submission form intertek
TRANSCRIPT
-
8/20/2019 Submission Form Intertek
1/26
FEE SCHEDULE
Intertek
Minerals
INDONESIA
Accreditation LaboratoryLP-130-IDN
March 2009
-
8/20/2019 Submission Form Intertek
2/26
-
8/20/2019 Submission Form Intertek
3/26
1
Index of Services
Our Mission ....................................................................................................................... 2
About Intertek.....................................................................................................................2-3
Sample Preparation ........................................................................................................... 4-6
Precious Metals ................................................................................................................. 7-8
Geochemical Analysis by AAS .......................................................................................... 9
Geochemical Analysis by ICP ........................................................................................... 10
Fusion Analysis by XRF .................................................................................................... 11-12
Geochemical Analysis by XRF.......................................................................................... 12
Miscellaneous Analysis ..................................................................................................... 12
General Terms & Conditions ............................................................................................ 13-16
Contacts & Addresses ....................................................................................................... 17
Sample Shipping................................................................................................................. 18
Sample Submission Form .................................................................................................. 19
Conversion Tables ............................................................................................................. 20-22
-
8/20/2019 Submission Form Intertek
4/26
-
8/20/2019 Submission Form Intertek
5/26
3
PD02
INTERTEK INDONESIA: Intertek, represented by PT Intertek Utama Services, has been providing analytical services inIndonesia since 1993.
In addition to operating one of South East Asia’s largest commercial analytical laboratories in Jakarta, encompassing minerals,
environmental, petroleum geochemistry and palm oil testing, Intertek operates sample preparation facilities throughout the
region.
Currently, the Company has sample preparation facilities in Medan, Padang, Manado and Sumbawa Besar in Indonesia, Manilaand Surigao in the Philippines and Lae, Papua New Guinea. Whilst these facilities offer services to all clients, Intertek also
operates dedicated sample preparation sites for specific clients in both Indonesia and PNG. Fire Assay Gold is also available in
Lae, PNG.
Utilising its depth of expatriate and national staff, Intertek also provides 24 /7 mine site laboratory operations for the Newcrest
Gosowong gold mine and Newmont Batu Hijau copper/gold mine.
Analytical services are offered to clients from Saudi Arabia and the Middle East to Thailand, Laos, China, Vietnam, Philippines,
Malaysia, Indonesia, Papua New Guinea and Australia.
QUALITY ASSURANCE AND SAMPLE TRACKING: Our Jakarta laboratories hold ISO 17025 accreditation for their minerals,
environmental and petroleum analyses whilst the Company is accredited by FOSFA for palm oil testing.
The ISO 17025 accreditation ensures international standards are maintained in the laboratories’ procedures, methodology,
validation, QA/QC, reporting and record keeping. A sophisticated Laboratory Information Management System (LIMS) is
in place for sample tracking, scheduling, quality control and electronic reporting. This is complemented by bar coding of
samples in the Jakarta laboratories.
Certified Reference Materials, blanks, splits and replicates are analysed with each batch of samples. Selected samples are also
re-analysed to confirm anomalous results. These quality control results are reported along with the sample values in the final
reports. Intertek also participates in a number of regular international proficiency round robins and client specific proficiency
programs.
REFINERY REPRESENTATION: Intertek offers a team of trained superintendents to minimize client risk by the supervision
of precious metal refinery evaluation smelts and export shipments. Our staff will reduce the risk of melt losses and sampling bias
by strictly monitoring the smelting process. This includes receipt of material, equipment use, clean up and product handover.
ENVIRONMENTAL SERVICES DIVISION: Intertek’s environmental division provides laboratory testing services as well as
environmental consulting services to numerous industries in Indonesia (mining, oil & gas, manufacturing and utilities).
These services include trace level testing of water, soil, sediment, air and biological tissue in addition to testing more complex
samples such as wastewater and solid waste. Our consulting services support environmental studies which must be conducted
by our clients (e.g. AMDAL, RKL/RPL, EBS, for their development plans).
Additional services include the provision of technicians for collection of samples in the field. Sample collection containers,
preservatives and coolers are shipped to most locations throughout Indonesia.
PETROLEUM SERVICES DIVISION: Based in Jakarta and also using the extensive capabilities of its Singapore and Malaysian
laboratories, Intertek offers a range of sampling, onsite and laboratory analyses for Oil and Gas clients.
These services include; gas composition analyses, source rock screening, bitumen and oil composition analyses, trace ele-
ments, machinery lubrication analysis and interpretation, on-site mercury analyses and gas cylinder rental.
Intertek technicians conduct onshore and offshore sampling, conducting analyses at site or returning to the Jakarta laboratory
with samples for analysis.
COAL SERVICES DIVISION: Intertek has two coal laboratories in Samarinda and Banjarbaru, offering inspection and testing
services such as proximate and ultimate analysis.
-
8/20/2019 Submission Form Intertek
6/26
4
Sample PreparationC orrect sample preparation procedures are best selected through consultation with laboratory management prior to sample
submission.
The schemes listed below are a guide only as the choice of procedure will depend on the sample mineralogy, equipment utilized,
time constraints and client budget.
In general, two schemes are offered, Total Preparation and Partial Preparation.
Total Preparation
The entire sample is dried, crushed and fine pulverized. Large samples will require multi-bowl pulverizing, after which the sample
is recombined before the assay pulp is taken.
Partial Preparation
The sample is dried and crushed before a split is taken for fine pulverizing. The size of the split and whether it is taken manually
(Riffle) or mechanically (Rotary Sample Divider) will depend on the client’s requirements and equipment in use.
General Information
Standard drying temperature is set at 105oC but samples may be dried at 60oC if mercury is to be analysed.
Samples may also be roasted to remove sulphides and other interferents before fire assay.
Intertek nominates 95% passing specific sieve sizes for crushing and pulverizing, however, the ability to achieve these percent-
ages will depend on the sample size and mineralogy and the equipment in use at a particular Intertek facility.
