submersible pump 4” dmd-p seriesatsengg.com/attachments/products/dmd series.pdf · submersible...
TRANSCRIPT
Submersible Pump4” DMD-P Series
Alarko submersible pumpsare pumps that are always ready to use in usage and drinking water areas, problem-free, paying their investment
in a short time. THE ONLY UNINTERRUPTIBLE, PERSONAL WATER SOURCEWith its high efficiency and long life in industrial facility and establishments for providing
process and usage water A SUITABLE INVESTMENT.Especially in tourism season in touristic facilities
where water is needed more than ever, THE ONLY RELIABLE WATER SOURCE.
Superior thanks to their additional use as a waterbooster for storage of usage water of various purposed in all kinds of buildings from separate houses to skyscrapers, and thus they
are VERY FUNCTIONALFor gardening and agriculture; irrigating a small house garden or tens of thousands of acres of agricultural areas for gardeners and farmers makes Alarko submersible pumps A RELIABLE FRIEND.With its superior technology, economy, constant and quality service, fast spare part supply system, it is unrivaled.
Submersible pump is your biggest helper
when present resources are inadequate and ground
waters should be extracted. It is unrivaled, problem-free and
economic in supplying drinking and usage waters. It is robust and long-lived
Especially in tourism season, in touristic facilities where water is needed more than ever, it helps the problem
of water be remedied in cases where city main is inadequate.
It is the most suitable solution for well water use in buildings, and car wash stations It is farmer and producer’s biggest friend in irrigation of
garden and agricultural areas. It overcomes water-problem and drought, and brings life to the soil and abundance to the produce. Alarko Diamond submersible pumps meet all your needs with 5 type, 43 models and high-reliability components
with a capacity interval of 0,5-18 m3/hour.
Suction Case:
Durability and pump life is extended against aggressive well waters by Cu ASTM280 material with high corrosion resistance.
Valve Table and Bearing:
Durability and pump life is extended against aggressive well waters by “Fiberglas Reinforces Thermoplastic” material with high corrosion resistance.
Impellers:
Pump life and efficiency is increased with “Acetal” material with low surface roughness, and durable against sand abrasion. It is designed with floating fan against sand jamming.
Diffuser and Impeller Cover:
The stainless bearing fitted over the diffuser and diffuser cap provides high abrasion strength. It is manufactured from polycarbonate material.
GENERAL PUMP CURVES
ELECTRICAL FEATURES, DIMENSIONS AND WEIGHTS
96
B
A
Nominal Current Total Dimension (A) Approximate (mm)
220 V 380 V 220 V 380 V
Total Weight Approximate (Kg)
220 V 380 V
811162228385062
579
131724324050
579
121521283644
57
1014182228
57
11151923
0,50,75
11,5234
5,5
0,50,75
11,5234
5,57,5
0,50,75
11,5234
5,57,5
11,5234
5,57,5
1,5234
5,57,5
3,54,668
10,515--
3,54,668
10,515---
3,54,668
10,515---
68
10,515---
810,515---
1,62
2,73,44,36,38,5
10,3
1,62
2,73,44,36,38,5
10,312,3
1,62
2,73,44,36,38,5
10,312,3
2,73,44,36,38,5
10,312,3
3,44,36,38,5
10,312,3
741831985
117514061749
682754840993
11561479
726807903
104211901513
797913
10781323
88910371324
741831970
1.1551.3711.7092.0582.454
682754825973
1.1211.4391.7152.0062.416
726807888
102211551473175320822473
691893
10431283151717352060
86910021284156018202111
10,411,914,417,721,328,3
10,211,413,316,119,425,8
10,411,713,616,219,325,5
12,715,118,123,8
15,418,424,4
10,111,513,416,519,426,131,637,7
9,911
12,314,917,523,628,333,740,4
10,111,312,615
17,423,327,833,239,5
11,713,916,221,625,329,735,5
14,216,522,226,230,936,4
4002DMD-P
4004DMD-P
4006DMD-P
4010DMD-P
4012DMD-P
Pipe Thread ISO
228-G1 ¼
Pipe Thread ISO
228-G1 ¼
Pipe Thread ISO
228-G1 ½
Pipe Thread ISO
228-G2
Pipe Thread ISO
228-G2
Numberof Stages
Pump Exit Diameter
Motor Power(HP)
PumpType
“General Selection Chart” is used to determine the pump type zone that the intersection of the desired flow rate and manometric height (A) remains in.
