summit x670 series - homeyen · summit x250e series make your network mobile ... a single point of...

15
Extreme Networks Data Sheet Summit X250e Series Make Your Network Mobile Target Applications Edge Power over Ethernet (PoE) and non-PoE switch providing intelligent 10/100BASE-T connectivity to the desktop in a network running ExtremeXOS from the core to the edge Carrier Ethernet edge switching with 100BASE-X provides advanced fiber connectivity to the customer for both AC and DC powered environments Voice-Class Availability Modular ExtremeXOS operating system Ethernet Automatic Protection Switching (EAPS) resiliency protocol SummitStack™—highly available, high-speed stacking support Designed for Converged Network Applications Quality of Service (QoS) with advanced traffic management capabilities for converged applications Convergence-ready connectivity with Voice-over-IP (VoIP) automatic provisioning with Universal Port capability Comprehensive network management Comprehensive Security User policy, host integrity enforcement and Identity Management Extensive MAC and IP security functionality to help prevent man-in-the-middle attacks Universal Port dynamic security profile to provide fine granular security policy in the network Common Criteria EAL3+ Certification Highlights Summit® X250e series switches are based on Extreme Networks® revolutionary ExtremeXOS® core-class operating system. ExtremeXOS is a highly resilient, modular operating system that helps provide continuous uptime, manageability and operational efficiency at an affordable price. Summit X250e provides high availability and performance with its advanced traffic management capabilities. Summit X250e supports the large-scale rollout of a converged network with devices such as IP telephones, wireless access points and other devices that require power from a LAN connection. Summit X250e-24x supports Carrier Ethernet edge deployment with its flexible fiber connectivity options. Summit X250e-24x can support 100BASE-FX, 100BASE-LX10 and 100BASE-BX on its SFP ports depending upon deployment requirements. Summit X250e supports hardware-based routing for both IPv4 and IPv6 to help provide investment protection by allowing the rollout of IPv6 in your network now or in the future. The flexible Summit X250e switch provides high-density Fast Ethernet ports plus dedicated 40 Gbps high-speed stacking ports in a compact 1RU format, supporting a full range of Layer 2 to Layer 4 functionality on every port for high productivity. Optional redundant power supplies are available for each switch to help secure against power anomalies. Technical Specifications

Upload: ngohanh

Post on 27-Jul-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Extreme Networks Data Sheet

Summit X250e Series

Make Your Network Mobile

Target Applications• EdgePoweroverEthernet(PoE)andnon-PoEswitchprovidingintelligent

10/100BASE-TconnectivitytothedesktopinanetworkrunningExtremeXOSfromthe

coretotheedge

• CarrierEthernetedgeswitchingwith100BASE-Xprovidesadvancedfiberconnectivity

tothecustomerforbothACandDCpoweredenvironments

Voice-Class Availability• ModularExtremeXOSoperatingsystem

• EthernetAutomaticProtectionSwitching(EAPS)resiliencyprotocol

• SummitStack™—highlyavailable,high-speedstackingsupport

Designed for Converged Network Applications • QualityofService(QoS)withadvancedtrafficmanagementcapabilitiesfor

convergedapplications

• Convergence-readyconnectivitywithVoice-over-IP(VoIP)automaticprovisioning

withUniversalPortcapability

• Comprehensivenetworkmanagement

Comprehensive Security• Userpolicy,hostintegrityenforcementandIdentityManagement

• ExtensiveMACandIPsecurityfunctionalitytohelppreventman-in-the-middle

attacks

• UniversalPortdynamicsecurityprofiletoprovidefinegranularsecuritypolicyin

thenetwork

• CommonCriteriaEAL3+Certification

HighlightsSummit®X250eseriesswitchesarebased

onExtremeNetworks®revolutionary

ExtremeXOS®core-classoperatingsystem.

ExtremeXOSisahighlyresilient,modular

operatingsystemthathelpsprovidecontinuous

uptime,manageabilityandoperational

efficiencyatanaffordableprice.

SummitX250eprovideshighavailability

andperformancewithitsadvancedtraffic

managementcapabilities.SummitX250e

supportsthelarge-scalerolloutofaconverged

networkwithdevicessuchasIPtelephones,

wirelessaccesspointsandotherdevices

thatrequirepowerfromaLANconnection.

SummitX250e-24xsupportsCarrierEthernet

edgedeploymentwithitsflexiblefiber

connectivityoptions.SummitX250e-24xcan

support100BASE-FX,100BASE-LX10and

100BASE-BXonitsSFPportsdependingupon

deploymentrequirements.

SummitX250esupportshardware-based

routingforbothIPv4andIPv6tohelpprovide

investmentprotectionbyallowingtherollout

ofIPv6inyournetworknoworinthefuture.

TheflexibleSummitX250eswitchprovides

high-densityFastEthernetportsplus

dedicated40Gbpshigh-speedstacking

portsinacompact1RUformat,supportinga

fullrangeofLayer2toLayer4functionality

oneveryportforhighproductivity.Optional

redundantpowersuppliesareavailable

foreachswitchtohelpsecureagainst

poweranomalies.

Technical Specifications

2

Extreme Networks Data Sheet: Summit X250e Series Technical Specifications

Voice-Class Availability

Modular Operating System for High Availability Operation

Preemptive Multitasking and Protected Memory

SummitX250eswitchesalloweachofmanyapplications—suchasOpen

ShortestPathFirst(OSPF)andSpanningTreeProtocol(STP)—torunas

separateOperatingSystem(OS)processesthatareprotectedfromeach

other.Thisdrivesincreasedsystemintegrityandhelpsprotectagainst

DenialofService(DoS)attacks.

Process Monitoring and Restart

ExtremeXOSimprovesnetworkavailabilityusingprocessmonitoringand

restart.EachindependentOSprocessismonitoredinrealtime.Ifaprocess

becomesunresponsiveorstopsrunning,itcanbeautomaticallyrestarted.

Loadable Software Modules

ThemodulardesignoftheExtremeXOSOSallowstheupgradingof

individualsoftwaremodules,shouldthisbenecessary,leadingtohigher

availabilityinthenetwork(seeFigure1).