Quality control procedures include a 1 in 15 resplit after crushing or pulverising for partial preparation and after pulverizing for
total preparation. These samples are analysed and reported to the client. Also sizing tests are carried out on 1 in 20 assay pulps
at 75um (200#) to monitor the pulverising stage. These values are available to be reported, on request.
It is standard Intertek practice that all crushers and pulverisers are cleaned with barren material and/or bowl washing between
each sample to minimize carry-over contamination.
Sample Storage
Sample residues and pulps will be stored without charge for three months, after which the client will be contacted with the choice
of samples being returned, discarded or stored for a fee.
Sample Waste Disposal
Intertek disposes of its chemical and hazardous wastes ethically and using qualified disposal contractors. A sample disposal
charge of US$0.20 is applied to all samples submitted. This charge is not subject to discount.
-
8/20/2019 Submission Form Intertek
7/26
5
Sample Preparation
PD02
US$ Code
Drying
Additional weight $0.30/kg/sample
(60oC) up to 2kg $1.65/sample
Additional weight $0.55/kg/sample
Crushing
Additional weight $0.55/kg/sample
Splitting (Riffle)
Fine Pulverising
Sieving
more than one fraction $0.50/kg/extra faction
Wet sieve $1.50/kg/fraction
Roasting
Compositing/Homogenising
Sample weights
Pan Con Preparation
Miscellaneous
Standards Intertek can prepare client specific standards. P.O.A.
Please consult the Laboratory Management for detail.
Additional weight $0.55/kg/sample
Splitting Rotary
Additional weight $0.65/kg/sample
(105oC) up to 2kg $1.10/sample
75%
-
8/20/2019 Submission Form Intertek
8/26
6
PD02
US$ Code
Dry (105oC), Crush (95%
-
8/20/2019 Submission Form Intertek
9/26
7
PD02
I ntertek offers a range of analyses for precious metals; gold, platinum and palladium.
Fire Assay schemes involve fusing the sample with a litharge based flux and collecting the precious metals in a lead button. After
cupellation the resulting prill is dissolved in aqua regia and the gold is determined by AAS for routine samples. Samplesexceeding the upper limits of the method are automatically re-assayed utilising a high grade gravimetric method.
Alternatively, for low level samples, graphite tube atomization via AAS may be used for gold, platinum and palladium
determinations.
Samples with sulphide or base metal matrices may be roasted or have the flux mixture changed to accommodate the matrix.
FA30
30g of sample is analysed. This scheme is suitable for higher concentration samples, those generated in ore body definition
drilling and samples with a sulphide and/or copper matrix. Detection Limit (DL) 0.01ppm, Upper Limit (UL) 30ppm.
FA50
50g of sample is analysed. This scheme is suitable for exploration samples when the identification of anomalous samples is
important. DL 0.005ppm, UL 50ppm. A recommended option for grassroots exploration is the use of a new fire assay pot for each
sample.
FA51
50g of sample is analysed. This scheme is recommended for routine samples that are not subject to any matrix issues nor
particularly low or high concentrations. DL 0.01ppm, UL 50ppm.
FA10 and FA12
A gravimetric finish is used for samples exceeding the upper limits of the routine methods or for known high concentration
samples.
FA55
For low level exploration samples where 50g is analysed and a graphite tube atomisation finish is employed to give low
detection limits. Platinum and palladium can also be determined as additional elements. D.L Au (1ppb), Pt (5ppb), Pd (1ppb).
FA20
Screen fire assay is used to identify coarse gold and typically involves sieving 1 kilogram of sample at 75um (200#). The entire
oversize and duplicate undersize samples are fired and the weighted average is calculated and reported.
Cyanide Leachable Gold
Cyanide soluble gold is determined by leaching the sample in a dilute cyanide solution.
High Grade Bottle Roll methods are used for ore grade samples and leach conditions can be customised to client requirements.
Additional optional information includes stages pH and cyanide levels, total cyanide consumption along with tail recovery and
analysis. Accelerated leaching using Leachwell is also available.
BLEGS are a low level exploration method commonly used for stream sediment samples to identify low value anomolies.
Two techniques are offered, standard leach and GTA finish or a zinc collection method (based on the Merril Crowe technique)
Copper and silver may be determined as additional elements..
Precious Metals
-
8/20/2019 Submission Form Intertek
10/26
8
Precious Metals
AAS - Atomic Absorption (routine and ore grade technique)
FA30FA50
FA51
Au > 30/ 50ppm will be automatically re-assayed by method FA10/FA12 unl es s otherwise advised by the client
Au 0.005 - 50.0ppm 50g $9.50
GTA - Graphite Tube Atomiser (low level exploration technique)
FA55
$4.25 additional element
Au 1ppb Pt 5ppb Pd 1ppb 50g $13.00 first element
Gravimetric (high grade technique)
FA10
FA12
Au 6ppm - max. 30g $12.00
Au 3ppm - max. 50g $13.00
BLEG (GTA) (low level exploration technique - bottle roll)
CN02CN03
Au 0.1 - 25ppb
-
8/20/2019 Submission Form Intertek
11/26
-
8/20/2019 Submission Form Intertek
12/26
10
Geochemical Analysis by ICPAqua regia (3:1 HCl:HNO
3) digestion is a mixture of hydrochloric and nitric acids. Most sulphide minerals are readily dissolved
but silicates, aluminates and many other minerals are only slightly digested. Samples exceeding upper limits can be re-assayed
by a suitable ore grade method if required.
