Summary of Undersea Fiber Optic Network Technology and Systems

By Adam Markow

Senior Telecom Analyst

The source of many of the slides is from – The David Ross Group http://www.davidrossgroup.com

Page 2: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

A view of the Global Submarine Cable Network (TeleGeography)

Page 3: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea System ElementsRepeatered Examples

Repeaters

Branching Unit

SubmarineCable

TerminalStations

Transoceanic Network Coastal NetworkUsing the same elements

Page 4: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea System Elements - Non-Repeatered Examples

Inter-island NetworkSubmarine

Cable

TerminalStations

Coastal NetworksUsing the same elements

Trunk & Branch Festoon

Repeaterless vs. Repeatered:

• Limited to <400 km span lengths

• Sometimes, but not always• Less expensive initially• More flexible long term• Less expensive to operate & maintain• More complex to upgrade

• Historical advantages of repeaterless offset today by current market oversupplyof repeatered production capability and inventory

The choice between repeatered & repeaterlessmust be made on a case by case basis

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 5: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

.

.

OceanCable

PFE

SLTE

Shore Section

Connecting a Terrestrial Network with and Undersea System

N x STM-1o

Telehouse

SLTE – Submarine Line Termination Equipment.PFE – Power Feed Equipment (pushes constant

current of ~1.5 A across undersea cable link from CS to CS)

Ocean ground

BackhaulConnection

N x STM-64

)

ADM

ADM

Cable Station & Beach Manhole

ADM

Page 6: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Cable Station Floor Plan

GCL Cable Station Requirements:

At least 17,000 square feet (~1900m2 ) of total areaRaised floor, with minimum load tolerance of 500 kg/m2

Useable height of at least 2.5mDual cable vaultsDC -48v power, with battery backup for at least 1 hour.Diesel Engine emergency backupHVAC to maintain room temperature between 22 - 24CRing GroundFire/smoke detection, with connection to emergency/control center24 hour access for maintenance and repair

Transmission EquipmentCollocation for backhaulMeeting/training room

Battery

Page 7: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Cable Station Transmission Components

LINE PAIR #1

LINE PAIR #4

OpticalConnections

of Terrestrial Link

connecting to Data Center

LineMonitoringEquipment

Undersea Cable

LineCurrent

PowerFeed

Equipment

���

Orderwire & Maintenance

SDHTerminal

CableStation

SLTE

Orderwire & Maintenance

SDHTerminalSLTE

Page 8: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Line Terminating Equipment

λ

OpticalLineToUndersea Cable

Line Amplifier

DWDMWavelength TerminatingEquipment

HighPerformanceOpticalEquipment

ToSDHEquipment

λ

λλ 1- N

N

2

1

Page 9: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Line Terminating Equipment

Source – NEC

ORX Shelf

STM-16 Timing GeneratorOHTRM

FECDECODER

OH

Timing GeneratorOHTRM

FECDECODER

OH

Timing GeneratorOHTRM

FECDECODER

OH

10G SORX

WME10.8G

Timing GeneratorOHTRM

FECDECODER

OHFEC DEC

DMUXFRMSYNC

&DSCR

DSCR DMUX

CONV.O/E

E/OCONV.

2.5G OTXE/OCONV.

2.5G OTXE/OCONV.

2.5G OTXE/OCONV.

2.5G OTX

STM-16

STM-16

STM-16

STM-16WME10.8G

OTX Shelf

OHINS

TIMING GENERATOR

FECENCODER

OH

OHINS

TIMING GENERATOR

FECENCODER

OH

OHINS

TIMING GENERATOR

FECENCODER

OHOHINS

FECENCODER

OHFEC COD

10G SOTX

CONV.E/O

MUXSCR

SCR MUX

O/ECONV.

2.5G ORXO/ECONV.

2.5G ORXO/ECONV.

2.5G ORXO/ECONV.

2.5G ORX

STM-16

STM-16

STM-16

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 10: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – SDH Ring Terminal

Optical Line ToUndersea Cable

Line Amplifier

WavelengthTerminatingEquipment

High PerformanceOptical Equipment

NetworkProtectionEquipment

SDH MultiplexEquipment

Duplicated Per Fiber Pair

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 11: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Network Management Equipment

Power Feed Equipment

Line MonitoringEquipment

Undersea Line Equipment

TLA

WTE

HPOE

SDH

Inland Network (optional)

Vendor Equipment Element Managers

Network ManagementSystem Equipment

Network ManagementSystem Workstation

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 12: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Power Feed Equipment

HV PFE Configuration

PR1800 mm

CONV(4)

CONV(3)

CONV(2)

COM

CONV(5)

CONV(1)

