sulfimax headspace module
TRANSCRIPT
the ECH advantage in-lab | mobile | on-line | process
H S determination in solid and pasty samples2
Product description
H S Headspace Module for coupling to Sulfimax GX 2
analysis systems of ECH
Sulfimax GX Go with connected Headspace Module
Applications
The sample is filled into a glass vial and heated in the headspace
module. Depending on the sample type, the heating temperature
can be varied from 30 to 180 °C. The volatile H S is transported 2
through the gas circulation to the sensor in the Sulfimax GX
and measured there. Very low H S concentrations are detectable. 2
Sample preparation is not necessary.
The determination of volatile hydrogen sulphide (H S) in solid 2
and pasty samples is now very easy. The selective H S analysis 2
system Sulfimax GX of the ECH is extended with a manual
headspace module.
Due to the short determination times, high sample throughputs
are possible. The compact and robust device can be easily
operated by anyone.
H S Headspace Module2
sulfimax GX
· solid samples, e. g. elementary sulphur, sludge, bitumen,
· pasty samples,
· liquid samples such as wastewater with sludge particles,
H S analysis systems from ECH, coupled with the Headspace 2
Module allow the measurement of:
· soil samples and waste
Advantages
· Very low H S concentrations detectable2
· No sample preparation necessary for solid samples
· Manually operated and robust measuring system
· Easy handling for everyone
· Easy connection to the Sulfimax GX Lab and Go
Analysis of solid and pasty samples containing H S2
ECH Elektrochemie Halle GmbH
Otto-Eißfeldt-Str. 8
D-06120 Halle (Saale)
Germany
Building 69, Wrest Park, Silsoe
Bedfordshire, MK45 4HS
United Kingdom
ECH Scientific Limited
Tel.: +49 (0) 345 279570-0
Fax: +49 (0) 345 279570-99
Tel.: +44 (0) 1525 404747
Fax: +44 (0) 1525 404848
Email: · www.ech.de · [email protected]
the ECH advantage
SCIENTIFICpart of ECH Elektrochemie Halle
Global Sales Division
in-lab | mobile | on-line | process
210
001
Features and Results
Sealed sample vial in the Headspace Module
· Bypass circuit for continuous gas flow
· Measuring time from 2 to approx. 15 min, depending on the H S content 2
of the sample
· Measurement of the sample in the sealed 20 ml vial - no contact of the
sample with components of the analysis system
· Temperature control from 30 to 180 °C
· Double-needle system for gas transfer
· Gas extraction technique for rapid release and separation of H S from 2
the sample
Technical specificationsSample type:
Sample volume:
Heating temperature:
Temperature resolution:
Heating method:
Dimensions:
Power input:
Weight:
Power supply:
100 W
130 x 270 x 290 mm (W x H x D)
5 kg
230 V
solid, pasy and high viscous
0.01 ... 20 mL (g)
30 ... 180 °C
0.1 °C
isothermally
Determination of volatile H S from bitumen by headspace technique2
Sulfimax GX Lab with coupled H S Headspace Module 2
and autosampler for liquid samples