sun fire x2250 technical training presentation

32
Sun Fire X2250 Technical Training v1.4 Token # 535321 Ron Graham Systems Technical Marketing Sun Microsystems

Upload: xkinanx

Post on 01-Nov-2014

1.071 views

Category:

Technology


6 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Sun fire x2250 technical training presentation

Sun Fire X2250 Technical Training v1.4

Token # 535321

Ron GrahamSystems Technical MarketingSun Microsystems

Page 2: Sun fire x2250 technical training presentation

Page: 2 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Agenda

• Introduction

• Architectural overview

• Hardware

• Software

• Remote management

Page 3: Sun fire x2250 technical training presentation

Page: 3 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250Entry x64 Intel RackmountEntry x64 Intel Rackmount

1U 2-Socket1U 2-Socket

Ideal for HPC and Web 2.0 applications

Compute● Two Intel Xeon processors (5200 series

dual-core or 5400 series quad-core)● Eight FB-DIMM slots (DDR2-667/800,

32GB max)

I/O● One PCIe x16 slot● Two 3.5-inch 7,200 RPM SATA HDD● Two Gigabit Ethernet ports● Tray load slim DVD● Five USB 2.0 ports

Hardware RAS● Remote management with ILOM 2.0● RAID 0, 1● Trusted Platform Module (TPM)● DIMM Mirroring and Sparing

Software● Solaris, Linux, and Windows

Page 4: Sun fire x2250 technical training presentation

Page: 4 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2200 M2 vs X2250

Feature Sun Fire X2200 M2 Sun Fire X2250

Form Factor 1RU 1RU

Processor

I/O Chipset nVidia nForce Professional 3600 Intel 5400 Chipset

CPU to I/O Interconnect HyperTransport 2.0 Front Side Bus

Memory Type ECC registered DDR2-667 FB DIMM DDR2-667/800

Memory Capacity

Storage Up to 2 SATA HDD

Optical Drive DVD-ROM or DVD-RW DVD-ROM or DVD-RW

Service Processor Aspeed AST2000 Aspeed AST2000

Remote Management Embedded LOM ILOM 2.0

Network Management Shared 10/100 with Broadcom port Dedicated 10/100 port through AST2000

PCI Express 1 x16 PCIe (1.0)

Ethernet 2 nVidia GigE, 2 Broadcom GigE 2 Intel GigE

USB 2.0

Serial Ports 1 serial DB-9 male port 1 TIA/EIA-232-F asynchronous RJ45 port

Power Supply 450 Watt 500 Watt

Operating System Solaris, RedHat, SuSE, & Windows

2 AMD Opteron 2000 series(dual- or quad-core)

2 Intel Xeon 5000 sequence(dual- or quad-core)

16 DIMM slots, 64GB max(512MB, 1GB, 2GB, & 4GB)

8 DIMM slots, 32GB max(1GB, 2GB, & 4GB)

Up to 2 SATA or SAS HDD

2 x8 PCIe or 1 x16 PCIe (1.0)

6 (2 front, 4 rear) 5 (2 front, 2 rear, 1 internal)

Solaris, RedHat, SuSE, Windows,& Vmware

Page 5: Sun fire x2250 technical training presentation

Page: 5 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 Competitive Landscape

Sun Fire X2250

Rack Space 1U 1U 1U 1U 1U

CPU Type Intel Xeon 5000 Intel Xeon 5000 AMD Opteron 2200 Intel Xeon 5000 Intel Xeon 5000

Chipset Intel 5400 Intel 5400 Intel 5000X Intel 5000X

DIMMs / Chassis 8 FBDIMM 8 FBDIMM 8 RDDR2 8 FBDIMM 8 FBDIMM

Max Memory 32GB 32GB 32GB 32GB 32GB

Memory FB DDR2-667 RDDR2-667 FB DDR2-667 FB DDR2-667

HDD 2x 3.5” SATA 4x 3.5” SATA/SAS 4x 2.5” SAS

GbE Ports 2x GbE 2x GbE 2x GbE 2x GbE 2x GbE

Expansion Slots 1x PCIe x16 2x PCIe x16 (2.0) 1x PCIe x8 or PCI-X2x PCIe x8 or PCI-X 2x PCIe or PCI-X

I/O ports USB, Serial USB, Serial USB, Serial USB, Serial

PSU 500W 650W 600W 2x670W 2x670W

Management ILOM 2.0 LO 100i IPMI 2.0 IPMI 2.0 IPMI 2.0

Competitors → Features ↓

HPDL160 G5

DellPE SC1435

DellPE1950

IBMX3550

Broadcom HT-2100and HT-1000

FB DDR2-667/800

2x 3.5” SATA/SAS 2x 3.5” SATA/SAS 4x 2.5” SAS

USB, Serial,PS/2

Page 6: Sun fire x2250 technical training presentation

Page: 6 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Agenda

• Introduction

• Architectural overview

• Hardware

• Software

• Remote management

Page 7: Sun fire x2250 technical training presentation

Page: 7 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 Architecture Overview

X2250 is based on Intel Stoakley Platform

• Intel Xeon 5000 sequence processors> Intel Quad Core Xeon 5400 series processor (Harpertown)> Intel Dual Core Xeon 5200 series processor (Wolfdale-DP)

• Intel 5400 Chipset> Intel 5400 Chipset Memory Controller Hub (MCH) (Seaburg)> Intel 632xESB I/O Controller Hub (IOCH)

For more details on Intel Platforms, see SunWIN document #520953 “Intel Codenames Explained”

Page 8: Sun fire x2250 technical training presentation

Page: 8 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

PC

Ie x

16

Sun Fire X2250 – Block Diagram

ESI (PCIe)

PC

Ie x

16 -

1

SA

TA

PC

I 32-

bit 3

3 M

Hz

VGAVideo

Management10/100Ethernet

SerialRJ-45

GBEthernet0 & 1

USB

2x RearUSB 2.0

2x FrontUSB 2.0

1x InternalUSB 2.0

PCIe

MCHMCHIntel 5400Intel 5400

2x SATAHDDs

Ch

ann

el B

Ch

ann

el A

Ch

an

ne

l C

Ch

an

ne

l D

DIMM B0

DIMM B1

DIMM A0

DIMM A1

DIMM C1

DIMM C0

DIMM D1

DIMM D0

Intel Xeon5200/5400

Intel Xeon5200/5400

CD/DVDIDE

IOHIOHESB-2ESB-2

Dual FSB to MCH

1333/1600 MT/s

10.5 GB/s

10.5 GB/s

5.3

GB

/s

5.3

GB

/s

5.3

GB

/s

5.3

GB

/s

USB

Page 9: Sun fire x2250 technical training presentation

Page: 9 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Intel Xeon 5200/5400 Series

45nm Hi-k (penryn) next generation Intel Core microarchitecture

• Intel Xeon 5400 series (Harpertown)> 2x 6MB L2 cache, quad-core> 2.0GHz – 3.2GHz clock speeds> 1333 and 1600 MT/s FSB

• Intel Xeon 5200 series (Wolfdale)> 6MB L2 cache, dual-core> 1.86GHz – 3.4GHz clock speeds> 1066, 1333, and 1600 MT/s FSB

• Single or dual processor configurations

Page 10: Sun fire x2250 technical training presentation

Page: 10 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Intel 5400 Chipset MCH (Seaburg)

• Two independent Front Side Bus (FSB) connections> FSB speed of 1066/1333/1600 MT/s> Integrated 24MB snoop filter> Quad pumped

• Four channels of Fully Buffered DIMM (FBD) memory with 8 DIMMs/channel> FBD DDR2-533/667/800, up to 128GB> Memory sparing support (post RR)> No memory mirroring support

• Nine x4 PCIe 2.0 ports, supporting configurations of x8 and x16 slots> PCIe 1.0 support only

