sun storedge library installation & operating manual(quantum oem) dae suk, kim([email protected])...
TRANSCRIPT
![Page 1: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/1.jpg)
SUN StorEdge Library Installation & Operating Manual(Quantum OEM)
Dae suk, Kim([email protected])Storage Business Dept. 1 Team
LOIT Co., Ltd
![Page 2: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/2.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
SUN StorEdge L25 Tape Library OEM of Quantum M1500
Supported Drive Type SCSI-LVD : SDLT320, LTO
Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal
Bridge(FC420) or External Bridge
Not Support Mixed Drive Max # of Cartridge Slot
21 DLT or 25 LTO slots Max Capacity : 5 TB Max # of Drives : 2 (All
Type) Barcode Label : Included Mix & Match L25 with L100
Libraries Up to 14 Drive & 175 slots
when scaled to seven modules
4u rack height Hot swappable tape drives
& power supplies Standard redundant power
supplies 250,000 hours MTBF
Front View
![Page 3: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/3.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
SUN StorEdge L100 Tape Library OEM of Quantum M2500
Supported Drive Type SCSI-LVD : SDLT320, LTO
Ultrium-1, LTO Gen II SCSI-HVD : LTO Ultrium-1 FC Interface : Internal
Bridge(FC420) or External Bridge
Not Support Mixed Drive Max # of Cartridge Slot
84 DLT or 100 LTO slots Max Capacity : 20 TB Max # of Drives : 6 (All
Type) Barcode Label : Included Mix & Match L25 with L100
Libraries Standalone & Rackmount
Configurations Hot swappable tape drives
& power supplies Standard redundant power
supplies 250,000 hours MTBF
Front View
![Page 4: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/4.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Hardware 구성도
Terminator
X6758A(Ultra3 HBA)
![Page 5: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/5.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Library Setup Order 1. Host 에 Scsi Cable 연결 & Library Power On (11 번 Slide 참
조 ) 2. Library Inventory 종료 후 Media Import (11 번 Slide 참조 ) 3. OS 상에서의 St Driver & Ultra3 Patch 확인 , Patch(6 번 Slide
참조 )
4. Tape Device 생성 가 . OK mode : OK> boot –r 나 . MultiUser Mode : # reboot -- -r or #drvconfig;tapes;
(Online Rebuild) 5. OS 상에서의 Device 생성 확인 가 . #luxadm inq /dev/rmt/ 테잎순서 or # /dev/rmt/ 밑에 device 생성되었는지 확인 나 . Netbackup or NetWorker 상에서 changer & tape 확인
#sgscan –v changer;sgscan –v tape (Netbackup Utility)
#inquire (Networker Utility)
6. Robot Test
가 . #/usr/openv/volmgr/bin/robtest 로 미디어 제어확인
ex) init , test_ready etc …
![Page 6: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/6.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
ST Driver Patch Required Scsi Type 에 맞는 HBA Card 장착
Ultra3 SCSI(LVD) 160m/s : X6758A Ultra2 SCSI(LVD) 80m/s : X2222A Ultra Differential(HVD) 40m/s : X6541A Ultra Differential Fast/Wide(HVD) 40m/s : X6749A(EOL)
Device Server 쪽에 current version st.conf 등록 Version 별 Patch Name
Solaris 2.6 : 105847 Solaris 7 : 107460 Solaris 8 : 108725 Solaris 9 : 13277
LVD tape drive 는 Solaris 7, 이하 버전 지원못함 Device Server 쪽에 Ultra3 patch(Ultra 3 Scsi 일 경우 )
SUNWqus.tar.Z [66K] SUNWqusx.tar.Z [68K] SUNWqusu.tar.z [3K] SUNWqusux.tar.Z [4K]
![Page 7: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/7.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Performance Tunning HBA 의 최대 속도와 Library 의 속도 확인
X6758A(Ultra3 SCSI) 의 경우
HBA 속도 : 160m/s(Dual Port), 한 개 Port 는 Maximun 80m/s 지원
LTO2 Drive( 초당 30m/s) 지원 L8 Library 의 경우 Robot 과 Drive 가 같은 Port 를 사용하므로
X6758 한 개 Port 만으로도 드라이브 속도를 충분히 소화할수 있음
Drive 가 여러 개인 경우 / Robot Scsi Port 가 분리된 경우 (L25/L100/L180)
HBA 의 한 개 Port 의 Maximun Speed 와 드라이브 속도 체크 Ex) Drive 가 3 개인 경우 Library 쪽 port 는 Maximum 4ea(Robot 1ea / Drive
3ea) Robot 3ea 를 Jumping 할 경우 90m/s 를 지원해야 함 따라서 X6758 의 경우 80m/s 밖에 지원이 안되므로 나머지
port 를 사용하여 Library 쪽에서두개의 Line 을 사용하는 것이 바람직함
(Robot+Drive1ea = 1 개 channel / Drvie2ea = 1 개 channel)
Robot 에 연결된 Scsi Fail 시 Drive 작동이 전혀 불가하므로 가능하면 Redundancy 차원의 Scsi Cable 을 분리하여 잉여 드라이브를 사용 권장
![Page 8: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/8.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Connect Library to the HOST Cabling Diagram
Single SCSI BUS HBA Card 의 속도가 Drive
2ea 를 지원하고 한 개 Port 만 사용시
Two SCSI BUS 분리된 HBA Card or Port 를
사용하여 속도 & Redundancy 고려
Three SCSI BUS Drive, Robot 을 전부 분리 ,
HBA Card or Port 를 사용하여 속도 & Redundancy 고려
![Page 9: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/9.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
L100 Recommended Cabling Cabling Diagram
X6758A 3개
![Page 10: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/10.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Hardware Installing Order Drive Installing Tape Labeling
Unpacking L25 Base / Drive / Tape
HVD / LVD Type 고려하여 Drive installing(Max 2ea)
Tape Barcode Labeling 쓰기방지탭 조정
Left : Enabled Right : Write-Protected
필요시 Management Card 추가 장착
Write Protect Switch Setup
![Page 11: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/11.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Hardware Installing Order Remove magazine & Inserting Tapes
L25 Power Off 시 : 펜을 이용하여 release button 을 누른후에 Magazine 분리
Power On 시 : LCD Pannel Key 조작을 이용하여 Main-Mags-Release 사용 Labeling 된 Tape 을 Magazine 에 삽입한다 ( 상하주의 , 강제삽입 금지 ) Tape 분리시 : Cartridge retaining latch 를 누른 상태에서 분리 Cleaning Tape : L25 Magazine 빼낸 후 안쪽의 Fixed Slot 에 직접 삽입
![Page 12: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/12.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Powering Up the Library Connect L25 Library to AC Power
Library run Post-On-Self-Test(POST)
Power ON Initializing 을 통해 자동
inventory 및 Self Test실행
완료시 GUI 에 Drive / Slot 별 Media Status 출력
각 GUI Screen 의 하단에 5개 Button label 로 조작
![Page 13: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/13.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Disabling Unused Drive Bays Using the GUI Buttons
사용하지 않는 Drive Bay Setup Main GUI -> Press Menu -> Press
Config Unused drive bay 에 highlight
될때까지 up, down key 로 조작후 Press Select
Press Down Button Until Disabled Setup 완료후 main screen 으로
돌아가지 않으면 NVRM 에 저장되지 않는다 Setting 이 제대로 인식되기 위해 반드시
Library 를 Reboot 한다
![Page 14: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/14.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Library Features Front Panel Graphical User Interface(GUI)
라이브러리 상태 정보 , 라이브러리 메뉴를 액세스 할수있게 해줌
Library Setting 값의 View & Change, daemonstration programs 의 구동 , diagnostic tests
Magazine door buttons Mags option 을 사용하여 Unlocked
magazine 을 열때 , Power-Off & magazine Open 시 사용
Light Emitting Diode(LED) Green LED : 호스트 채널로부터 액세스
가능하도록 Full Operational & Ready 상태
Green LED Flash : Ready 상태에서 NOT Ready 상태로 변환되는중
Power-On-Self-Test 시 Magazine Release 상태일 경우 특정 menu Item access 시
Red LED : Library Error
![Page 15: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/15.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Library Features
Internal Layout
Back Pannel
![Page 16: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/16.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
GUI Icon Status No tape
present
Tape Loading
Tape Unloading
Tape Unloaded
Tape Idle
Tape Rewinding
Location Data
Reading Data
Writing Data
Power On
Drive Fault
Tape Is Write-Protected
Drive Need Cleaning
Slot Empty
Solt Occupied
Slot Occupied – no Label
or Bad barcode
![Page 17: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/17.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Library & Drive & Inventory Info. Main GUI -> Press
Quick View -> Press Library or Drive or Inventory
Modelaud / Code Revision, Scsi ID 기타 정보 확인
Library 가 L100이상이거나 Stack Link인 경우는 Level button을 이용하여 각단계별 Inventory 확인
![Page 18: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/18.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Release Magazine & Drive Power
Main GUI -> Press Quick View -> Drv Pwr
Power-On, Off 시킬 Drive Select
해당 Drive highlishted 되면 Up, Down button 으로 현재 Setting 변경
Tape Drive Hot-Swapping에 주로 사용
Magazine 을 분리하기 위해 Library On 상태에서 실행
Main GUI -> Press Mags -> Release Magazine 창에서
Left / Right / Both 중 Open시킬 Magazine 선택 , select
전면 Magazine door button누른 후 Magazine 분리 , 작업
완료후 Re-Lock
![Page 19: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/19.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Moving Tape Cartridges Main GUI -> Press
Menu -> Press Move -> Move Cartridge FROM
Up, Down 키로 이동시킬 미디어를 선택한후 Select Key Press
->Move Cartridge TO 에서 이동시킬 Slot or Drive 에 커서 위치시키고 Select
->Confirm Move Cartridge 로 최종 확인
완료시 : Moving Cartridge…. Please Wait 출력후 Move Cartridge FROM GUI Displayed again
Press Back button
Press Main button
![Page 20: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/20.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Scsi History & Library Statistics
Main GUI -> Press Menu-> Press Service -> Press Stats
-> Library or Drive or Scsi History 중 택 1
날짜 또는 시간별 SCSI Bus Command history 상태 / Library, Drive Detail Statistics 확인
![Page 21: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/21.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Changing the Library Configuration Changing the Baud Rate Setting
Serial Diagnostics port 접속을 위한 baud rate Control
Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select baud rate -> Press Select -> up & Down, select desired Baud Rate
Setting the Time & Date
Library Time & date 설정
Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Time or Date -> Press Select -> up & Down, select correct date, time
Changing the AUTO-Clean Setting
Default Setting -> Disabled, Hardware 적으로 적정 시점에 Cleaning 할수 있도록 Setup( 권장 ) / Backup S/W 의 clean setup 사용시보다 관리 용이
Main GUI -> Press Menu -> Press Config -> Press Up & Down -> Select Auto-Clean -> Press Select -> up & Down, select Enabled
![Page 22: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/22.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Performing Maintenance Operations
수동 Cleaning 시 사용 Main GUI -> Press Menu ->
Press Service -> Press Maint -> Press Clean -> DisPlayed “Select Cleaning Cartridge screen” -> 클리닝 카트리지 선택 -> DisPlayed “Select Tape Drvie” -> 클리닝할 드라이브 선택
Cleaning a Tape Drive Adjusting the Contrast
Main GUI -> Press Menu -> Press Service -> Press Maint -> Press Contrast
원하는 Contrast 까지 Increase or Decrease Button Press
![Page 23: SUN StorEdge Library Installation & Operating Manual(Quantum OEM) Dae suk, Kim(rowcols@loit.net) Storage Business Dept. 1 Team LOIT Co., Ltd](https://reader035.vdocument.in/reader035/viewer/2022062312/5519ec1e5503469c0b8b4741/html5/thumbnails/23.jpg)
2004 Loit Co., Ltd Storage Business Dept. 1 Team
Related Documentation
Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library Installation Guide
- Explains how to install a stand-alone Sun StorEdge L25 Tape Library or Sun StorEdge L100 Tape Library
Sun StorEdge L25 Tape Library and Sun StorEdge L100 Tape Library User's Guide
- Describes the Sun StorEdge L25 Tape Library and the Sun StorEdge L100 Tape Library and their use.
H/W 장애시 LCD 에 출력되는 Fault System Code(FSC) Dictionary 참조 , TroubleShooting
Thank You!