submittal cover sheet...[381 mm] 291/2 [749 mm] 13 [330 mm] st-a1273-01-f 901/8 [2289 mm] 281/2 [724...

3
SUBMITTAL COVER SHEET Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number ACCESSORIES: NOTES: PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640 PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY

Upload: others

Post on 19-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • SUBMITTAL COVER SHEET

    Quantity

    Unit Designation

    Model No.

    Total Cooling

    Sensible Cooling

    Air Ent. Evaporator

    Air Lvg. Evaporator

    Heating Input

    Heating Output

    CFM/ESP

    EER/SEER

    Electrical

    Minimum Ampacity

    Min.-Max. Breaker

    Net Unit Weight

    Accessory

    Catalog Form Number

    ACCESSORIES: NOTES:

    PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640

    PROJECT NAME

    LOCATION

    ARCHITECT

    ENGINEER

    CONTRACTOR

    SUBMITTED BY DATE

    UNIT SUMMARY

  • SUBMITTAL SHEET FOR PACKAGE HEAT PUMPSRHPD SERIESNOMINAL SIZES 7.5-12.5 TONS [26-44 kW]

    JOB NAME

    CONTRACTOR

    ENGINEER

    LOCATION

    ORDER NO.

    FORM NO. X33-1584

    SUBMITTED FOR APPROVAL RECORD

    SUBMITTED BY

    DATE

    UNIT DESIGNATION

    MODEL NO.

    e a r t h f r i e n d l y r e f r i g e r a n t

    UNIT DATACOOLING PERFORMANCE

    TOTAL CAPACITY* .......................... _______ MBHSENSIBLE CAPACITY* .................... _______ MBHOUTDOOR DESIGN TEMP. .._______ °F [°C] DB/WBTOTAL SUPPLY AIR .................. _______ CFM [L/s]TEMP. OF AIR ENTERING

    EVAPORATOR COIL ........ _______ °F [°C] DB/WBPOWER INPUT REQUIREMENT .......... _______ kWSEER/EER RATING .................................. _______(*uses blower motor heat)

    HEATING PERFORMANCEHEAT PUMP HEATING PERFORMANCECAPACITY @ 47°F.............................. ________MBHCAPACITY @ 17°F.............................. ________MBHCOEFFICIENT OF PERFORMANCE@ 47°F .............................................. ________C.O.P.@ 17°F .............................................. ________C.O.P.H.S.P.F. ........................................................ _______AUX. ELECTRIC HEAT CAPACITY ........ _______ kW

    SUPPLY AIR BLOWER PERFORMANCETOTAL SUPPLY AIR .................. _______ CFM [L/s]TOTAL RESISTANCE EXTERNAL

    TO UNIT........................................ _______ IWGBLOWER SPEED ............................ _______ RPMPOWER OUTPUT REQUIREMENT .... _______ BHPMOTOR RATING .......................... _______ HP [W]POWER INPUT REQUIREMENT .......... _______ kW

    ELECTRICAL DATAPOWER SUPPLY ........................ ____________ Hz

    TOTAL UNIT AMPACITY.................. _______ AMPSMINIMUM WIRE SIZE ...................... _______ AWGMAXIMUM OVERCURRENT DEVICE

    FUSES HACR BREAKER .......... _______ AMPS

    TOTAL UNIT WEIGHTTOTAL OPERATING WEIGHT ...... _______ LBS [kg](including field-installed accessories)

    CLEARANCESFRONT 48" [1219 mm]

    CONDENSER COIL 18" [457 mm]

    DUCT SIDE 12" [305 mm]

    EVAPORATOR END 36" [914 mm]

    ABOVE UNIT 60" [1524 mm]

    [ ] Designates Metric Conversions

    • Factory charged with R-410A HFC refrigerant• Wired and run tested• Scroll compressors with internal line break overload and high pressure

    protection• Model RHPDZR has a single-stage compressor• Models RHPDZS and RHPDZT have two-stage compressor • Convertible airflow – vertical down flow or horizontal side flow• Forkable base rails for easy handling and lifting• Cooling operation up to 125°F ambient• MicroChannel evaporator and condenser coil • PlusOne® ServiceSmart package includes:

