submittal approval form - redteam software · tce job #100707 . owner: orange county public schools...

18
Submittal Approval Form PROJECT: CLAY SPRINGS ELEMENTARY SCHOOL DATE: ____________________ ______ SUBCONTRACTOR NAME: __ SUBCONTRATOR ADDRESS: ______________________________ ____ NUMBER AND TITLE OF SPECIFICATION SECTION: Contractor’s Submittal Stamp Architect/ Engineer’s Submittal Stamp Product Data & QD F REVIEWED F REJECTED F REVISE AND F FURNISHED AS RESUBMIT CORRECTED Corrections or comments made on the shop drawings during this review do not relieve Subcontractor/Supplier from compliance with requirements of the drawings and specifications. This check is only for review of the general conformance with the design of the project and general compliance with the information given in the contract documents. The Subcontractor/Supplier is responsible for: Confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction. WILLIAMS COMPANY BUILDING DIVISION Date: Trent Bonnett Project Manager

Upload: others

Post on 30-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

Submittal Approval Form

PROJECT: CLAY SPRINGS ELEMENTARY SCHOOL

DATE: ____________________ ______

SUBCONTRACTOR NAME: __

SUBCONTRATOR ADDRESS: ______________________________ ____

NUMBER AND TITLE OF SPECIFICATION SECTION:

Contractor’s Submittal Stamp Architect/ Engineer’s Submittal Stamp

Product Data & QD

REVIEWED REJECTED

REVISE AND FURNISHED AS RESUBMIT CORRECTED

Corrections or comments made on the shop drawings during this review do not relieve Subcontractor/Supplier from compliance with requirements of the drawings and specifications. This check is only for review of the general conformance with the design of the project and general compliance with the information given in the contract documents. The Subcontractor/Supplier is responsible for: Confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction.

WILLIAMS COMPANY BUILDING DIVISION

Date:Trent Bonnett

Project Manager

jordan
Typewritten Text
jordan
Typewritten Text
2/17/15
jordan
Typewritten Text
2/17/15
Page 2: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

Submittal Cover.doc

ABC ACCREDITED QUALITY CONTRACTOR EC-0000981

430 West Drive Altamonte Springs, Florida 32714 EC-0000981 Phone: (407) 788-3500

CLAY SPRINGS ELEMENTARY SCHOOL

TCE JOB #100707

OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809

GENERAL CONTRACTOR: Williams Company 2301 Silver Star Road Orlando, FL 32804

ARCHITECT: Rhodes + Brito Architects 605 E. Robinson Street, Suite 750 Orlando, FL 32801

ENGINEER: Matern Professional Engineering, Inc. 130 Candace Drive Maitland, FL 32751

SUBCONTRACTOR: Tri-City Electrical Contractors, Inc. 430 West Drive Altamonte Springs, FL 32714

Specification Section: 28 23 00 CCTV System Qualification Data Resubmittal

Page 3: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 4: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 5: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 6: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 7: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 8: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 9: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:
Page 10: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

Submittal Cover.doc ABC ACCREDITED QUALITY CONTRACTOR EC-0000981

430 West Drive Altamonte Springs, Florida 32714 EC-0000981 Phone: (407) 788-3500

CLAY SPRINGS ELEMENTARY SCHOOL

TCE JOB #100707 OWNER: Orange County Public Schools

Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR: Williams Company

2301 Silver Star Road Orlando, FL 32804

ARCHITECT: Rhodes + Brito Architects

605 E. Robinson Street, Suite 750 Orlando, FL 32801

ENGINEER: Matern Professional Engineering, Inc.

130 Candace Drive Maitland, FL 32751

SUBCONTRACTOR: Tri-City Electrical Contractors, Inc. 430 West Drive

Altamonte Springs, FL 32714 Specification Section: 28 23 00 CCTV System

Product Data Resubmittal

Page 11: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

For more Information please call

1-800-Belden1

Description:20 AWG bare copper conductor, gas-injected foam high density polyethylene, bare copper braid shield,PVC jacket.

