submittal mfb-mfl 2-28-13 - titus hvac · mfl-10 25 37 132 154 mfl-15 38 49 183 205 mfl-20 51 62...
TRANSCRIPT
MFL-10 25 37 132 154MFL-15 38 49 183 205MFL-20 51 62 233 256MFL-25 64 75 284 306MFL-30 76 87 335 357
S B W WNModel Slot Border Width WidthWidth Width
H
A S A
W
FlowBarTMArchitectural Ceiling DiffusersAluminum • FlowBar LinearModels: MFL-10 • 25 Slot
MFL-15 • 38 Slot MFL-20 • 51 Slot MFL-25 • 64 Slot MFL-30 • 76 Slot
Submittal
W
SC C
43
59
H
A S B
W
D
SB B
W
5
MFB-MFL 2-28-13
Model MFL-10MFL-15MFL-20MFL-25MFL-30
MFL-10 25 70 22 27 43 41MFL-15 38 95 29 33 43 48MFL-20 51 121 35 40 43 54MFL-25 64 146 41 46 59 NAMFL-30 76 171 48 52 59 NA
Border Type 11 Border Type 33
Model MFL-10MFL-15MFL-20MFL-25MFL-30
W
SA A
43 59
Model MFL-10MFL-15MFL-20
Model MFL-10MFL-15MFL-20MFL-25MFL-30
Model MFL-10MFL-15MFL-20MFL-25MFL-30
Standard HighThrow pattern controller shown.Optional JetThrow pattern controller available as an option.
FlowBar Linear
HighThrow JetThrow
MFB-1.0-S
Border Type 22 Border Type 14
Border Type 13
S
WN
S S
W
B S B
W
S S14
2 CRN33 Border
2 CRB13 Border
2 CRA 33 Border
Optional Two Slot Units
(Please see reverse side.) Dimensions are in millimeters.
S W A B H CModel Slot Width Border Border Height Border
Width Width Width Width
Accessories (Optional) Check if provided
Optional FlowBar Cross
Model MFBRI-10MFBRI-15MFBRI-20MFBRI-25MFBRI-30
Model MFBC-10 MFBC-15MFBC-20MFBC-25MFBC-30
Note: Slot is blanked off
Model MFBR-10MFBR-15MFBR-20MFBR-25MFBR-30
Optional Return Hoods
Note:Return Hoods are 51%free area. Finish is #84black.
AL
W
H
Insulation
64
Uninsulated
Insulated
2
SlotWidth
All dimensions are in millimeters.
Number Slot H of Slots Width (Height)
25 8638 8651 8664 8676 8625 5438 7951 10564 13076 156
1
2
All dimensions are in millimeters.
Optional FlowBar PlenumModel MFBP-10
MFBP-15MFBP-20MFBP-25MFBP-30MFBPI-10MFBPI-15MFBPI-20MFBPI-25MFBPI-30
Plenum LengthW
EarthquakeTab
Internal
VanePressure
254
32
Note: Pressure vane is standard for 1219 and 1524 plenums only.
MFBP-10 70 156 133 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBP-15 95 206 184 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBP-20 121 257 235 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBP-25 146 308 286 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBP-30 171 359 337 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBPI-10 70 156 133 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBPI-15 95 206 184 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBPI-20 121 257 235 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBPI-25 146 308 286 610,914,1219,1524 152,203 254,305 552,857,1162,1467MFBPI-30 171 359 337 610,914,1219,1524 152,203 254,305 552,857,1162,1467
FlowBarUnit
W(Width)Slots
1 2CRN 2CRA 2CRB
NominalLength
StandardAvailable
InletsRnd Oval
Plenum Length(Millimeters)
L
Type 1 Type 3
Number Slotof Slots Width L W A W A
25 375 70 152 79 14838 400 95 152 105 148
1 51 425 121 152 130 148
64 451 146 152 156 148
76 476 171 152 181 148
UHC - Upper Hanger Clip
Hanger & Mounting Clips Check if provided
USH - Upper Support Hanger
H2 - Hard Ceiling Clip H3 - Hard Ceiling Clip H3 - Hard Ceiling Clip
Notes:1. Use only for single slot systems.2. Used for multiple slot systems.3. Only used for type 3 side of rail.4. Used for type 1 rail only.