    Qwik-Change Flex-Fit RackQwik-Slide Blower AssemblyQwik-Clean Drain Pan

    • Overflow condensate sensor• PlusOne® Diagnostics with Dual 7-Segment LED Display to meet code

    compliance• One-piece top cover and base pan with drawn supply and return

    opening • Two-piece control door • ¼ turn fasteners on filter access door • Color-coded and labeled wiring• External lockable gauge ports• TXV refrigerant metering system • Solid-core liquid line filter drier • High pressure and low pressure/loss of charge protection with built in

    Smart Logic• Insulation encapsulated throughout entire unit • High performance belt drive motor with variable pitch pulleys and quick

    adjust belt system• Variable Frequency Drive (VFD) blower is standard on Model RHPDZT

    and optional on model RHPDZS • New product footprint with matching connections• Improved factory lead times

    FEATURES FOR RHPD SERIES PACKAGE HEAT PUMP UNITS

  • IllustrationST-A1273-01_D-00

    FILTERACCESS PANEL

    INDOOR COILACCESS PANEL

    33/4�[97 mm]

    901/8�[2289 mm]

    591/2�[1511 mm]

    41/4�[110 mm]

    291/4�[743 mm]

    323/4�[832 mm]

    POWERENTRY

    RECEPTACLE

    SERVICEPORT DOOR

    SUPPLY AIR

    RETURNAIR

    61/8�[156 mm]

    31/2�[89 mm]

    371/2�[953 mm]

    51/8�[130 mm]

    197/8�[505 mm]217/8�

    [555 mm]593/8�

    [1510 mm]

    57/8�[149 mm]

    51/4�[133 mm]

    15�[381 mm]

    291/2�[749 mm]

    13�[330 mm]

    IllustrationST-A1273-01-F

    901/8�[2289 mm]

    281/2�[724 mm]

    63/4�[171 mm]

    51/2�[140 mm]

    125/8�[321 mm]

    593/8�[1507 mm]

    363/8�[224 mm]

    263/4�[679 mm]

    11/4�[32 mm]

    14�[356 mm]

    61/2�[165 mm]

    41/8�[105 mm]

    SUPPLY

    RETURN

    IllustrationST-A1273-01_A-00

    863/4�[2203 mm]

    591/2�[1511 mm]

    553/8�407 mm]

    143/8�[365 mm]

    371/2�[953 mm]

    2�[51 mm]

    TYP. (3) SIDES

    IllustrationST-A1273-26-00

    RETURN COVER

    DRAIN PAN

    SUPPLY COVER

    ACCESS PANELBLOWER

    ACCESS PANELHEAT EXCHANGER

    150 MODEL60�

    [1524 mm]

    090 THRU 120MODELS

    50�[1270 mm]

    89�[2261 mm]

    577/8�[1470 mm]

    CONTROL ACCESS

    SERVICE DISCONNECTKNOCKOUT

    ACCESS PANEL COMPRESSOR

    SUPPLY ANDRETURNDIMENSIONSFORDOWNFLOWAPPLICATIONS

    SUPPLY AND RETURNDIMENSIONS FORHORIZONTAL APPLICATIONS

    [ ] Designates Metric Conversions

    Accessory

    Economizer w/Single Enthalpy (Downflow)

    Economizer w/Single Enthalpy (Horizontal)

    Economizer-w/Single Enthalpy (Downflow) DDC

    Economizer w/Single Enthalpy (Horizontal) DDC

    Dual Enthalpy Kit

    Dual Enthalpy Kit DDC

    Carbon Dioxide Sensor (Wall Mount)

    Power Exhaust

    Power Exhaust

    Manual Fresh Air Damper

    Motorized Fresh Air Damper

    Motorized Fresh Air Damper (DDC)

    Roofcurb, 14"

    Roofcurb, 24"

