the ECH advantage in-lab | mobile | on-line | process H S determination in solid and pasty samples 2 Product description H S Headspace Module for coupling to Sulfimax GX 2 analysis systems of ECH Sulfimax GX Go with connected Headspace Module Applications The sample is filled into a glass vial and heated in the headspace module. Depending on the sample type, the heating temperature can be varied from 30 to 180 °C. The volatile H S is transported 2 through the gas circulation to the sensor in the Sulfimax GX and measured there. Very low H S concentrations are detectable. 2 Sample preparation is not necessary. The determination of volatile hydrogen sulphide (H S) in solid 2 and pasty samples is now very easy. The selective H S analysis 2 system Sulfimax GX of the ECH is extended with a manual headspace module. Due to the short determination times, high sample throughputs are possible. The compact and robust device can be easily operated by anyone. H S Headspace Module 2 sulfimax GX · solid samples, e. g. elementary sulphur, sludge, bitumen, · pasty samples, · liquid samples such as wastewater with sludge particles, H S analysis systems from ECH, coupled with the Headspace 2 Module allow the measurement of: · soil samples and waste Advantages · Very low H S concentrations detectable 2 · No sample preparation necessary for solid samples · Manually operated and robust measuring system · Easy handling for everyone · Easy connection to the Sulfimax GX Lab and Go Analysis of solid and pasty samples containing H S 2

Upload: others

Post on 09-Jan-2022

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: sulfimax headspace module

the ECH advantage in-lab | mobile | on-line | process

H S determination in solid and pasty samples2

Product description

H S Headspace Module for coupling to Sulfimax GX 2

analysis systems of ECH

Sulfimax GX Go with connected Headspace Module

Applications

The sample is filled into a glass vial and heated in the headspace

module. Depending on the sample type, the heating temperature

can be varied from 30 to 180 °C. The volatile H S is transported 2

through the gas circulation to the sensor in the Sulfimax GX

and measured there. Very low H S concentrations are detectable. 2

Sample preparation is not necessary.

The determination of volatile hydrogen sulphide (H S) in solid 2

and pasty samples is now very easy. The selective H S analysis 2

system Sulfimax GX of the ECH is extended with a manual

headspace module.

Due to the short determination times, high sample throughputs

are possible. The compact and robust device can be easily

operated by anyone.

H S Headspace Module2

sulfimax GX

· solid samples, e. g. elementary sulphur, sludge, bitumen,

· pasty samples,

· liquid samples such as wastewater with sludge particles,

H S analysis systems from ECH, coupled with the Headspace 2

Module allow the measurement of:

· soil samples and waste

Advantages

· Very low H S concentrations detectable2

· No sample preparation necessary for solid samples

· Manually operated and robust measuring system

· Easy handling for everyone

· Easy connection to the Sulfimax GX Lab and Go

Analysis of solid and pasty samples containing H S2

Page 2: sulfimax headspace module

ECH Elektrochemie Halle GmbH

Otto-Eißfeldt-Str. 8

D-06120 Halle (Saale)

Germany

Building 69, Wrest Park, Silsoe

Bedfordshire, MK45 4HS

United Kingdom

ECH Scientific Limited

Tel.: +49 (0) 345 279570-0

Fax: +49 (0) 345 279570-99

Tel.: +44 (0) 1525 404747

Fax: +44 (0) 1525 404848

Email: · www.ech.de · [email protected]

the ECH advantage

SCIENTIFICpart of ECH Elektrochemie Halle

Global Sales Division

in-lab | mobile | on-line | process

210

001

Features and Results

Sealed sample vial in the Headspace Module

· Bypass circuit for continuous gas flow

· Measuring time from 2 to approx. 15 min, depending on the H S content 2

of the sample

· Measurement of the sample in the sealed 20 ml vial - no contact of the

sample with components of the analysis system

· Temperature control from 30 to 180 °C

· Double-needle system for gas transfer

· Gas extraction technique for rapid release and separation of H S from 2

the sample

Technical specificationsSample type:

Sample volume:

Heating temperature:

Temperature resolution:

Heating method:

Dimensions:

Power input:

Weight:

Power supply:

100 W

130 x 270 x 290 mm (W x H x D)

5 kg

230 V

solid, pasy and high viscous

0.01 ... 20 mL (g)

30 ... 180 °C

0.1 °C

isothermally

Determination of volatile H S from bitumen by headspace technique2

Sulfimax GX Lab with coupled H S Headspace Module 2

and autosampler for liquid samples