If the well diameter is 6”, flow rate (Q) is 3 m3/hour and manometric height (H) is 75 mWc; on “Pump General Curves” the 3 m3/hour on the horizontal axis and 75 mWc points on the vertical axis are intersected.
The intersection point (A) remains inside the 4004 type pump zone. From here, the 4004 type pump “Independent Characteristic Curve” is consulted.
3 m3/hour and 75 mWc point intersection point is on the 13th stage curve. Pump stage is selected as 13.
“Electrical Characteristics, Dimensions and Weights Table” shows the pump motor power as 1,1 kW. Order notation is determined as 4004/13 DMD-P+1,1 kW
4004
DM
D-P
H (m
Wc)
500
450
400
350
300
250
200
150
100
50
0Eta (%)
60
40
20
00
0 1 2 3 4 5 6
10 20 30 40 50 60 70 80 90 100
1500
feet
1350
1200
1050
900
750
600
450
300
150
0
I/min
m3/h
US g.p.m
Imp g.p.m0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25
0 2.5 5 7.5 10 12.5 15 17.5 20
4004 / 50
4004 / 40
4004 / 32
4004 / 24
4004 / 17
4004 / 13
4004 / 94004 / 74004 / 5
A
Pump Type
Numberof Stages
Motor Power (HP)
Nominal Current(A)
Total Dimension Approximate (mm)
Total Weight Approximate (Kg) Pump Exit
Diameter
220 V 380 V 220 V 380 V 220 V 380 V
4002DMD-P
8 0,5 3,5 1,6 741 741 10,4 10,1
Pipe Thread ISO228-G1 ¼
11 0,75 4,6 2 831 831 11,9 11,5
16 1 6 2,7 985 970 14,4 13,4
22 1,5 8 3,4 1175 1.155 17,7 16,5
28 2 10,5 4,3 1406 1.371 21,3 19,4
38 3 15 6,3 1749 1.709 28,3 26,1
50 4 - 8,5 2.058 31,6
62 5,5 - 10,3 2.454 37,7
4004DMD-P
5 0,5 3,5 1,6 682 682 10,2 9,9
Pipe Thread ISO228-G1 ¼
7 0,75 4,6 2 754 754 11,4 11
9 1 6 2,7 840 825 13,3 12,3
13 1,5 8 3,4 993 973 16,1 14,9
17 2 10,5 4,3 1156 1.121 19,4 17,5
24 3 15 6,3 1479 1.439 25,8 23,6
32 4 - 8,5 1.715 28,3
40 5,5 - 10,3 2.006 33,7
50 7,5 - 12,3 2.416 40,4
4006DMD-P
5 0,5 3,5 1,6 726 726 10,4 10,1
Pipe Thread ISO228-G1 ½
7 0,75 4,6 2 807 807 11,7 11,3
9 1 6 2,7 903 888 13,6 12,6
12 1,5 8 3,4 1042 1022 16,2 15
15 2 10,5 4,3 1190 1155 19,3 17,4
21 3 15 6,3 1513 1473 25,5 23,3
28 4 - 8,5 1753 27,8
36 5,5 - 10,3 2082 33,2
44 7,5 - 12,3 2473 39,5
4010DMD-P
5 1 6 2,7 797 691 12,7 11,7
Pipe Thread ISO228-G
2
7 1,5 8 3,4 913 893 15,1 13,9
10 2 10,5 4,3 1078 1043 18,1 16,2
14 3 15 6,3 1323 1283 23,8 21,6
18 4 - 8,5 1517 25,3
22 5,5 - 10,3 1735 29,7
28 7,5 - 12,3 2060 35,5
4012DMD-P
5 1,5 8 3,4 889 869 15,4 14,2
Pipe Thread ISO228-G
2
7 2 10,5 4,3 1037 1002 18,4 16,5
11 3 15 6,3 1324 1284 24,4 22,2
15 4 - 8,5 1560 26,2
19 5,5 - 10,3 1820 30,9
23 7,5 - 12,3 2111 36,4
PERFORMANS TABLOSU (50Hz)
-
-
Q (m3/h)
H (m