Usage (Overall)Suitable Applications: CCTV plus Audio, Pan and Tilt CCTV Control

CoaxPhysical Characteristics

ConductorAWG:

# Coax AWG Stranding Conductor Material Dia. (mm)1 20 Solid BC - bare Copper 0.813

InsulationInsulation Material:

Insulation Material Dia. (mm)Gas-injected FHDPE - Foam High Density Polyethylene 3.683

Inner ShieldInner Shield Material:

Type Inner Shield Material % Coverage (%)Braid BC - Bare Copper 95.000

Applicable Specifications and Agency ComplianceApplicable Standards & Environmental Programs

EU CE Mark: Yes

RG Type: 59/U

Electrical CharacteristicsNom. Characteristic Impedance:

Impedance (Ohm)75

Nom. Inductance:Inductance (µH/m)0.318

Nom. Capacitance Conductor to Shield:Capacitance (pF/m)53.480

Nominal Velocity of Propagation:VP (%)83.000

Nominal Delay:Delay (ns/m)4.003

Nom. Conductor DC Resistance:DCR @ 20°C (Ohm/km)

Page 1 of 4 09-04-2012

Detailed Specifications & Technical DataMETRIC MEASUREMENT VERSION

549945 Composite - CCTV Plus Audio or Power or Pan and Tilt CCTV Control Applications

Page 12: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

32.810

Nom. Inner Shield DC Resistance:DCR @ 20°C (Ohm/km)11.484

Nom. Attenuation:Freq. (MHz) Attenuation (dB/100m)1.000 0.9845.000 2.13310.000 2.95350.000 6.234100.000 8.531200.000 11.812400.000 16.405700.000 22.967900.000 26.2481000.000 27.889

Max. Operating Voltage - UL: 350 V RMS

Twisted PairPhysical Characteristics

ConductorAWG:

# Pairs AWG Stranding Conductor Material Dia. (mm)1 18 7x26 BC - Bare Copper 1.168

InsulationInsulation Material:

Insulation Material Dia. (mm)PP - Polypropylene 1.499

Twisted Pair Color Code Chart:Number Color1 Black and Red

Electrical CharacteristicsNom. Capacitance Conductor to Conductor:

Capacitance (pF/m)73.823

Physical Characteristics (Overall)ConductorOuter Shield

Outer Shield Material:Outer Shield MaterialUnshielded

Outer JacketOuter Jacket Material:

Outer Jacket MaterialPVC - Polyvinyl Chloride

Overall CableOverall Nominal Diameter: 5.893 x 11.430 mm

Mechanical Characteristics (Overall)Operating Temperature Range: -30°C To +80°C

UL Temperature Rating: 75°C

Bulk Cable Weight: 80.363 Kg/Km

Page 2 of 4 09-04-2012

Detailed Specifications & Technical DataMETRIC MEASUREMENT VERSION

549945 Composite - CCTV Plus Audio or Power or Pan and Tilt CCTV Control Applications

Page 13: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

Max. Recommended Pulling Tension: 453.716 N

Min. Bend Radius/Minor Axis: 63.500 mm

Applicable Specifications and Agency Compliance (Overall)Applicable Standards & Environmental Programs

NEC/(UL) Specification: CMG

NEC Articles: 800

CEC/C(UL) Specification: CMG

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2002/95/EC (RoHS): Yes

EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2005

EU Directive 2002/96/EC (WEEE): Yes

EU Directive 2003/11/EC (BFR): Yes

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Flame TestUL Flame Test: UL1685 UL Loading

C(UL) Flame Test: FT4

SuitabilitySuitability - Indoor: Yes

Suitability - Outdoor: Yes

Suitability - Aerial: Yes

Plenum/Non-PlenumPlenum (Y/N): No

Plenum Number: 649948

Put Ups and Colors:

Item # Putup Ship Weight Color Notes Item Desc549945 0091000 305 MT 24.041 KG WHITE C 1 #18 PR, 1 RG-59/U COAX 549945 009500 152 MT 12.927 KG WHITE C 1#18,1RG-59/U COAX 549945 0101000 305 MT 24.041 KG BLACK C 1#18,1RG-59/U COAX 549945 010500 152 MT 12.927 KG BLACK C 1#18,1RG-59/U COAX

Notes:C = CRATE REEL PUT-UP.

