THIS IS ONE OF THE DRAWINGS REFERED TO IN THE CONTRACT : OWNER ................................DATE............................... OWNER ...............................DATE................................ BUILDER ...............................DATE................................ DATE: 20/08/2020 SCALE: 1:200 JOB N°: REVISION N°: 01 SHEET N°: of 09 1904R11 EXISTING SITE PLAN 01 PREMIUM VENADO VARIATIONS: DATE: REV: DESCRIPTION: INT: /C1S/ /C2S/ /BS/ /C1D/ /C2D/ /BD/ '1' CONTRACT (SILVER PLANS) TD 29.07.20 '2' '3' '4' '5' '6' '7' '8' '9' '10' . Due to lack of survey marks/pegs, all building offset dimensions & features are approximate only and positioned from existing pegs/fences and walls which may not be on the correct alignment and are to be verified when repegged. Any design that involves additions to any structures shown or portion of structures remaining after any demolition has taken place requires DISCLAIMER: boundaries to be repegged and exact offsets provided to your designer/architect before any plans are produced and before any work is started on site. OLD AREA WARNING: Check developer/strata company regarding possible future/existing internal service run ins, positions & details. Check for possible private sewer lines & position & details of connection to strata lot. Beware possible building restrictions on strata lot by management statement or by-laws. If strata boundaries not defined on plan only parent lot may be re-pegged and line pegs placed. Scale 1:200 0 2 4 6 8 W S E N SURVEY STRATA LOT 1 SOIL DESCRIPTION Sand Refer to Survey 453072 08 May 19 T.Currey Builder : 101 Residential Pty Ltd CLIENT : WEINBAUER SURVEY STRATA LOT 1 #28A Dilkara Way, City Beach Survey Strata Plan2528 Original Lot 38 on Plan 10632 SURVEY STRATA LOT 2 78°41'40" 12.59 101°16'47" 38 . 98 78°43'13" 12.57 101°18'20" 3.52 135°0'0" 30.66 90°0'0" 23.39 135°0'0" 1.02 38.98 (16.09) (13.61) 17 . 12 17 . 09 17.09 17 . 03 17 . 03 17 . 22 19.08 18.59 17.11 17.10 18.41 17.08 17 . 07 17.27 17.03 17 . 02 17 . 01 17.03 17.02 17.06 17.03 17.04 17.04 17.05 17.04 16.98 15.93 16 . 99 16.91 16.93 16.97 17.88 16.91 16.93 16 . 95 16 . 94 16.95 16 . 96 16 . 96 16.97 17 . 07 17.05 17.07 17.04 17.05 17.07 17.01 17.11 17 . 07 17.04 17.07 17.09 16.99 17.00 16.98 16.95 16.95 15.40 15.54 15.89 16.41 17.83 16.89 16.88 17.75 17.80 17.77 17.78 17.19 17.04 17.13 17.05 17.18 17.17 17.02 17.10 17.20 17.49 17.55 17.43 17.68 17.63 17.10 2.45 2.45 2.4 2.4 7.48 7 6.52 101°18'20" 101°18'20" 90° 90° 90° VEHICLE ACCESS EASEMENT Bitumen Dilkara Way Nil Nil Nil Ref Nail At Base Of Kerb A.H.D. level 17.54m (Established from S.S.M. WEMBLEY 24A using data supplied by the Geodetic Section of Landgate) Non-Mount Non-Mount Light Pole Bitumen Crossover Concrete Crossover PEG FND T PEG GONE PEG GONE PEG GONE PEG GONE NAIL & PLATE FOUND IN BITUMEN N Concrete Concrete Lawn Brick Wall Brick Wall Brick & Galv Garage -Under Const. Approx F/L 17.05 Poss Parapet Wall Timber & Galv Carport Over Concrete Approx F/L 15.51 Ground Floor First Floor 2-Storey Brick & Tile On Slab (#30) P . A . W Brick Letterbox Low Brick Wall Porch UMR Over Concrete TW [ ] 17.05 17.10 17.11 17.14 Approx F/L At Door (Timber) 17.18 Approx F/L At Door (Brick) 16.99 Carport UMR Over Concrete Meter Box (Elec.) M Galv Patio Over Brick Brick Lawn Garden Galv Shed Door Galv Patio Over Concrete 17 . 23 17 . 18 17 . 22 19.03 TW [ ] TF [ ] 17 . 37 17.17 17.07 TF [ ] Low L'stone Wall Approx F/L At Door (Timber) 17.18 Brick & Slabs 16.56 TF [ ] Gate Existing Fibro (Capped, Fair Cond.) RECREATION RESERVE Slabs Ocean Views Brick & Tile On Slab (#28A) Door 2-Storey Brick & Tile On Slab -Under Const. (#28) Brick Wall 17.03 17.88 TW [ ] TW [ ] 16.91 16.93 16.91 17.03 17 . 14 Garden Garden Low L'stone Wall (Meas Abt. 12.57) (Meas Abt. 3.52) (Meas Abt. 1.02) (Meas Abt. 23.39) Sewer M/H (17.47) Unable to Calculate Sewer Junction Depth Due to Lack of Information on Water Corporation E-Plan. Verify Junction Invert, Depth & Details With Water Corporation. BUILDER and PLUMBER check GRADE NOTE: Sewer Junction Up: 1.7 Inv: 13.6 NOTE: UP NOTE: Approx. Sewer Clearance Line (This line is NOT an easement) Setbacks MUST be confirmed by Water Corp. before any design work is undertaken. This line is NOT definitive. 0.004 m SSL 2 MISCLOSE 0.004 m SSL 1 MISCLOSE 1:200 c J/N: DATE: DRAWN: SCALE: Licensed Surveyors 87-89 Guthrie Street, Osborne Park, Western Australia Telephone: (08) 9446 7361 Facsimile: (08) 9445 2998 Email : [email protected] Website: www.cottage.com.au Lot boundaries drawn on survey are based on landgate plan only. Survey does not include title search and as such may not show easements or other interests not shown on plan. Title should be checked to verify all lot details and for any easements or other interests which may affect building on the property. Survey does not include verification of cadastral boundaries. All features and levels shown are based on orientation to existing pegs and fences only which may not be on correct cadastral alignment. Any designs based or dependent on the location of existing features should have those features' location verified in relation to the true boundary. Survey shows visible features only and will not show locations of underground pipes or conduits for internal or mains services. Verification of the location of all internal and mains services should be confirmed prior to finalisation of any design work. Cottage & Engineering surveys accept no responsibility for any physical on site changes to the parcel or portion of the parcel of land shown on this survey including any adjoining neighbours levels and features that have occurred after the date on this survey. All Sewer details plotted from information supplied by Water Corporation. DISCLAIMER: DISCLAIMER: DISCLAIMER: DISCLAIMER: SEC Dome Power Pole Phone Pits LEGEND T C TP 10.00 TW TR TF [ [ [ [ 10.00 10.00 10.00 ] ] ] ] Top Pillar/Post Top Wall Top Retaining Top Fence W Water Conn. Out Levels Unob. Out Levels Unob. Sewer I.O. Positions of all sewer manholes, junctions and sewer lines are approximate only due to lack of information. Please confirm all positions with Water Corp. NOTE:

Upload: others

Post on 29-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:200

    JOB N°:REVISION N°:

    01SHEET N°:

    of 09

    1904R11

    EXISTING SITE PLAN

    01

    PREMIUM VENADO VARIATIONS: DATE:REV: DESCRIPTION: INT:

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    .

    Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and walls whichmay not be on the correct alignment and are to beverified when repegged. Any design that involvesadditions to any structures shown or portion of structuresremaining after any demolition has taken place requires

    DISCLAIMER:

    boundaries to be repegged and exact offsets providedto your designer/architect before any plans are producedand before any work is started on site.

    OLDAREA

    WARNING:Check developer/strata company regarding possiblefuture/existing internal service run ins, positions &details. Check for possible private sewer lines &position & details of connection to strata lot. Bewarepossible building restrictions on strata lot bymanagement statement or by-laws. If strataboundaries not defined on plan only parent lot maybe re-pegged and line pegs placed.

    Scale 1:2000 2 4 6 8

    W

    S

    E

    N

    SURVEYSTRATA

    LOT 1

    SOIL DESCRIPTIONSandRefer to Survey

    453072 08 May 19 T.Currey

    Builder : 101 Residential Pty LtdCLIENT : WEINBAUERSURVEY STRATA LOT 1 #28A Dilkara Way, City Beach

    Survey Strata Plan2528 Original Lot 38 on Plan 10632

    SURVEYSTRATA

    LOT 2

    7 8 ° 4 1 '4 0 "12.59

    1 0 1° 1 6

    '4 7"

    38.98

    7 8 ° 4 3 '1 3 "

    12.571 0 1

    ° 1 8'2 0

    "3.521 3 5 ° 0 '0 "

    30.66

    9 0 ° 0 '0 "

    23.39

    135°0'0"

    1.02

    38.98

    (16.09)

    (13.61)

    17.1

    217

    .09

    1 7 .0 917

    .03

    17.0

    317

    .22

    1 9 .0 8

    18 .59

    17 .11

    17 .1018 .41

    17.0

    817

    .071

    7 .27

    17.0

    3

    17.0

    217

    .01

    1 7 .0 317

    .02

    1 7 .06

    1 7 .0 3

    17.041 7 .0 4

    1 7 .0 5

    1 7 .0 4

    1 6 .9 8

    15 .93

    16.9

    91 6 .91

    16.93

    16 .97

    17 .88

    16 .9116 .93

    16.9

    516

    .94

    1 6 .95

    16.9

    616

    .96

    1 6 .97

    17.0

    7

    1 7 .0 51 7 .0 7

    17 .04

    1 7 .0 517.0717 .01

    1 7 .1 1

    17.0

    7

    1 7 .0 4

    17 .0717 .09

    16 .9917 .00

    16 .9816.95

    1 6 .9 5

    15 .40

    15 .54

    15 .89

    16 .41

    17 .83 16 .89

    16.8

    8

    1 7 .7 5

    1 7 .8 0

    17.7

    7

    17.7

    8

    17.1

    9

    1 7 .0 417

    .13

    17.05

    17 .1817 .17

    17.0

    2

    17.1

    0

    17.2

    0

    1 7 .49 1 7 .5 51 7 .4 3

    17.6

    8

    1 7 .6 317.

    10

    2.452.45

    2.4 2.4

    7.48

    7

    6.52

    101°18

    '20"

    101°18

    '20"

    90° 90° 90°

    VEHICLEACCESSEASEMENT

    BitumenDilkara Way

    Nil

    NilNil

    Ref Nail At Base Of Kerb A.H.D. level 17.54m(Established from S.S.M.WEMBLEY 24A using data suppliedby the Geodetic Section of Landgate)

    Non-Mount

    Non-Mount

    Light Pole

    BitumenCrossover

    ConcreteCrossover

    PEGFNDT

    PEGGONE

    PEGGONE

    PEGGONE

    PEGGONE

    NAIL & PLATEFOUND IN BITUMENN

    ConcreteConc

    rete

    Lawn

    Brick Wall

    BrickWall

    Brick &Galv Garage-Under Const.