IC01*
Bi (2ppm-2 000ppm) Ca (0.01%-10.0%) Cd (0.2ppm-2 000ppm) Co (1ppm-10 000ppm) Digest + first element $7.35
Cr (1ppm-10 000ppm) Cu (1ppm-10 000ppm) Fe (0.01%-10.0%) Ga (2ppm-2 000ppm) Additional element $0.35
K (0.01%-10.0%) La (1ppm-2 000ppm) Li (1ppm-10 000ppm) Mg (0.01%-10.0%)
Mn (1ppm-20 000ppm) Mo (1ppm-20 000ppm) Na (0.01%-5.0%) Nb (1ppm-10 000ppm)
Ni (1ppm-10 000ppm) Pb (2ppm-10 000ppm) Sb (1ppm-2 000ppm) Se (5ppm-2 000ppm)
Sc (1ppm-2 000ppm) Sn (5ppm-2 000ppm) Sr (1ppm-2 000ppm) Ta (5ppm-1 000ppm)
US$ Code
Ag (0.1ppm-200ppm) Al (0.01%-10.0%) As (2ppm-10 000ppm) Ba (1ppm-2 000ppm) $13.70 all elements
Te (5ppm-2 000ppm) Ti (0.01%-5.0%) V (1ppm-10 000ppm) W (10ppm-2 000ppm)
Y (1ppm-2 000ppm) Zn (1ppm-10 000ppm) Zr (1ppm-5 000ppm) Additional elements available, on requested
M ulti acid digestion (HCl/HNO3/HClO4/HF) is the most aggressive digest offered, specifically designed for elements locked ina silicate/quartz matrix. Also includes an accurate volumetric finish. Solubility and upper limits are mineral dependent.
IC50
Bi (5ppm) Ca (0.01%) Cd (1ppm) Co (2ppm) Digest + first element $9.50
Cr (2ppm) Cu (2ppm) Fe (0.01%) Ga (10ppm) Additional element $0.50
K (0.01%) La (1ppm) Li (1ppm) Mg (0.01%)
Mn (2ppm) Mo (1ppm) Na (0.01%) Nb (5ppm)
Ni (5ppm) Pb (2ppm) Sb (5ppm) Sc (2ppm)
Sn (10ppm) Sr (1ppm) S (50ppm) Ta (5ppm)
Ag (0.5ppm) Al (0.01%) As (5ppm) Ba (2ppm) $16.50 all elements
Te (10ppm) Ti (0.01%) V (1ppm) W (10ppm)
Y (1ppm) Zn (2ppm) Zr (5ppm)
* Over range elements can be analysed by appropriate one grade method on request.
T riple acid digestion (HCl/HNO3/HClO
4) is the preferred ore grade digest followed by an accurate volumetric finish to enable
high concentrations of elements to be analysed. Limitations with silicates. Solubility and upper limits are mineral dependent.
IC30
Bi (5ppm) Ca (0.01%) Cd (1ppm) Co (2ppm) Digest + first element $8.95
Cr (2ppm) Cu (2ppm) Fe (0.01%) Ga (10ppm) Additional element $0.50
K (0.01%) La (1ppm) Li (1ppm) Mg (0.01%)
Mn (2ppm) Mo (1ppm) Na (0.01%) Nb (5ppm)
Ni (5ppm) Pb (2ppm) Sb (5ppm) Sc (2ppm)
Sn (10ppm) Sr (1ppm) S (50ppm) Ta (5ppm)
Ag (0.5ppm) Al (0.01%) As (5ppm) Ba (2ppm) $16.50 all elements
Te (10ppm) Ti (0.01%) V (1ppm) W (10ppm)
Y (1ppm) Zn (2ppm) Zr (5ppm)
-
8/20/2019 Submission Form Intertek
13/26
11
Fusion Analysis by XRFX -ray fluorescence (XRF) is an instrumental method of analysis in which a sample, pressed into a pellet or fused into a disc, is
introduced into an X-ray beam. The sample is fused with a borate flux, the fusion process breaks down the sample matrix
completely thus the results obtained are “total”.
Whole Rock SuiteXR80
XR80L
Al2O3 (0.01%-100%) CaO (0.01%-100%) Cr2O3 (0.01%-100%) Fe2O3 (0.01%-100%) $20.00 all elements
K 2O (0.01%-100%) MgO (0.01%-100%) MnO (0.01%-100%) Na2O (0.01%-100%) Fusion + first element $16.00
P2O5 (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%) Extra element $1.00
Suite including LOI $23.00 / sample
US$ Code
Nickel Laterite Suite
XR81
XR81L
Al2O3 (0.01%-100%) CaO (0.01%-100%) Cl (0.01%-2.00%) Co (0.001%-5.00%) $22.00 all elements
Cu (0.002%-2.00%) Cr2O3 (0.01%-100%) Fe2O3 (0.01%-100%) K 2O (0.01%-100%) Fusion + first element $16.00
MgO (0.01%-100%) MnO (0.01%-100%) Na2O (0.01%-100%) Ni (0.01%-40.0%) Extra element $1.00
P2O5 (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%) Zn (0.002%-40.0%)
Suite including LOI $25.00 / sample
Iron Ore / Sands SuiteXR20
XR20L
Al2O3 (0.01%-100%) As (0.002%-40.0%) BaO (0.01%-100%) CaO (0.01%-100%) $30.00 all elements
Cl (0.005%-8.00%) Co (0.01%-40.0%) Cr2O3 (0.01%-100%) Cu (0.002%-40.0%) Fusion + first element $25.00
Fe2O3 (0.01%-100%) Total Fe(0.01%-100%) K 2O (0.01%-100%) MgO (0.01%-100%) Extra element $1.00
Suite including LOI (2 temp or 4 temp) $33.00 / sample
MnO (0.01%-100%) Na2O (0.01%-100%) Ni (0.01%-40.0%) Pb (0.002%-40.0%)
P2O5 (0.01%-100%) S (0.01%-100%) SiO2 (0.01%-100%) Sn (0.02%-100%)
TiO2 (0.01%-100%) V2O5 (0.01%-100%) Zn (0.002%-40.0%)
Bauxite SuiteXR30
XR30L
Al2O3 (0.01%-100%) CaO (0.01%-100%) Cr2O3 (0.01%-100%) Fe2O3 (0.01%-100%) $22.00 all elements
K 2O (0.01%-100%) MgO (0.01%-100%) MnO (0.01%-100%) Na2O (0.01%-100%) Fusion + first element $16.00
Suite including LOI $25.00 / sample
P2O5 (0.01%-100%) S (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%)
ZrO2 (0.01%-100%)
Chromite SuiteXR40
XR40L
Al2O3 (0.01%-100%) CaO (0.01%-100%) Cr2O3 (0.01%-100%) Fe2O3 (0.01%-100%) $30.00 all elements
K 2O (0.01%-100%) MgO (0.01%-100%) MnO (0.01%-100%) Na2O (0.01%-100%) Fusion + first element $25.00
P2O5 (0.01%-100%) S (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%) Extra element $1.00
V2O5 (0.01%-100%)
Suite including LOI $33.00 / sample
Manganese SuiteXR50Al2O3 (0.01%-100%) BaO (0.01%-100%) CaO (0.01%-100%) Cr2O3 (0.01%-100%) $25.00 all elements
Cu (0.002%-40.0%) Fe2O3 (0.01%-100%) K 2O (0.01%-100%) MgO (0.01%-100%) Fusion + first element $16.00
MnO (0.01%-100%) Na2O (0.01%-100%) Pb (0.002%-40.0%) P2O5 (0.01%-100%) Extra element $1.00
S (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%) Zn (0.002%-40.0%)
Suite including LOI $28.00 / sample
-
8/20/2019 Submission Form Intertek
14/26
12
Geochemical Analysis by XRFU sed primarily for trace elements the sample is pressed into a disc for introduction to the XRF. Over range results are automati-
cally re-analyzed by XR02.
Pressed Pellet (10grams)XR01
All elements > 10 000ppm will be automatical ly re-assayed by method XR02 unless otherwise advised by client.
As (1ppm-10 000ppm) Ba (10ppm-10 000ppm) Bi (10ppm-10 000ppm) Mo (1ppm-10 000ppm) $4.60 first element
Pb (2ppm-10 000ppm) Sb (1ppm-10 000ppm) Se (4ppm-10 000ppm) Sn (3ppm-10 000ppm) $1.50/ additional element
Ta (4ppm-10 000ppm) Te (5ppm-10 000ppm) Tl (4ppm-10 000ppm) W (5ppm-10 000ppm)
XR02Over range Elements (from method XR01) $5.50 first element
US$ Code
$1.50 / additional element
Miscellaneous Analysis US$ Code
ST01
Acid Insoluble Carbon IR (Leco) $10.00
Insoluble Sulphur SCIS $10.00
NCV Package C, S, SAP, CAP, NCV $18.00
$ 1.50/ additional element
Total Sulphur or Carbon IR (Leco) $ 7.50 first element
Fusion Analysis by XRF
Zircon PackageXR60
XR60L
Al2O3 (0.01%-100%) As (0.002%-40.0%) CaO (0.01%-100%) Cr2O3 (0.01%-100%) $30.00 all elements
Fe2O3 (0.01%-100%) HfO2 (0.01%-100%) K 2O (0.01%-100%) MgO (0.01%-100%) Fusion + first element $25.00
MnO (0.01%-100%) Na2O (0.01%-100%) Pb (0.002%-40.0%) P2O5 (0.01%-100%) Extra element $1.00
S (0.01%-100%) SiO2 (0.01%-100%) TiO2 (0.01%-100%) ZrO2 (0.01%-100%)
Suite including LOI $33.00 / sample
US$ Code
ST62B
ST65
NCV
Shipment and Concentrate Samples P.O.A
-
8/20/2019 Submission Form Intertek
15/26
13
INTERTEK MINERALS SERVICES
TERMS AND CONDITIONS (2009)
1.0 Unless otherwise specifically agreed in writing Intertek Minerals (hereinafter called “the Company”)undertakes services in accordance with these general conditions (hereinafter called “General Conditions”) andaccordingly all offers or tenders of service are made subject to these General Conditions. All resultingcontracts, agreements or other arrangements will in all respects be governed by these General Conditions,
except only to the extent that the law of the place where such arrangements or contracts are made or carried outshall preclude any of the General Conditions and in such case such local law shall prevail wherever, but only tothe extent that, it is at variance with these General Conditions.
1.1 For the purposes of these conditions the term “Intertek Minerals” comprises all of the Intertek
Minerals Subsidiaries including but not limited to Intertek, Intertek Minerals, Intertek MineralsServices, Intertek Robotic Laboratories (IRL), PT Intertek Utama Services (IUS), Intertek TestingServices (ITS), Genalysis Laboratory Services, Intertek Genalysis, Northern Territory Environmental
Laboratories (NTEL), Transworld, McPhar Geoservices (Phils) Inc.
2.0 The Company is an enterprise engaged in the trade of inspection and testing. As such, it:
2.1 carries out such standard services as are referred to in General Condition 6;
2.2 renders advisory and special services as may be agreed by the Company and as referred to in GeneralCondition 7; and
2.3 issues reports and/or certificates as referred to in General Condition 8.
3.0 The Company acts for the persons or bodies from whom the instructions to act have originated (hereinaftercalled "the Principal"). No other party is entitled to give instructions, particularly on the scope of inspection ordelivery of report or certificate, unless so authorised by the Principal and agreed by the Company. TheCompany will however be deemed irrevocably authorised to deliver at its discretion the report or the certificate
to a third party if following instructions by the Principal a promise in this sense had been given to this third party or such a promise implicit follows from circumstances, trade custom, usage or practice.
4.0 The Company will provide services in accordance with:
4.1 the Principal's specific instructions as confirmed by the Company
4.2 the terms of the Company's Standard Order Form, Sample Submission Form and/or Standard
Specification Sheet if used;
4.3 any relevant trade custom, usage or practice; and
4.4 such methods as the Company shall consider appropriate on technical, operational and/or financialgrounds.
5.0
5.1 All enquiries and orders for the supply of services must be accompanied by sufficient informationspecifications and instructions to enable the Company to evaluate and/or perform the servicesrequired.
5.2 Documents reflecting engagements contracted between the Principal and third parties, or third parties'documents, such as copies of contracts of sale, letters of credit, bills of lading, etc., are (if received by
the Company) considered to be for information only, without extending or restricting the mission orobligations accepted by the Company.
General Terms and Conditions
-
8/20/2019 Submission Form Intertek
16/26
14
6.0 The Company's standard services may include all or any of the following:
6.1 quantitative and/or qualitative inspection;
6.2
inspection of goods, plant, equipment, packing, tanks, containers and means of transport;
6.3 inspection of loading or discharging;
6.4 sampling;
6.5 laboratory analysis or other testing; and
6.6 surveys and audits.
7.0 Special services where the same exceed the scope of standard services as referred to in General Condition 6
will only be undertaken by the Company by particular arrangement.
Such special services are illustratively not exhaustively:
7.1 qualitative and/or quantitative guarantees;
7.2 supply of technicians and other personnel;
7.3 pre-shipment inspection under government mandated import or customs schemes; and
7.4 advisory services.
8.0
8.1 Subject to the Principal's instructions as accepted by the Company, the Company will issue reports
and certificates of inspection which reflect statements of opinion made with due care within thelimitation of instructions received but the Company is under no obligation to refer to or reportupon any facts or circumstances which are outside the specific instructions received.
8.2 Reports or certificates issued following testing or analysis of samples contain the Company'sspecific opinion on those samples as received only but do not express any opinion upon the bulk
from which the samples were drawn. If an opinion on the bulk is requested special arrangementsmust be made in advance with the Company for the inspection and sampling of the bulk.
9.0 The Principal will:
9.1 ensure that instructions to the Company and sufficient information are given in due time to enable
the required services to be performed effectively;
9.2 procure all necessary access for the Company's representatives to enable the required services to be performed effectively;
9.3 supply, if required, any special equipment and personnel necessary for the performance of therequired services;
9.4 ensure that all necessary measures are taken for safety and security of working conditions, sitesand installations during the performance of services and will not rely, in this respect, on theCompany's advice whether requested or not;
9.5 take all necessary steps to eliminate or remedy any obstruction to or interruptions in the performance of the required services;
9.6 inform the Company in advance of any known hazards or dangers, actual or potential, associatedwith any order or samples or testing including, for example, presence or risk of radiation, toxic ornoxious or explosive elements or materials, environmental pollution or poisons; and
General Terms and Conditions
-
8/20/2019 Submission Form Intertek
17/26
15
9.7 fully exercise all its rights and discharge all its liabilities under any related contract whether or not areport or certificate has been issued by the Company failing which the Company shall be under no
obligation to the Principal.
10.0 The Company shall be entitled at its discretion to delegate the performance of the whole or any part of the
services contracted for with the Principal to any agent or subcontractor. Where deemed appropriate by thecompany, prior consent will be sought from the Principal.
11.0 If the requirements of the Principal necessitate the analysis of samples by the Principal's or by any third party'slaboratory the Company will pass on the result of the analysis but without responsibility for its accuracy.Likewise where the Company is only able to witness an analysis by the Principal's or by any third party's
laboratory the Company will provide confirmation that the correct sample has been analysed but will nototherwise be responsible for the accuracy of any analysis or results.
12.0
12.1
The Company undertakes to exercise due care and skill in the performance of its services and acceptsresponsibility only where such skill and care is not exercised.
12.2 The liability of the Company in respect of any claims for loss, damage or expense of whatsoevernature and howsoever arising in respect of any breach of contract and/or any failure to exercise due
skill and care by the Company shall in no circumstances exceed a total aggregate sum equal to Fifteen(15) times the amount of the fee or commission paid or payable in respect of the specific service ortest required under the particular contract with the Company which gives rise to such claims, orUS$15,000, whichever is least, provided however that the Company shall have no liability in respect
of any claims for indirect or consequential loss including loss of profit and/or loss of future businessand/or loss of production and/or cancellation of contracts entered into by the Principal. Where the feeor commission payable relates to a number of services and a claim arises in respect of one of thoseservices the fee or commission may be apportioned for the purposes of this paragraph by reference to
the estimated time involved in the performance of each service or the value of the individual services.
12.3 The limit of liability of the Company under the terms of Condition 12.2 may be increased uponrequest received by the Company in advance of the performance of the service to such figure as may
be agreed upon payment of additional fees equal to an appropriate fraction of the increase in such
compensation or as may be agreed upon.
13.0 The Principal shall guarantee, hold harmless and indemnify the Company and its officers, employees, agents orsubcontractors against all claims made by any third party for loss, damage or expense of whatsoever nature andhowsoever arising relating to the performance, purported performance or non-performance of any services tothe extent that the aggregate of any such claims relating to any one service exceed the limit mentioned in
Condition 12.
14.0
Every officer, employee, agent or subcontractor of the Company shall have the benefit of the limitation ocompensation and the indemnity contained in these General Conditions and so far as relates to such limitationsany contract entered into by the Company is entered into not only on its own behalf but also as agent and
trustee for every such person as aforesaid.
15.0 In the event that any unforeseen problems or expenditure arise in the course of carrying out any of thecontracted services the Company shall be entitled to make reasonable additional charges to cover additionaltime and cost necessarily incurred to complete the service.
16.0
16.1 The Principal will punctually pay not later than Thirty (30) days after the relevant invoice date or uponreceipt of invoice where credit is not extended or a credit limit is exceeded or within such other period
as may have been agreed in writing by the Company all proper charges rendered by the Companyfailing which interest will become due at the rate of Eighteen per cent (18%) per annum or one and ahalf percent (1.5%) from the date of invoice until payment.