PR2

800 mm

CONV(9 )

CONV(8)

CONV(7)

COM

CONV(6)

PM

800 mm

CURR CONT

& C/V SENSOR

LT

800 mm

LOAD TRF

COMN

SW

800 mm

SW&RETURN

&

EARTH TEST

TL2TL1

800 mm

FAN

TEST LOAD

800 mm

TEST LOAD

FAN

RECORDER

OPE & MONI

1,800 mm

*The depth of the frame: 600mm

BLANK

Source – KDD SCS

Page 13: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Cable Station and Beach Manhole2025 Taft Street - Hollywood, Florida

Page 14: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

The optronic connection that starts at Optical Distribution Frame (ODF) in the Cable Station and then continues to the ODF at the City Service Point, the Telehouse.

Then a separate connection of the circuit is made to the frame of the carrier who will then take traffic back to the end customer premise.

Global Crossing Backhaul in Hollywood, Florida

Cable Station

Page 15: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Cable Landing Configuration

•Submerged Plant•Beach Manhole•Shore Section•Land Sections •Terminal Station•Terminal Station Equipment Land SectionLand Section

Beach ManholeBeach Manhole

Terminal StationTerminal Station

Power FeedPower FeedEquipmentEquipment

Optical & Optical & TransmissionTransmissionEquipmentEquipment

RepeaterRepeater

CableCable

Network Network ManagementManagement

Branching UnitBranching Unit

Page 16: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Yes, the cable really does rest on the Ocean Floor!

Cable Ship

Repeater

Submarine Mountain

Submarine Cable

Page 17: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

• South America Physical Map• South America ERZ border at 12 nmi• South American Crossing Segments

are mostly outside of the ERZ

ERZ = Economic Resource Zone

Page 18: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Installing a Submarine Cable System

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 19: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

CS Long Lines

LONG LINESYEAR OF BUILD: 1963LENGTH: 155.91’BREADTH: 21.19’DRAUGHT: 8.17’DEPTH: 13.87’FLAG: UNITED STATES OF AMERICASHIPBUILDER: DEUTSCHE WERFT HAMBURGCOUNTRY OF BUILD: FEDERAL REPUBLIC OF GERMANYSTATUS: IN SERVICE/COMMISSION

Page 20: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Cable Ship Profile – Tyco Telecom

Page 21: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

G1294 28

Cable Laying and Burial

Page 22: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Phases of Cable System Network

Planning, Finance & Procurement

– Carrier Partnership– Business Plan– Preliminary Network

Design & Desktop study– Finance– Procurement– Survey– Route engineering– Network engineering

Deployment– License & Permits– Terminal Station Construction– Manufacturing- Undersea and

Land Plant– Undersea Plant Assembly &

Load– Undersea Installation

– Shore end and cable burial– Deep water i– Branching unit– Final Splice

– Terminal Station Installation– Commissioning & Acceptance– Service

Service, Operations & Maintenance

– System Provisioning– Station & NOC Operations – Cable Maintenance

agreement (Cable recover, splicing, repair, relay, rebury)

– Network Upgrades

Survey Vessel

Installation Ship

Sea Plow for CableBurial Operation

Maintenance Vessel

Page 23: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

St. Croix Shore End - SAC,2000

After years and years…

Page 24: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

If the cable should break, the cable must be hooked…

Page 25: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant

• Land Cables

• Terminal Stations

Page 26: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Land Cables

High DensityPolyethyleneJacket

Copper/Stainless SteelBimetal Armor

Core Tube

Filling Compound

Lightpack Fiber Bundle4-48 Fibers

TM

Color Coded Binder

Helical Lay WireStrength Members

Fiber Cable

Source - Tycom

Page 27: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Land Cables

Polyethylene JacketPolyethylene JacketCopper TapeCopper TapeSemiconductor LayerSemiconductor LayerInsulationInsulation

Strand ScreenStrand Screen

#6 Copper Conductor#6 Copper Conductor

Power Cable

Source - Tycom

Page 28: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Land Plant – Terminal Station Equipment

• Line Terminating Equipment– High Performance Optical Equipment– Wavelength Terminating Equipment– Line Amplifiers

• SDH Network Protection Equipment• SDH Multiplex Equipment • Line Monitoring Equipment • Network Management Equipment • Power Feed Equipment• Synchronization Equipment• Test Equipment

Page 29: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Terminal Stations

• Typically terminate undersea signals, and interface with domestic network

• Most often very close to beach• Construction & features very similar to other telecom offices,

such as Central Offices, but include some unique aspects• In multi-point coastal systems, costs can become significant

element of network cost.• Large stations cost $10-$15M. Very small stations <$5M.• Permissions and Rights Of Ways associated with construction

and beach access, plus actual civil construction, together often dominate overall network construction schedule

