sun solar street light - provprocure...c210 c240 c270 c300 c330 street side c0 house side max @ =...

8
SUN Solar Street Light

Upload: others

Post on 27-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

SUN Solar Street Light

Page 2: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

Provident Procurement SUN Solar Street Light

Page 3: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

Advantages

Tool free opening of the solar battery case.

Solar panel angle can be adjusted to maximumize efficacy

Weight is much less that of current products of the same power.

Easier maintenance, easier battery change.

High luminous efficacy up to 160lm/W.

More flexible compare to the traditional all-in-one product.

The Solar Panel can be upgraded in power while keeping large battery.

Installation beam angle is adjustable form 0 to 90 degrees, which is suitable for both vertical pole and arm pole installation

Page 4: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

7

Installation of the luminaire and pole

Wiring Diagram

Tools needed: Wire strippers, insulation tape Notice: If the external cable or cord of the fixture is damaged,the replacing work should be finished by the manufacturer or other service agent or similar qualified persons. And to avoid danger, the AC input cable that is connecting to the fixture should not be less than 1.25 mm2.

Our luminaire is suitable for 70mm to 76mm diameter luminaire arm. Specific installation as shown:

Rotating stents. Make the luminaire pole stand erect, Solar panel toward the equator (the north south in the northern hemisphere, the southern hemisphere) Then use the locking bolt to fix bracket.

Product Installation

L L

LBrownYellowGreen

Terminal

Power Supply Cabinet CoverN N

N

Loosen four screws Fix the luminaire on the arm Adjust to a suitable angle, fasten the screw nut

Step 1

Step 2

Step 3

Installation

AC Connection

Page 5: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

8

Ιtem No. Power (W)

CCTOptions

Luminous Flux (Lm)

Charge SolarPanel

PFIPCRI Beam Angle

Working Time100%/50%/30%

power

LIfe PO4

DImensions (mm)

840191

IK10 IP65

840133

20

30

4000K5000K5700K6500K

4000K5000K5700K6500K

3000

4500

12V 10A

12V 10A

140°x65°

140°x65°

5hrs/10hrs/34hrs

5hrs/10hrs/34hrs

990x390x204

990x390x204

17.5V/40Wp 12.8V/16AH

17.5V/60Wp 12.8V/26AH

≥0.9

≥0.9

65

65

>70

>70

Technical Parameters

232mm

Ø90mm

1140mm

382mm

530mm

204mm

990mm

Ø90mmØ84mm

390mm

354mm

840197

840194

840200

50

40

60

7500

6000

8000

140°x65°

140°x65°

140°x65°

5hrs/10hrs/34hrs

5hrs/10hrs/34hrs

5hrs/10hrs/34hrs

1140x530x232

1140x530x232

1140x530x232

17.5V/100Wp 12.8V/50AH

17.5V/80Wp 12.8V/32AH

17.5V/100Wp 12.8V/50AH

≥0.9

≥0.9

≥0.9

65

65

65

>70

>70

>70

IK10 IP65

Technical Parameters

4000K5000K5700K6500K

4000K5000K5700K6500K

4000K5000K5700K6500K

12V 10A

12V 10A

12V 10A

Ιtem No. Power (W)

CCTOptions

Luminous Flux (Lm)

Charge SolarPanel

PFIPCRI Beam Angle

Working Time100%/50%/30%

power

LIfe PO4

DImensions (mm)

232mm

Ø90mm

1140mm

382mm

530mm

204mm

990mm

Ø90mmØ84mm

390mm

354mm

9

Page 6: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

10 11

20W

30W 50W

40W

Luminous Intensity Distribution Diagrams Luminous Intensity Distribution Diagrams

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

C0/180,153.0deg Ic:754.1C30/210,138.5deg Ic:748.7

-30 C60/240,94.7deg Ic:923.8

dc:TINUd c:TINUd c:TINUd c:TINU

C90/270,83.5deg Ic:927.8

AVERAGE BEAM ANGLE(50%):117.4 DEG

0

400

800

1200

1600

2000 C30

C60

C90

C120

C150

C180

C210

C240

C270

C300

C330

STREET SIDE

C0

HOUSE SIDE γMax @ = 56.5DEG

0

400

800

1200

1600

2000

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180,151.9deg Ic:1218

UNIT:cd

C30/210,136.2deg Ic:1185

UNIT:cd

C60/240,85.3deg Ic:1457

UNIT:cd

C90/270,75.4deg Ic:1460

AVERAGE BEAM ANGLE(50%):112.2 DEG

0

600

1200

1800

2400

3000C0

C30

C60

C90

C120

C150

C180

C210

C240

C270

C300

C330

Max @ = 55.5DEGγHOUSE SIDE

0

600

1200

1800

2400

3000

AAAAAAAAAAAAAAAAA

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

C0/180,151.9deg Ic:1558C30/210,135.9deg Ic:1516

-30 C60/240,84.8deg Ic:1870

dc:TINUd c:TINUd c:TINUd c:TINU

C90/270,75.1deg Ic:1873

AVERAGE BEAM ANGLE(50%):111.9 DEG

0

700

1400

2100

2800

3500 C30

C60

C90

C120

C150

C180

C210

C240

C270

C300

C330

C0HOUSE SIDE γMax @ = 55.5DEG

0

700

1400

2100

2800

3500

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

C0/180,151.5deg Ic:2021C30/210,136.4deg Ic:1968

-30 C60/240,87.3deg Ic:2410

dc:TINUd c:TINUd c:TINUd c:TINU

C90/270,77.1deg Ic:2416

AVERAGE BEAM ANGLE(50%):113.1 DEG

0

900

1800

2700

3600

4500C30

C60

C90

C120

C150

C180

C210

C240

C270

C300

C330

C0

HOUSE SIDE γMax @ = 56.0DEG

0

900

1800

2700

3600

4500

Page 7: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

12

20W/30W

12m

10m

8m

6m

4m

30W/40W/50W

50W/60W

Pole Selections

60W

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

C0/180,151.6deg Ic:2396C30/210,136.5deg Ic:2345

-30 C60/240,87.1deg Ic:2877

dc:TINUd c:TINUd c:TINUd c:TINU

C90/270,77.0deg Ic:2886

AVERAGE BEAM ANGLE(50%):113.0 DEG

0

1100

2200

3300

4400

5500 C30

C60

C90

C120

C150

C180

C210

C240

C270

C300

C330

STREET SIDEC0

HOUSE SIDE γMax @ = 56.0DEG

0

1100

2200

3300

4400

5500

13Luminous Intensity Distribution Diagrams

Page 8: SUN Solar Street Light - ProvProcure...C210 C240 C270 C300 C330 STREET SIDE C0 HOUSE SIDE Max @ = 56.0DEG γ 0 1100 2200 3300 4400 5500 Luminous Intensity Distribution Diagrams 13

14

Suite 109, 1st FloorThe CatalystEbène [email protected]

https://provprocure.com/

+27 (0) 818 716 522

Contact Us