Revision Number: 5 Revision Date: 06-28-2012

© 2012 Belden, IncAll Rights Reserved.

Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specificationsdescribed herein are subject to error or omission and to change without notice, and the listing of such information and specifications does notensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, orexemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to thecompliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, andthe identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guidefor the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is notto be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible fordetermining the applicability of legislation and regulations based on their individual usage of the product.

Page 3 of 4 09-04-2012

Detailed Specifications & Technical DataMETRIC MEASUREMENT VERSION

549945 Composite - CCTV Plus Audio or Power or Pan and Tilt CCTV Control Applications

Page 14: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.

Page 4 of 4 09-04-2012

Detailed Specifications & Technical DataMETRIC MEASUREMENT VERSION

549945 Composite - CCTV Plus Audio or Power or Pan and Tilt CCTV Control Applications

Page 15: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

6 LAN Plus4 Pair #23 AWG UTP Category 6

TABLE 1

PAIR PAIR

NUMBER COLOR CODE

1 WHITE-BLUE BLUE

2 WHITE-ORANGE ORANGE

3 WHITE-GREEN GREEN

4 WHITE-BROWN BROWN

TABLE 2

PLENUM NON-PLENUM

PART JACKET PART JACKET

NUMBER COLOR NUMBER COLOR

M58801 BLUE M58804 BLUE

M58802 WHITE M58805 WHITE

M58863 YELLOW M58920 YELLOW

M58803 GRAY M58806 GRAY

M58914 PINK M58919 PINK

M58915 GREEN M58922 GREEN

M58916 RED M58923 RED

M58917 ORANGE M58924 ORANGE

M58918 BLACK M58925 BLACK

M58794 VIOLET M58795 VIOLET

DESCRIPTION

ENHANCED UNSHIELDED TWISTED PAIR (UTP) 6 LAN PLUS CABLEFOR USE IN HORIZONTAL CABLING SYSTEMS PER TIA 568-B. THECABLE EXCEEDS TIA 568-B.2-1 & ISO/IEC 11801 CATEGORY 6. THECABLE CONSISTS OF #23 AWG SOLID BARE COPPER INSULATED CON-DUCTORS, ASSEMBLED INTO FOUR TIGHTLY TWISTED PAIRS, WITH ACORE SEPARATOR AND A RIPCORD, UNDER AN OVERALL JACKET.PRINT INCLUDES DESCENDING FOOTAGE MARKERS FROM 1000 TO 0ON EACH 1000 FT REEL OR BOX. THIS PRODUCT AND/OR ITS MANU-FACTURE IS COVERED BY US PATENT NOS. 6998537, 6570095 & 5424491.

THE PLENUM RATED CABLE IS FOR USE IN AIR HANDLING DUCTSAND SPACES IN ACCORDANCE WITH ARTICLE 800 OF THE NATIONALELECTRICAL CODE (NEC). THE CABLE IS ETL (USA) & cETL (CANADA)LISTED FOR THIS APPLICATION BY PASSING NFPA 262 (FT6 OR PREVI-OUSLY UL 910 STEINER TUNNEL) TEST.