General Terms and Conditions
-
8/20/2019 Submission Form Intertek
18/26
16
16.2 The Principal shall not be entitled to retain or defer payment of any sums due to the Company onaccount of any dispute, cross claim or set off which it may allege against the Company.
16.3 In the event of any suspension of payment arrangement with creditors, bankruptcy, insolvency,
receivership or cessation of business by the Principal the Company shall be entitled to suspend allfurther performance of its services forthwith and without liability.
17.0 In the event of the Company being prevented by reason of any cause whatsoever outside the Company'scontrol from performing or completing any service for which an order has been given or an agreementmade, the Principal will pay to the Company:
17.1 the amount of all abortive expenditure actually made or incurred; and
17.2 a proportion of the agreed fee or commission equal to the proportion (if any) of the serviceactually carried out and the Company shall be relieved of all responsibility whatsoever for the
partial or total non-performance of the required service.
18.0
The Company shall be discharged from all liability to the Principal for all claims for loss, damage orexpense unless suit is brought within twelve (12) months after the date of the performance by the Companyof the service which gives rise to the claim or in the event of any alleged non-performance within three (3)months of the date when such service should have been completed.
19.0 The Company is neither an insurer nor a guarantor and disclaims all liability in such capacity. Principalsseeking a guarantee against loss or damage should obtain appropriate insurance.
20.0 No alteration, amendment or waiver of any of these General Conditions shall have any effect unless madein writing and signed by an officer of the Company.
21.0 Upon completion of testing the company shall provide a report to the principal on the results of the testing.
Where requested by the Principal provisional results may be provided however the Principal agrees thatthose results shall be subject to confirmation in a final report.
22.0 The company agrees to take reasonable measures to ensure that the results of Inspection or Testing on behalf of the Principal and any other information provided to the company are kept confidential provided
that this provision will not apply where the results or other information are in the public domain.
23.0 All samples submitted to the company remain the property of the principal. The company shall not be liablefor any claim whatsoever relating to deterioration, contamination, damage or loss of samples. The Principalagrees to indemnify the Company in respect to all claims, demands or actions which may be made against
the company with respect to deterioration, damage or loss of samples.
24.0 The Company shall have no responsibility for any action or inaction of any carrier, shipping or delivering
any sample to or from the Company premises.
25.0 Samples shall be stored free of charge for a period of sixty (60) days after provision of the invoice. Uponexpiration of the free storage period, unless otherwise directed by the Principal storage fees and/or disposal
charges shall apply.
26.0 All data will be retained for a seven (7) year period; fees may apply for retrieval of data if longer than three(3) months after the final report date.
Charges
Listed fees are for routine turnaround sample types. A premium may apply for rush service. An Administration charge of US$25.00
applies to each submission.
Data retrieval for jobs more than 3 months old will be charged at US$30/hr. Exclusive of Government taxes.
General Terms and Conditions
-
8/20/2019 Submission Form Intertek
19/26
17
Contacts & Addresses
I NDONESIA & PAPUA NEW GUINEA
Phone Fax E-mail
John Fowler +62 816 1809012 +62 21 7807929 [email protected]
(President Director) +61 8 9251 8100 +61 8 9251 8110
INDONESIA
Minerals Lab
Stephen Southern Cilandak Commercial +62 21 7808011 +62 21 7807929 stephen.southern@inter tek.com(General Manager) Estate 103E, Jl. Cilandak KKO
Jakarta 12560, INDONESIA
Shaun Compton +62 21 7808011 +62 21 7807929 [email protected](Manager Production &
Technical Affairs Jakarta)
General Enquiries +62 21 7808011 +62 21 7807929 [email protected]
Environmental Lab
Reg de Wit Cilandak Commercial +62 21 7808011 +62 21 7803356 [email protected](Technical Advisor Estate 205, Jl. Cilandak KKO
Environmenta l) Jakarta 12560, INDONESIA
Petroleum Lab
Ismawan Cilandak Commercial +62 21 7827005 +62 21 7890389 [email protected](Petroleum Lab Manager) Estate 108, Jl. Cilandak KKO
Jakarta 12560, INDONESIA
Coal, Ores & Concentrate
Monang Pasaribu Cilandak Commercial +62 21 7808011 +62 21 7803356 [email protected](Coal, Ores & Concentrate- Estate 205, Jl. Cilandak KKO
Manager) Jakarta 12560, INDONESIA
Kalimantan Coal Labs
Jonizar Kadirisman Jl. Teuku Umar No.22 +62 541 -273111 +62 541-274333 jonizar.kadir isman@inter tek.com(Branch Manager) RT.58, Kel.Karang Asam
Samarinda 75126, INDONESIA
Tya Kusumah J l. A. Yani KM.21.500 +62 511-4705323 +62 511-4705363 tyah.kusuma@intertek .com(Branch Manager) Landasan Ulin Utara
Banjarbaru 70723, INDONESIA
Sample Preparation Facilities - IndonesiaMedan +62 61-6857512 +62 61-8460048Padang +62 751-7058114 +62 751-7058114
Sumbawa Besar +62 371-626475 +62 371-626475
Manado +62 431-815431 +62 431-815431
PAPUA NEW GUINEA
Nathan Aputi PO Box 2464 +675 472 8113 +675 472 8112 [email protected](Manager-Lae) Voco Point Rd
Morobe Province
PAPUA NEW GUINEA
Scott Sloane +62 21 7808011 +675 472 8113 +675 472 8112 [email protected]
(Technical Advisor)
-
8/20/2019 Submission Form Intertek
20/26
18
Sample Shipping
All shipments should marked
“SAMPLES FOR ANALYSIS ONLY. NO COMMERCIAL
VALUE”.
PT. Intertek Utama Services
Cilandak Commercial Estate Building 103E
Jl. Cilandak KKO
Jakarta 12560
INDONESIA
Tel. +6221 7808011 Fax. +6221 7807929
Please contact us if you need a templete for a commercial invoice for
shipping.