• In small, regional networks, alternate more efficient options (prefabricated huts) may be possible

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 30: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant

• Cable and Fiber

• Repeaters

• Equalizers

• Branching Units

• Marine Installation

Page 31: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant

• Cable and Fiber– Specified for each span of each system

– Typically 1 to 4 types of cable depending on type of environmental protection needed

– Typically 1 to 3 types of fiber depending on required management of optical transmission properties

– Network costs vary widely depending on types of cable (increase dramatically in vulnerable areas)

Page 32: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Submarine Fiber Cables

Page 33: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Comparison of Coaxial and Fiber Optics Cable

Page 34: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Optical CableTyco “Standard” design < 2000

OPTICALFIBER

UNITFIBER

STRUCTURE

STRENGTHWIRES

COPPERSHEATH

INSULATIONJACKET

ARMORED PROTECTIONLAYER

Page 35: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Cable Types

Rock Armor

SPA(Special Purpose

Armor)LWA

(Light Wire Armor)

SA(Single Armor)

DA-HS (Double Armor,High Strength)

DA-HA(Double Armor,

High Impact)

LW(Lightweight)

Source – Tycom

Page 36: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Various Cables and ApplicationsVarious Cables and Applications

• Undersea Cable Types:

• Power & Ground Cable

• Land Cable

Undersea CableDouble Armored (DA)Single Armored (SA)Light-Wire Armored (LWA)Special Application* (SPA)Light Weight (LW)

Typical ApplicationBeach Joint to 400 Meter Depth400 to 900 Meter DepthBuried900-2,000 Meter Depth>2,000 Meter Depth

*Fish Bite Protected Cable

Page 37: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – LW Cable

• Lightweight cable– Used in deep water where hazards are

minimal– Comes in three outer diameters

• 10-12 mm, used in non-repeatered systems• 17-19 mm, used in several recent repeatered

systems• 21-23 mm, used in repeatered systems wherever

the additional size is deemed necessary or desirable

– Cost varies in proportion to size.

Page 38: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Armored Cable

• Armored cable– Used in shallower water where hazards from abrasion, fishing

activity or anchors warrant– Comes in several varieties

• SPA, for light abrasion or “fishbite” protection• LWA, for harsher abrasion• SA, for light marine activity• DA, for heavier marine activity• Rock armor, for the most challenging environments

– Specified jointly by supplier, installer, and purchaser– Armor is costly, takes more time to produce, load, lay– Result: systems in difficult environments cost much more

Page 39: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant- Repeaters

• Repeater– Performance designed to match needs of system– Two sizes presently available

• 1 to 4 fiber pair• 5 to 8 fiber pair

– One optical amplifier per fiber– Costs strongly dependent on number of fiber pair – Cost also dependent on performance– Spacing (between repeaters) set for system performance / cost,

and typically 50-80km– Shorter spacing generally yields higher ultimate capacity – In long (many thousand km) systems, often largest single

component network cost

Page 40: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Repeater

Approx . 1300

Appr ox . 1500 Appr ox . 1400 Appr ox . 1500

Appr ox . 4400

Cab l e Termi na t i onCab l e Termi na t i on

Repea t e r Hous i ng

Ta i l Cabl e Cab l e

(be tween PIN t o PIN)

(Repea t er Hous ing)

Be l l ows

Approx.∅265

Approx.∅250

Approx.∅230

Source - NEC

Page 41: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Repeater

Amplifier Pair Chassis

Pump UnitControl Circuit

Erbium Amplifiers

Supervisory

Heat Transfer Plate

Locking Plate

Power Supply

4 Amplifier Pair Repeater

Source – Tycom

Page 42: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

TSSL Repeater < 2000

Laser PumpDriver

Optical AmplifierPair

RepeaterHousing

Cable to RepeaterCoupling

Repeater EndCover

69cm(27”)

33cm(13”)

Page 43: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant

• Equalizer– Performance designed to match needs of

system– Inserted at periodic intervals as needed – One equalizer per fiber– Cost strongly dependent on number of fiber

pair– Higher capacity systems generally require

more exotic equalization

Page 44: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Equalizer

Source - NEC

Pressure Housing

Equalizer Module

Cable Coupling

Page 45: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant

• Branching Unit– All currently produced are three-terminal– One or more fiber pair may be branched– Fiber connections or powering may be switchable

from a shore terminal or NOC for restoration or security

– Wavelength branching (Optical Undersea Add-Drop Mutiplexing) has been done on a limited basis

– Cost is strongly dependent on degree of complexity and number of fiber pair

Page 46: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant – Branching Unit

Source - NEC

Cable Termination

Cable Termination

Bellows

Tail Cable

Branching Unit

(Pressure Housing)

Gimbval Joint

(Dimensions in mm)

Branching Unit With Cable 

48

0 

di

a.