THE RISER (NON-PLENUM) RATED CABLE IS FOR USE AS A VERTICALRUN IN A SHAFT AND FOR GENERAL PURPOSE COMMUNICATIONS USEIN ACCORDANCE WITH ARTICLE 800 OF THE NATIONAL ELECTRICALCODE (NEC). THE CABLE IS UL (USA) & cUL (CANADA) LISTED FOR THISAPPLICATION BY PASSING THE UL 1666 RISER CABLE FLAMMABILITYTEST. THE CABLE ALSO PASSES THE CSA FT4 VERTICAL FLAME TEST -CABLES IN CABLE TROUGH FROM CLAUSE 4.11.4 OF CSA C22.2 NO. 0.3.

SUPPORTED APPLICATIONS

IEEE 802.3an 10GBASE-T (10 GIGABIT ETHERNET), 1000BASE-T (GIGA-BIT ETHERNET), 100BASE-T (FAST ETHERNET), AND IEEE 802.3 10BASE-T(ETHERNET), IEEE 802.3af POWER OVER ETHERNET FOR VoIP,ANSI.X3.263 FDDI TP-PMD, IEEE 802.5 4 AND 16 Mbps TOKEN RING, ATMUP TO 1.2 Gbps, 550 MHz BROADBAND VIDEO AND STANDARDS UNDERDEVELOPMENT SUCH AS ATM AT 2.4 AND 4.8 Gbps.

CONSTRUCTION

PRIMARIES: CONDUCTOR: 23 AWG (.6 mm PL, .5mm NP) SOLID BARE COPPER

INSULATION: PL: DUAL INSULATION, FEP ON ALL 4 PAIRS

NP: THERMOPLASTIC POLYOLEFIN

PAIR ASSEMBLY: 2 PRIMARIES TWISTED IN VARIED LAYS

COLOR CODE: SEE TABLE 1

CABLE ASSEMBLY: 4 PAIRS CABLED TOGETHER WITH A CORE SEPARATOR

JACKET: PL: NO LEAD PLENUM RATED THERMOPLASTICNP: NO LEAD FLAME RETARDANT THERMOPLASTIC

JACKET COLOR SEE TABLE 2

NOMINAL CABLE OD: PL: .207” (5.26 mm)

NP: .216” (5.5 mm)

LISTINGS: ETL VERIFIED TO TIA 568-B.2-1 CAT 6

PL: C(ETL)US TYPE CMP

NP: C(UL)US TYPE CMR

PL = PLENUMNP = NON-PLENUM

PHYSICAL CHARACTERISTICS

CABLE WEIGHT: PL: 28 lbs/1000ft (42 kg/km)

NP: 26 lbs/1000ft (39 kg/km)

BENDING RADIUS: 1” (25mm) MIN (4 X CABLE OD)

PULLING TENSION: 25 lbf (110 N) MAX

OPERATING TEMP.: -20ºC to +60ºC (-4ºF to +140ºF)

STORAGE TEMP.: -20°C to +75°C (-4°F to +167°F)

INSTALLATION 0°C to +60°C (+32°F to +140°F)

TEMP.*:

*THE INSTALLATION TEMPERATURE REFERS TO THE TEMPERATURE OFTHE CABLE WHILE BEING INSTALLED OR PULLED. DO NOT INSTALL CABLEBELOW 0°C (+32°F).

Page 16: Submittal Approval Form - RedTeam Software · TCE JOB #100707 . OWNER: Orange County Public Schools Design & Construction Bldg. 200, 6501 Magic Way Orlando, FL 32809 GENERAL CONTRACTOR:

ELECTRICAL CHARACTERISTICS (REF TABLE 3)

CONDUCTOR DCR: PL: 7.8 Ω/100m (23.8 Ω/Mft) MAXNP: 8.9 Ω/100m (27.1 Ω/Mft) MAX

DCR UNBALANCE: 3% MAX

MUTUALCAPACITANCE: 46 pF/m (14 pF/ft) NOM

CAPACITANCE UNBALANCEPAIR/GROUND: 66 pF/100m (200 pF/Mft) MAX

CHARACTERISTICIMPEDANCE: 100 Ω ± 15% (1-250 MHz)

INPUT 100 Ω ± 15% (1-100 MHz)IMPEDANCE: 100 Ω ± 20% (>100-200 MHz)