Wc)
l/min
Eta(%)
0
0
00
20
40
60
50
100
150
200
250
300
350
400
450
500
5 10 15 20 25 30 35 40 45 50 55
0.5 1 1.5 2 2.5 3
H (m)
3m /hl/min
P2MODEL
00
1~220V/240V KW HP n
3~380V/415V
n 2850≈ 1/min
4002/28
4002/38
4002/50
4002/62
4002/22
4002/16
4002/11
4002/8
3 4
4 5.5
0.37 0.54002/8 DMD-P
0.55 0.754002/11 DMD-P
0.75 14002/16 DMD-P1.1 1.54002/22 DMD-P1.5 24002/28 DMD-P2.2 34002/38 DMD-P
4002/50 DMD-P
4002/62 DMD-P
4002/8 DMD-P4002/11 DMD-P
4002/16 DMD-P4002/22 DMD-P4002/28 DMD-P4002/38 DMD-P
5880116160204276364451
0.355879116159202275361448
1.830506899136173235310384
0.6105778114157200271356442
0.9155677112154196266350434
1.2205475109150191259340422
1.5255272105144183249327406
2.135466392126161218287356
2.440425783114145197260322
2.745365073100127173227282
3.05030426184107145190236
3.3552534506887118155192
4002 DMD-P
PERFORMANCE TABLE (50Hz)
4004 DMD-P
PERFORMANS TABLOSU (50Hz)
Q (m3/h)
H (m
Wc)
l/min
0
0
Eta(%)
0
0
20
40
60
50
100
150
200
250
300
350
400
450
500
10 20 30 40 50 60 70 80 90 100
1 2 3 4 5 6
4004/40
4004/50
4004/32
4004/24
4004/17
4004/13
4004/94004/74004/5
H(m)
1~220V/240V KW HP
P2
m /hl/min
3
n
MODEL
3~380V/415V
n 2850≈ 1/min
4004/5 DMD-P4004/7 DMD-P4004/9 DMD-P4004/13 DMD-P4004/17 DMD-P4004/24 DMD-P
---
4004/5 DMD-P4004/7 DMD-P4004/9 DMD-P4004/13 DMD-P4004/17 DMD-P4004/24 DMD-P4004/32 DMD-P4004/40 DMD-P4004/50 DMD-P
0.370.550.751.11.52.234
5.5
0.50.75
11.5234
5.57.5
00395470101131186247309387
0.61037526797126178238297372
1.22036516594123174231289362
1.83035496391120169225281352
2.44034486188116163218272340
3.05032455783109153204255319
3.66029415376100141188235294
4.2702637486990127170212265
4.8802332415977109145181227
5.490182633486288117147183
6.010014192536466687109137
PERFORMANCE TABLE (50Hz)
4006 DMD-P
PERFORMANS TABLOSU (50Hz)
Q (m3/h)
H (m
Wc)
H (m)
1~220V/240V KW HP
P2
m /hl/min
3
n
MODEL
3~380V/415V
n 2850≈ 1/min
4006/36
4006/44
4006/28
4006/21
4006/15
4006/12
4006/94006/74006/5
4006/5 DMD-P4006/7 DMD-P4006/9 DMD-P4006/12 DMD-P4006/15 DMD-P4006/21 DMD-P
---
4006/5 DMD-P4006/7 DMD-P4006/9 DMD-P4006/12 DMD-P4006/15 DMD-P4006/21 DMD-P4006/28 DMD-P4006/36 DMD-P4006/44 DMD-P
0.370.550.751.11.52.234
5.5
0.50.75
11.5234
5.57.5
003245587797135180232283
1.2203144577594132176226277
2.4402941537088123164210257
3.6602738496581114152195239
4.8802535456075105139179219
6.0100213038516489119153187
7.212016233039496992118145
8.4140111519253244597693
PERFORMANCE TABLE (50Hz)
4012 DMD-P
Q (m3/h)
H (m
Wc)
0
200
Eta(%)
25
50
75
100
125
150
175
0