Ap

pr

ox

 Terminations

Cable

Approx.4600

Approx.1260 1700

1700

Approx.1245

Approx. 4600

Cable TerminationApprox. 1245

Housing Unit(Pressure Housing)

Gimbal Joint

1700

CableTail Cable

Approx. 1260

Cable TerminationBellows

Approx.φ 480

1700

Page 47: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Undersea Plant

• Marine Installation– Uses specially designed cable-laying vessels and

tools– Costs strongly dependent on

• Water depth• Types of cable and protection employed• Bottom characteristics• Burial depth required• Number of shore landings and branching units• Number of cable and pipeline crossings• Distance of lay from cable factory • Weather

Page 48: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Deployment Timeline –Economies to Be Achieved

Traditional Procurement Cycle

Network Planning

DesktopStudy

Survey Procurement

SupplyProcurement &

Contract

Survey

System Manufacture

SystemInstallation

OperationsReadiness

Testing

Typical 2 Year TimelineFinancing

Source – The David Ross Grouphttp://www.davidrossgroup.com

Page 49: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Primary Network Construction Elements

• Wet Plant

• Dry Plant

• Terminal Stations & Backhaul

• Marine Work

• Network Operations Center

Page 50: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Network Construction Cost& Payment Schedule

• Typical Network Costs (1998-2001): $30-40K/km, plus stations

• Today’s Discounted Network Costs, with Market Oversupply: $20K/km, plus stations

• Work Typically Begins with secure finance, followed by secure supply contract– 5-10% down payment– Periodic milestone-based progress payments during construction period,

cumulating to 75-85% before service begins– Additional 10-15% at start of service– Last 5-10% at final acceptance months thereafter

• Work might begin earlier via an ITP IF purchaser guarantees payment for all supplier expenses prior to secure contract

Today’s oversupply market offers huge discounts for purchasers,but minimal opportunities for vendor finance

Page 51: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Costs After the Initial Installation

• Operation and Administration

• Maintenance and Repair

• Network Upgrades

Page 52: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Costs After the Initial Installation

• Operation and Administration– In consortium and domestic systems, operation

handled by experts landing-party carriers.– In private systems, operation provided by carriers’

carriers or outsourced to suppliers.– Involves staff at cable stations and the Network

Operations Center (if any).– Functions involve provisioning, troubleshooting,

monitoring performance, and billing.– For domestic undersea networks, processes can

readily be integrated with similar processes for other land & satellite-based elements of the carrier’s complete network

Page 53: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Costs After the Initial Installation

• Maintenance and Repair– Dry maintenance and repair handled by operations staff and

suppliers.– Wet maintenance and repair handled by Cable Maintenance

Authorities under Cable Maintenance Agreements. – CMAs employ ships, spares, and skilled personnel on standby

to do repairs on any cable within the agreement. – CMAs are specific to geographic regions, e.g. Atlantic, Pacific

and Indian Ocean, etc.– Costs of CMAs typically depend on length of system and

number of landings, as drivers of expected number of repairs. – Per-network costs are greatly dependent on the number of

networks covered in the CMA sharing its expense.– Wet maintenance costs have dropped dramatically from 2001-

2003 as a consequence of an excess of cable ships, but remain millions (US$) annually

Page 54: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Costs After the Initial Installation

• Network Upgrades– Network upgrades to increase capacity by adding

wavelengths are planned and contracted (price-capped) at the time of the initial system construction.

– Typically, but not always, the same supplier installs and upgrades the network

– Terminal stations must be sized for the ultimate capacity of the system, often requiring tens of thousands of square feet.

– In high-capacity WDM systems, upgrading to the ultimate design capacity may take many years, and will often cost more than the initial undersea system installation.

– Since technology and prices change over time, purchasers often obtain better prices (than originally contracted) at the time they are needed

Page 55: Summary of Undersea Fiber Optic Network Technology and … of submarine system installation and... · Cable Station Floor Plan GCL Cable Station Requirements: At least 17,000 square

Life-Cycle Costs

ConstructionBegins with ITP

Finance&

SupplyContractClosure

ConstructionMilestone Payments Service

Operations,And Maintenance

Begin

FinalAcceptance

$

Supply& OA&MContract

Cost

100%

Revenue

Net Cash Flow-Break-evenDependent

On Demand &Revenue

Cumulative Costs

Possible RevenueProjection

(further study required)

FirstRevenue

Time