sugar & carbohydrate analysis - aafco.org · l. tucker aoac 22 pulsed amperometric detector...
TRANSCRIPT
![Page 1: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/1.jpg)
1 L. Tucker AOAC
Sugar & Carbohydrate Analysis
A Practical Perspective
![Page 2: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/2.jpg)
2 L. Tucker AOAC
Liquid Chromatography System
Eluent Pump Injector Column DetectorAuto-Sampler
![Page 3: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/3.jpg)
3 L. Tucker AOAC
Sample Preparation
![Page 4: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/4.jpg)
4 L. Tucker AOAC
Sample Matrix
GrindExtractParticles – FiltrationMatrix elimination – extraction, dialysis, centrifuge, etc…
![Page 5: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/5.jpg)
5 L. Tucker AOAC
Filtration
![Page 6: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/6.jpg)
6 L. Tucker AOAC
Dialysis
Sample in (csmpl)
Sample out
Ion
Ion
Ion
Ion
Ion
Ion
Ion
Ion
Ion
XIon
Ion
Acceptor outcacc < csmpl
Acceptor in
![Page 7: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/7.jpg)
7 L. Tucker AOAC
Dialysis
Sample in (csmpl)
Sample out
Ion
Ion
Ion
Ion
Ion
Ion
Ion
Ion
Ion
XIon
Ion
Acceptorcacc. ~ csmpl
(after 10 min.)
X
X
![Page 8: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/8.jpg)
8 L. Tucker AOAC
Dialysis
•particles
•high molecular weights
•high organic load
•oils
•fats
•proteins
•dyestuffs
![Page 9: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/9.jpg)
9 L. Tucker AOAC
C
Dialysis, dilution 1:100
26155Sucrose8
18820Fructose7
n.d.1
1107Inositol2
n.d.3
n.d.4
n.d.5
19214Glucose6
100 mmol/L NaOH
Metrosep Carb1 – 250 ppm
Carbohydrates: orange juiceCarbohydrates: orange juice
![Page 10: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/10.jpg)
10 L. Tucker AOAC
Dilution 1:1000, dialysis
53Glucose10
35625Lactose11
47Mannose9
52Glycerin1-3
35Inositol4
28Glycerin5
21Xylitol6
6Arabitol7
51Arabinose8
100 mmol/L NaOH
Metrosep Carb1 – 250 ppm
Carbohydrates: milkCarbohydrates: milk
![Page 11: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/11.jpg)
11 L. Tucker AOAC
C
Dilution 1:10, dialysis
1.60Fructose13838.96Lactose14
2.09Xylose12
1.50Inositol30.26Arabitol60.40Sorbitol70.77Mannitol81.29Arabinose101.37Glucose11
100 mmol/L NaOH
Metrosep Carb1 – 250ppm
Anions, pulsed Anions, pulsed amperometric amperometric detectiondetectionCarbohydrates: milk chocolateCarbohydrates: milk chocolate
![Page 12: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/12.jpg)
12 L. Tucker AOAC
Auto-Sampler
Sugars and Carbohydrates fuel biological processesReduce temperature in autosampler to slow / prevent change in samplePeltier cooling or external cooling
![Page 13: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/13.jpg)
13 L. Tucker AOAC
Eluent
Specific for column and separationIsocratic for simple sugarsGradient for complex mixturesFollow manufacturer recommendations
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 min
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
nA
Cell
1
2
3 4
man
nito
l
sucr
ose
arab
inos
ega
lact
ose
gluc
ose
xylo
se man
nose
fruc
tose
Column:METROSEP Carb 1 4X250mm
Eluent: 2.5 mmol/L sodium hydroxide + 0.65 mmol/L sodium acetate in ultrapure water
Post column reagent: 300 mmol/L sodium hydroxide in ultra pure water
![Page 14: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/14.jpg)
14 L. Tucker AOAC
Columns
Choice of vendorsSelectivity/separation neededIsocratic and gradient separations
![Page 15: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/15.jpg)
15 L. Tucker AOAC
Column Selection
Sugar Class Separation Mode
Ligand Exchange +GFCMonosacharides
Disacharides Ligand Exchange +Reversed Phase
Normal Phase
Sacharides & Sugar Alcohols Ligand Exchange +GFC
Ligand Exchange + Normal Phase
Oligosacharides Ligand Exchange +GFC
Amino Sugars Ligand Exchange +GFCNormal Phase
Acidic Sugars Ion ExclusionIon Exchange
Sacharides & Organic Acids Ion Exclusion+GFC
Sugar Alcohols & Organic Acids Ion Exclusion+GFC
![Page 16: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/16.jpg)
16 L. Tucker AOAC
Isocratic Separation
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 min
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
nA
Cell
gluc
ose
fruc
tose
sucr
ose
Sample: Vodka
Column: Metrosep Carb 1 4X150mm
Mobile Phase: 100mM NaOH
Loop: 20uL
Detector: Metrohm PAD
![Page 17: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/17.jpg)
17 L. Tucker AOAC
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 min
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800nA
Cell
rham
nose
man
nose gl
ucos
ega
lact
ose
fruc
tose
lact
ose
sucr
ose
mal
tose
Separation
Sample: Sugar Standards
Column: Metrosep Carb 1
4x250mm
Mobile Phase: 200mM NaOH
Loop: 20uL
Detector: Metrohm PAD
![Page 18: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/18.jpg)
18 L. Tucker AOAC
Separation
![Page 19: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/19.jpg)
19 L. Tucker AOAC
Separation
![Page 20: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/20.jpg)
20 L. Tucker AOAC
Detectors
Refractive IndexPulsed AmperometricMass Spec
![Page 21: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/21.jpg)
21 L. Tucker AOAC
Detectors
Selectivity Sensitivity Cost Separation Refractive Index Little 0.1 to 0.05% Moderate Isocratic
Pulsed Amperometric Some ng/g, ppb Moderate Isocratic, GradientMass Spec Most ng/g, ppb Expensive Isocratic, Gradient
![Page 22: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/22.jpg)
22 L. Tucker AOAC
Pulsed Amperometric Detector
Measuring principleMeasuring principleA defined decent potential is applied to a three electrode system consisting of reference-, working- and auxiliary electrodes. If any oxidizable substance pass these electrodes an oxidation process takes place. A current corresponding to the concentration of therespective substance is measured.
Simple connection to any IC- or HPLC-system
Large variety of electrode materials (glassy carbon, carbon paste, silver, gold, etc.)
Highly sensitive
Very selective
![Page 23: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/23.jpg)
23 L. Tucker AOAC
Mass Spec
Electrospray ionization– Operating temp 250 to 300°C– Sugars oxidize– Form adduct with HCl
HCl Adduct formation– HCl is volatile– Source of Cl¯ for adduction– Post column addition
![Page 24: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/24.jpg)
24 L. Tucker AOAC
Mass Spec
![Page 25: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/25.jpg)
25 L. Tucker AOAC
Mass Spec
![Page 26: Sugar & Carbohydrate Analysis - aafco.org · L. Tucker AOAC 22 Pulsed Amperometric Detector Measuring principle A defined decent potential is applied to a three electrode system consisting](https://reader030.vdocument.in/reader030/viewer/2022040418/5d66aa4588c99389388ba24b/html5/thumbnails/26.jpg)
26 L. Tucker AOAC
Summary
You have choices in hardware and separationChoose the right tools for your applicationWhat do you need?