    Approx F/L 17.05

    Poss

    Par

    apet

    Wall

    Timber & GalvCarport Over

    Concrete

    ApproxF/L 15.51

    GroundFloor

    FirstFloor

    2-Storey Brick& Tile On Slab (#30)

    P . A . W

    BrickLetterbox

    LowBrickWall

    Porch UMROver Concrete

    TW[

    ]

    17 .05

    1 7 .10

    17 .11

    1 7 .14

    Approx F/L AtDoor (Timber) 17.18

    Approx F/L AtDoor (Brick) 16.99

    CarportUMR OverConcreteMeter Box

    (Elec.) M

    Galv PatioOver Brick

    Brick

    Lawn

    Garden

    GalvShed

    Door

    GalvPatioOver

    Concrete

    17.2

    3

    17.1

    817

    .22

    1 9 .0 3TW[ ]

    TF[ ]17.3

    7

    1 7 .1 7

    17 .07

    TF[

    ]Low L'stone Wall

    Approx F/L AtDoor (Timber) 17.18

    Brick& Slabs

    16 .56

    TF[

    ]

    Gate

    ExistingFibro (Capped,

    Fair Cond.)

    RECREATIONRESERVE

    Slabs

    OceanViews

    Brick & TileOn Slab (#28A)

    Door

    2-Storey Brick& Tile On Slab-Under Const.

    (#28)

    Brick Wall

    17 .03

    17 .88

    TW[

    ]

    TW[

    ]16 .91

    16.93

    16 .91

    17 .03

    17.1

    4

    Garden

    Garden

    LowL'stone

    Wall

    (Meas Abt. 12.57)

    (Meas Abt. 3.52)

    (Meas Abt. 1.02)

    (Meas A

    bt. 23.39

    )

    Sewer M/H(17.47)

    Unable to CalculateSewer Junction Depth Due to Lack ofInformation on Water CorporationE-Plan. Verify Junction Invert, Depth& Details With Water Corporation.BUILDER and PLUMBER check GRADE

    NOTE:

    Sewer JunctionUp: 1.7Inv: 13.6NOTE: UP

    NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.

    0.004 mSSL 2 MISCLOSE

    0.004 mSSL 1 MISCLOSE

    1:200cJ/N: DATE: DRAWN:SCALE:

    Licensed Surveyors

    87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998

    Email : [email protected] Website: www.cottage.com.au

    Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.

    Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.

    Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.

    Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    SEC DomePower PolePhone Pits

    LEGE

    ND T CTP 10.00TWTRTF

    [[[[

    10.0010.0010.00

    ]]]]

    Top Pillar/PostTop WallTop RetainingTop Fence

    W Water Conn.

    Out L

    evels

    Uno

    b.Ou

    t Lev

    els U

    nob.

    Sewe

    r I.O

    .

    Positions of all sewer manholes, junctions and sewerlines are approximate only due to lack of information.Please confirm all positions with Water Corp.

    NOTE:

  • THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:200, 1:100

    JOB N°:REVISION N°:

    02SHEET N°:

    of 09

    1904R11

    SITE DEMOLITION PLAN

    01

    PREMIUM VENADO VARIATIONS: DATE:REV: DESCRIPTION: INT:

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    .

    Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and walls whichmay not be on the correct alignment and are to beverified when repegged. Any design that involvesadditions to any structures shown or portion of structuresremaining after any demolition has taken place requires

    DISCLAIMER:

    boundaries to be repegged and exact offsets providedto your designer/architect before any plans are producedand before any work is started on site.

    OLDAREA

    WARNING:Check developer/strata company regarding possiblefuture/existing internal service run ins, positions &details. Check for possible private sewer lines &position & details of connection to strata lot. Bewarepossible building restrictions on strata lot bymanagement statement or by-laws. If strataboundaries not defined on plan only parent lot maybe re-pegged and line pegs placed.

    Scale 1:2000 2 4 6 8

    W

    S

    E

    N

    SURVEYSTRATA

    LOT 1

    SOIL DESCRIPTIONSandRefer to Survey

    453072 08 May 19 T.Currey

    Builder : 101 Residential Pty LtdCLIENT : WEINBAUERSURVEY STRATA LOT 1 #28A Dilkara Way, City Beach

    Survey Strata Plan2528 Original Lot 38 on Plan 10632

    SURVEYSTRATA

    LOT 2

    7 8 ° 4 1 '4 0 "12.59

    1 0 1° 1 6

    '4 7"

    38.98

    7 8 ° 4 3 '1 3 "

    12.571 0 1

    ° 1 8'2 0

    "3.521 3 5 ° 0 '0 "

    30.66

    9 0 ° 0 '0 "

    23.39

    135°0'0"

    1.02

    38.98

    (16.09)

    (13.61)

    17.1

    217

    .09

    1 7 .0 917

    .03

    17.0

    317

    .22

    1 9 .0 8

    18 .59

    17 .11

    17 .1018 .41

    17.0

    817

    .071

    7 .27

    17.0

    3

    17.0

    217

    .01

    1 7 .0 317

    .02

    1 7 .06

    1 7 .0 3

    17.041 7 .0 4

    1 7 .0 5

    1 7 .0 4

    1 6 .9 8

    15 .93

    16.9

    91 6 .91

    16.93

    16 .97

    17 .88

    16 .9116 .93

    16.9

    516

    .94

    1 6 .95

    16.9

    616

    .96

    1 6 .97

    17.0

    7

    1 7 .0 51 7 .0 7

    17 .04

    1 7 .0 517.0717 .01

    1 7 .1 1

    17.0

    7

    1 7 .0 4

    17 .0717 .09

    16 .9917 .00

    16 .9816.95

    1 6 .9 5

    15 .40

    15 .54

    15 .89

    16 .41

    17 .83 16 .89

    16.8

    8

    1 7 .7 5

    1 7 .8 0

    17.7

    7

    17.7

    8

    17.1

    9

    1 7 .0 417

    .13

    17.05

    17 .1817 .17

    17.0

    2

    17.1

    0

    17.2

    0

    1 7 .49 1 7 .5 51 7 .4 3

    17.6

    8

    1 7 .6 317.