l/min0 30 60 90 120 150 180 210 240 270
2 4 6 8 10 12 14 16
0
20
40
60
4012/19
4012/15
4012/11
4012/7
4012/5
4012/23
PERFORMANS TABLOSU (50Hz)
1~220V/240V
3~380V/415V
3m /hl/min
MODEL
H(m)
KW HP n
P2 n 2850≈ 1/min
4012/5 DMD-P
4012/7 DMD-P
4012/11 DMD-P
-
-
-
4012/5 DMD-P
4012/7 DMD-P
4012/11 DMD-P
4012/15 DMD-P
4012/19 DMD-P
4012/23 DMD-P
1.1
1.5
2.2
3
4
5.5
1.5
2
3
4
5.5
7.5
0
0
32
45
70
96
121
147
1.8
30
31
43
67
92
116
140
3.6
60
29
40
63
86
109
132
5.4
90
27
37
59
81
102
124
7.2
120
25
34
55
74
94
114
9.0
150
22
31
49
67
85
102
10.8
180
20
28
43
59
75
90
12.6
210
16
23
36
49
62
75
14.4
240
12
18
27
37
47
56
16.2
270
7
10
16
22
28
33
4010 DMD-P
PERFORMANS TABLOSU (50Hz)
Q (m3/h)
H (m
Wc)
P2
m /h
l/min
3
MODEL
3~380V/415V
1~220V/240V
0
25
50
75
100
125
150
175
200
225
0
l/min0 30 60 90 120 150 180 210 2400
2 4 6 8 10 12 14
20
40
60
H(m)
KW HP n
Eta(%)
4010/28
4010/22
4010/18
4010/6
4010/10
4010/14
4010/4
n 2850≈ 1/min
4010/4 DMD-P
4010/7 DMD-P
4010/10 DMD-P
4010/14 DMD-P
-
-
-
4010/4 DMD-P
4010/7 DMD-P
4010/10 DMD-P
4010/14 DMD-P
4010/18 DMD-P
4010/22 DMD-P
4010/28 DMD-P
0.75
1.1
1.5
2.2
3
4
5.5
1
1.5
2
3
4
5.5
7.5
0
0
25
43
62
86
111
136
173
1.8
30
24
42
59
83
107
131
166
3.6
60
23
40
56
79
102
124
158
5.4
90
21
37
54
75
96
118
150
7.2
120
20
35
50
70
90
110
140
9.0
150
18
31
44
62
79
97
124
10.8
180
14
25
36
51
65
80
101
12.6
210
10
18
26
36
47
57
72
14.4
240
6
10
14
20
26
32
40
PERFORMANCE TABLE (50Hz)
4012 DMD-P
Q (m3/h)
H (m
Wc)
0
200
Eta(%)
25
50
75
100
125
150
175
0
l/min0 30 60 90 120 150 180 210 240 270
2 4 6 8 10 12 14 16
0
20
40
60
4012/19
4012/15
4012/11
4012/7
4012/5
4012/23
PERFORMANS TABLOSU (50Hz)
1~220V/240V
3~380V/415V
3m /hl/min
MODEL
H(m)
KW HP n
P2 n 2850≈ 1/min
4012/5 DMD-P
4012/7 DMD-P
4012/11 DMD-P
-
-
-
4012/5 DMD-P
4012/7 DMD-P
4012/11 DMD-P
4012/15 DMD-P
4012/19 DMD-P
4012/23 DMD-P
1.1
1.5
2.2
3
4
5.5
1.5
2
3
4
5.5
7.5
0
0
32
45
70
96
121
147
1.8
30
31
43
67
92
116
140
3.6
60
29
40
63
86
109
132
5.4
90
27
37
59
81
102
124
7.2
120
25
34
55
74
94
114
9.0
150
22
31
49
67
85
102
10.8
180
20
28
43
59
75
90
12.6
210
16
23
36
49
62
75
14.4
240
12
18
27
37
47
56
16.2
270
7
10
16
22
28
33
4010 DMD-P
PERFORMANS TABLOSU (50Hz)
Q (m3/h)
H (m
Wc)
P2
m /h
l/min
3
MODEL
3~380V/415V
1~220V/240V
0
25
50
75
100
125
150
175
200
225
0
l/min0 30 60 90 120 150 180 210 2400
2 4 6 8 10 12 14
20
40
60
H(m)
KW HP n
Eta(%)
4010/28
4010/22
4010/18
4010/6
4010/10
4010/14
4010/4
n 2850≈ 1/min
4010/4 DMD-P
4010/7 DMD-P
4010/10 DMD-P
4010/14 DMD-P
-
-
-