Suspends the FlowBar assembly from theceiling structure using standard hanger wire.
Suspends one side of the FlowBarassembly from the ceiling structure.
Adjoins multiple sectionsof FlowBar.
Used for mounting Border Types 33or 13 with standard 16 gyp board.
Used for mounting Border Types 11or 13 with standard 16 gyp board.
Used to mount short side of BorderType 14 with standard 16 gyp board.
Can be used to mount border 22 withstandard 16 gyp board.
H4 - Hard Ceiling Clip
Mounts the long side of the FlowBarassembly with type 14 border.
WC1 - Wall Clip
Used for flush mounting bordertypes 33 or 13 to a wall.
WC2 - Wall Clip
Mounts border types 11, 33, or 13 awayfrom a wall when a reveal is required. Thisreveal can be used as a return air slot.
WC3 - Wall Clip
Mounts border 11 or 13 flush to a wall.
SSI - Spline Support Clip(field formed)
Integrates standard drop “Tees”with FlowBar assembly.
Support Border type 11 on Bolt-Slottype suspension systems.
✓
UHC
USH
SC1
SS1
SS1H1
H2 H3 H3
H4
WC1 WC2
WC3
SOUND STOP
SoundStop
3
H1 - Hard Ceiling
SCI - Spline Clip➁
➂
➀
SSI - Connector Clip(as shipped)
➃
23-7/16"
23-7/16"
UHC - Upper Hanger Clip
Hanger & Mounting Clips Check if provided
USH - Upper Support Hanger
H2 - Hard Ceiling Clip H3 - Hard Ceiling Clip H3 - Hard Ceiling Clip
Notes:1. Use only for single slot systems.2. Used for multiple slot systems.3. Only used for type 3 side of rail.4. Used for type 1 rail only.
Suspends the FlowBar assembly from theceiling structure using standard hanger wire.
Suspends one side of the FlowBarassembly from the ceiling structure.
Adjoins multiple sectionsof FlowBar.
Used for mounting Border Types 33or 13 with standard 16 gyp board.
Used for mounting Border Types 11or 13 with standard 16 gyp board.
Used to mount short side of BorderType 14 with standard 16 gyp board.
Can be used to mount border 22 withstandard 16 gyp board.
H4 - Hard Ceiling Clip
Mounts the long side of the FlowBarassembly with type 14 border.
WC1 - Wall Clip
Used for flush mounting bordertypes 33 or 13 to a wall.
WC2 - Wall Clip
Mounts border types 11, 33, or 13 awayfrom a wall when a reveal is required. Thisreveal can be used as a return air slot.
WC3 - Wall Clip
Mounts border 11 or 13 flush to a wall.
SSI - Spline Support Clip(field formed)
Integrates standard drop “Tees”with FlowBar assembly.
Support Border type 11 on Bolt-Slottype suspension systems.
UHC
USH
SC1
SS1
SS1H1
H2 H3 H3
H4
WC1 WC2
WC3
SOUND STOP
SoundStop
3
H1 - Hard Ceiling
SCI - Spline Clip
SSI - Connector Clip(as shipped)
23-7/16"
23-7/16"
All rights reserved. No part of this work may be reproduced or transmitted in any form or any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies
Note: This submittal is meant to demonstrate general dimensions of this product. The drawings on this submittal are not meant to detail everyaspect of the product with exactness. Drawings are not to scale. TITUS reserves the right to make changes without written notice.®605 Shiloh Road • Plano, Texas 75074• 972-212-4800