submittal cover sheet...[381 mm] 291/2 [749 mm] 13 [330 mm] st-a1273-01-f 901/8 [2289 mm] 281/2 [724...
TRANSCRIPT
-
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
-
SUBMITTAL SHEET FOR PACKAGE HEAT PUMPSRHPD SERIESNOMINAL SIZES 7.5-12.5 TONS [26-44 kW]
JOB NAME
CONTRACTOR
ENGINEER
LOCATION
ORDER NO.
FORM NO. X33-1584
SUBMITTED FOR APPROVAL RECORD
SUBMITTED BY
DATE
UNIT DESIGNATION
MODEL NO.
e a r t h f r i e n d l y r e f r i g e r a n t
UNIT DATACOOLING PERFORMANCE
TOTAL CAPACITY* .......................... _______ MBHSENSIBLE CAPACITY* .................... _______ MBHOUTDOOR DESIGN TEMP. .._______ °F [°C] DB/WBTOTAL SUPPLY AIR .................. _______ CFM [L/s]TEMP. OF AIR ENTERING
EVAPORATOR COIL ........ _______ °F [°C] DB/WBPOWER INPUT REQUIREMENT .......... _______ kWSEER/EER RATING .................................. _______(*uses blower motor heat)
HEATING PERFORMANCEHEAT PUMP HEATING PERFORMANCECAPACITY @ 47°F.............................. ________MBHCAPACITY @ 17°F.............................. ________MBHCOEFFICIENT OF PERFORMANCE@ 47°F .............................................. ________C.O.P.@ 17°F .............................................. ________C.O.P.H.S.P.F. ........................................................ _______AUX. ELECTRIC HEAT CAPACITY ........ _______ kW
SUPPLY AIR BLOWER PERFORMANCETOTAL SUPPLY AIR .................. _______ CFM [L/s]TOTAL RESISTANCE EXTERNAL
TO UNIT........................................ _______ IWGBLOWER SPEED ............................ _______ RPMPOWER OUTPUT REQUIREMENT .... _______ BHPMOTOR RATING .......................... _______ HP [W]POWER INPUT REQUIREMENT .......... _______ kW
ELECTRICAL DATAPOWER SUPPLY ........................ ____________ Hz
TOTAL UNIT AMPACITY.................. _______ AMPSMINIMUM WIRE SIZE ...................... _______ AWGMAXIMUM OVERCURRENT DEVICE
FUSES HACR BREAKER .......... _______ AMPS
TOTAL UNIT WEIGHTTOTAL OPERATING WEIGHT ...... _______ LBS [kg](including field-installed accessories)
CLEARANCESFRONT 48" [1219 mm]
CONDENSER COIL 18" [457 mm]
DUCT SIDE 12" [305 mm]
EVAPORATOR END 36" [914 mm]
ABOVE UNIT 60" [1524 mm]
[ ] Designates Metric Conversions
• Factory charged with R-410A HFC refrigerant• Wired and run tested• Scroll compressors with internal line break overload and high pressure
protection• Model RHPDZR has a single-stage compressor• Models RHPDZS and RHPDZT have two-stage compressor • Convertible airflow – vertical down flow or horizontal side flow• Forkable base rails for easy handling and lifting• Cooling operation up to 125°F ambient• MicroChannel evaporator and condenser coil • PlusOne® ServiceSmart package includes:
Qwik-Change Flex-Fit RackQwik-Slide Blower AssemblyQwik-Clean Drain Pan
• Overflow condensate sensor• PlusOne® Diagnostics with Dual 7-Segment LED Display to meet code
compliance• One-piece top cover and base pan with drawn supply and return
opening • Two-piece control door • ¼ turn fasteners on filter access door • Color-coded and labeled wiring• External lockable gauge ports• TXV refrigerant metering system • Solid-core liquid line filter drier • High pressure and low pressure/loss of charge protection with built in
Smart Logic• Insulation encapsulated throughout entire unit • High performance belt drive motor with variable pitch pulleys and quick
adjust belt system• Variable Frequency Drive (VFD) blower is standard on Model RHPDZT
and optional on model RHPDZS • New product footprint with matching connections• Improved factory lead times
FEATURES FOR RHPD SERIES PACKAGE HEAT PUMP UNITS
-
IllustrationST-A1273-01_D-00
FILTERACCESS PANEL
INDOOR COILACCESS PANEL
33/4�[97 mm]
901/8�[2289 mm]
591/2�[1511 mm]
41/4�[110 mm]
291/4�[743 mm]
323/4�[832 mm]
POWERENTRY
RECEPTACLE
SERVICEPORT DOOR
SUPPLY AIR
RETURNAIR
61/8�[156 mm]
31/2�[89 mm]
371/2�[953 mm]
51/8�[130 mm]
197/8�[505 mm]217/8�
[555 mm]593/8�
[1510 mm]
57/8�[149 mm]
51/4�[133 mm]
15�[381 mm]
291/2�[749 mm]
13�[330 mm]
IllustrationST-A1273-01-F
901/8�[2289 mm]
281/2�[724 mm]
63/4�[171 mm]
51/2�[140 mm]
125/8�[321 mm]
593/8�[1507 mm]
363/8�[224 mm]
263/4�[679 mm]
11/4�[32 mm]
14�[356 mm]
61/2�[165 mm]
