supracor e brochure
TRANSCRIPT
![Page 1: Supracor e brochure](https://reader036.vdocument.in/reader036/viewer/2022082921/555ee39ad8b42a772f8b588f/html5/thumbnails/1.jpg)
Technolas Perfect Vision GmbHMesserschmittstr. 1 + 380992 München, Germanywww.technolaspv.com
True Bi lateral Mult i focal Exc imer Treatment for Presbyopia
A small step for you. A giant leap for your practice.
Your key to outstanding visual outcomes!
True bilateral presbyopia treatmentEquivalent treatment for both dominant andnon-dominant eye
Unique ablation pro7le for enhanced depth of 7eld
Excellent far, intermediate, and near visionSophisticated algorithm minimizes undesiredinduction of aberrations within the pupil
Designed for the full refractive treatment rangeHyperopia (CE-marked), myopia*, emmetropia*
Customization for individual patient needs
Potentially suitable for patientswith previous LASIKsurgery*
As simple as a LASIK procedureSuitable for subsequent enhancement surgeries
Fully controlledX/Y/Z Static and Dynamic Rotational EyetrackingIris Recognition
*SUPRACOR for myopic, emmetropic, and post-LASIK patientsis currently in clinical evaluation.
“SUPRACOR delivers excellent results.SUPRACOR is now my /rst choice for presbyopicpatients”Dr. Jorge Castanera, Barcelona, Spain
your key to the growing presbyopia market !
True bilateral treatment with MULTIFOCAL profile for each eye
Treats a wide range of patients
As simple as a LASIK procedure
Excellent far, intermediate, and near vision performance**
** Technolas Perfect Vision data on file
![Page 2: Supracor e brochure](https://reader036.vdocument.in/reader036/viewer/2022082921/555ee39ad8b42a772f8b588f/html5/thumbnails/2.jpg)
True bi latera l mult i focal excimer treatment for presbyopia
results speak for themselves !Cl in ica l data from a European Mult icenter Cl in ica l Study (4 s i tes)
SUPRACOR is a new generation of bilateral presbyopiatreatment that can give your patients the spectacle-free lifestyle they are seeking.SUPRACOR’s unique multifocal ablation proMle andsophisticated algorithm provide the expected nearaddition while minimizing the induction of undesiredaberrations within the pupil.
Designed for the full refractive treatment range,SUPRACOR is also potentially suitable for patients withprevious LASIK surgery*.
Key Indications
Bilateral Procedure (no monovision)No need to distinguish betweendominant/non-dominant eye
Spherical EquivalentUp to +4D
AstigmatismUp to +2D
Near Addition+1.5D or higher
ContraindicationsCommon LASIK contraindications (keratoconus,pachymetry, diabetes…)
Figure 1 SUPRACOR minimizes undesired aberrations within the pupil for better visual acuity
A ray-trace module using actual post-op topography data and point spread function is usedto simulate the retinal images for objects in near, intermediate, and distant positions.
Figure 4 SUPRACOR patients alsoshow excellent improvement ofmonocular vision
SUPRACOR treatment results inexcellent improvement of mono-cular uncorrected near visualacuity (UVNA) in combination withgood monocular distance visioncontrol.
Figure 2 91% of SUPRACOR patientsachieved binocular UNVA of J2 orbetter at 1 week.
At 1 week post-op, 91% of 23 patients(46 eyes) achieved binocular uncor-rected near visual acuity (UNVA) of0.8 (J2) or better. These resultsremained stable through the 6 monthspost-op examination.
Figure 3 96% of SUPRACOR patientsachieved binocular UDVA of 20/25 orbetter at 6 months.
For the same patients, binocularuncorrected distance visual acuity(UDVA) increased steadily post-opuntil at 6 months, 96% of patients(46 eyes) achieved UDVA of 0.8(20/25) or better.
Monocular uncorrected distance and near visual acuity
Figure 5 87% of SUPRACOR patients achieved binocular visual acuity of J2 and 20/25 or better simultaneously
Figure 6 SUPRACOR patients report signiMcant improvement in near and intermediate vision
NearVision IntermediateVision
What can you read without glasses?
Pre-op UDVA and UNVA Post-op UDVA and UNVA
Patients answered questionnaires at each visit to report on their functional vision during day-to-day activities.SigniMcant improvement and satisfaction were reported for different reading conditions ranging from packageinserts to computers. Further responses to the patient questionnaire (not illustrated) found 96% of patients arecomfortable without glasses indoors and outdoors, and 96% are satisMed with the outcome of the treatment andwould recommend the surgery to friends.
Comparison of the pre- and post-operative binocular uncorrected near and distance visual acuity results show asigniMcant improvement post-operatively, with 87% achieving a minimum J2 and 20/25 simultaneously at 6 monthsfollow up.
Do you need glasses for the computer?
*SUPRACOR for myopic, emmetropic, and post-LASIK patients is currently in clinical evaluationSome of the products and/or speciMc features as well as the procedures featured in this document may not be approved in your country and thus may not be available there. Design and speciMcationsare subject to change without prior notice as a result of ongoing technical development. SUPRACOR is CE marked but NOT approved for use in the US. Please contact our regional representativeregarding individual availability in your respective market. The trademarks (™ and ®) and logos used in this document are the property of Technolas Perfect Vision GmbH or the respective owner.Design by kbcomunicacion. Ref. TPV-065/09-2011©2011 Technolas Perfect Vision GmbH. All rights reserved.