4010/4 DMD-P
4010/7 DMD-P
4010/10 DMD-P
4010/14 DMD-P
4010/18 DMD-P
4010/22 DMD-P
4010/28 DMD-P
0.75
1.1
1.5
2.2
3
4
5.5
1
1.5
2
3
4
5.5
7.5
0
0
25
43
62
86
111
136
173
1.8
30
24
42
59
83
107
131
166
3.6
60
23
40
56
79
102
124
158
5.4
90
21
37
54
75
96
118
150
7.2
120
20
35
50
70
90
110
140
9.0
150
18
31
44
62
79
97
124
10.8
180
14
25
36
51
65
80
101
12.6
210
10
18
26
36
47
57
72
14.4
240
6
10
14
20
26
32
40
PERFORMANCE TABLE (50Hz)
STANDARD ELECTRICAL CONTROL PANEL PARTS
Energy Control Lamp: Displays whether there is power feed to the panel.
Main Switch: Turns on/off the power feed to the panel.
Control Switch: Powers the motor.
Water Level Automat: Controls the pump’s activation/deactivation automatically according to the well water level. Prevents the pump from operating without water. Water level servo is a set with level control electrodes and electrode cable assembly.
Phase (Motor) Control Relay and Warning Lamp: Prevents the three-phase motors from being left with two phases. It also provides protection by stopping the pump in phase instabilities in the power main.
Fuses: Protection against short circuit.
Thermal Relay: Protection against excessive load
Warning Lamps: “Malfunction”, ”Operation”, “Well Without Water” lamps. Enables easy monitoring of the pump operation
Amperometer and Voltmeter: Current and voltage values can be measured. (Optional)
Technical SpecificationsOperation Voltage Gerilim 3~380 V 1~220 V
Permissible Maximum Voltage Change -10.....+10 % + %5,-%10
Frequency 50 Hz
Pump Type 4002 / 4004 / 4006 / 4010 / 4012
Motor RPM 2850 Rev / Min
Permissible Maximum Starts per Hour 30
Maximum Well Water Temperature 40ºC
Electrical Cable Selection Chart
NOMINALVOLTAGE
Motor Power Cable Section (mm2)M
axim
um C
able
Len
gth
(m)
kW HP 1.5 2.5 4 6 10 16
MONOPHASE220 V
0,37 0,5 71 118 190 285 495 776
0,55 0,75 55 92 149 223 386 604
0,75 1 45 74 120 179 308 479
1,1 1,5 30 50 81 121 209 325
1,5 2 24 40 64 96 166 259
TRIPHASE380 V
0,37 0,5 479 796 - - - -
0,55 0,75 352 586 940 - - -
0,75 1 267 325 713 1064 - -
1,1 1,5 196 244 522 779 - -
1,5 2 147 173 392 585 1000 -
2,2 3 104 126 277 413 707 1090
3 4,0 76 99 203 302 518 798
4 5,5 59 87 159 237 406 626
4,4 6 21 104 139 207 355 548
5,5 7,5 41 69 110 165 283 437
7,5 10 - 50 81 121 207 320
1- CASING:It is on the upper part of the pump. Pump exit connection is made here. It is manufactured from Bronze material (Cu ASTM 280)
2- CHECK VALVE:It is inside the valve body. Prevents the return of the pumped water.
