supervisor : samir arfaoui by: fatma helal sawy

28
1 Supervisor: Samir Arfaoui By: Fatma Helal Sawy Scintillator Tiles Studies CLIC detector and physics study CLIC dp

Upload: fritz-moran

Post on 01-Jan-2016

51 views

Category:

Documents


0 download

DESCRIPTION

Supervisor : Samir Arfaoui By: Fatma Helal Sawy. CLIC dp. CLIC detector and physics study. Scintillator Tiles Studies. CLIC detector concept. Interaction point. Tracking system:  records the paths taken by charged particles. Electromagnetic calorimeter - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

1

Supervisor:

Samir ArfaouiBy: Fatma Helal Sawy

Scintillator Tiles Studies

CLIC detector and physics study

CLIC dp

Page 2: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

2

CLIC detector concept Tracking system: records the paths taken by charged particles

Interaction point

4-5T Solinod

Electromagnetic calorimeter( ECAL): measures energy of photons and electrons as well as the early parts of showers initiated by hadrons.

Muon system

Return yoke: is type of iron used for confining the magnetic field that’s why it’s compact detector.

The Hadron Calorimeter (HCAL) measures the energy of hadrons.

Muon system

Page 3: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

3

ECAL for Linear Collider(LC)

Page 4: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

4

Scintillator calorimeter for LC

Absorber

Elect

rons

: Bre

mss

trahlu

n

g

Scintillator

StripReadout system

SiPM:Photoelectric effect

ElectronicsAcquisition

Photons: Pair production

Tile

Page 5: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

5

Before building, we need testing

What is the best cell size? How much light do we collect?

Does it have a uniform response?

The first step in building calorimeter with millions of cells, is building one cell.

And to build this unit cell, we made test to get answers on that these questions

Page 6: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

6

The Task

Do lab test on different plastic scintillators tiles to answer these

questions

Page 7: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

7

Procedures

Experimental setupCalibration

Measurements (Scan)Data acquisition

Data AnalysisResults(Answers)

Page 8: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

8

A.Experimental setupElectron gun

Devi

ce U

nd

er

Test

Feed

thro

ug

hto

lab

next

door

Page 9: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

9

The system Ingredients

Electron gunIt's sr90 source.double beta emission.

Page 10: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

10

The system Ingredients

Triggering systemGoal: trigger on particles that went

through scintillator Crossed scintillating fibers (20x1x1 mm³) as trigger, fixed

underneath DUT Each fiber is read out by a SiPM

Both SiPM signals are put in coincidence

Page 11: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

11

Readout system

Scintillator is direct coupling with SiPM using optical grease.

Page 12: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

12

Place selected DUT in setup Switch electron gun ON Start automated scan At each scan step (~60 sec):• define position(x, y) • Recording integration of SiPM signals for each trigger.• Measure temperature

With the gun off, perform self-triggered run to measure gain at

reference temperature

Measurements

Calibration

Page 13: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

13

Data acquisition

High voltage power supply for SiPM bias

Feedthrough to dark room

Coincidence circuit for triggering system (NIM)

Low voltage for amplifier

Current source for electron gun coil

Scalers

Page 14: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

14

Data Analysis:Each scintillator is divided into number of

positions; each position is 1 x 1 mm².Get average light yield of each position.Create light-yield map for the whole

scintillator.

30 x30 scintillator

Page 15: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

15

Data Analysis:Every scanned position is affected by

two main factors: The position of SiPM

Temperature variation.

Page 16: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

16

Uniformity study+/- 5% +/- 10% +/- 20%

92.5 98.9 100.0

Page 17: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

17

Full scan for 20x20x1 mm³ wrapped scintillator

Page 18: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

18

Page 19: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

19

Page 20: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

20

Back up

Page 21: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

21

CLIC d

etec

tor a

nd phys

ics

study

CLIC d

p

Page 22: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

22

The Task

What is the best cell size? How much can cell collect light ?

Is it have uniform response?

Before building the whole scintillator, we need first built one cell. So we do lap test on different plastic scintillator cells to answer that questions.

Page 23: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

23

Calorimeter for Linear Collider(LC)

Page 24: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

24

A.Experimental setup

Page 25: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

25 Experimental Setup

Devise Under test

Triggering systemTriggering

system

Page 26: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

26

Page 27: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

27

Backup

Page 28: Supervisor : Samir  Arfaoui By: Fatma  Helal Sawy

D. Schulte, Future Collider Technologies, CERN 2014

CLIC: The BasisDrive Beam Generation Complex

Main Beam Generation Complex

Goal: Lepton energy frontier CLIC at 3TeV shown