    10

    2.452.45

    2.4 2.4

    7.48

    7

    6.52

    101°18

    '20"

    101°18

    '20"

    90° 90° 90°

    VEHICLEACCESSEASEMENT

    BitumenDilkara Way

    Nil

    NilNil

    Ref Nail At Base Of Kerb A.H.D. level 17.54m(Established from S.S.M.WEMBLEY 24A using data suppliedby the Geodetic Section of Landgate)

    Non-Mount

    Non-Mount

    Light Pole

    BitumenCrossover

    ConcreteCrossover

    PEGFNDT

    PEGGONE

    PEGGONE

    PEGGONE

    PEGGONE

    NAIL & PLATEFOUND IN BITUMENN

    ConcreteConc

    rete

    Lawn

    Brick Wall

    BrickWall

    Brick &Galv Garage-Under Const.

    Approx F/L 17.05

    Poss

    Par

    apet

    Wall

    Timber & GalvCarport Over

    Concrete

    ApproxF/L 15.51

    GroundFloor

    FirstFloor

    2-Storey Brick& Tile On Slab (#30)

    P . A . W

    BrickLetterbox

    LowBrickWall

    Porch UMROver Concrete

    TW[

    ]

    17 .05

    1 7 .10

    17 .11

    1 7 .14

    Approx F/L AtDoor (Timber) 17.18

    Approx F/L AtDoor (Brick) 16.99

    CarportUMR OverConcreteMeter Box

    (Elec.) M

    Galv PatioOver Brick

    Brick

    Lawn

    Garden

    GalvShed

    Door

    GalvPatioOver

    Concrete

    17.2

    3

    17.1

    817

    .22

    1 9 .0 3TW[ ]

    TF[ ]17.3

    7

    1 7 .1 7

    17 .07

    TF[

    ]Low L'stone Wall

    Approx F/L AtDoor (Timber) 17.18

    Brick& Slabs

    16 .56

    TF[

    ]

    Gate

    ExistingFibro (Capped,

    Fair Cond.)

    RECREATIONRESERVE

    Slabs

    OceanViews

    Brick & TileOn Slab (#28A)

    Door

    2-Storey Brick& Tile On Slab-Under Const.

    (#28)

    Brick Wall

    17 .03

    17 .88

    TW[

    ]

    TW[

    ]16 .91

    16.93

    16 .91

    17 .03

    17.1

    4

    Garden

    Garden

    LowL'stone

    Wall

    (Meas Abt. 12.57)

    (Meas Abt. 3.52)

    (Meas Abt. 1.02)

    (Meas A

    bt. 23.39

    )

    Sewer M/H(17.47)

    Unable to CalculateSewer Junction Depth Due to Lack ofInformation on Water CorporationE-Plan. Verify Junction Invert, Depth& Details With Water Corporation.BUILDER and PLUMBER check GRADE

    NOTE:

    Sewer JunctionUp: 1.7Inv: 13.6NOTE: UP

    NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.

    0.004 mSSL 2 MISCLOSE

    0.004 mSSL 1 MISCLOSE

    1:200cJ/N: DATE: DRAWN:SCALE:

    Licensed Surveyors

    87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998

    Email : [email protected] Website: www.cottage.com.au

    Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.

    Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.

    Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.

    Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    SEC DomePower PolePhone Pits

    LEGE

    ND T CTP 10.00TWTRTF

    [[[[

    10.0010.0010.00

    ]]]]

    Top Pillar/PostTop WallTop RetainingTop Fence

    W Water Conn.

    Out L

    evels

    Uno

    b.Ou

    t Lev

    els U

    nob.

    Sewe

    r I.O

    .

    Positions of all sewer manholes, junctions and sewerlines are approximate only due to lack of information.Please confirm all positions with Water Corp.

    NOTE:

    NOTE:ALL EXISTING STRUCTURES, WALLS, SHED,ETC. SHOWN HATCHED TO BE REMOVEDPRIOR TO COMMENCEMENT OFCONSTRUCTION.

  • THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:200

    JOB N°:REVISION N°:

    03SHEET N°:

    of 09

    1904R11

    SITE PLAN

    01

    PREMIUM VENADO VARIATIONS: DATE:REV: DESCRIPTION: INT:

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    SITE COVERAGEZONED R20% ALLOWED 50%SITE AREA 445.45m2SITE COV. AREA 205.32m2

    OPEN SPACE =53.9%

    D.P

    INT. D.P

    INT. D.P

    D.P

    INT. D.P

    D.P

    D.P

    D.P

    D.P

    800 800 2,500 2,090 6,600 100

    800 10,350 1,640 100

    2,279

    1,253

    976

    976

    1,779

    1,600

    100

    3,900

    1,900

    700

    1,200

    4,890

    8,800

    9,100

    12,39

    05,6

    003,2

    008,6

    85

    1,243

    NO SERVICE AREA.

    PLUMB DUCT

    PLUMB DUCT

    EXTENT OF UPPERFLOOR

    .

    Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and walls whichmay not be on the correct alignment and are to beverified when repegged. Any design that involvesadditions to any structures shown or portion of structuresremaining after any demolition has taken place requires

    DISCLAIMER:

    boundaries to be repegged and exact offsets providedto your designer/architect before any plans are producedand before any work is started on site.

    OLDAREA

    WARNING:Check developer/strata company regarding possiblefuture/existing internal service run ins, positions &details. Check for possible private sewer lines &position & details of connection to strata lot. Bewarepossible building restrictions on strata lot bymanagement statement or by-laws. If strataboundaries not defined on plan only parent lot maybe re-pegged and line pegs placed.

