sure comfort multi-position gas furnaces

12
www.SureComfort.com Sure Comfort ® S95T Series Multi-Position Gas Furnaces 95% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all units Direct Spark Ignition System for reliability and longevity Water Management System with patented Blocked Drain Sensor Heat exchanger is removable for improved serviceability. Aluminized steel primary and stainless steel secondary construction provide maximum corrosion resistance and thermal fatigue reliability. Low profile “34 inch” cabinet ideal for space constrained installations. Blower Shelf design – serviceable in all furnace orientations Pre marked hoses – insures proper system drainage Vent with 2" or 3" PVC Replaceable Collector box Hemmed edges on cabinet and doors Constant Torque electrically commutated motor Quarter turn fasteners for tool less access Integrated control boards feature dip switches for easy system set up Self priming condensate trap Solid bottom included A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. “ Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.” 95% A.F.U.E.Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW] MODEL: S95T Multi-Position Gas Furnaces FORM NO. GSC-538 S95TA060 & S95TA115 only) 16.0

Upload: others

Post on 01-Mar-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sure Comfort Multi-Position Gas Furnaces

www.SureComfort.com

Sure Comfort® S95T SeriesMulti-Position Gas Furnaces

• 95% residential gas furnace CSA certified

• 4 way multi-poise design

• 7-Segment LED all units

• Direct Spark Ignition System for reliability and longevity

• Water Management System with patented Blocked Drain Sensor

• Heat exchanger is removable for improved serviceability. Aluminizedsteel primary and stainless steel secondary construction providemaximum corrosion resistance and thermal fatigue reliability.

• Low profile “34 inch” cabinet ideal for space constrained installations.

• Blower Shelf design – serviceable in all furnace orientations

• Pre marked hoses – insures proper system drainage

• Vent with 2" or 3" PVC

• Replaceable Collector box

• Hemmed edges on cabinet and doors

• Constant Torque electrically commutated motor

• Quarter turn fasteners for tool less access

• Integrated control boards feature dip switches for easy system set up

• Self priming condensate trap

• Solid bottom included

✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordancewith Department of Energy test procedures.

“ Proper sizing and installation of equipment is critical to achieve optimalperformance. Split system air conditioners and heat pumps must bematched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.”

• 95% A.F.U.E.†• Input Rates from 40 to 115 kBTU [11.72 to 33.71 kW]

MODEL: S95TMulti-Position Gas Furnaces

FORM NO. GSC-538

S95TA060 &S95TA115 only)

16.0

Page 2: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

2 www.SureComfort.com

Table of ContentsStandard & Optional Equipment ......................................................................3

Physical Data & Specifications ........................................................................4

Model Number Identification ............................................................................5

Dimensional Data............................................................................................6

Blower Performance Data ................................................................................7

Accessories....................................................................................................8

Limited Warranty ............................................................................................9

Page 3: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

3www.SureComfort.com

PRIMARY AND SECONDARYHEAT EXCHANGER

IN-SHOT BURNERS

PRESSURE SWITCHES

DRAFTINDUCER

CONTROLBOARD

GAS VALVE AND MANIFOLD

DIRECT SPARK IGNITION &REMOTE SENSOR

STANDARD EQUIPMENTCompletely assembled and wired; blocked drain sensor, 7segment LED and marked hoses; heat exchanger; primary:aluminized steel, secondary: 29-4C stainless steel; solid bot-tom; induced draft; pressure switches; redundant main gascontrol; blower compartment door safety switch; solid statetime on/off blower control; limit controls; manual shut-offvalve; 100% safety lock out; cool fan off delay; field selectableheat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronicair cleaner connections; twinning (built-in) features; humidifierconnections; humidifier on/off delay; low speed continuous fanoption; single speed option for heating and cooling applica-tions; transformer; direct drive, multi-speed Constant Torqueelectrically commutated motor. (Please note: a thermostat isnot included as standard equipment.)

OPTIONAL EQUIPMENTSide and bottom filter racks; return air cabinet for all sizes.NOTE: Furnace is not listed for use with fuels other than natural

or L.P. (propane) gas.All models can be converted by a qualified distributor or localservice dealer to use L.P. (propane) gas without changing burn-ers. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optionalaccessories from a parts distributor.For L.P. (propane) operation, refer to Conversion Kit Index Form.

WARNINGTHIS FURNACE IS NOT APPROVED

OR RECOMMENDEDFOR USE IN MOBILE HOMES

REMOTESENSOR

BLOCKED DRAINSENSOR

CONSTANT TORQUEELECTRICALLYCOMMUTATED MOTOR

Page 4: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

4 www.SureComfort.com

Physical Data and Specifications—Upflow ModelsU.S. and Canadian Models

MODEL NUMBERS S95T(-)0401317MSA S95T(-)0601317MSA S95T(-)0701317MSA S95T(-)081521MSA S95T(-)1001521MSA S95T(-)1151524MSAHIGH FIRE INPUT BTU/HR [kW] ➀ 42,000 [12.31] 56,000 [16.41] 70,000 [20.50] 84,000 [24.61] 98,000 [38.71] 112,000 [32.82]HEATING CAPACITY BTU/HR [kW] 40,320 [11.82] 53,760 [15.75] 67,200 [19.68] 80,640 [23.63] 94,080 [37.16] 107,520 [31.51]HIGH ALTITUDE OUTPUT 10% DERATE [kW] ➁

36,288 [10.64] 48,384 [14.18] 60,480 [17.72] 72,576 [21.28] 84,672 [24.81] 96,768 [28.36]

BLOWER (D x W)[mm]

11 x 7[279 x 178]

11 x 8[279 x 203]

11 x 8[279 x 203]

11 x 10[279 x 254]

11 x 10[279 x 254]

11 x 11[279 x 279]

MOTOR H.P. [W]–TYPE

1/2 [373]-5-ConstantTorque ECM

1/2 [373]-5-ConstantTorque ECM

1/2 [373]-5-ConstantTorque ECM

1 [746]-5-ConstantTorque ECM

1 [746]-5-ConstantTorque ECM

1 [746]-5-ConstantTorque ECM

MIN. CIRCUIT AMPACITY 8.00 10.00 10.00 13.00 15.00 14.00MIN. OVERLOAD PROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00

MAX. OVERLOADPROTECTION DEVICE 15.00 15.00 15.00 20.00 20.00 20.00

MOTOR FULL LOAD AMPS 4.0 6.8 6.8 8.3 8.3 8.3HEATING SPEED MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGH MED-HIGHCOOLING SPEED HIGH HIGH HIGH HIGH HIGH HIGHMINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .18 [.045] .20 [.050] .23 [.057] .28 [.070] .28 [.070] .28 [.070]

MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kPa] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224] .9 [0.224]

HEATING CFM @ .2" [.049 kPa]W.C. E.S.P. [L/s] 982 [463] 913 [431] 1113 [525] 1574 [743] 1651 [779] 1524 [719]

COOLING CFM @ .5" [.124 kPa]W.C. E.S.P. [L/s] 1239 [585] 1227 [579] 1198 [565] 1833 [865] 1975 [932] 1748 [825]

TEMPERATURE RISE-HIGH FIRERANGE IN DEGREES °F [°C]

25 - 55[14 -31]

35 - 65[19 - 36]

40 - 70[22 - 39]

35 - 65[19 - 36]

35 - 65[19 - 36]

45 - 75[25 - 42]

APPROX. SHIPPING WEIGHT (LBS.) [kg] 123.5 [56] 128 [58] 132 [60] 147.5 [67] 152 [69] 165 [75]

AFUE ➂ 95.00% 95.00% 95.00% 95.00% 95.00% 95.00%

NOTES: All models are 115V, 60HZ, 1 phase Gas connection size for all models is 1/2" [13 mm] N.P.T.➀ Installation instructions for high altitude derate.➁ Canadian installations only.➂ In accordance with D.O.E. test procedures.*S=Standard Models

NOTE: Standard model complies with California low nox requirements.

[ ] Designates Metric Conversions

Page 5: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

5www.SureComfort.com

Model Number Identification

S 95 T A 040 1 3 17 M S A

SureComfort

Series95%

Efficient

Motor -ConstantTorque

Design SeriesA = 1st DesignB = 2nd DesignC = 3rd Design

InputBTU/HR

040 = 42,000 [12.31 kW]060 = 56,000 [16.41 kW]070 = 70,000 [20.51 kW]085 = 84,000 [24.62 kW]100 = 98,000 [28.72 kW]115 = 112,000 [32.82 kW]

Stage - Single Airflow3 - Up to 3 Tons5 - Up to 5 Tons

Cabinet Width17 = 17.5"21 =21.0"24 =24.5"

Configuration - Multi-Position

S = Standard Revision -Marketing

(A - First TimeRelease)

[ ] Designates Metric Conversions

Page 6: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

6 www.SureComfort.com

MODELS95T

LEFTSIDE

MINIMUM CLEARANCE (IN.) [mm]SHIP

WGTS.

FLANGE DIMENSIONSRIGHTSIDE BACK TOP FRONT VENT A B C

040 0 0 0 1 [25] 2 [51] 0 123.5 [56] 171/2 [445] 1617/64 [413] 1613/64 [412]060 0 0 0 1 [25] 2 [51] 0 128 [58] 171/2 [445] 1617/64 [413] 1613/64 [412]070 0 0 0 1 [25] 2 [51] 0 132 [60] 171/2 [445] 1617/64 [413] 1613/64 [412]085 0 0 0 1 [25] 2 [51] 0 147.5 [67] 21 [533] 1949/64 [502] 1945/64 [500]100 0 0 0 1 [25] 2 [51] 0 152 [69] 21 [533] 1949/64 [502] 1945/64 [500]115 0 0 0 1 [25] 2 [51] 0 165 [75] 241/2 [662] 2317/64 [591] 2313/64 [589]

UNIT DIMENSIONS(CLEARANCE TO COMBUSTIBLES)

UNIT DIMENSIONS(CLEARANCE TO COMBUSTIBLES)

*A service clearance of at least 24" is recommended in front of all furnaces [ ] Designates Metric ConversionsSupply and return depicted as upflow configuration.Flange configuration will vary depending on installation orientation.

Page 7: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

7www.SureComfort.com

FURN

ACE

MOD

EL

BLOW

ERSI

ZE[m

m]

MOT

ORH.

P.[W

]

MOT

ORTA

P

MOT

ORLE

AD W

IRE

COLO

RSP

EED

CFM

[L/

s] A

IR D

ELIV

ERY

EXTE

RNAL

STA

TIC

PRES

SURE

INCH

ES W

ATER

COL

UMN

[kPa

]0.

1 [.

02]

0.2

[.05

]0.

3 [.

07]

0.4

[.10

]0.

5 [.

12]

0.6

[.15

]0.

7 [.

17]

0.8

[.19

]0.

9 [.

22]

(-)9

5T(-

)04

0131

7MSA

11 x

7[2

79 x

178

]1/

2[3

73]

1Re

dLo

w87

4 [4

13]

820

[387

]76

5 [3

61]

710

[335

]65

8 [3

11]

575

[271

]52

3 [2

47]

482

[228

]44

8 [2

11]

2Ye

llow

Med

ium

Low

*10

29 [4

86]

982

[463

]93

0 [4

39]

881

[416

]83

3 [3

93]

780

[368

]71

6 [3

38]

665

[314

]62

1 [2

93]

3Pu

rple

Med

ium

1098

[518

]10

55 [4

98]

1008

[476

]96

2 [4

54]

920

[434

]87

0 [4

11]

822

[388

]75

5 [3

56]

705

[332

]

4Bl

ueM

ediu

m H

igh*

*12

53.6

[592

]12

09.1

[571

]11

64.4

[550

]11

28.1

[532

]10

82.2

[511

]10

43.7

[493

]10

00 [4

72]

960

[453

]90

7.2

[428

]

5Bl

ack

High

1380

.6 [6

52]

1345

.5 [6

35]

1313

.1 [6

20]

1276

[602

]12

39.2

[585

]12

02.3

[567

]11

66 [5

50]

1132

.7 [5

35]

1098

.9 [5

19]

(-)9

5T(-

) 06

0131

7MSA

11 x

8[2

79 x

203

]1/

2[3

73]

1Re

dLo

w81

8 [3

86]

766

[362

]72

0 [3

40]

668

[315

]59

4 [2

80]

548

[259

]49

4 [2

33]

444

[210

]41

6 [1

96]

2Ye

llow

Med

ium

Low

*96

8 [4

57]

913

[431

]88

5 [4

18]

841

[397

]79

6 [3

76]

739

[349

]68

5 [3

23]

641

[303

]59

6 [2

81]

3Pu

rple

Med

ium

1018

[480

]98

1 [4

63]

931

[439

]90

3 [4

26]

860

[406

]81

5 [3

85]

756

[357

]70

3 [3

32]

656

[310

]

4Bl

ueM

ediu

m H

igh*

*11

73 [5

54]

1142

[539

]11

08 [5

23]

1059

[500

]10

25 [4

84]

989

[467

]95

1 [4

49]

912

[430

]85

5 [4

04]

5Bl

ack

High

1338

[631

]13

27 [6

26]

1288

[608

]12

45 [5

88]

1227

[579

]11

93 [5

63]

1165

[550

]11

34 [5

35]

1099

[519

]

(-)9

5T(-

)07

0131

7MSA

11 x

8[2

79 x

203

]1/

2[3

73]

1Re

dLo

w94

7 [4

47]

908

[429

]87

1 [4

11]

834

[394

]79

6 [3

76]

755

[356

]71

6 [3

38]

681

[321

]65

6 [3

10]

2Ye

llow

Med

ium

Low

1044

[493

]99

7 [4

71]

968

[457

]93

4 [4

41]

902

[426

]86

2 [4

07]

828

[391

]79

5 [3

75]

765

[361

]

3Pu

rple

Med

ium

**11

48 [5

42]

1113

[525

]10

92 [5

15]

1056

[498

]10

29 [4

86]

995

[470

]96

2 [4

54]

928

[438

]89

5 [4

22]

4Bl

ueM

ediu

m H

igh*

*12

13 [5

72]

1180

[557

]11

55 [5

45]

1126

[531

]10

96 [5

17]

1062

[501

]10

32 [4

87]

993

[469

]96

9 [4

57]

5Bl

ack

High

1324

[625

]12

83 [6

06]

1254

[592

]12

21 [5

76]

1198

[565

]11

69 [5

52]

1141

[538

]11

07 [5

22]

1080

[510

]

(-)9

5T(-

)08

5152

1MSA

11 x

10

[279

x 2

54]

1[7

46]

1Re

dLo

w14

06 [6

64]

1355

[640

]13

00 [6

14]

1230

[581

]11

75 [5

55]

1111

[524

]10

59 [5

00]

1006

[475

]94

1 [4

44]

2Ye

llow

Med

ium

Low

*16

56 [7

82]

1621

[765

]15

74 [7

43]

1533

[723

]14

85 [7

01]

1434

[677

]13

75 [6

49]

1328

[627

]12

81 [6

05]

3Pu

rple

Med

ium

1692

[799

]16

53 [7

80]

1606

[758

]15

57 [7

35]

1508

[712

]14

59 [6

89]

1409

[665

]13

63 [6

43]

1312

[619

]

4Bl

ueM

ediu

m H

igh*

*18

81 [8

88]

1831

[864

]18

04 [8

51]

1757

[829

]17

13 [8

08]

1668

[787

]16

28 [7

68]

1568

[740

]15

28 [7

21]

5Bl

ack

High

1978

[934

]19

42 [9

17]

1906

[900

]18

62 [8

79]

1833

[865

]17

93 [8

46]

1751

[826

]17

02 [8

03]

1652

[780

]

(-)9

5T(-

)10

0152

1MSA

11 x

10

[279

x 2

54]

1[7

46]

1Re

dLo

w16

37 [7

73]

1593

[752

]15

45 [7

29]

1494

[705

]14

41 [6

80]

1382

[652

]13

29 [6

27]

1274

[601

]12

36 [5

83]

2Ye

llow

Med

ium

Low

*17

45 [8

24]

1697

[801

]16

51 [7

79]

1600

[755

]15

60 [7

36]

1500

[708

]14

43 [6

81]

1394

[658

]13

42 [6

33]

3Pu

rple

Med

ium

1766

[833

]17

23 [8

13]

1686

[796

]16

33 [7

71]

1585

[748

]15

37 [7

25]

1482

[699

]14

28 [6

74]

1380

[651

]

4Bl

ueM

ediu

m H

igh*

*19

67 [9

28]

1929

[910

]18

95 [8

94]

1852

[874

]18

05 [8

52]

1754

[828

]17

08 [8

06]

1668

[787

]16

12 [7

61]

5Bl

ack

High

2137

[100

9]21

02 [9

92]

2062

[973

]20

20 [9

53]

1975

[932

]19

46 [9

18]

1908

[900

]18

17 [8

58]

1685

[795

]

(-)9

5T(-

)11

5152

4MSA

11 x

11

[279

x 2

79]

1[7

46]

1Re

dLo

w14

76 [6

97]

1432

[676

]14

06 [6

64]

1332

[629

]12

91 [6

09]

1247

[589

]12

07 [5

70]

1163

[549

]11

17 [5

27]

2Ye

llow

Med

ium

Low

*16

15 [7

62]

1568

[740

]15

24 [7

19]

1487

[702

]14

52 [6

85]

1401

[661

]13

56 [6

40]

1325

[625

]12

78 [6

03]

3Pu

rple

Med

ium

**17

09 [8

07]

1674

[790

]16

33 [7

71]

1591

[751

]15

51 [7

32]

1519

[717

]14

77 [6

97]

1436

[678

]13

97 [6

59]

4Bl

ueM

ediu

m H

igh

1772

[836

]17

46 [8

24]

1706

[805

]16

67 [7

87]

1627

[768

]15

93 [7

52]

1553

[733

]15

21 [7

18]

1482

[699

]

5Bl

ack

High

1887

[891

]18

52 [8

74]

1828

[863

]17

84 [8

42]

1748

[825

]17

13 [8

08]

1678

[792

]16

48 [7

78]

1619

[764

]

*Low

Sta

tic H

eatin

g Sp

eed

**Hi

gh S

tatic

Hea

ting

Spee

dSh

aded

cel

ls in

dica

te s

tatic

pre

ssur

es a

t whi

ch th

at m

otor

tap

can

be u

sed

for h

eatin

g sp

eed.

Ins

talle

r mus

t ver

ify s

tatic

pre

ssur

e. I

f sta

tic p

ress

ure

is n

ot w

ithin

the

limits

not

ed h

ere,

the

high

er h

eatin

g sp

eed

tap

MUS

Tbe

use

d.Do

NOT

use

the

spee

d ta

ps a

nd/o

r sta

tic p

ress

ures

whi

ch d

o no

t fal

l int

o th

e sh

aded

cel

ls o

n th

is ta

ble.

This

tabl

e is

for r

efer

ence

. Th

e te

chni

cian

/inst

alle

r mus

t ver

ify fu

rnac

e is

ope

ratin

g w

ithin

the

publ

ishe

d ris

e ra

nge

befo

re c

ompl

etin

g th

e in

stal

latio

n.

[ ]

Des

igna

tes

Met

ric

Co

nver

sio

ns.

Page 8: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

8 www.SureComfort.com

*Filter racks are shipped without filters.Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.

FILTER RACK FILTER SIZES* INCHES [mm]

MODELRXGF-CB(UPFLOW/

HORIZONTAL)

RXGF-CD(UPFLOW)

RXGF-CC(DOWNFLOW)

S95T(-)040 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

S95T(-)060 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

S95T(-)070 153/4 x 25[400 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

S95T(-)085 191/4 x 25[489 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

S95T(-)100 191/4 x 25[489 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

S95T(-)115 223/4 x 25[578 x 635]

153/4 x 25[400 x 635]

14 x 20[356 x 508]

FOR HIGH ALTITUDES:NOTE: For Canadian installations only, an optional derate (manifold

gas pressure reduction) method may be used to adjust thefurnace for altitude. See Installation Instructions for moreinformation. This optional method may NOT be used for U.S.installations. See installation instructions as appropriate orificechange is required.

L.P. CONVERSION KIT: RXGJ-FP33

CONDENSATE PUMP KIT: PROSTOCK & 1PCB151TUL

DOWNFLOW/HORIZONTAL CONVERSION KIT: RXGY-CK

DOWNFLOW/HORIZONTAL LEFT ZERO CLEARANCE CONVERSION KIT: RXGY-ZK

COMBUSTIBLE FLOOR BASE: RXGC-B17RXGC-B21RXGC-B24

[ ] Designates Metric Conversions

INDOOR COIL CASINGSMODEL

NUMBER

RXBC-D17A1RXBC-D21A1RXBC-D21B1RXBC-D24A1

VENT TERMINATION KITS: =RXGY-E02: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US Only)

RXGY-E02A: Vertical/Horizontal Concentric Vent Termination Kit 2" Pipe (US & Canadian)

RXGY-E03: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US Only)

RXGY-E03A: Vertical/Horizontal Concentric Vent Termination Kit 3" Pipe (US & Canadian)

RXGY-G02: Direct Vent Furnace Side Wall Vent 2" or 3" (US Only)

RXGY-D05: Combustion Air Drain Kit 2"

RXGY-D06: Combustion Air Drain Kit 3"

NEUTRALIZER KIT: RXGY-A01 (Replacement Cartridge 54-22120-01)

EXTERNAL BOTTOM FILTER (UPFLOW/HORIZONTAL) RACK:RXGF-CB

EXTERNAL SIDE (UPFLOW) FILTER RACK: RXGF-CD

EXTERNAL (DOWNFLOW) FILTER RACK: RXGF-CC

Page 9: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

9www.SureComfort.com

GENERAL TERMS OF LIMITED WARRANTY*Sure Comfort® will furnish a replacement for any part of thisproduct which fails in normal use and service within theapplicable period stated, in accordance with the terms ofthe limited warranty.*For complete details of the Limited and Conditional Warranties, includingapplicable terms and conditions, contact your local contractor or theManufacturer for a copy of the product warranty certificate.

Conditional Parts(Registration Required) ...............................Ten (10) Years

Heat Exchanger .........................................Limited Lifetime

Page 10: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

10 www.SureComfort.com

Page 11: Sure Comfort Multi-Position Gas Furnaces

Sure Comfort® S95T Multi-Position Gas Furnaces

11www.SureComfort.com

Page 12: Sure Comfort Multi-Position Gas Furnaces

8/16 QG FORM NO. GSC-538

Before proceeding with installation, referto installation instructions packagedwith each model, as well as complyingwith all Federal, State, Provincial, andLocal codes, regulations, and practices.

Sure Comfort®

P.O. Box 17010, Fort Smith, AR 72917