High Availability Network Protocols

Ethernet Automatic Protection Switching (EAPS)

EAPSallowstheIPnetworktoprovidethelevelofresiliencyanduptime

thatusersexpectfromtheirtraditionalvoicenetwork.EAPSdiffersfrom

SpanningTreeorRapidSpanningTreeprotocolsandofferssub-second

(lessthan50milliseconds)recoverythathelpsdeliverconsistentfailover

regardlessofthenumberofVLANs,networknodesornetworktopology.

SinceEAPSallowsthenetworktorecoveralmosttransparently,VoIPcallswill

notdropanddigitalvideofeedswillnotfreezeorpixelizeinmostsituations.

Spanning Tree/Rapid Spanning Tree Protocols

SummitX250eswitchessupportSpanningTree(802.1D),PerVLAN

SpanningTree(PVST+),RapidSpanningTree(802.1w)andMultiple

InstancesofSpanningTree(802.1s)protocolsforLayer2resiliency.

Software-Enhanced Availability

Software-enhancedavailabilityallowsuserstoremainconnectedtothe

networkevenifpartofthenetworkinfrastructureisdown.SummitX250e

switchescontinuouslycheckforproblemsintheuplinkconnectionsusing

advancedLayer3protocolssuchasOSPF,VRRPandExtremeStandby

RouterProtocol™(ESRP,supportedinLayer2orLayer3),anddynamically

routetrafficaroundtheproblem.

Equal Cost Multipath Routing

EqualCostMultipath(ECMP)routingallowsuplinkstobeloadbalancedfor

performanceandcostsavingswhilealsosupportingredundantfailover.If

anuplinkfails,trafficisautomaticallyroutedtotheremaininguplinksand

connectivityismaintained.

Link Aggregation (802.3ad)

Linkaggregationallowstrunkingofuptoeightlinksonasinglelogical

connection,forupto2GigabitsperSecond(Gbps)ofredundant

bandwidthperlogicalconnection.

Multi-Switch LAG (M-LAG)

M-LAGcanaddressbandwidthlimitationsandimprovenetworkresiliency,

inpartbyroutingnetworktrafficaroundbottlenecks,reducingtherisksof

asinglepointoffailure,andallowingloadbalancingacrossmultipleswitches.

Voice-Grade Stacking with SummitStackSummitX250eoffersdualstackinginterfacestoprovidehigh-speed40

Gbpsstackingbandwidth.SummitStackarchitectureisdesignedtosupport

convergedservicesbyitshighlyavailable,rapidfailovercapabilitywithn-1

masterredundancy,distributedLayer2andLayer3switching,link

aggregationacrossthestackanddistributeduplinks.SummitStack

supportsuptoeightunitsinastack(themixtureoftheunitscanbe

SummitX250e,X450e,X450a,X460,X480andX650seriesswitches

runningthesameversionofExtremeXOS)andprovidessub-second

failoverforpathfailureandhitlessmaster/backupfailoveralongwithhitless

protocolsupportsuchasOSPFgracefulrestart,PoEconfigurationand

NetworkLoginuserauthentication.

SummitX250eprovideschassis-likemanagementandavailabilitywithits

SummitStackstackingtechnology(seeFigure2).

5027-06

• Processes are monitored and can be restarted or other action taken if necessary

• Hitless failover infrastructure for dual management systems and stacking

Memory protected processes under

real-time scheduling that cannot impact each other nor

kernel

1Designed to allow

application modules to be

upgraded during runtime

3

Application modules can be added during

runtime

2

SSH-2 V1.3.2

BGP OSPFThirdParty

ApplicationSSH-2 V1.3.1

ExtremeXOS®Kernel

Kernel LoadableModule

Figure 1: ExtremeXOS Modular Design

5251-03

• Single management point for up to eight units• High-speed 40 Gbps stacking• Rapid Failover for converged applications• Can mix Summit® X250e, Summit X450a/e series, Summit X460, Summit X480 and Summit X650 series switches for SummitStack™ 40 Gbps stacking

Figure 2: SummitStack Stacking Architecture

3

Extreme Networks Data Sheet: Summit X250e Series Technical Specifications

Designed for High-Performance Network Application

Exceptional Policy-based QoS with Advanced Traffic Management for Converged Applications

SummitX250eprovideseighthardwarequeuesperporttosupport

granulartrafficclassificationwithbandwidthallocation.1,024centralized

classifiersper24-portblockcanuseinformationfromLayers1through4to

prioritizeandmeterincomingpacketsatline-rate.Whenmeteringtraffic,

theswitchescandropout-of-spectrafficorflagitforlateraction.To

expediteupstreamtraffichandling,apacket’sclassificationcanbecarried

forwardwithLayer2(802.1p)andLayer3(Diffserv)markings.SummitX250e

providesadvancedtrafficmanagementfeaturesthatsupportthe

high-qualitytripleplayofvoice,videoanddataservices.

Efficient Management to Handle Convergence-Driven Network Changes

Universal Port—VoIP Auto-Provisioning

SummitX250esetsthestageforconvergenceapplicationsbyallowing

enterprisestoaddnewaccessdevicesinanon-disruptiveplug-and-play

fashion.Voiceandwirelessservicescanbeeasilyimplementedwithout

majornetworkupgrades.SummitX250esupportstheautomated

provisioningofVoIPusingLinkLayerDiscoveryProtocol(LLDP)andthe

event-basedcommandscriptingcapability.Itallowsdynamicconfiguration

ofvoiceVLANsandQoS.Thisauto-configurationcapabilityallowsyouto

configureVoIPphonesettingssuchasvoiceVLANsettings,callserverIP

addressconfiguration,etc.(seeFigure3).Thislevelofsimplicityin

managingnetworkchangescanreduceoperatingexpenses.

Power over Ethernet (PoE)

DeploymentsofIPTelephonydependonreliable,consistentpowerfrom

theEthernetjack.SummitX250e-24pandSummitX250e-48parethe

basisforareliableLANtelephonyinfrastructurewithfullyredundant

resiliencytomatchthefailoverrequirementsforlatency-sensitiveservices

likeVoIPphones.WithSummitX250e-24por48p,deploymentofpowered

LANdevicesisquickandeasywithitssupportoftheIEEE802.3afstandard

andfullClass3poweravailabilityonallports,backedup100%bythe

EPS-500redundantpowersupply(SummitX250e-24p).SummitX250e-48p

canprovideupto370WofPoEpowerandcanbeincreasedupto740Wof

PoEpowertoprovidefull15.4WClass3devicesonall48portsbyadding

anExternalPowerSystem(EPS-CandEPS-600LS).