    Scale 1:2000 2 4 6 8

    W

    S

    E

    N

    SOIL DESCRIPTIONSandRefer to Survey

    453072 08 May 19 T.Currey

    Builder : 101 Residential Pty LtdCLIENT : WEINBAUERSURVEY STRATA LOT 1 #28A Dilkara Way, City Beach

    Survey Strata Plan2528 Original Lot 38 on Plan 10632

    SURVEYSTRATA

    LOT 2

    7 8 ° 4 1 '4 0 "12.59

    1 0 1° 1 6

    '4 7"

    38.98

    7 8 ° 4 3 '1 3 "

    12.571 0 1

    ° 1 8'2 0

    "

    1 3 5 ° 0 '0 "

    30.66

    23.39

    135°0'0"

    1.02

    38.98

    (16.09)

    (13.61)

    17.1

    217

    .09

    1 7 .0 917

    .03

    17.0

    317

    .22

    1 9 .0 8

    18 .59

    17 .11

    17 .1018 .41

    17.0

    817

    .071

    7 .27

    17.0

    3

    17.0

    217

    .01

    1 7 .0 317

    .02

    1 7 .06

    1 7 .0 3

    17.041 7 .0 4

    1 7 .0 5

    1 7 .0 4

    1 6 .9 8

    15 .93

    16.9

    91 6 .91

    16.93

    16 .97

    17 .88

    16 .9116 .93

    16.9

    516

    .94

    1 6 .95

    16.9

    616

    .96

    1 6 .97

    17.0

    7

    1 7 .0 51 7 .0 7

    17 .04

    1 7 .0 517.0717 .01

    1 7 .1 1

    17.0

    7

    1 7 .0 4

    17 .0717 .09

    16 .9917 .00

    16 .9816.95

    1 6 .9 5

    15 .40

    15 .54

    15 .89

    16 .41

    17 .83 16 .89

    16.8

    8

    1 7 .7 5

    1 7 .8 0

    17.7

    7

    17.7

    8

    17.1

    9

    1 7 .0 417

    .13

    17.05

    17 .1817 .17

    17.0

    2

    17.1

    0

    17.2

    0

    1 7 .49 1 7 .5 51 7 .4 3

    17.6

    8

    1 7 .6 317.

    10

    2.452.45

    2.4 2.4

    7.486.5

    2

    101°18

    '20"

    90° 90° 90°

    VEHICLEACCESSEASEMENT

    BitumenDilkara Way

    Nil

    NilNil

    Ref Nail At Base Of Kerb A.H.D. level 17.54m(Established from S.S.M.WEMBLEY 24A using data suppliedby the Geodetic Section of Landgate)

    Non-Mount

    Non-Mount

    Light Pole

    BitumenCrossover

    ConcreteCrossover

    PEGFNDT

    PEGGONE

    PEGGONE

    PEGGONE

    PEGGONE

    NAIL & PLATEFOUND IN BITUMENN

    Concrete

    Lawn

    Brick Wall

    Brick &Galv Garage-Under Const.

    Approx F/L 17.05

    Poss

    Par

    apet

    Wall

    ApproxF/L 15.51

    GroundFloor

    FirstFloor

    2-Storey Brick& Tile On Slab (#30)

    P . A . W

    TW[

    ]

    17 .05

    1 7 .10

    17 .11

    1 7 .14

    Garden

    17.2

    3

    17.1

    817

    .22

    1 9 .0 3TW[ ]

    TF[ ]17.3

    7

    1 7 .1 7

    17 .07

    TF[

    ]16 .

    56

    TF[

    ]

    Gate

    ExistingFibro (Capped,

    Fair Cond.)

    RECREATIONRESERVE

    OceanViews

    Door

    2-Storey Brick& Tile On Slab-Under Const.

    (#28)

    Brick Wall

    17 .03

    17 .88

    TW[

    ]

    TW[

    ]16 .91

    16.93

    16 .91

    17 .03

    17.1

    4

    (Meas Abt. 12.57)

    (Meas Abt. 3.52)

    (Meas Abt. 1.02)

    (Meas A

    bt. 23.39

    )

    Sewer M/H(17.47)

    Unable to CalculateSewer Junction Depth Due to Lack ofInformation on Water CorporationE-Plan. Verify Junction Invert, Depth& Details With Water Corporation.BUILDER and PLUMBER check GRADE

    NOTE:

    Sewer JunctionUp: 1.7Inv: 13.6NOTE: UP

    NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.

    0.004 mSSL 2 MISCLOSE

    0.004 mSSL 1 MISCLOSE

    1:200cJ/N: DATE: DRAWN:SCALE:

    Licensed Surveyors

    87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998

    Email : [email protected] Website: www.cottage.com.au

    Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.

    Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.

    Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.

    Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    DISCLAIMER:

    SEC DomePower PolePhone Pits

    LEGE

    ND T CTP 10.00TWTRTF

    [[[[

    10.0010.0010.00

    ]]]]

    Top Pillar/PostTop WallTop RetainingTop Fence

    W Water Conn.

    Out L

    evels

    Uno

    b.Ou

    t Lev

    els U

    nob.

    Sewe

    r I.O

    .

    Positions of all sewer manholes, junctions and sewerlines are approximate only due to lack of information.Please confirm all positions with Water Corp.

    NOTE:

    PROPOSEDRESIDENCEFFL 17.180SPL 17.095

    PAVEDDRIVEWAY

    1m PAVEDPATH

    SETBACK

    SETBACK

    SETBACK

    SETBAC

    KSET

    BACKSE

    TBACK

    SETBAC

    K

    SETBACK

    PHYS

    ICAL

    TER

    MITE

    BAR

    RIER

    & FI

    RE S

    EPAR

    ATIO

    N RE

    Q'D

    BOUNDARY WALL w/SQUARELINE GUTTER @ 32cTO BE SETBACK 100mmFROM BOUNDARY

    COMB M/BOX(3 PHASE)

    SETBAC

    K

    INST. GASHWU

    STORMWATERPRELAY UNDERSLAB

    EXTENT OFUF CANTILEVER

    EXISTING FENCE TOBE REPLACED W/- SEMI

    PERMEABLE TO COUNCIL REQ.