3- BODY PIPE:It holds together the pump stages that are stacked between the suction mouth and valve body. It is manufactured from AISI 304 stainless steel material.
4- BEARING BODY:Centralizes the pump shaft through the bearings.
5- PUMP SHAFT:It is fixed to the motor shaft through special coupling. It is of hexagon type, made of AISI 304 stainless steel material.
6- DIFFUSER:Enables the water to be transferred suitably between stages. It is manufactured from polycarbonate material.
7- IMPELLER:There is one fan in every stage. It is designed with floating impeller against sand jamming. It is manufactured from acetal material.
8- SUCTION STAINER:Prevents entrance of particles of size that can damage the pump.
9- SUCTION CASE:Enables the pump and motor to be connected to each other. Water enters the pump through the suction opening. It has a suction filter that prevents large particles from entering. It is manufactured from Bronze material (Cu ASTM 280)
10- COUPLING:Connects the pump and motor shaft, manufactured from AISI 304 or AISI 315 stainless steel material.
11- ELECTRICAL CABLE:Special underwater electrical cable. Has number of lines and cross section suitable for the motor.
12- MOTOR:Manufactured suitably for operating underwater. The bearings that carry radial and axial loads are lubricated and cooled with the special liquid filled inside the motor. Motor is started directly.
4
1
2
3
5
6
7
9
8
10
11
12
MAIN PARTS / STANDARD CONSTRUCTION
4002 / 4004 / 4006 / 4010 / 4012 DMD-P Models
ALARKO CARRIERSANAYİ VE TİCARET A.Ș.
The right to amend specifications under technologic developments is reserved
GOSB-Gebze Organize Sanayi Bölgesi
Șahabettin Bilgisu Cad. 41480 Gebze-Kocaeli/TURKEY
Phone : (90)(262) 648 60 00 PBX
Telefax : (90)(262) 648 61 01
web : www.alarko-carrier.com.tr
e-mail : [email protected]
FOR SECURE AND EFFICIENT USE
• The well water temperature and the amount of sand in the well water must be analyzed in a laboratory. The maximum sand amount in the well water must be 25 gr/m3, and maximum well water temperature must be 40˚C.
• Pipes and pipe clamps must have enough strength to carry the pump group, the water in the vertical pipe and its own weight.
• It is recommended that thee well diameter is at least 2” (inches) larger than the pump diameter.
• The distance between the pump suction filter and well filter must have maximum distance.
• The lower end of the motor and the well bottom must be at least 50 cm apart. The height of the pump descending into the well is determined accordingly.
• The assembly depth of the pump is the Net Positive Suction Height which is the minimum depth that the pump can operate without sucking air. Must be suitable to (NPSH) values.
D.1.
1.14
i 060
115
MiN
ERAL
Suction Stainer
Application Methods
Placing within a Wide Well Placing within a Normal Well Placing within a Large Well
Electrical Cable
Cable Clamp
Check Valve
Pump
Motor
Cobblestone
ORDER NOTATION
4004 / 13 + 1.5HP - T. 30Electrical Cable Length (m)
T: There is an electrical control panel.
Y: There is no electrical control panel.
Motor Power
Number of Stages
Pump Type
A
Delivery Pipe
Manometer
Electrode
50 cm
H
Electrical Cable
Cable Clamp
Suction Stainer
Cobblestone
Check Valve
Pump
Motor
Manometer
Ventilation
Ventilation
Well Opening Flange
Protective Pipe
Delivery Pipe Delivery Pipe
Electrical Cable
Cable Clamp
Check Valve
Pump
Suction Stainer
Motor
Filter
Electrode
300
cmH
cm
PowerCord
Control panel
Valve
Valve
Manometer Connection
Profile
Well Cover
Entry Cover
Cable Shall be Knotted
DETAIL-A
H= 0,3 m (if B+9>NPSH)H= NPSH-(B+9) (if B+9<NPSH)B: Pump height
WARRANTY