiber

Strengthening of Steel Girder Bridges Using Fiber Reinforced

Polymer (FRP)

Strengthening of Steel Girder Strengthening of Steel Girder Bridges Using Fiber Reinforced Bridges Using Fiber Reinforced

Polymer (FRP) Polymer (FRP)

B. M. Phares, T. J. Wipf, F. W. Klaiber, A. Abu-Hawash, Y. S. Lee

Bridge Engineering CenterIowa State University

Page 2: Strengthening of Steel Girder Bridges Using Fiber

BackgroundBackgroundBackground

Need some level of strengthening due to – Increases in live loads – Loss of capacity (deterioration)

Bridges not critical enough to warrant replacementNeed to employ structurally efficient but cost-effective means of strengthening

Page 3: Strengthening of Steel Girder Bridges Using Fiber

Primary ObjectivesPrimary ObjectivesPrimary Objectives

Investigate the effectiveness of FRP composite materials in strengthening of deteriorated steel girder bridges

Identify changes in structural behavior due to addition of strengthening system

Page 4: Strengthening of Steel Girder Bridges Using Fiber

Two Strengthening SchemesTwo Strengthening SchemesTwo Strengthening Schemes

Strengthening with Carbon Fiber Reinforced Polymer (CFRP) Post-Tensioning Rods

Strengthening with CFRP Plates

Page 5: Strengthening of Steel Girder Bridges Using Fiber

AdvantagesAdvantagesAdvantages

Corrosion resistanceVery light (one tenth of steel)Can be installed with minimal crews and scaffoldingsLoad capacity may be fully restored without exceeding original weight

Page 6: Strengthening of Steel Girder Bridges Using Fiber

Strengthening with CFRP Post-Tensioning RodsStrengthening with CFRP PostStrengthening with CFRP Post--Tensioning RodsTensioning Rods

Page 7: Strengthening of Steel Girder Bridges Using Fiber

Strengthening with CFRP Post-Tensioning (P-T) RodsStrengthening with CFRP PostStrengthening with CFRP Post--Tensioning (PTensioning (P--T) RodsT) Rods

Guthrie County, IAConstructed in 1956210 ft x 26 ft Three-span continuous steel girder bridgeTwo 64 ft End spans & 82 ft Center spanTwo WF 30x116 exterior & two WF 33x141 interior I-beams

Page 8: Strengthening of Steel Girder Bridges Using Fiber

Strengthening with CFRP Post-Tensioning (P-T) RodsStrengthening with CFRP PostStrengthening with CFRP Post--Tensioning (PTensioning (P--T) RodsT) Rods

Page 9: Strengthening of Steel Girder Bridges Using Fiber

Strengthening with CFRP Post-Tensioning (P-T) RodsStrengthening with CFRP PostStrengthening with CFRP Post--Tensioning (PTensioning (P--T) RodsT) Rods

Corroded abutment bearing

Corrosion on steel and spalls on bottom of concrete deck

Page 10: Strengthening of Steel Girder Bridges Using Fiber

Strengthening SystemStrengthening SystemStrengthening SystemPositive moment region of Exterior girders in all three spansDesign force of 12 kips per rod, 48 kips per location (4 rods)

PIER 1 PIER 2

BEAM 1

BEAM 2

BEAM 3

BEAM 4

CFRP ROD

Page 11: Strengthening of Steel Girder Bridges Using Fiber

Strengthening SystemStrengthening SystemStrengthening System

CFRP rods– Outstanding mechanical

characteristics and non-corrosive nature

– 3/8 inch in diameter – Fiber Content : 65 % by

volume– Tensile Strength : 300 ksi– Tensile Modulus : 20,000 ksi

Anchorage assemblies– 5 in. x 5 in. x ¾ in.

stiffened angles– 1 in. couplers– Steel tube anchors

Page 12: Strengthening of Steel Girder Bridges Using Fiber

Installation Process (anchorage assembly)Installation Process (anchorage Installation Process (anchorage assembly)assembly)

Page 13: Strengthening of Steel Girder Bridges Using Fiber

Installation Process (Placing CFRP Rod)Installation Process (Placing Installation Process (Placing CFRP Rod)CFRP Rod)

Placement of CFRP Rod

Top rod placed

Page 14: Strengthening of Steel Girder Bridges Using Fiber

Installation Process (Application of P-T force)Installation Process Installation Process (Application of P(Application of P--T force)T force)

End Span

Center Span

Page 15: Strengthening of Steel Girder Bridges Using Fiber

Completed CFRP P-T System Completed CFRP PCompleted CFRP P--T System T System

End Span (Interior)

Center Span

End Span (Exterior)

Page 16: Strengthening of Steel Girder Bridges Using Fiber

Load Testing & Classic AnalysisLoad Testing & Classic AnalysisLoad Testing & Classic AnalysisTo assess changes in performance due to addition of P-T system and timeTested before & shortly after installation, and one & two years of serviceStandard 3-axle dump trucks used in Load Testing and HS-20 Truck utilized in Classic Beam Analysis

Page 17: Strengthening of Steel Girder Bridges Using Fiber

Monitoring (During P-T)Monitoring (During PMonitoring (During P--T)T)P-T generates strain opposite in sign to those generated by dead and secondary load

-50

-40

-30

-20

-10

0

10

20

30

40

50

0 10 20 30 40 50 60 70 80 90 100

Event

Mic

rost

rain

Beam 1-Top

Beam 1-Bottom

Page 18: Strengthening of Steel Girder Bridges Using Fiber

Monitoring (In service over two year period)Monitoring (In service over two Monitoring (In service over two year period)year period)

Consistency in strain readings over two year period

-80

-60

-40

-20

0

20

40

60

80

100

120

140

0 50 100 150 200 250

Truck Dis tance, ft

Mic

rost

rain

Initial Tes tIm m ediately afterOne-year serviceTwo-year service

Page 19: Strengthening of Steel Girder Bridges Using Fiber

Beam Analysis (LL Moment)Beam Analysis (LL Moment)Beam Analysis (LL Moment)Before P-T

6064 in-kips(Exterior Beam)

4 kips 16 kips16 kips

5672 in-kips(Interior Beam)

100 ft-kips 100 ft-kips

42.2 kips

574 in-kips 371 in-kips(Exterior Beam)

574 in-kips

416 in-kips 268 in-kips(Interior Beam)

416 in-kips

100 ft-kips 100 ft-kips 100 ft-kips 100 ft-kips

42.2 kips 42.2 kips

Due to P-T+++

Page 20: Strengthening of Steel Girder Bridges Using Fiber

Beam Analysis (LL Moment)Beam Analysis (LL Moment)Beam Analysis (LL Moment)

After P-T

100 ft-kips

5693 in-kips(Exterior Beam)

4 kips 16 kips16 kips

5404 in-kips(Interior Beam)

42.2 kips 42.2 kips 42.2 kips

100 ft-kips 100 ft-kips 100 ft-kips 100 ft-kips 100 ft-kips

===

Page 21: Strengthening of Steel Girder Bridges Using Fiber

ConclusionConclusionConclusion

Consistency in strain readings– CFRP P-T system had negligible impact on

changing stiffness of bridge5 to 10 % of Live load moment carrying capacity enhanced

Page 22: Strengthening of Steel Girder Bridges Using Fiber

AcknowledgementAcknowledgementAcknowledgementProject initiated by – Iowa Department of Transportation

(Iowa DOT)Sponsored by – Federal Highway Administration

(FHWA) through the Innovative Bridge Research and Construction (IBRC) program