    SW1.2 x 1.2

    SW1.2 x 1.2

    SW1.2 x 1.2

    Soak Well TypeNo.SW 1200x120034.1 m3

    Total Capacity4.1 m3Roof Area GF49.4 m2Paved Area46.0 m2Roof Area UF199.6 m2Total Area295.0 m2Capacity Required (Area x 0.0125)3.7 m3Extra Capacity Provided0.4 m3

    NOTE: ALL DOWNPIPESCONNECTED TO SOAKWELLS

    WITH PVC STORMWATERPIPE

    GARAGEGRANO @ -1c

    ALFRESCOPAVED @ -1c

    PORTICOPAVED @ -1c

    LOCATION OFFUTURE PCD

    SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENG.WIND CATEGORY : N3CORROSION CLASS : R4

    STORMWATER NOTE:STORMWATER DISPOSAL TO BUILDER'SSPECIFICATIONS.

    CONCRETE NOTE:SET SHOWER RECESS'S DOWN 50mm (25mmBELOW 25mm SET DOWN) & FIT REFLUXVALVE. MAINTAIN REQUIRED SLAB THICKNESSTO ENGINEERS REQUIREMENTS

    - LOCATION OF SERVICES

    ELECTRICAL NOTE:3 - PHASE POWER

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:1

    JOB N°:REVISION N°:

    VARIATIONS:

    04

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    GROUND FLOOR PLAN

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    AREASNameHOUSE - UPPERHOUSE - GROUNDGARAGEBALCONYALFRESCOPORTICO

    Area147.677135.00570.11023.14015.5102.641394.083 m²

    Perimeter57.98059.30039.57919.75618.4366.580

    SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENG.WIND CATEGORY : N3CORROSION CLASS : R4

    BUILD METHOD: CFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Concrete on Metal Truss UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System

    CEILING HEIGHT NOTE:ALL CEILINGS @ 31c UNLESS NOTED OTHERWISE.

    INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2340H (28c) U.N.O

    FIRE PROTECTION &TERMITE BARRIER

    BOX GUTTER

    VOID OVER

    SQUARE BULKHEAD

    RAKED CEILING

    EXTENT OF RENDER:EXTENT OF RENDER COLOUR 1 TO ENTIRE HOUSE

    EXCLUDING BOUNDARY WALLS.EXTENT OF RENDER COLOUR 2 TO ALFRESCO PIER.

    EXTENT OF STONE CLADDING TO LHS GARAGE WALL,ENTRY/VOID WALL, UF FIREPLACE AND PDR 1 WALL, ANDGAMES AND DINING REAR WALLS. EXTENT AS PER PLAN.

    TRIM DECK ROOF COVER

    1 2 3

    4 5 6 7 8 9

    UP

    SD

    SD

    EXTENT OFCLADDING

    EXTENT OFCLADDING

    EXTENT OF FEATURESTONE CLADDING

    SHOWN DOTTED

    EXTENT OFCLADDING

    EXTENT OFCLADDING

    EXTENT OF FEATURESTONE CLADDING

    SHOWN DOTTED

    WMWM

    REMOTE CONTROLSECTIONAL DOOR

    1200AF

    28xSP A 28x

    SP A

    18x

    810

    AH

    EAD

    @ 2

    8c

    OBS

    18x

    810

    AH

    EAD

    @ 2

    8c

    OBS

    28x

    3510

    SD

    28x

    2410

    A 28x1210 A

    28x

    SP S

    D

    28x3010 SD

    28x

    1610

    SD

    820MF

    2400

    x100

    0D

    HO

    820

    720

    720

    2 x 2

    8c S

    LDRS

    (BW

    K OV

    ER)

    720

    820

    820

    2 x FULL HT. SLDRS(SOFFIT OVER) 820

    620

    2x7201st

    720

    2 x 28c SLDRS(BWK OVER)

    3 x FULL HT. SLDRS(SOFFIT OVER)

    820MF

    28x SP A

    4310 x 2970

    5630 x 4490

    3820 x 3530

    3820 x 3910

    6510 x 5860

    3900 x 3270

    D.P

    INT. D.P

    INT. D.P

    D.P

    INT. D.P

    D.P

    D.P

    1770 x 1620

    D.P

    D.P

    800 800 2,500 1,720 16070

    50 990 100 5,110 490

    12,790

    3,900

    1,900

    700

    1,200

    2,290

    810

    590

    810

    390

    1,000

    2,410

    1,190

    3,510

    690

    300

    1,000

    3,900

    1,900

    700

    1,200

    4,890

    8,800

    300

    1,000

    22,69

    0

    800 990 1,210 100 2,390 100 1,300 3,010 1,390 645410

    445

    12,790

    200

    12,39

    010

    01,6

    103,6

    6023

    02,8

    2068

    01,0

    00

    200

    12,39

    05,3

    7023

    03,2

    0030

    01,0

    00

    22,69

    0

    700

    600

    1,600

    100

    1,242

    1,779

    800

    800 800 2,500 2,000 990 5,700

    800 2,300 2,390 1,400 4,400 1,500

    2,278

    1,252

    975

    975700

    970

    9,100

    500

    190

    190

    85

    135

    600 1

    35

    1,400

    290

    1,210

    290

    1,210

    290

    1,210

    290

    1,210

    290

    1,210

    290

    1,210

    290

    1,310

    300

    1,210

    290

    1,210

    290

    510

    290

    100100

    290310

    290 1,210100

    100

    3,270

    230

    1,000

    2,870 230 800 500

    1

    45

    STORMWATERPRELAYUNDER SLAB

    EXTENT OF RENDERCOLOUR 1 SHOWNDASHED

    EXTENT OF UPPERFLOOR SHOWN

    DASHED

    GARAGE OPENINGDW

    W SD D

    SDW

    WW

    W

    SDSD

    ENTRY

    PORTICO

    GARAGE

    MUD

    BED 2

    BATH

    BED 3

    GAMES

    BED 4

    ALFRESCO

    LAUNDRY

    CELLAR

    FREE

    STAN

    DING

    BATH

    ROBELINEN

    ROBE

    LINEN

    31c CL PLASTERBOARDPAVED @ -1c

    31c CL PLASTERBOARDGRANO @ -1c

    RENDER INTERNALLY

    T-BAR @ 28c

    STAIR INFORISER HEIGHT = 181.5TREAD WIDTH = 250

    OVERALL

    OVERALL

    OVER

    ALL

    OVER

    ALL

    TILED

    TILED

    SC

    CAVI

    TYCL

    OSER

    CAVITYCLOSER

    1050

    H BA

    LUST

    RADE

    510x310PLUMB DUCTw/ ACCESS PANELSILL @ 3cHEAD @ 7c

    BWK UNDERSTAIRS

    31c CL

    PHYS

    ICAL

    TER

    MITE

    BAR

    RIER

    & FI

    RE S

    EPAR

    ATIO

    N RE

    Q'D

    BOUN

    DARY

    WAL

    L w/

    SQUA

    RELI

    NE G

    UTTE

    R @

    32c

    TO B

    E SE

    TBAC

    K 10

    0mm

    FROM

    BOU

    NDAR

    Y

    FFL = 0cCL = 31c

    BOUNDA

    RY LIN

    E

    BOUN

    DARY

    LINE

    VOID OVER

    HOBLESS

    600x343TILED RECESS

    SILL @ 14cHEAD @ 18c

    SC

    STOR

    E

    LINING TOU/S OFSTAIRS

    30.660

    89°59'53"

    23.390

    135°

    0'0"

    101°

    18'20

    "

    BOX GUTTEROVER

    DBL G

    LAZI

    NG

    DBL GLAZING

    DBL G

    LAZI

    NG

    DBL G

    LAZI

    NGDB

    L GLA

    ZING

    DBL GLAZING

    DBL G

    LAZI

    NG

    1.022

    38.975

    COMB M/BOX(3 PHASE)

    BLADE WALL UPTO 33c

    28c SQUAREBULKHEAD

    EXTENT OFUF CANTILEVER

    SHOWN DASHED

    INST.GAS HWU

    1900hDOOR

    B'TOPONLY

    RAKEDCEILINGUNDERSTAIRS

    29c CL

    540x310PLUMB DUCT

    w/ ACCESS PANELSILL @ 3c

    HEAD @ 7c

    W

    OUTDOORSHRDBL GLAZING DBL GLAZING

    TRANSLUCENT

    W

    28c x SP FDBL GLAZING

    TOP OF POSTFOOTING @ -3c

    130mm DIAMETERROUND STEEL

    POST UP TO 6376mm

    EXTENT OFRENDER COLOUR 2SHOWN DOTTED

    3

    SHR

    910

    ROBE

    PDR 1TILED

    EXTENT OFRENDER

    EXTENT OFRENDER

    LOCATION OFFUTURE PCD

    WMREC

    DRREC

    28c E

    AVES

    28c S

    Q. B

    'HEA

    D

    28c CL

    2

    TOTAL

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:1

    JOB N°:REVISION N°:

    VARIATIONS:

    05

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    UPPER FLOOR PLAN

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENG.WIND CATEGORY : N3CORROSION CLASS : R4

    BUILD METHOD: CFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Concrete on Metal Truss UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System

    CEILING HEIGHT NOTE:ALL CEILINGS @ 31c UNLESS NOTED OTHERWISE.

    INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2340H (28c) U.N.O

    AREASNameHOUSE - UPPERHOUSE - GROUNDGARAGEBALCONYALFRESCOPORTICO

    Area147.677135.00570.11023.14015.5102.641394.083 m²

    Perimeter57.98059.30039.57919.75618.4366.580

    UPPER FLOOR CONSTRUCTION NOTEALLOW EXTRA STUDWORK FOR: - WC ROLL HOLDER @ 750mm - TOWEL RAIL @ 1000mm - TOWEL RING @ 1200mm - TOILET @ 750mm

    UPPER FLOOR HEIGHTSFFL =3086mmCL = 5778mmHEIGHT O/A= 2692mm (31c)

    VOID BELOW

    BOX GUTTER

    SQUARE BULKHEAD

    EXTENT OF RENDER:EXTENT OF RENDER COLOUR 1 TO ENTIRE HOUSE

    EXCLUDING BOUNDARY WALLS.EXTENT OF RENDER COLOUR 2 TO ALFRESCO PIER.

    EXTENT OF STONE CLADDING TO LHS GARAGE WALL,ENTRY/VOID WALL, UF FIREPLACE AND PDR 1 WALL, ANDGAMES AND DINING REAR WALLS. EXTENT AS PER PLAN.

    TRIM DECK ROOF COVER

    4 5 6 7 8 91011121314151617DN

    SD

    1543x1010 F

    2474x2210 A

    1543

    x121

    0 A

    820

    820CAV SD

    720

    2474 x SP SD

    820CAV SD

    567x

    1810

    OBS

    686x

    1210

    F68

    6x23

    10 F

    567x

    1810

    OBS

    600x

    2310

    OPE

    NIN

    G

    2474x1710 F

    2474

    x301

    0 A

    2474

    x251

    0 F

    2474

    x251

    0 F

    2474

    x251

    0 F

    2474

    x S

    P SD

    2474x1260 F2400 x SP F

    2143x1000OPENING

    2143x1000OPENING720

    FR REC

    4740 x 3910

    2690 x 1600

    DWREC

    PTY

    4190 x 4610

    4020 x 4830

    4920 x 4020

    MH

    7.5m

    CONE

    OF V

    ISION

    D.P

    D.P

    D.P

    2730 x 3350 1500 x 3350

    1

    45

    38c BLADE WALL

    33c BLADE WALL

    3

    100 250 1,710 90 2,390 4,300 1,000

    100 2,050 2,390 5,160 140

    1,540

    1,900

    250

    3,010

    580

    390

    1,210

    560

    1,270

    2,510

    150

    2,510

    150

    2,510

    250

    500

    1,000

    1,540

    5,740

    2,160

    9,350

    500

    1,000

    690 290 2,210 250 400 1,260 1,810 1,010 1,780 140

    3,680

    1,810

    250

    1,810

    730

    1,210

    1,990

    2,310

    1,480

    3,330

    690

    1,000

    15,27

    03,7

    9023

    01,0

    00

    600

    1,640

    740

    2,200

    2,140

    640

    300

    690 2,500 1,960 4,550 140

    9,100

    2,322

    1,770

    220

    700 23

    0

    20,29

    0

    650

    650

    9,840

    250

    200

    20,29

    0

    750

    2,310

    730

    230

    9,840

    4,270 1,030

    40

    40

    40

    40

    103° 10' 49"