100 Ω ± 25% (>200 MHz)

RETURN LOSS (RL): 20 + 5 log10 (f ) dB MIN (1-10 MHz)25 dB MIN (>10-20 MHz)25 - 7 log10 (f /20) dB MIN (>20 MHz)

INSERTION LOSS: 1.808 √f + .017f + .20/√f dB/100m MAX

NEAR ENDCROSSTALK (NEXT): 47.3 - 15 log10 (f /100) dB/100m MIN

POWER SUM NEAR ENDCROSSTALK (PS NEXT): 45.3 - 15 log10 (f /100) dB/100m MIN

EQUAL LEVEL FAR END CROSSTALK(ELFEXT): 27.8 - 20 log10 (f /100) dB/100m MIN

POWER SUM EQUAL LEVEL FAR END CROSSTALK(PS-ELFEXT): 24.8 - 20 log10 (f /100) dB/100 MIN

PROPAGATION DELAY: 534 + 36 / √f ns/100m MAX

DELTA DELAY (SKEW): 45 ns/100m MAX

NOMINAL VELOCITY OF 72% PLPROPAGATION (NVP): 68% NP

WHERE f = FREQUENCY IN MHz from .772 to 250 MHz.

TABLE 3

REFERENCE ELECTRICAL CHARACTERISTICS

6 LAN Plus4 Pair #23 AWG UTP Category 6

Mohawk reserves the right to change any specification in the interest of product enhancement.

9 Mohawk Drive, Leominster, MA 01453(978) 537-9961 • 1-800-422-9961 • FAX (978) [email protected] www.mohawk-cable.com©Mohawk 12/2009

FREQ INSERTION LOSS NEXT ACR PS-NEXT PS-ACR ELFEXT PS-ELFEXT RL(MHz) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

avg max avg min min avg min min min min min.772 1.7 1.8 85 79.0 77.2 80 77.0 75.2 - - -1.0 1.9 2.0 83 77.3 75.3 78 75.3 73.3 67.8 64.8 20.04.0 3.6 3.8 74 68.3 64.5 69 66.3 62.5 55.8 52.8 23.08.0 5.1 5.3 70 63.8 58.5 65 61.8 56.5 49.7 46.7 24.510.0 5.7 6.0 68 62.3 56.3 63 60.3 54.3 47.8 44.8 25.016.0 7.3 7.6 65 59.2 51.6 60 57.2 49.6 43.7 40.7 25.020.0 8.1 8.5 64 57.8 49.3 59 55.8 47.3 41.8 38.8 25.025.0 9.1 9.5 62 56.3 46.8 57 54.3 44.8 39.8 36.8 24.331.25 10.2 10.7 61 54.9 44.2 56 52.9 42.2 37.9 34.9 23.662.5 14.8 15.4 56 50.4 35.0 51 48.4 33.0 31.9 28.9 21.5100.0 19.0 19.8 53 47.3 27.5 48 45.3 25.5 27.8 24.8 20.1155.0 24.2 25.2 50 44.4 19.2 45 42.4 17.2 24.0 21.0 18.8200.0 27.8 29.0 49 42.8 13.8 44 40.8 11.8 21.8 18.8 18.0250.0 31.5 32.8 47 41.3 8.5 42 39.3 6.5 19.8 16.8 17.3300.0 35.0 36.4 46 40.1 3.7 41 38.1 - 18.3 15.3 16.8350.0 38.2 39.8 45 39.1 - 40 37.1 - 16.9 13.9 16.3400.0 41.3 43.0 44 38.3 - 39 36.3 - 15.8 12.8 15.9500.0 47.0 48.9 43 36.8 - 38 34.8 - 13.8 10.8 15.2550.0 49.7 51.8 42 36.2 - 37 34.2 - - - 14.9

VALUES ABOVE 250 MHz ARE FOR ENGINEERING INFORMATION ONLY