• Intel 631x/632x IOCH connectivity

Page 11: Sun fire x2250 technical training presentation

Page: 11 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Intel 632x ESB IOCH

• Dual-gigabit MAC> Compliant with 1000 Mb/sec

Ethernet/802.3z spec> Multi-speed operation: 10/100/1000Mb/s

• Integrated Serial ATA controller> Six ports, data transfer rates up to 3.0 Gbs

(300 MB/s)

• Integrated IDE controller> Ultra ATA/100/66/33

• USB 2.0

• PCI v2.3 Bus Interface> PCI v1.0 support only

SA

TA

PC

I 32-

bit 3

3 M

Hz

VGAVideo

Management10/100Ethernet

SerialRJ-45

GBEthernet0 & 1

USB

2x RearUSB 2.0

2x FrontUSB 2.0

1x InternalUSB 2.0

2x SATAHDDs

CD/DVDIDE

IOHIOHESB-2ESB-2

USB

Page 12: Sun fire x2250 technical training presentation

Page: 12 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Snoop Filter Overview

> Snoop Filter helps lower FSB utilization and improves FSB headroom> Snoop Filter (SF) is a cache-tag structure stored in the chipset

– Keeps track of the status of cache lines in the processor caches– Contains only TAGs and status of cache lines and NOT the data– Filters all unnecessary snoops to the remote bus

Intel® 5400chipset

24MB Snoop Filter Cache

CORE1

CORE2

6MB Cache

CORE3

CORE4

6MB Cache

CORE1

CORE2

6MB Cache

CORE3

CORE4

6MB Cache

> Snoop Filter decreases the FSB utilizations– Forwards only requests that need to be snooped on

the remote bus– Cache line that could potentially be present in a

dirty state on the remote bus – Cache lines that need to be invalidated

– Filters all the other processor snoops & large fraction of IO-snoops

– All I/O-bound applications benefit automatically – No source code changes or recompile required

Page 13: Sun fire x2250 technical training presentation

Page: 13 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Agenda

• Introduction

• Architectural overview

• Hardware

• Software

• Remote management

Page 14: Sun fire x2250 technical training presentation

Page: 14 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Internal Layout

High Efficiency Power Supply

2 Blowers cooling CPUsand DIMMs

2 SATA Drives

DVD

1 PCI-ExpressExpansion Slot

8 FB-DIMMSlots

2 Intel Xeon 5200/5400 CPUs

Page 15: Sun fire x2250 technical training presentation

Page: 15 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Chassis Design

3.5-inch SATA HDDTray load DVDLocator light Power buttonStatus LEDs USB ports

500W PSU x16 PCIe slotHD-15 VGA 2 Intel GigE Ethernet

3.5-inch SATA HDD

USB portsSER MGTNET MGT

Page 16: Sun fire x2250 technical training presentation

Page: 16 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Storage

• Two internal 3.5-inch 7,200 RPM SATA HDD> Intel SATA controller> RAID 0,1 – Windows only> 250 GB, 500 GB, and 1 TB disk drives available

– Mixing different density disk drives is supported

• Internal tray load DVD

• PCIe based HBA's> Sun StorageTek PCI Express x4 Dual Channel Ultra320 SCSI Host Bus Adapter> Sun StorageTek PCIe Enterprise 4Gb Fiber Channel Host Bus Adapter, Dual

channel> 4Gb Dual Fiber Channel PCIe Host Bus Adapter, Emulex> Sun StorageTek (TM) PCIe SAS Host Bus Adapter, 8 port pass-thru > 4Gb Single Fiber Channel PCIe Host Bus Adapter, Emulex> Sun StorageTek PCIe Enterprise 4 Gb Fiber Channel Host Bus Adapter, Single

Channel

Page 17: Sun fire x2250 technical training presentation

Page: 17 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 - I/O ports

• Three network ports> Two 10/100/1000 RJ45 connected to the host

MACs provided by Intel ESB, brought out through Gilgal PHY> One 10/100 RJ45 to the AST2000

• One serial port> TIA/EIA-232-F asynchronous RJ45 port routed through AST2000

• 5+2 USB ports> Two USB 2.0 front, two rear, one internal, two wired to AST2000

• One video port> Analog HD15 VGA connector

Page 18: Sun fire x2250 technical training presentation

Page: 18 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

PCIe Expansion Slot

• PCI-Express slot> Low Profile form factor> PCIe v1.0> x16 electrical, x16 mechanical> Right-angle riser> Connected to MCH

PCIe Riser

Page 19: Sun fire x2250 technical training presentation

Page: 19 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Dimensions and Rack Mount

• Same chassis as Sun Fire X2100/X2200 M2> Height x Width x Depth

– 43 x 425.5 x 633.7 mm

– 1.7 x 16.8 x 25.4-inches

> Maximum weight: 27.2 lbs (13.3 kg)

• Two 4-post rack mount options> Standard slide rail kit> Tool-less slide rail kit

– Snaps into most 3rd party racks

> Cable management kit– Ordered separately from slide rail kits

Page 20: Sun fire x2250 technical training presentation

Page: 20 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Power, Cooling

• One 500 Watt power supply> Non-redundant, non-hot swappable> High efficiency, 80+> 120/240V auto sensing> Built-in 2 cooling fans

• Three internal fans> Two blowers for main chassis area (CPU & memory)> One fan for PCIe cards

Page 21: Sun fire x2250 technical training presentation

Page: 21 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Cooling and Fans

• Cooling Front to Back

• Airflow provided by 3 Fans + 2 Blowers> 2 blowers forcing air to CPUs/DIMMs area> 1 fan for PCIe slot area> 2 fans in PSU

2 Air Blowers

Fan for PCIe slot area

Page 22: Sun fire x2250 technical training presentation

Page: 22 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Intel Xeon Processor ChoicesQuad Core ● X5472 ( 1600MHz FSB, 3.00GHz,120W) ● E5462 ( 1600MHz FSB – 2.80GHz – 80W) ● X5460 ( 1333MHz FSB – 3.16GHz – 120W) ● E5405 ( 1333MHz FSB – 2.0GHz – 80W) Dual Core ● X5272 (1600MHz FSB – 3.4GHz) 50W Quad Core ● L5420 ( 1333MHz FSB – 2.5GHz)

Memory Choices● 8GB 800MHz: 2x4GB● 4GB 800MHz: 2x2GB● 8GB 667MHz: 2x4GB● 4GB 667MHz: 2x2GB

Storage Choices ● 1TB SATA 7,200rpm ● 500GB SATA 7,200rpm ● 250GB SATA 7,200rpm ● DVD-ROM or 8x double-layer DVD burner● JBODs, RAID Arrays, Tape options (40+)

Infiniband, 10GbE, Fiber Channel, SCSI, SAS, Crypto● Sun Dual Port 4x Infiiniband (X1236A)-Z● Sun Dual Port DDR IB Host Channel Adapter (X4127A-Z) ● Sun Dual-Port Multi-threaded 10GbE NIC (X1027A) ● Sun Single-Port (Intel 82598 Controller) (X1106A-Z) ● Sun Dual-Port (Intel 82598 Controller) (X1107A-Z) ● Sun StorageTek dual-channel Ultra320 (SG-XPCIE2SCSIU320Z) ● Sun StorageTek 8-port SAS HBA (SG-XPCIE8SAS-E-Z) ● Sun StorageTek Dual-channel 4Gb FC HBA (SG-XPCIE2FC-QF4) ● Emulex 4Gb Dual FC HBA (SG-XPCIE2FC-EM4) ● Sun StorageTek 4Gb Single-channel FC HBA (SG-XPCIE1FC-EM4) ● Sun StorageTek 4Gb Single-channel FC HBA (SG-XPCIE1FC-QF4)● Sun 2-port Gigabit Ethernet NIC Copper (X7280A-2)● Sun 2-port Gigabit Ethernet NIC Fiber (X7281A-2)● Sun 4-port Gigabit Ethernet NIC Copper (X4446A-2) ● Sun Crypto Accelerator 6000 SSL/IPsec Accelerator (X600A) ●