41/8�[105 mm]
SUPPLY
RETURN
IllustrationST-A1273-01_A-00
863/4�[2203 mm]
591/2�[1511 mm]
553/8�407 mm]
143/8�[365 mm]
371/2�[953 mm]
2�[51 mm]
TYP. (3) SIDES
IllustrationST-A1273-26-00
RETURN COVER
DRAIN PAN
SUPPLY COVER
ACCESS PANELBLOWER
ACCESS PANELHEAT EXCHANGER
150 MODEL60�
[1524 mm]
090 THRU 120MODELS
50�[1270 mm]
89�[2261 mm]
577/8�[1470 mm]
CONTROL ACCESS
SERVICE DISCONNECTKNOCKOUT
ACCESS PANEL COMPRESSOR
SUPPLY ANDRETURNDIMENSIONSFORDOWNFLOWAPPLICATIONS
SUPPLY AND RETURNDIMENSIONS FORHORIZONTAL APPLICATIONS
[ ] Designates Metric Conversions
Accessory
Economizer w/Single Enthalpy (Downflow)
Economizer w/Single Enthalpy (Horizontal)
Economizer-w/Single Enthalpy (Downflow) DDC
Economizer w/Single Enthalpy (Horizontal) DDC
Dual Enthalpy Kit
Dual Enthalpy Kit DDC
Carbon Dioxide Sensor (Wall Mount)
Power Exhaust
Power Exhaust
Manual Fresh Air Damper
Motorized Fresh Air Damper
Motorized Fresh Air Damper (DDC)
Roofcurb, 14"
Roofcurb, 24"
Roofcurb Adapter
Concentric Diffuser 7.5/8.5 Ton Flush
Concentric Diffuser 10.0 Ton Flush
Concentric Diffuser 12.5 Ton Flush
Concentric Diffuser 7.5/8.5 Ton Drop
Concentric Diffuser 10.0 Ton Drop
Concentric Diffuser 12.5 Ton Drop
Accessory
Concentric Adapter 7.5/8.5 Ton Drop
Concentric Adapter 10 Ton Drop
Concentric Adapter 12.5 Ton Drop
Outdoor Coil Louver Kit - ACD/090/102/120
Outdoor Coil Louver Kit - ACD150
Unwired Convenience Outlet
Unfused Service Disconnect
Comfort Alert (1 Per Compressor)
Comfort Alert (1 Per Compressor)
BACnet Communication Card
LonWorks Communication Card
Room Humidity Sensor
Room Temperature and Relative Humidity Sensor
Low-Ambient Control Kit
Freeze Stat Kit
Variable Frequency Drive Kit**See model number break down below
Electric Heater KitsSingle Point Wiring Kit*
Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices. Rheem Sales Company, Inc.P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 1-19 QG FORM NO. X33-1584
Project Name: Location: Architect: Engineer: Contractor: Submitted By: Date: Quantity 1: Quantity 2: Quantity 3: Quantity 4: Quantity 5: Quantity 6: Unit Designation1: Unit Designation2: Unit Designation3: Unit Designation4: Unit Designation5: Unit Designation6: Model No: 1: 2: 3: 4: 5: 6: :
Total Cooling1: Total Cooling2: Total Cooling3: Total Cooling4: Total Cooling5: Total Cooling6: Sensible Cooling1: Sensible Cooling2: Sensible Cooling3: Sensible Cooling4: Sensible Cooling5: Sensible Cooling6: Air Ent: Evaporator1: Evaporator2: Evaporator3: Evaporator4: Evaporator5: Evaporator6:
Air Lvg: Evaporator1: Evaporator2: Evaporator3: Evaporator4: Evaporator5: Evaporator6:
Heating Input1: Heating Input2: Heating Input3: Heating Input4: Heating Input5: Heating Input6: Heating Output1: Heating Output2: Heating Output3: Heating Output4: Heating Output5: Heating Output6: CFM/ESP1: CFM/ESP2: CFM/ESP3: CFM/ESP4: CFM/ESP5: CFM/ESP6: EER/SEER1: EER/SEER2: EER/SEER3: EER/SEER4: EER/SEER5: EER/SEER6: Electrical1: Electrical2: Electrical3: Electrical4: Electrical5: Electrical6: Minimum Ampacity1: Minimum Ampacity2: Minimum Ampacity3: Minimum Ampacity4: Minimum Ampacity5: Minimum Ampacity6: Min: -Max: Breaker1: Breaker2: Breaker3: Breaker4: Breaker5: Breaker6:
Net Unit Weight1: Net Unit Weight2: Net Unit Weight3: Net Unit Weight4: Net Unit Weight5: Net Unit Weight6: Accessory1: Accessory2: Accessory3: Accessory4: Accessory5: Accessory6: Catalog Form Number1: Catalog Form Number2: Catalog Form Number3: Catalog Form Number4: Catalog Form Number5: Catalog Form Number6: Accessories: Notes: Job Name: Contractor : Engineer : Location : Order No: Approval: OffRecord: OffSubmitted By : Date : Unit Designation: Total Capacity1: Sensible Capacity: Outdoor Design Temperature: Total Supply Air: Temperature of Air Entering: Power Input Requirement: SEER/EER Rating: Heat Pump Capacity 47ºF: Heat Pump Capacity 17ºF: Coefficient of Performance 47ºF: Coefficient of Performance 17ºF: H: S: P: F:
Electric Heat Capacity: Supply Air: External Static Pressure: Blower Speed: Power Output: Motor Rating: Power Input Requirement3: Power Supply: Total Unit Ampacity: Minimum Wire Size: Max Overcurrent Device HACR Circuit Breaker: Total Weight: