FEATURES• Onlinedoubleconversion
• High-reliabilityandperformanceDSPcontrol
• Powerfactorcorrection
• Cold-startcapability,batterycold-start
• Batterypowermanagement
• Smartventilation
• ECO-INDmode
• IGBTInverter
• Maintenancebypassincluded
• Automaticelectronicbypass
• Automaticsafetyshut-offatinput
• Outputisolationtransformerincluded
• SNMPnetworkcardincluded
• Smartbatterymonitoringsystem
SUPPLEMENTALOPTIONS
• Technologyforparallelcapacityorredundancy
• Externalbaterrybankextendedbackuptime
• Industronicpowerconditioner/voltageregulatortoprotecttheUPSandextendedbatterylife
APPLICATIONS• Sites
• Datacenters
• Instrumentationequipment
• Robotics
• Buildings
• Malls
• Offices
TECHNICAL SPECIFICATIONS
• Inputvoltagerange 120/208,127/220,220/380,254/440or277/480VAC(+-20%)Deltaconfigurationavail-able
• Outputvoltageoptions 120/208,127/220,220/380or277/480VAC(+-1%)
• PowerFactor 0.8(optional0.9)
• Efficiency 90%
• Outputdistortion Lessthan3%THD(linealload)
•Isolationtransformer Output:Drytipe
i
•Overloadprotection Thermal-magneticbreaker
• Outputoperatingfrequency 60Hz+-0.2%(optional50Hz+-0.2%)
• Transfertime 0.0miliseseconds(online)
• Interface RS-232andRS-485UPSsmartcardforSNMPnetworkincluded
•ConfigurationTower
•AlarmtypeAudible
• Backup 5min.at100%load,dependingonthemodel,13min.at50%load,dependingonthemodel
www.industronic.com.mx
Uninterruptible Power System (UPS)
V I S I T U S O N T H E I N T E R N E T
YEARS
IND
USTRONIC
WARRAN
TY2
SPECIFICATIONS
Display
Controlpanel
Maintenancebypassswitch
SNMPnetworkcard
Outputpowerswitch
Inputpowerswitch
Batteryswitch
Bypassswitch
UPS-IND1300
Inputandoutputconnections
Batteries
Emergencyshut-offbutton
11127/220 or 120/208 configuration option 22220/380, 254/440, 266/460 or 277/480 configuration option**Weights and measurements are approximate, without packaging.Because of the continuous improvements in our products, the specifications are subject to change without notice.
Capacity (kW / kVA)
Overload protection
Voltage (VAC)
Range
PhasesFrequency (Hz)
Power factor
Overload protectionPower factor
Voltage (VAC)RangeFrequency (Hz)
Waveform
Transfer time (ms)
Connection typeOverload
Voltage (VDC)
Battery type
Backup time at full load (min)
Maximum load current (A)Battery bank
Battery bank dimensions (width x depth x hight in cm) **
Battery bank weight (lb)**
Audible noise (dB)
MTBF (hrs)
Operating temperature
Relative humidity
Maximum operating altitude (FASL)
Cabinet
Dimensions (width x depth x height in cm)**
UPS weight (lb)**
Conversion type
Rectifier
Inverter switch components
Filters
Isolation transformer
Battery status
Heat dissipation (kBTU / h)
Internal Bypass
Paralleling
Certifications
Communications interface
Screen (monochromatic LCD)
Alarm
Protection
INPUT
OUTPUT
BATTERIES
PHYSICALANDMECHANICAL
TECHNOLO
GY
Thermal-magneticbreakeratinputandbypass
+-20%at100%,+-25%al75%load,and+-30%al50%load
Inthree-phasesstar(4wires+ground)ordelta(optional)configuration(4wires+ground)60+-10%(50+-10%optional)
0.80no-load,>0.95fullload
Thermal-magneticbreakeroutput
0.8(optional0.9)
+-1%,typical
60+-0.2%(50+-0.2%optional)
PuresinewaveTHD≤3%(linealload)0.0(online)
Starconfiguration(3phases,4wires+ground)
130%ofthereatedloadfor60seg.;150%for10seg.
Sealedmaintenance-freeleadacid,ornickel-cadmium(optional)
<65,at3feet
233,000
0-40°C(32-104°F)
0-95%withoutcondensation
6,600at100%and9,800at96%Steelwithelectrostaticepoxypaint
Onlinedoubleconversion
SCR6-pulsetypewithphasecontrol
Pulse-widthmodulation(PWM)technologywithIGBT
Contraharmonicmean(loop:2%RMS)
Dry-typetransformerincludedatoutput
Informationonlineorviareal-timedownloadwithaccuracyof±3%
Twobypasses:oneautomaticstaticandonemanualformaintenance
n+1upto4piecesofequipment
CE-IEC62040-1,ISO9001:2008,NOM
RS-232,RS-485,dry-contactrelaysignal,SNMPnetworkcardincluded,orMODBUSEthernetwithoneequipmentportandtwoparallelports
Backlit:inputandoutputvoltage,loadcapacity,batteryvoltage,operatingstatus
Overload,irregularalternatingcurrentinputandlowbattery
Lowbattery,overheating,shortcircuit,outputvoltagesurge,lowoutputvoltage
926 992 1,058 1,102860 904 1,146 1,279
192 192 192 192348 348 348 348
50x80x160 50x80x160 50x80x160 50x80x16080x80x160 80x80x160 80x80x160 80x80x160
Integrated Integrated Integrated Integrated
Integrated Integrated Integrated Integrated
Internal
8-22 5-15 5-7 5-95 524
5 51812
Internal Internal InternalExternal External External External
28x70x66
22 33 44 67 36
28x70x66 28x70x66 48x80x171
236 243 331 485 613375 375
3.0 4.5 6.1 9.1
MODEL UPS-IND1358UPS-IND1346
8(9)/10
120/2081
120/2081
120/2081
120/2081
120/2081
120/2081
120/2081
120/2081
277/4802
277/4802
277/4802
277/4802
277/4802
277/4802
277/4802
277/4802
12(13.5)/15 16(18)/20 24(27)/30
UPS-IND1350 UPS-IND1353
1
3
5
6
4
11
7
8
9
2
10
11
10