Voice-Grade Connections

GranularQoS,lowlatencyandlowjitterenablevoice-qualityconnections.

SummitX250esupportsarangeofQoStechnologiesthatcanprioritize

andpredictablyhandlehigh-prioritytrafficpolicingorratelimitingon

ingress,802.1QtaggingandDiffservmarking,andshapingonegresswith

eightqueuesperport.TheExtremeNetworkstraditionofbuildingproducts

withlowlatencyandjittercontinueswiththeSummitX250eseries.

Comprehensive Network Management

Asthenetworkbecomesafoundationoftheenterpriseapplication,

networkmanagementbecomesanimportantpieceofthesolution.

SummitX250esupportscomprehensivenetworkmanagementthrough

CommandLineInterface(CLI),SNMPv1,v2c,v3andanembedded

XML-basedWebUserInterface,ExtremeXOSScreenPlay™.Withavariety

ofmanagementoptionsandconsistencyacrossotherExtremeNetworks

modularandstackableswitches,SummitX250eseriesswitchescan

provideeaseofmanagementfordemandingconvergedapplications.

ExtremeNetworkshasdevelopedtoolsthatsimplifyandhelpinefficiently

managingyournetwork.Ridgeline™networkandservicemanagement

providesfault,configuration,accounting,performanceandsecurity

functions,allowingmoreeffectivemanagementofExtremeNetworks

products,solutionsandthird-partydevices,inaconvergednetwork.

Forcarriernetworks,Ridgelineenablestheshiftfromreactivecircuit

monitoringtoproactiveservicemanagement.Thekeyfeaturesintegrated

intotheServiceAdvisorFeaturePackunifyservicefulfillment,service

assuranceandserviceengineeringtoenablecarrierstomoreeffectively

managenext-generationresidentialtripleplay,businessEthernetand

Ethernetmobilebackhaulservices.

Advanced Routing Capabilities for the Edge

SummitX250esupportsadvancedprotocolsforanefficientandproductive

network.SummitX250eswitchesprovidestaticandRIProutingforsimple

IPv4andIPv6Layer3deployment.AnoptionalExtremeXOSAdvanced

Edgelicenseextendsthefeaturesettoincludeotherimportantedge

functionssuchas:

• EdgeOSPFformuchgreaterextensibilitythanRIPcanprovide

• EdgePIMsparsemodesforroutingofmulticaststreams

• Policy-basedrouting

• VirtualRouterRedundancyProtocol(VRRP)toproviderouting

redundancy

5044-03

1

1

2

3

4

5

3

5

2

4

Administrator defines Universal Port policy for IP phones.

Phone is connected.

Phone sends vendor, model, detailed power requirements, etc. to switch.

Switch automatically configures VLAN, QoS, and PoE on the port.

Switch pushes VLAN, QoS, call server details, etc. to the phone.

IP Phone

LLDP / LLDP-MED

Network Core

Figure 3: Universal Port Voice-over-IP Provisioning

4

Extreme Networks Data Sheet: Summit X250e Series Technical Specifications

Comprehensive Security Management

User Authentication and Host Integrity Checking

Network Login and Dynamic Security Profile

NetworkLogincapabilityenforcesuseradmissionandusagepolicies.

SummitX250eseriesswitchessupportacomprehensiverangeofNetwork

Loginoptionsbyprovidingan802.1xagent-basedapproach,aWeb-based

(agent-less)logincapabilityforguests,andaMAC-basedauthentication

modelfordevices.WiththesemodesofNetworkLogin,onlyauthorized

usersanddevicesarepermittedtoconnecttothenetworkandbeassigned

totheappropriateVLAN.TheUniversalPortscriptingframeworkletsyou

implementDynamicSecurityProfileswhichinsyncwithNetworkLogin

allowsyoutoimplementfine-grainedandrobustsecuritypolicies.Upon

authentication,theswitchcanloaddynamicACL/QoSprofilesforauseror

groupofusers,todeny/allowtheaccesstotheapplicationserversor

segmentswithinthenetwork.

Multiple Supplicant Support

Sharedportsrepresentapotentialvulnerabilityinanetwork.Multiple

supplicantcapabilityonaswitchallowsittouniquelyauthenticateand

applytheappropriatepoliciesandVLANsforeachuserordeviceona

sharedport.

MultiplesupplicantsupporthelpssecureIPTelephonyandwirelessaccess.

Convergednetworkdesignsofteninvolvetheuseofsharedports(see

Figure4).

Media Access Control (MAC) Lockdown

MACsecurityallowsthelockdownofaporttoagivenMACaddressand

limitingthenumberofMACaddressesonaport.Thiscanbeusedto

dedicateportstospecifichostsordevicessuchasVoIPphonesorprinters

andavoidabuseoftheport—acapabilitythatcanbeespeciallyusefulin

environmentssuchashotels.Inaddition,anagingtimercanbeconfigured

fortheMAClockdown,protectingthenetworkfromtheeffectsofattacks

using(oftenrapidly)changingMACaddresses.

IP Security

ExtremeXOSIPsecurityframeworkhelpsprotectthenetwork

infrastructure,networkservicessuchasDHCPandDNS,andhost

computersfromspoofingandman-in-the-middleattacks.Italsohelps

protectthenetworkfromstaticallyconfiguredand/orspoofedIPaddresses

andbuildsanexternaltrusteddatabaseofMAC/IP/portbindingsso

youknowwherethetrafficfromaspecificaddresscomesfromfor

immediatedefense.

Identity Manager

IdentityManagerallowsnetworkmanagerstotrackuserswhoaccesstheir

network.UseridentityiscapturedbasedonNetLoginauthentication,LLDP

discoveryandKerberossnooping.ExtremeXOSusestheinformationto

thenreportontheMAC,VLAN,computerhostname,andportlocationof

theuser.Further,IdentityManagercancreatebothrolesandpolicies,

andthenbindthemtogethertocreaterole-basedprofilesbasedon

organizationalstructureorotherlogicalgroupings,andapplythemacross

multipleuserstoallowappropriateaccesstonetworkresources.In

addition,supportforWideKeyACLsfurtherimprovessecuritybygoing

beyondthetypicalsource/destinationandMACaddressasidentification

criteriaaccessmechanismtoprovidefilteringcapabilities.

Host Integrity Checking

Hostintegritycheckinghelpskeepinfectedornoncompliantmachinesoff

thenetwork.SummitX250eseriesswitchessupportahostintegrityor

endpointintegritysolutionthatisbasedonthemodelfromtheTrusted

ComputingGroup.

Network Intrusion Detection and Response

CLEAR-Flow Security Rules Engine

CLEAR-FlowSecurityRulesEngineprovidesfirstorderthreatdetection

andmitigation,andmirrorstraffictoappliancesforfurtheranalysisof

suspicioustrafficinthenetwork.

Hardware-Based sFlow Sampling

sFlowisasamplingtechnologythatprovidestheabilitytocontinuously

monitorapplication-leveltrafficflowsonallinterfacessimultaneously.

ThesFlowagentisasoftwareprocessthatrunsonSummitX250eand

packagesdataintosFlowdatagramsthataresentoverthenetworktoan

sFlowcollector.Thecollectorgivesanup-to-the-minuteviewoftraffic

acrosstheentirenetwork,providingtheabilitytotroubleshootnetwork

problems,controlcongestionanddetectnetworksecuritythreats.

Port Mirroring

Forthreatdetectionandprevention,SummitX250esupportsmany-to-

oneandone-to-manyportmirroring.Thisallowsthemirroringoftrafficto

anexternalnetworkappliancesuchasanintrusiondetectiondevicefor

trendanalysisorforutilizationbyanetworkadministratorfordiagnostic

purposes.PortMirroringcanalsobeenabledacrossswitchesinastack.

Line-Rate ACLs

ACLsareoneofthemostpowerfulcomponentsusedincontrolling

networkresourceutilizationaswellasprotectingthenetwork.Summit

X250esupports1,024centralizedACLsper24-portblockbasedonLayer2,

3or4-headerinformationsuchastheMAC,IPv4andIPv6addressor

TCP/UDPport.ACLsareusedforfilteringthetraffic,aswellasclassifying

thetrafficflowtocontrolbandwidth,priority,mirroringandpolicy-based

routing/switching.

Denial of Service Protection

SummitX250ecaneffectivelyhandleDoSattacks.Iftheswitchdetectsan

unusuallylargenumberofpacketsintheCPUinputqueue,itwillassemble

ACLsthatautomaticallystopthesepacketsfromreachingtheCPU.Aftera

periodoftime,theseACLsareremoved,andreinstallediftheattack

continues.ASIC-basedLPMroutingeliminatestheneedforcontrolplane

softwaretolearnnewflows,allowingmorenetworkresilienceagainst

DoSattacks.

Secure Management

Topreventmanagementdatafrombeinginterceptedoralteredby

unauthorizedaccess,SummitX250esupportsSSH2,SCPandSNMPv3

protocols.TheMD5hashalgorithmusedinauthenticationprevents

attackersfromtamperingwithvaliddataduringroutingsessions.

5

Extreme Networks Data Sheet: Summit X250e Series Technical Specifications

5155-03

Summit® X250e o�ers multiple supplicant capability which helps provideper-MAC based authentication with dynamic VLAN allocation

VLAN Green VLAN Orange VLAN Purple Rogue Clients

` ` `` ``` ` `

Figure 4: Multiple Supplicant Support

Target Applications

Edge Connectivity for Advanced Enterprise Applications

EdgePoEandnon-PoEswitchesprovideintelligent10/100BASE-T

connectivitytothedesktopinanetworkrunningExtremeXOSfrom

theedgetothecore.

SummitX250eisdeployedasintelligentFastEthernetedgeswitch,

extendingthebenefitsoftheExtremeXOSoperatingsystemtothe

networkedgeintheenterprisenetwork.Thisuniformityallows

consistentqualityandperformancethroughoutyourconverged

networkwhileminimizingoperationalinefficiencies.Withline-rate

performanceandlowlatency,theSummitX250eedgeswitch

connectswirelessdevices,LANtelephony,PDAsandother

equipmentwithoutcompromisingsecurity,scalability,availability,

mobilityormanagement.

Edge Connectivity for Advanced Carrier Ethernet Applications

CarrierEthernetedgeswitchingwith100BASE-Xprovides

advancedfiberconnectivitytothecustomer.

SummitX250eisdeployedasanintelligentFastEthernetedgeswitch,

extendingthebenefitsoftheExtremeXOSoperatingsystemtothe

networkedgeintheCarrierEthernetnetwork.Thisuniformityallows

consistentqualityandperformancethroughoutaconvergednetwork

whileminimizingoperationalinefficiencies.Withline-rateperformance

andlowlatency,theSummitX250eedgeswitchprovidescopper

10/100BASE-Tconnectivityaswellas100BASE-Xconnectivity

including100BASE-FX,100BASE-LX10and100BASE-BX.Aflexible

connectivityoptionisofferedwithoutcompromisingsecurity,

scalability,availability,mobilityormanagement.SummitX250ehas

bothACandDCpoweredmodelsforflexibledeployments.

5045-03

Summit® X250e Summit X250e

`

1-@ 2ABCDEF3

4GHI 5ABCMNO6

7PQRS 8TUV

0+| #+|

*UWXYZ9

`

1-@ 2ABCDEF3

4GHI 5ABCMNO6

7PQRS 8TUV

0+| #+|

*UWXYZ9

Network Core

5190-02

Service Router

Single Family Homes Central O�ce Point of Presence

BlackDiamond® 8810 with8900-xl Series ModulesSummit® X250e

6

Extreme Networks Data Sheet: Summit X250e Series Technical Specifications

EPS-500

EPS-500istheredundantACPowerSupplyforhigherpowerconsumingAC

PSU-basedswitchesincludingPoE-enabledswitches.EPS-500isonerack

unitheightandworksinstandalonemode.EPS-500canberack-mountedin

aregular19inchracksystem.EPS-500comeswithaDCoutputcableto

connectbetweentheSummitswitchandEPS-500.

EPS-600LS and EPS-C

EPS-600LSisapowermodulethatworkswiththeEPS-CExternalPower

SystemChassis.EPS-ChasthreeslotsforEPS-600LSandoneDCoutputto

connecttohigh-densityPoESummitswitches.Dependinguponthenumber

ofEPS-600LSinstalledinEPS-C,itcanprovide:1)Redundantconfiguration

forupto370wattsofPoEpowerwithoneEPS-600LSinstalled;2)Non-

redundantconfigurationforupto740wattsofPoEpowerwhentwo

EPS-600LSareinstalled;and3)Redundantconfigurationforupto740watts

ofPoEpowerwhenthreeEPS-600LSareinstalled.EPS-CcomeswithaDC

outputcabletoconnectbetweentheSummitswitchandEPS-Cwith

EPS-600LSinstalled.

EPS-150DC and EPS-T2

EPS-150DCistheredundantDCPowerSupplyforDCPSU-basedSummit

switches.TheEPS-T2powertrayisrequiredtorack-mountthisexternal

powersupply.EPS-T2powertraycantakeuptotwoEPS-150DCpower

modules,andeachEPS-150DCworksindividually.EPS-150DCcomeswitha

DCoutputcabletoconnectbetweentheSummitswitchandEPS-150DC.

Front View

Front View

Front View

Front View

Rear View

Configured View

Rear View

Rear View

Accessories

Summit X250e Series Redundant PSUs

EPS-160 and EPS-T

EPS-160istheredundantACPowerSupplyforlowerpowerconsumingAC

PSU-basedSummitswitches.TheEPS-Tpowertrayisrequiredtorack-mount

thisexternalpowersupply.EPS-TpowertraycantakeuptotwoEPS-160

powermodules,andeachEPS-160worksindividually.EPS-160comeswitha

DCoutputcabletoconnectbetweentheSummitswitchandEPS-160.

Redundant PSU Compatibility Matrix

Summit Switch ModelsSummit Switch Part Number(s) External Redundant PSU options

SummitX250e-24t/48t/24x 15101/15103/15109 EPS-160powermodule(10907)withEPS-T(10906)

SummitX250e-24p 15105 EPS-500externalpowersupply(10911)

SummitX250e-48p/48p-TAA 15107/15108 EPS-C(10912)andEPS-600LS(10913)

SummitX250e-24tDC/48tDC/24xDC 15121/15122/15123 EPS-150DCpowermodule(10909)withEPS-T2(10910)

Technical Specifications

7

Extreme Networks Data Sheet: Summit X250e Series

General Specifications

Performance

48.8Gbpsswitchfabricbandwidth

36.3Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesperswitch

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Summit X250e-24t

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

24ports10/100BASE-Twithauto-speedandauto-polarity

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portSerial(controlport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-160withEPS-T

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:12.13Inches/30.8Cm

Weight:10.47Lbs/4.76Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50/60Hz,1.0A

InputCurrent:0.5A@115V~(lowline)0.25A@230V~(high-line)

MaximumIn-RushCurrent:30A@115V,60A@230V

Efficiency:83%with60%–100%load

LineFrequencyRange:47–63Hz

PowerSupplyInputSocket:IEC320C14

Summit X250e-48t

General Specifications

Performance

97.6Gbpsswitchfabricbandwidth

39.9Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesper24-port

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

48ports10/100BASE-Twithauto-speedandauto-polarity

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portserial(consoleport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-160withEPS-T

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:15.28Inches/38.8Cm

Weight:12.06lbs/5.48Kg

Supported Protocols and StandardsAlistofsupportedprotocolsandstandardsisavailableontheExtremeNetworkswebsiteat:http://www.extremenetworks.com/go/xos

Technical Specifications

Operating Specifications ( continued )

PowerCordInputPlug:IEC320C13

HeatDissipation:36W(123BTU/h)

PowerConsumption:36W(123BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):45dBAperISO7779

Technical Specifications

8

Extreme Networks Data Sheet: Summit X250e Series

General Specifications

Performance

48.8Gbpsswitchfabricbandwidth

36.3Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesperswitch

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Summit X250e-24x

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

24ports100BASE-Xsupporting100BASE-XSFPOpticalTransceivers

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portSerial(controlport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-160andEPS-T

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:12.13Inches/30.8Cm

Weight:10.21Lbs/4.64Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50/60Hz,1.0A

InputCurrent:1.0A@115V~(lowline)0.5A@230V~(high-line)

MaximumIn-RushCurrent:30A@115V,60A@230V

Efficiency:83%with60%–100%load

LineFrequencyRange:47–63Hz

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

HeatDissipation:49W(167.2BTU/h)

PowerConsumption:49W(167.2BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):45dBAperISO7779

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

24ports10/100BASE-TPoEwithauto-speedandauto-polarity

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portserial(consoleport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-500

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:12.13Inches/30.8Cm

Weight:12.1Lbs/5.46Kg

Summit X250e-24p

General Specifications

Performance

48.8Gbpsswitchfabricbandwidth

36.3Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesperswitch

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Operating Specifications ( continued )

Power & Acoustic Sound

VoltageInputRange:90–264V

NominalInputRatings:100-240V~,50/60Hz,1.0A

InputCurrent:0.6A@115V~(lowline)0.3A@230V~(high-line)

MaximumIn-RushCurrent:30A@115V,60A@230V

Efficiency:83%with60%–100%load

LineFrequencyRange:47–63Hz

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

HeatDissipation:51W(174BTU/h)

PowerConsumption:51W(174BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):47dBAperISO7779

Technical Specifications

9

Extreme Networks Data Sheet: Summit X250e Series

General Specifications

Performance

97.6Gbpsswitchfabricbandwidth

39.9Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesper24-port

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Summit X250e-48p

HeatDissipation(withPoEfullload):100W(341BTU/h)

PowerConsumption(withPoEfullload):470W(1604BTU/h)

HeatDissipation(withoutPoE):55W(188BTU/h)

PowerConsumption(withoutPoE):55W(188BTU/h)

AcousticNoise(LowFANSpeed):39dBAperISO7779

AcousticNoise(HighFANSpeed):44dBAperISO7779

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

48ports10/100BASE-TPoEwithauto-speedandauto-polarity

2portsGigabitEthernet(SFPsharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portserial(consoleport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-CwithEPS-600LS

ExternalPowerSupply–EPS-CChassisacceptsuptothreeEPS-600LSpowermodulesandprovidesthefollowingcapabilitydependinguponthenumberofEPS600LSinstalled• OneEPS-600LS

– Redundant,upto370WPoEpower• TwoEPS-600LS

– Redundant,upto370WPoEpower– Non-Redundant,upto740WPoEpower

• ThreeEPS-600LS

Redundant,upto740WPoEpower

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:15.28Inches/38.8Cm

Weight:12.06lbs/5.48Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50/60Hz,5.5A

InputCurrent(withPoEfullload):4.5A@115V~(lowline)2.25A@230V~(highline)

InputCurrent(withoutPoE):0.75A@115V~(lowline)0.5A@230V~(highline)

MaximumIn-RushCurrent:30A@115V,60A@230V

Efficiency:78%with60%–100%load

LineFrequencyRange:47–63Hz

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

HeatDissipation(withPoEfullload):130W(444BTU/h)

PowerConsumption(withPoEfullload):525W(1,791BTU/h)

HeatDissipation(withoutPoE):75W(256BTU/h)

PowerConsumption(withoutPoE):75W(256BTU/h)

AcousticNoise(LowFANSpeed):39dBAperISO7779

AcousticNoise(HighFANSpeed):46dBAperISO7779

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50/60Hz,5.5A

InputCurrent(withPoEfullload):4.4A@115V~(lowline)2.2A@230V~(high-line)

InputCurrent(withoutPoE):0.75A@115V~(lowline)0.5A@230V~(high-line)

MaximumIn-RushCurrent:30A@115V,60A@230V

Efficiency:81%with60%–100%load

LineFrequencyRange:47–63Hz

NominalFrequencyRange:50–60Hz

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

General Specifications ( continued )

Technical Specifications

10

Extreme Networks Data Sheet: Summit X250e Series

General Specifications

Performance

48.8Gbpsswitchfabricbandwidth

36.3Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesperswitch

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

24ports10/100BASE-Twithauto-speedandauto-polarity

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portSerial(controlport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-150DCwithEPS-T2

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:12.13Inches/30.8Cm

Weight:9.88Lbs/4.49Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:-40to-72VDC

InputCurrentRating:2.0Aat-48VDC

InputCurrent:0.8A@-40VDC,0.5A@-72VDC

MaximumIn-RushCurrent:20A@-48VDC,30A@-72VDC

Efficiency:78%

PowerSupplyInputSocket:TYCO206061-1

PowerCordInputPlug:TYCO206060-1

HeatDissipation:31W(105.8BTU/h)

PowerConsumption:31W(105.8BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):45dBAperISO7779

Summit X250e-24tDC

General Specifications

Performance

97.6Gbpsswitchfabricbandwidth

39.9Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesper24-port

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

48ports10/100BASE-Twithauto-speedandauto-polarity

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portserial(consoleport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-150DCwithEPS-T2

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:15.28Inches/38.8Cm

Weight:12.14Lbs/5.52Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:-40to-72VDC

InputCurrentRating:2.0Aat-48VDC

InputCurrent:1.25A@-40VDC,0.75A@-72VDC

MaximumIn-RushCurrent:20A@-48VDC,30A@-72VDC

Efficiency:78%

PowerSupplyInputSocket:TYCO206061-1

PowerCordInputPlug:TYCO206060-1

HeatDissipation:47W(160.4BTU/h)

PowerConsumption:47W(160.4BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):47dBAperISO7779

Summit X250e-48tDC

Technical Specifications

11

Extreme Networks Data Sheet: Summit X250e Series

General Specifications

Performance

48.8Gbpsswitchfabricbandwidth

36.3Mppsframeforwardingrate

9,216Bytemaximumpacketsize(JumboFrame)

128loadsharingtrunks,upto8memberspertrunk

8QoSqueues/port

4,094VLANs(Port,Protocol,IEEE802.1Q)

1,024centralizedACLrulesperswitch

Forwarding Tables

Layer2/MACAddresses:8K

IPv4LPMEntries:512

IPv6LPMEntries:256

Rate Limiting

Ingressbandwidthpolicing/ratelimitingperflow

Egressbandwidthrateshapingperegressqueueandperport

RateLimitingGranularity:64Kbps

AvailableRateLimiters:1,024perswitch

Indicators

PerportstatusLED

SystemStatusLEDs:management,fanandpower

Ports

24ports100BASE-Xsupporting100BASE-XSFPOpticalTransceivers

2portsGigabitEthernet(100/1000BASE-XSFP,sharedPHYwith210/100/1000BASE-Tports)

2SummitStackstackinginterfaces

1portSerial(controlport)

110/100BASE-Tout-of-bandmanagementport

External Power Supply Support

EPS-150DCwithEPS-T2

Physical Specifications

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.35Inches/44.1Cm

Depth:12.13Inches/30.8Cm

Weight:9.97Lbs/4.53Kg

Operating Specifications

Power & Acoustic Sound

VoltageInputRange:-40to-72VDC

InputCurrentRating:2.0Aat-48VDC

InputCurrent:1.25A@-40VDC,0.75A@-72VDC

MaximumIn-RushCurrent:20A@-48VDC,30A@-72VDC

Efficiency:83%

PowerSupplyInputSocket:TYCO206061-1

PowerCordInputPlug:TYCO206060-1

HeatDissipation:42W(143.3BTU/h)

PowerConsumption:47W(160.4BTU/h)

AcousticNoise(LowFANSpeed):37dBAperISO7779

AcousticNoise(HighFANSpeed):47dBAperISO7779

Summit X250e-24xDC

Regulatory/Safety Standards

North American Safety of ITE

UL60950-11stEd.,ListedDevice(U.S.)

CSA22.2#60950-1-031stEd.(Canada)

ComplieswithFCC21CFR1040.10(U.S.LaserSafety)

CDRHLetterofApproval(U.S.FDAApproval)

European Safety of ITE

EN60950-1:2001+A11

EN60825-1+A2:2001(LasersSafety)

TUV-RGSMarkbyGermanNotifiedBody

2006/95/ECLowVoltageDirective

International Safety of ITE

CBReport&CertificateperIEC60950-1:2001+NationalDifferences

AS/NZS60950-1(Australia/NewZealand)

EMI/EMC Standards

North America EMC for ITE

FCCCFR47part15ClassA(U.S.)

ICES-003ClassA(Canada)

European EMC Standards

EN55022:2003ClassA

EN55024:A2-2003ClassAincludesIEC61000-4-2,3,4,5,6,11

EN61000-3-2,2006(Harmonics)

EN61000-3-31995+A1:2001(Flicker)

ETSIEN300386v1.3.3,2005-04(EMCTelecommunications)

2004/108/ECEMCDirective

International EMC Certifications

CISPR22:2005,ClassA(InternationalEmissions)

CISPR24:A2:2003ClassA(InternationalImmunity)

IEC/EN61000-4-2:2001ElectrostaticDischarge,8kVContact,15kVAir,CriteriaA

EC/EN61000-4-3:2002RadiatedImmunity10V/m,CriteriaA

EC/EN61000-4-4:2004TransientBurst,1kV,CriteriaA

IEC/EN61000-4-5:2001Surge,2kVL-L,2kVL-G,Level3,CriteriaA

IEC/EN61000-4-6:2004ConductedImmunity,0.15-80MHz,10V/munmod.RMS,CriteriaA

EC/EN61000-4-11:2004PowerDips&Interruptions,>30%,25periods,CriteriaC

Country Specific

VCCIClassA(JapanEmissions)

ACMA(C-Tick)(AustraliaEmissions)

KCCMarkEMCApproval(Korea)

Telecom Standards

EN/ETSI300386:2001(EMCTelecommunications)

EN/ETSI300019(EnvironmentalforTelecommunications)

MEF9andMEF14certifiedforEPL,EVPLandELAN

NEBSLevel3complianttoportionsofGR-1089Issue4&GR-63Issue3asdefinedinSR3580withexceptiontofilterrequirement

IEEE 802.3 Media Access Standards

IEEE802.310BASE-T

IEEE802.3u100BASE-TX

IEEE802.3ab1000BASE-T

IEEE802.3z1000BASE-X

Summit X250e Series

Technical Specifications

12

Extreme Networks Data Sheet: Summit X250e Series

Environmental Standards

EN/ETSI300019-2-1v2.1.2(2000-09)-Class1.2Storage

EN/ETSI300019-2-2v2.1.2(1999-09)-Class2.3Transportation

EN/ETSI300019-2-3v2.1.2(2003-04)-Class3.1eOperational

EN/ETSI300753(1997-10)–AcousticNoise

ASTMD3580RandomVibrationUnpackaged1.5G

Operating Specifications

Temperature

OperatingTemperatureRange:0°Cto40°C(32°Fto104°F)

OperatingHumidity:10%to93%relativehumidity,non-condensing

OperationalShock(HalfSine):30m/s2(3g),11ms,60Shocks

OperationalRandomVibration:5–[email protected]

Storage & Transportation Conditions (Packaged)

TransportationTemperature:-40°Cto70°C(-40°Fto158°F)

StorageandTransportationHumidity:10%to95%RH,non-condensing

PackagedShock(HalfSine):180m/s2(18g),6ms,600shocks

PackagedSineVibration:5–62Hz@Velocity5mm/s,62–[email protected]

PackagedRandomVibration:5–[email protected]/-3dB/oct.from20–200Hz

14dropsminonsides&corners@42”(<15kgbox)

Security

CommonCriteriaEAL3+

Warranty

Ltd.LifetimewithexpressAdvancedHardwareReplacement(forproductsshippedfromExtremeNetworksonorafterJune29,2009)

Forwarrantydetails,visitwww.extremenetworks.com/go/warranty

Technical Specifications

13

Extreme Networks Data Sheet: Summit X250e Series

Power Supply Units EPS-160/EPS-T

EPS-500

EPS-C/EPS-600LS

EPS-150DC/EPS-T2

Dimensions and Weight

EPS-160

Height:1.69Inches/4.3Cm

Width:7.68Inches/19.5Cm

Depth:7.32Inches/18.6Cm

Weight:2.90Lbs/1.32Kg

EPS-T

Height:1.73Inches/4.4Cm

Width:17.32Inches/44.0Cm

Depth:7.64Inches/19.4Cm

Weight:3.74Lbs/1.70Kg

Power

EPS-160

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50–60Hz,10A

LineFrequencyRange:47–63Hz

MaximumInputCurrent:2Aat115VAC,1Aat230VAC

MaximumInrushCurrent:30Aat115VAC,60Aat230VAC

PowerSupplyInputSocket:IEC320C144

PowerCordInputPlug:IEC320C13

HeatDissipation:38.5W(131.4BTU/h)

PowerConsumption:178W(607.4BTU/h)

Dimensions and Weight

Height:1.73Inches/4.4Cm

Width:17.4Inches/44Cm

Depth:7.6Inches/19.3Cm

Weight:10.8Lbs/4.9Kg

Power

VoltageInputRange:90–264V

NominalInputRatings:100–240V~,50–60Hz,10A

LineFrequencyRange:47–63Hz

MaximumInputCurrent:5.75Aat115VAC,2.80Aat230VAC

MaximumInrushCurrent:30Aat115VAC,60Aat230VAC

Output:-50VDC,7.5Amax,375Watts12VDC,7.5Amax,90Watts

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

HeatDissipation:158W(539.1BTU/h)

PowerConsumption:659W(2448.6BTU/h)

Dimensions and Weight

EPS-C

Height:1.73Inches/4.4Cm

Width:17.32Inches/44.0Cm

Depth:11.81Inches/30.0Cm

Weight:7.17Lbs/3.16Kg

EPS-600LS

Height:1.69Inches/4.3Cm

Width:4.61Inches/11.7Cm

Depth:11.81Inches/30.9Cm

Weight:3.74Lbs/1.70Kg

Power

EPS-600LS

VoltageInputRange:90–264V

NominalInputVoltage/Hz:115V~/60Hz&230V~/50Hz,10.0A

LineFrequencyRange:47–63Hz

MaximumInputCurrentRating:7.0Aat115VAC,3.5Aat230VAC

MaximumInrushCurrent:30Aat115VAC,60Aat230VAC

PowerSupplyInputSocket:IEC320C14

PowerCordInputPlug:IEC320C13

HeatDissipation:219W(747.7BTU/h)

PowerConsumption:801W(2733.1BTU/h)

External Power Supply Chassis System – EPS-C with three EPS-600LS installed

HeatDissipation:360W(1228.4BTU/h)

PowerConsumption:1620W(5,527.7BTU/h)

Dimensions and Weight

EPS-150DC

Height:1.65Inches/4.2cm

Width:3.74Inches/9.5cm

Depth:10.12Inches/25.7cm

Weight:3.76Lbs/1.71Kg

EPS-T2

Height:1.77Inches/4.5cm

Width:17.32Inches/44.0cm

Depth:8.66Inches/22.0cm

Weight:4.0Lbs/1.82Kg

Power

EPS-600LS

VoltageInputRange:-36to-72VDC,6.0A

InputCurrentRating:5.5A@-36VDC,2.6A@-72VDC

MaximumInrushCurrent:20A@-48VDC,40A@-72VDC

Efficiency:75%with100%loadat25°C

PowerSupplyInputSocket:TYCO206061-1

PowerCordInputPlug:TYCO206060-1

HeatDissipation:45W(153.5BTU/h)

PowerConsumption:195W(665.4BTU/h)

Technical Specifications

14

Extreme Networks Data Sheet: Summit X250e Series

Ordering Information

Part Number Name Description

15101 SummitX250e-24t 2410/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15101T SummitX250e-24t-TAA U.S.FederalTAA,2410/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15103 SummitX250e-48t 4810/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15103T SummitX250e-48t-TAA U.S.FederalTAA,4810/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15105 SummitX250e-24p 2410/100BASE-TXwithPoE,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-500externalredundantPSU

15105T SummitX250e-24p-TAA U.S.FederalTAA,2410/100BASE-TXwithPoE,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-500externalredundantPSU

15107 SummitX250e-48p 4810/100BASE-TXwithPoE,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-Cexternalredundantpowersystemchassis(requiresEPS-600LS)

15107T SummitX250e-48p-TAA U.S.FederalTAA,4810/100BASE-TXwithPoE,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgelicense,1ACPSU,connectorforEPS-Cexternalredundantpowersystemchassis(requiresEPS-600LS)

15109 SummitX250e-24x 24100BASE-XSFP,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15109T SummitX250e-24x-TAA U.S.FederalTAA,24100BASE-XSFP,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgeLicense,1ACPSU,connectorforEPS-160externalredundantPSU

15121 SummitX250e-24tDC 2410/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgelicense,1DCPSU,connectorforEPS-150DCexternalredundantPSU

15122 SummitX250e-48tDC 4810/100BASE-TX,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgelicense,1DCPSU,connectorforEPS-150DCexternalredundantPSU

15123 SummitX250e-24xDC 24100BASE-TSFPports,2gigabitcomboports(2unpopulatedgigabitSFPand10/100/1000BASE-T),2SummitStackstackingports,ExtremeXOSEdgelicense,1DCPSU,connectorforEPS-150DCexternalredundantPSU

15113 SummitX250eseriesAdvancedEdgeLicense

ExtremeXOSAdvancedEdgeLicense,SummitX250eseries

10906 EPS-T1 ExternalPowerSystempowertray.AcceptsuptotwoEPS-160powermodules

10907 EPS-1601 ExternalPowerSystempowermoduleforEPS-T,160Watts,Powercordorderedseparately

10911 EPS-500ExternalACPSU2 ExternalPowerSystem500Watts,Powercordorderedseparately

1 Compatible with Summit X250e-24t and Summit X250e-48t2 Compatible with Summit X250e-24p

Extreme Networks Data Sheet: Summit X250e Series

Make Your Network Mobile

© 2012 Extreme Networks, Inc. All rights reserved. Extreme Networks, the Extreme Networks logo, Extreme Standby Router Protocol, ExtremeXOS, ExtremeXOS, Ridgeline, Screen-play, Sentriant, Summit, SummitStack and UniStack are either registered trademarks or trademarks of Extreme Networks, Inc. in the United States and/or other countries. sFlow is the property of InMon Corporation. Specifications are subject to change without notice. 1341_20 04/12

extremenetworks.com

Corporateand North AmericaExtreme Networks, Inc.3585 Monroe Street Santa Clara, CA 95051 USAPhone +1 408 579 2800

Europe, Middle East, Africaand South AmericaPhone +31 30 800 5100

Asia PacificPhone +65 6836 5437

JapanPhone +81 3 5842 4011

Technical Specifications

Part Number Name Description

10912 EPS-C3 ExternalPowerSupplyUnit.Powercordorderedseparately.AcceptsuptothreeEPS-600LSpowermodules

10913 EPS-600LS3 ExternalPowerSystemPowerModuleforEPS-C,600Watts

10909 EPS-150DC4 ExternalPowerSystempowermoduleforEPS-T,150Watts,withcable,DCInput

10910 EPS-T24 ExternalPowerSystempowertray.AcceptsuptotwoEPS-150DCpowermodules.AddoneEPS-150DCforeachredundantlypoweredsystem

10051 SXSFP 1000BASE-SSFP,1000BASE-SX,LCConnector

10052 LXSFP ExternalPowerSystem500Watts,Powercordorderedseparately

10053 ZXSFP 1000BASE-ZXSFP,ExtraLongDistanceSMF70km/21dBBudget,LCConnector

10064 LX100SFP 1000BASE-LX100SFP,ExtraLongDistanceSMF100km/30dBBudget,LCConnector

10056 1000BXSFPBX-D 1000BASE-BX-DSFP,SMF(1490nmTX/1310nmRXWavelength),LCConnector

10057 1000BXSFPBX-U 1000BASE-BX-USFP,SMF(1310-nmTX/1490-nmRXWavelength),LCConnector

10058 100BASE-BXSFPBX-D 100MSFP,100BASE-BX-D,SMF(1550-nmTX/1310-nmRXwavelength),100Mbpsbidirectional

10059 100BASE-BXSFPBX-U 100MSFP,100BASE-BX-U,SMF(1310-nmTX/1550-nmRXwavelength),100Mbpsbidirectional

10066 100BASE-LX10SFP 100MSFP,100LX10SMF,(1310-nm10kmsinglemodetransmission)LCconnector

10067 100BASE-FXSFP 100MSFP,100FXMMF,(1310-nm,2kmmultimodetransmission)LCconnector

16106 StackingCable,0.5M SummitStack/UniStack™stackingcable,0.5M

16107 StackingCable,1.5M SummitStack/UniStackstackingcable,1.5M

16108 StackingCable,3.0M SummitStack/UniStackstackingcable,3.0M

16105 StackingCable,5.0M SummitStackStackingCable,5.0M(notsupportedforUniStack)

3 Compatible with Summit X250e-48p4 Compatible with Summit X250e-24tDC, Summit X250e-48tDC and Summit X250e-24xDC