Samples should be delivered to:
-
8/20/2019 Submission Form Intertek
21/26
19
PT. Intertek Utama Services
SAMPLE SUBMISSION FORM
Client Order No.: Submitted by: Project:
SENDER:………………………………………...….………………………………………..…..……………………………………………………………………………………………………………...……………………….……………………………………………
Phone: ………………...….............
Fax: ……………………………..
Email: …………………...…………
Courier ………………………………….…..
Con. Note / AWB:…………………………..
Originating from …………………….……...
No. of packages ……………………………
No. of samples ……………………………..
Security Tag No.: …………………………..
Date ………………………………………....
Report to: ……………………………..….…….......
……………………………………………..………....
Copies to
1. …………………………………………………..
……………………………………………………….
2. …………………………………………………..
……………………………………………………….
Post Email
Invoice to: ……………………………………….…
……………………………………………………….
Sample Numbers SampleType
Instructions /Concentration Ranges
Elements Method of Analysis
Preparation Schemes
PT – Total Preparation: Dry, crush, pulverize entire sample to 90% passing 200#.
PB – Basic Preparation: Dry, crush, split, pulverize
-
8/20/2019 Submission Form Intertek
22/26
20
Conversion TablesSIEVE SIZES
U.S.A. Tyler Canadian British French German
Standard Alternate Mesh Standard Alternate
Nominal
Mesh No:Aperture
Nominal
No:Aperture Aperture
Nominal Nominal
125mm106mm
100mm
90mm
75mm
63mm
53mm
50mm
45mm
37.5mm
31.5mm
26.5mm
25.0mm
22.4mm
19.0mm
16.0mm
13.2mm
12.5mm
11.2mm
9.5mm
8.0mm
6.7mm
6.3mm
5.6mm
4.75mm
4.00mm
3.35mm
2.80mm
2.36mm
2.00mm 1.70mm
1.40mm
1.18mm
1.00mm
850µm
710µm
600µm
500µm
425µm
355µm
300µm
250µm
212µm
180µm
150µm
125µm
106µm
90µm
75µm
63µm
53µm
45µm
38µm
5”4.24”
4”
3.5”
3”
2.5”
2.12”
2.00”
1.75”
1.50”
1.25”
1.06”
1.00”
0.875”
0.750”
0.625”
0.530”
0.500”
0.4375”
0.375”
0.3125”
0.265”
0.250”
No: 3.5mesh
4
5
6
7
8
10 12
14
16
18
20
25
30
35
40
45
50
60
70
80
100
120
140
170
200
230
270
325
400
5”4.24”
4”
3.5”
3”
2.5”
2.12”
2.00”
1.75”
1.50”
1.25”
1.06”
1.00”
0.875”
0.750”
0.625”
0.530”
0.500”
0.4375”
0.375”
0.3125”
0.265”
0.250”
No: 3.5mesh
4
5
6
7
8
10 12
14
16
18
20
25
30
35
40
45
50
60
70
80
100
120
140
170
200
230
270
325
400
1.05”
0.883”
0.742”
0.624”
0.525”
0.441”
0.371”
No: 2.5 mesh
3
3.5
4
5
6
7
8
9 10
12
14
16
20
24
28
32
35
42
48
60
65
80
100
115
150
170
200
250
270
325
400
3.35mm
2.80mm
2.40mm
2.00mm 1.68mm
1.40mm
1.20mm
1.00mm
850µm
710µm
600µm
500µm
420µm
355µm
300µm
250µm
210µm
180µm
150µm
125µm
105µm
90µm
75µm
63µm
53µm
45µm
5
6
7
8 10
12
14
16
18
22
25
30
36
44
52
60
72
85
100
120
150
170
200
240
300
350
5.000mm
4.000mm
3.150mm
2.500mm
2.000mm1.600mm
1.250mm
1.000mm
0.800mm
0.630mm
0.500mm
0.400mm
0.315mm
0.250mm
0.200mm
0.160mm
0.125mm
0.100mm
0.080mm
0.063mm
0.050mm
0.040mm
38
37
36
35
3433
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
25.0mm
20.0mm
18.0mm
16.0mm
12.5mm
10.0mm
8.0mm
6.3mm
5.0mm
4.0mm
3.15mm
2.5mm
2.0mm 1.6mm
1.25mm
1.0mm
800µm
630µm
500µm
400µm
315µm
250µm
200µm
160µm
125µm
100µm
90µm
80µm
71µm
63µm
56µm
50µm 45µm
40µm
125mm106mm
100mm
90mm
75mm
63mm
53mm
50mm
45mm
37.5mm
31.5mm
26.5mm
25.0mm
22.4mm
19.0mm
16.0mm
13.2mm
12.5mm
11.2mm
9.5mm
8.0mm
6.7mm
6.3mm
5.6mm
4.75mm
4.00mm
3.35mm
2.80mm
2.36mm
2.00mm 1.70mm
1.40mm
1.18mm
1.00mm
850µm
710µm
600µm
500µm
425µm
355µm
300µm
250µm
212µm
180µm
150µm
125µm
106µm
90µm
75µm
63µm
53µm
45µm
38µm
-
8/20/2019 Submission Form Intertek
23/26
21
Conversion TablesCHEM ICAL CONVERSION FACTORS From Multiply by To Get From Multiply by To Get
MEASUREMENTS
From Multiply by To Get From Multiply by To Get
Lengthmetres (m) 3.281 feet (ft.) metres (m) 39.37 inches (in.)