Standard Configurations● One X5472, 2x 4GB 800MHz (X2250-14-H300-24-A) - $3,395● One E5460, 2x 2GB 667MHz (X2250-14-H316-22-A) - $2,995● One E5405, 2x 2GB 667MHz (X2250-14-M200-22-A) - $1,495● One L5420, 2x 2GB 667MHz (X2250-14-L250-22-A) - $1,995

Sun Fire X2250 Options

Page 23: Sun fire x2250 technical training presentation

Page: 23 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Agenda

• Introduction

• Architectural overview

• Hardware

• Software

• Remote management

Page 24: Sun fire x2250 technical training presentation

Page: 24 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Operating Systems

Operating System Notes

Solaris 10 8/07 Pre Installed

Red Hat Enterprise Linux 4.0 AS Update 6 64 bit version

Red Hat Enterprise Linux 5.0 AS Update 1 64 bit version

SuSE Linux Enterprise Server 10 w/ SP1 64 bit version

Microsoft Server 2003 Standard & Enterprise 32 & 64 bit version

VMWare ESX 3.5, ESXi Not Supported

Page 25: Sun fire x2250 technical training presentation

Page: 25 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Tools & Drivers

• Hardware Diagnostics (PC-Check)> DOS based diagnostics utility, run from CD/DVD> Writes results to diagnostics partition on primary HDD

• System BIOS/SP flash update utility> Updates BIOS and SP together

• OS specific drivers> Post-installation scripts for each OS> Microsoft Windows 2003 reburn script

Page 26: Sun fire x2250 technical training presentation

Page: 26 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Agenda

• Introduction

• Architectural overview

• Hardware

• Software

• Remote management

Page 27: Sun fire x2250 technical training presentation

Page: 27 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Remote Management

• ILOM 2.0> GUI and CLI based management> Remote KVMS> User access control

– Local users, LDAP, Active Directory

• Service Processor based on Aspeed AST2000> One 10/100 BaseT Ethernet (RJ45)> Serial port multiplexed with system serial port> BIOS flash upgrades via SP or host

Page 28: Sun fire x2250 technical training presentation

Page: 28 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Aspeed AST2000

• Embedded 200MHz ARM CPU

• BMC controller with IPMI 2.0/1.5

• Graphics controller> VGA/2D controller> 1600 x 1200 @ 60Hz

• Video Redirection over IP

• Storage over IP

• Single 10/100 Mbps MAC

Page 29: Sun fire x2250 technical training presentation

Page: 29 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – Management Interfaces

• All management interfaces call the same underlying system management functions, allowing the user to choose preferred access method> Secure web browser (GUI)

– Remote Console application

> Secure Shell (SSH) command line (DMTF SMASH CLP)> Serial port through terminal server or direct host attach> IPMI v2.0 command interface> Simple Network Management Protocol (SNMP)

Page 30: Sun fire x2250 technical training presentation

Page: 30 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – RKVMS

• Remote keyboard, video, mouse, and storage> Full video passed to remote application

– Max resolution 1600x1200

> Connect local CD/DVD or .iso image to host through SP

• Java Web Start application> Downloaded through secure web connection

Page 31: Sun fire x2250 technical training presentation

Page: 31 PRELIMINARY - SUBJECT TO CHANGE - Sun Proprietary/Confidential: Need to Know - Sun Employees Only

Sun Fire X2250 – System Sensors

• The service processor can monitor and report status and errors on the following system components > CPU core voltage> Memory voltage> System 3.3V, 5V, and 12V> System fans> CPU temperature> Chassis temperature

Page 32: Sun fire x2250 technical training presentation

Sun Fire X2250 Technical Training

Ronald [email protected]