    Roofcurb Adapter

    Concentric Diffuser 7.5/8.5 Ton Flush

    Concentric Diffuser 10.0 Ton Flush

    Concentric Diffuser 12.5 Ton Flush

    Concentric Diffuser 7.5/8.5 Ton Drop

    Concentric Diffuser 10.0 Ton Drop

    Concentric Diffuser 12.5 Ton Drop

    Accessory

    Concentric Adapter 7.5/8.5 Ton Drop

    Concentric Adapter 10 Ton Drop

    Concentric Adapter 12.5 Ton Drop

    Outdoor Coil Louver Kit - ACD/090/102/120

    Outdoor Coil Louver Kit - ACD150

    Unwired Convenience Outlet

    Unfused Service Disconnect

    Comfort Alert (1 Per Compressor)

    Comfort Alert (1 Per Compressor)

    BACnet Communication Card

    LonWorks Communication Card

    Room Humidity Sensor

    Room Temperature and Relative Humidity Sensor

    Low-Ambient Control Kit

    Freeze Stat Kit

    Variable Frequency Drive Kit**See model number break down below

    Electric Heater KitsSingle Point Wiring Kit*

    Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices. Rheem Sales Company, Inc.P.O. Box 17010, Fort Smith, AR 72917

    “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”

    PRINTED IN U.S.A. 1-19 QG FORM NO. X33-1584

    Project Name: Location: Architect: Engineer: Contractor: Submitted By: Date: Quantity 1: Quantity 2: Quantity 3: Quantity 4: Quantity 5: Quantity 6: Unit Designation1: Unit Designation2: Unit Designation3: Unit Designation4: Unit Designation5: Unit Designation6: Model No: 1: 2: 3: 4: 5: 6: :

    Total Cooling1: Total Cooling2: Total Cooling3: Total Cooling4: Total Cooling5: Total Cooling6: Sensible Cooling1: Sensible Cooling2: Sensible Cooling3: Sensible Cooling4: Sensible Cooling5: Sensible Cooling6: Air Ent: Evaporator1: Evaporator2: Evaporator3: Evaporator4: Evaporator5: Evaporator6:

    Air Lvg: Evaporator1: Evaporator2: Evaporator3: Evaporator4: Evaporator5: Evaporator6:

    Heating Input1: Heating Input2: Heating Input3: Heating Input4: Heating Input5: Heating Input6: Heating Output1: Heating Output2: Heating Output3: Heating Output4: Heating Output5: Heating Output6: CFM/ESP1: CFM/ESP2: CFM/ESP3: CFM/ESP4: CFM/ESP5: CFM/ESP6: EER/SEER1: EER/SEER2: EER/SEER3: EER/SEER4: EER/SEER5: EER/SEER6: Electrical1: Electrical2: Electrical3: Electrical4: Electrical5: Electrical6: Minimum Ampacity1: Minimum Ampacity2: Minimum Ampacity3: Minimum Ampacity4: Minimum Ampacity5: Minimum Ampacity6: Min: -Max: Breaker1: Breaker2: Breaker3: Breaker4: Breaker5: Breaker6:

    Net Unit Weight1: Net Unit Weight2: Net Unit Weight3: Net Unit Weight4: Net Unit Weight5: Net Unit Weight6: Accessory1: Accessory2: Accessory3: Accessory4: Accessory5: Accessory6: Catalog Form Number1: Catalog Form Number2: Catalog Form Number3: Catalog Form Number4: Catalog Form Number5: Catalog Form Number6: Accessories: Notes: Job Name: Contractor : Engineer : Location : Order No: Approval: OffRecord: OffSubmitted By : Date : Unit Designation: Total Capacity1: Sensible Capacity: Outdoor Design Temperature: Total Supply Air: Temperature of Air Entering: Power Input Requirement: SEER/EER Rating: Heat Pump Capacity 47ºF: Heat Pump Capacity 17ºF: Coefficient of Performance 47ºF: Coefficient of Performance 17ºF: H: S: P: F:

    Electric Heat Capacity: Supply Air: External Static Pressure: Blower Speed: Power Output: Motor Rating: Power Input Requirement3: Power Supply: Total Unit Ampacity: Minimum Wire Size: Max Overcurrent Device HACR Circuit Breaker: Total Weight: