SURESILLWATER MANAGEMENT GUIDE FOR WINDOWS AND DOORS *1 © Copyright 2004 2010-2016 SureSill, Ltd. All rights reserved. HEADFLASHASSEMBLY Measure the exterior width of the window/door, including any brick mold, and cut the DrainShield TM to that measurement. Check fit with end caps before gluing. Remove any labels from contact surfaces. Apply Wet-R-Dry TM PVC cement to contact surfaces on both End Caps and DrainShield TM (shaded area). Slide End Caps fully in place. Wipe excess PVC cement. Hold glued parts for 1 min for PVC cement to dry. Check the fit with end caps before gluing them. See Sill Pan Assembly DETAIL on page 3. Weep Holes SureSill TM Sloped Sill Pan™ Channel Plate End Cap End Cap THE SURE LEVEL OF PROTECTION SLOPED SILL PANASSEMBLY Apply Wet-R-Dry TM PVC cement to contact surfaces on both End Caps and Channel Plate (shaded area). Slide End Caps fully in place. Wipe off excess PVC cement. Page 1 of 3 SAF Henkel/OSI BUTYLFLASH; DuPont™ FlexWrap™, DuPont™ StraightFlash™, DuPont™ StraighhtFlash™ VF SEALANT Henkel/OSI® QUAD®MAX™; LOW EXPANSION FOAM QUAD®FOAM by Henkel/OSI® RECOMMENDED PRODUCTS

Upload: duongkhanh

Post on 08-Sep-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

SURESILL™ WATER MANAGEMENT GUIDE

FOR WINDOWS AND DOORS*1

© Copyright 2004 – 2010-2016 SureSill, Ltd. All rights reserved.

STEP 4

Apply TM sealant at jambs and head.

STEP 7

Install waterproofing

HEADFLASH™ ASSEMBLY Measure the exterior width of the window/door, including any brick

mold, and cut the DrainShieldTM to that measurement. Check fit with end caps before gluing. Remove any labels from contact surfaces.

Apply Wet-R-DryTM PVC cement to contact surfaces on both End Caps and

DrainShieldTM (shaded area).

Slide End Caps fully in place. Wipe excess PVC cement. Hold glued parts for 1 min for PVC cement

to dry.

Cut the channel plate ¼” smaller than the rough opening. Check the fit with end caps before gluing them. See Sill Pan Assembly DETAIL on page 3.

Weep Holes

SureSillTM Sloped Sill Pan™

Channel Plate

End Cap End Cap

THE SURE LEVEL OF

PROTECTION

SLOPED SILL PAN™ ASSEMBLY

Apply Wet-R-DryTM PVC cement to contact surfaces on both End Caps and Channel Plate

(shaded area).

Slide End Caps fully in place. Wipe off excess

PVC cement.

Page 1 of 3

SAF – Henkel/OSI BUTYLFLASH; DuPont™ FlexWrap™, DuPont™ StraightFlash™, DuPont™ StraighhtFlash™ VF

SEALANT – Henkel/OSI® QUAD®MAX™; LOW EXPANSION FOAM –QUAD®FOAM by Henkel/OSI®

RECOMMENDED

PRODUCTS

STEP 2

Slots for Fasteners

Install 12” wide water-proofing (SAF or similar) 6” above plate and over any sub-floor area.

© Copyright 2004 – 2016 SureSill, Ltd. All rights reserved.

Install assembled SureSillTM Sloped Sill Pan™ plumb and leveled across entire rough opening, and secure to rough opening by fasteners in slots provided.

STEP 5

Install WRB in shingle fashion, including over jamb flashing and head flashing. ALLOW FREE DRAINAGE FOR SURESILL™

SLOPED SILL PAN™ AND HEADFLASH™ DURING AND AFTER

CONSTRUCTION. PAINTING IS RECOMMENDED FOR THE SURFACES

EXPOSED TO EXTERIOR. APPLY FOAM TO THE INTERIOR SIDE TO SEAL

THE GAP BETWEEN THE FRAME/JAMB AND THE ROUGH OPENING ON

THREE SIDES (TWO VERTICAL AND ON TOP).

STEP 1 Install Drainage Skirt 6” above plate over any sub-floor area. See

Sealing the Sill Pan STEP 1 DETAIL

Apply sealant on concrete, sub- floor or base plate and 6” up

the sides.

STEP 4

Install window or door per OEM instructions. See STEP 4 DETAIL Install additional SAF at jambs (brick mold). Apply 3/8” bead of sealant behind

the HeadFlashTM. Install HeadFlashTM head flashing. Apply SAF over the HeadFlashTM

STEP 3

Use self adhering flashing (SAF) on rough jamb, over SureSillTM End Caps. Apply adhesive sealant to jambs and

head.

Adhesive Sealant

(over SAF and head)

IMPORTANT: Seal the 1/8” gap behind window or door threshold with sealant and tool it flat. Back of the door/window casing should be grooved to

accommodate for the sill pan.

THE SURE LEVEL OF

PROTECTION

Page 2 of 3

SureSill™ Water Management Guide*1

NOTE: SURESILL™ SLOPED SILL

PAN™ AND SURESILL™

HEADFLASH™ SHOULD BE

INSTALLED AT THE SAME TIME

A WINDOW OR DOOR IS BEING

INSTALLED.

STEP 4 DETAIL

To prevent air and water infiltration seal between the back of the sill pan and the back of the jamb/sill and between the jamb and the rough opening.

Installation Details

SureSill™ Water Management Guide*1

SureSill, HeadFlash and HeadFlash-Flex are Patent Pending Technologies made only by Suresill, Ltd. SureSillTM, HeadFlashTM, HeadFlash-FlexTM, Wet-R-DryTM, and DrainShieldTM, are the exclusive trademarks of SureSill, Ltd.

© Copyright 2004 – 2016 SureSill, Ltd. All rights reserved. WMG H 105 20071201R Page 3 of 3 .

STEP 4

Apply SSSuuurrreeeSSSiiillllll BBBooonnnddd TM 222000000000 sealant at jambs and head.

STEP 7

Install waterproofing in shingle-fashion, including over jamb flashing and head flashing. Provide free drainage

for SureSill.

NOTE *1: Recommended rough opening size is ¾” larger then the window/door frame. This is a generic Water Management Guide and it is not intended to alter Window and Door Manufacturer’s (OEM) recommendations. Please notify SureSill prior to installation if any steps are contradictory to OEM’s installation instructions. SureSill recommends that OEM approves the rough opening size, the installation method and all products

used prior to installation.

SEALING AGAINST AIR AND WATER INFILTRATION

FRONT SIDE BACK SIDE

SILL PAN ASSEMBLY

DETAIL REMOVE LABELS FROM CONTACT SURFACES.

AS PART OF THE SILL PAN ASSEMBLY APPLY SEALANT

ALONG THE EDGE OF END CAP. WITHOUT PROPER

ASSEMBLY THE SILL PAN WILL LEAK. SURESILL™ IFS™

SHOULD BE INSTALLED AT THE SAME TIME A WINDOW OR

DOOR IS BEING INSTALLED.

1. APPLY CONTINUOUS BEAD OF

SEALANT BETWEEN THE BACK

EDGE OF THE SILL PAN AND THE

SILL OR JAMB, AND BETWEEN THE

BACK EDGE OF END CAPS AND

THE JAMB TO PREVENT ANY AIR

AND WATER INFILTRATION.

2. APPLY CONTINUOUS LOW

EXPANSION FOAM OR SEALANT

BETWEEN THE JAMB AND THE

ROUGH OPENING ON THREE SIDES

(TWO VERTICAL SIDES AND ON

TOP) TO PREVENT AIR AND WATER

INFILTRATION.

NOTE *2 : THE BEAD OF SEALANT SHOULD BE CONTINUOUS AND TOOLED FLAT. SOME SEALANTS MAY HAVE ADVERSE REACTION WITH CERTAIN SELF ADHERING FLASHING PRODUCTS. PLEASE VERIFY COMPATIBILITY WITH THE MANUFACTURER. THE FOAM AND THE SEALANT SHOULD OVERLAP AND HAVE AN AIR-TIGHT JOINT.

DOOR OR

WINDOW

ROUGH

OPENING

Sealing the Sill Pan to WRB

STEP 1 DETAIL - Seal the front lip of the Sill Pan to WRB or to

Drainage Skirt. Seal between the sill pan and the rough opening by applying sealant on the bottom of the rough opening and 6” on the sides as indicated. This should provide a barrier against both moisture and air infiltration between the sill pan and the rough opening. Use 5/8” thick bead of sealant.

6”

SureSill, HeadFlash and HeadFlash-Flex are Patented and Patent Pending Technologies made only by Suresill, Ltd. SureSill

TM, HeadFlash

TM, HeadFlash-Flex

TM, Wet-R-Dry

TM, DrainShield

TM, and SideFlash

TM are the exclusive

trademarks 1

of SureSill, Ltd. © Copyright SureSill, Ltd. 2004 - 2016. All rights reserved. 20130417

EXTERIOR DOOR SOLUTIONS EXTERIOR DOOR DRAIN DETAIL

1. STEP DOWN LANDING – RECOMMENDED

SURESILLTM

Sloped Sill Pan™

Finish Floor

Door

Door Sill

Sealant Joint

Sloped

2” Minimum

CONCRETE OR SUBFLOOR

Masonry Veneer

DEDICATED DRAIANGE PATH - FOR PROPER DRAINAGE BEHIND MASONRY USE RAIN SCREEN SUCH AS ENKADRAIN 9010® BY COLBOND, Inc. APPLY 2” WIDE STRIPS 12”O.C.

Mortar Joint Landing Tiles or other finish

surface

Fig. 1 EXTERIOR DOOR WITH STEP-DOWN LANDING

With Masonry Veneer - Door Drain Detail

Step Down Landing should be minimum 2”.

Install SureSill™ System per SureSill Water Management Guide

Instead of Masonry Veneer, other exterior cladding can be installed, such as Stucco, Siding, etc., however, a Dedicated Drainage Path proper drainage should always be installed.

Install SureSill™ System per SureSill Water Management Guide

SureSill, HeadFlash and HeadFlash-Flex are Patented and Patent Pending Technologies made only by Suresill, Ltd. SureSill

TM, HeadFlash

TM, HeadFlash-Flex

TM, Wet-R-Dry

TM, DrainShield

TM, and SideFlash

TM are the exclusive

trademarks 2

of SureSill, Ltd. © Copyright SureSill, Ltd. 2004 - 2016. All rights reserved. 20130417

2. CONTINUOUS SLAB (ON-GRADE) EXTERIOR DOOR DRAIN DETAIL

INCLUDING ADA DOORS

Landing

Fig. 2 CONTINOUS SLAB EXTERIOR DOOR DRAIN DETAIL

Deck Drain should be installed to evacuate the water with an open end away from the building. Exterior Surface should slope away from the building.

Install SureSill™ System per SureSill Water Management Guide

Recommended products for Deck Drain: Super Drain by Stegmeier Corporation http://www.stegmeier.com/index.php?option=com_content&view=article&id=83&Itemid=111

Exterior

Surface

- Sloped