metres (m) 1.0937 yards (yds) kilometres (km) 0.6214 miles (statute)
yards (yds.) 0.0455 chain (ch.) chain (ch.) 1 cricket pitch
Volumelitres (L) 0.2642 gallons (U.S.) litres (L) 0.22 gallons (imp)
litres (L) 33.81 U.S. ounces (ozs) litres (L) 35.2 imp ounces (ozs)
Flowlitres/minute 0.03532 cubic feet/minute litres/minute 0.2642 gallons(US)/min
(L/min) (cu.ft/min) (L/min) (gal./min)litres/min 0.22 gallons(imp)/min
Weightkilograms (kg) 35.27 long ounce (oz.) kilograms (kg) 0.0009842 long tons
kilograms (kg) 2.2046 pounds (lbs.) kilograms (kg) 0.001102 short tons
Temperaturecentigrade (Co) 1.8 (+32) Fahrenheit (Fo)
Analytical
grams/tonne (g/T) 1 ppm mg/L 1 ppmug/L 1 ppb
Al 1.889 Al2O
3Mo 1.500 MoO
As 1.320 As2O3 Na 1.348 Na2OB 3.220 B
2O
3 Nb 1.431 Nb
2O
5
Ba 1.117 BaO Ni 1.273 NiO
Be 2.775 BeO P 2.291 P2O
5
Ca 1.399 CaO Pb 1.077 PbO
Ce 1.171 Ce2O
3Rb 1.094 Rb
2O
Co 1.271 CoO Sb 1.197 Sb2O
3
Cr 1.462 Cr 2O
3Si 2.139 SiO
2
Cs 1.060 Cs2O Sn 1.270 SnO
2
Cu 1.252 CuO Sr 1.183 SrO
F 2.055 CaF2
Ta 1.221 Ta2O
5
Fe 1.287 FeO Th 1.138 ThO2
Fe 1.430 Fe2O
3Ti 1.668 TiO
2K 1.205 K
2O U 1.179 U
3O
8
La 1.173 La2O
3V 1.785 V
2O
5
Li 2.153 Li2O W 1.261 WO
3
Mg 1.658 MgO Y 1.270 Y2O
3
Mn 1.291 MnO Zn 1.245 ZnO
Mn 1.582 MnO2
Zr 1.351 ZrO2
-
8/20/2019 Submission Form Intertek
24/26
22
Conversion Tables
COMMON DRILL CORE SIZES
Nominal Nominal core volume/metre (m3x10-3)
core diameter
Size (mm) Full Core Half Core Quarter Core
GOLD ASSOCIATED M INERALS
GOLD M INERALS
May contain gold up to the following concentrations
Allemontite 500ppm Jarosite 7 900ppm
Altaite 400ppm Limonite (geothite) 35ppm
Antimony (native) 35ppm Melonite 3 200ppm
Acanthite 200ppm Osmiridium 20%Arsenic (native) 150ppm Platiiridium 200ppm
Arsenopyrite 500ppm Platinum (native) 30 000ppm
Aurian silver 30% Pyrite 560ppm
Berzelianite 100ppm Pyrrhotite 22ppm
Bismuthinite 3 300ppm Safflorite 700ppm
Chalcopyrite 20ppm Sphalerite 500ppm
Clausthalite 250ppm Stibnite 20ppm
Copper (native) 200ppm Tellurium (native) 30 000ppm
Gerdorffite 100ppm Tetrahedrite 100ppm
Hessite 2 000ppm Ulmanite 20ppm
Iridosmine 10 000ppm Uraninite 30ppm
TT 35.0 0.96 0.48 0.24
BQ 36.4 1.04 0.52 0.26
NQ 47.6 1.78 0.89 0.45
HQ 63.5 3.17 1.59 0.79
BQ3 33.5 0.88 0.44 0.22
NQ3 45.1 1.60 0.80 0.40HQ3 61.1 2.93 1.47 0.73
Core weight (kg) = Core volume x Core density
Native & AlloysGold (native) Au(Ag,Hg) Auricupride Cu
3Au Bismuthian gold (Au,Bi)
Cuprian gold (Au,Cu) Electrum (Au,Ag) Iridian gold (Au,Ir)Palladian gold (Au,Pd) Platinian gold (Au,Pt) Rhodian gold (Au,Rh)
Rozhkovite (Cu,Pd)3Au
2Tetraauricupride CuAu
Intermetallic compoundsAmalgam Au
2Hg
3 (gamma) Aurostibite AuSb
2Maldonite Au
2Bi
Weiskanite Au1.2
Hg0.8
Gold Sulphides, Selenides & TelluridesBessmertnovite Au
4Cu.nTeO
2Bilibinskite Au
3Cu
2Pb.nTeO
2Bogdanovite Au
5(Cu,Fe)
3(Te,Pb)
2
Calaverite AuTe2
Fischesserite Ag3
AuSe2
Kostovite CuAuTe4Krennerite (Au,Ag)Te
2Liujinyinite Ag
3AuS
2Montbrayite (Au,Sb)
2Te
3
Nagyagite Pb5Au(Te,Sb)
4S
5-8Penginite Ag
4Au(S,Se)
4Petrovskaite AuAg(S,Se)
Petzite Ag3AuTe
2Sylvanite AgAuTe
4Uytenbolgaardtite Ag
3AuS
2
-
8/20/2019 Submission Form Intertek
25/26
-
8/20/2019 Submission Form Intertek
26/26
Papua New Guinea
Nathan Aputi
Lae Laboratory and Site Sample Preparation Facilities
Tel: +675 4728 113Mob: +675 6877 [email protected]
Philippines
Manila Laboratory and Site Sample Preparation Facilities
Allen Hingst
Tel: +632 8423 464Mob: +62 8111 49865
Australia
Head Office & Main Laboratory and Sample Preparation Facilities
Gary Wheeler
Tel: +61 8 9251 8100Mob: +61 4199 68474
China
Beijing Minerals Laboratory
Scott Sloane
Tel: +86 10 8947 5200mob: +86 139019 68897
Adam Huang
mob: +86 139018 68028
Kunming Sample Preparation Facilities
Tel : +86 87 13813 809
Intertek
Scott Sloane
Tel: +675 4728 113
Mob: +675 6203029