    76° 4

    9' 11

    "

    EXTENT OF GROUNDFLOOR SHOWN

    DASHED

    100mm THERMAL CLADDINGTO OUTSIDE OF STUD(EXTENT SHOWN DASHED)

    36c BLADEWALL

    BOXGUTTER

    28c SQ.B'HEAD

    BALCONY

    DINING

    LIVINGKITCHEN

    SCULLERY

    ENSUITE

    MASTER SUITE

    DRESSING

    STUDYPDR 2

    WW

    WW

    W SD

    WW

    W

    VOID

    WC

    HOBL

    ESS

    TILED

    TILED

    TILED

    GAS HPINT. FLUMED

    R/HOOD2x UBO

    FR TAPBa

    nk of

    3 Dra

    wers

    2x B

    ank o

    f3 D

    rawe

    rsO'

    Head

    Cpb'd

    sO'

    Head

    Cpb'd

    s

    Bin D

    rawe

    r

    UndermountSink & Mixer

    WaterfallEnd

    Waterfall End

    DW T

    AP

    Bank of5 Drawers

    Bank

    of3 D

    rawe

    rs

    O'Head Cpb'ds

    700x300TILED RECSILL @ 1200 AFLHEAD @ 1500 AFL

    FFL = 3000mm TILEDCL = 5778mm P'BOARDHEIGHT O/A = 2778mm

    ROOFBELOW

    ROOFBELOW

    FALL

    FALL

    AC

    AC

    1050H BALUSTR

    ADE

    SD

    NO CORNERCOLUMN

    1050

    H BA

    LUST

    RADE

    STAIR INFORISER HEIGHT = 181.5

    TREAD WIDTH = 250

    DBL G

    LAZI

    NG

    DBL GLAZING

    DBL GLAZING

    DBL GLAZING

    DBL G

    LAZI

    NG

    DBL G

    LAZI

    NGDBL GLAZING

    DBL G

    LAZI

    NGRAKING CEILING

    5° PITCHCOLORBOND ROOF

    OVERALL

    OVERALLOV

    ERAL

    L

    OVER

    ALL

    FITOUT BYOWNER

    31c CL

    B'top only

    TOUG

    HENE

    D

    700x1140 SKYLIGHTLOCATION TBC

    550x550

    EXTENT OFFEATURE

    STONE CLADDINGSHOWN DOTTED

    EXTENT OFRAKING CEILINGSHOWN DASHED

    2° PITCHROOF

    FIRE PLACEOPENINGSILL @ 0c

    HEAD @ 7c

    W

    DBL G

    LAZI

    NG

    STUDY28c CL

    31c CL

    DBL GLAZING

    SC

    W

    W28c CL FR

    EEST

    ANDI

    NGBA

    TH

    28c CL

    31c CL

    T-BAR @ XXc42

    9x80

    10 W

    INDO

    W O

    VER

    DBL G

    LAZI

    NG429x1710 WINDOW OVER

    DBL GLAZINGT-

    BAR

    OVER

    OPEN

    ING

    19c AFLWALL

    EXTENT OFFEATURE

    STONE CLADDINGSHOWN DOTTED

    LVL

    LVL

    ROUND STEELPOST UP TO

    6376mm

    EXTENT OFFEATURESTONE CLADDINGSHOWN DOTTED

    WW

    EXTENT OFRENDER COLOUR 2

    SHOWN DOTTED

    2

    SHR

    FRREC

    28c SQ.B'HEAD

    B'top

    only

    GAS

    HP

    28c SQ. B'HEAD

    TOTAL

    timkTypewriterobs

    timkTypewriterobs

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100

    JOB N°:REVISION N°:

    VARIATIONS:

    06

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    ELEVATIONS

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    FL 0 (0c)

    CL 2657 (31c)

    FL 3086 (3086mm)

    CL 5778 (5778mm) 5778

    41c

    28c

    5560

    4017

    5560 4886

    6688

    3086

    28c

    21c

    0c

    33c

    36c

    5560

    41c

    4886

    28c

    0c

    2,657

    429

    2,692

    6,748

    COLORBOND GUTTERS,FASCIA AND DOWNPIPES

    AUTOSECTIONAL DOOR

    T-BAR @ 28c

    ENTRYDOOR

    5° PITCH COLORBOND ROOF

    THERMAL CLADDINGw/ RENDER COLOUR 1

    TRANS-LUCENT

    FEATURESTONE

    CLADDING

    2° PITCH COLORBOND ROOF

    17.07

    17.05 17.

    1116.

    99 17.04

    NGLEXISITNGBRICK WALL

    F

    41c BLADEWALL

    MOULDING

    SC

    33c BLADEWALL

    BARGE AND CAPPING

    RENDER COLOUR 1

    5° COLORBONDROOF BEHIND

    BUILD

    ING

    HEIG

    HT

    130mm DIAMETERROUND STEEL

    POST UP TO6376mm

    FL 0 (0c)

    CL 2657 (31c)

    FL 3086 (3086mm)

    CL 5778 (5778mm)

    0c 0c

    28c

    10c

    28c

    10c 14c

    36c

    28c

    21c

    0c

    28c

    0c

    28c

    21c

    0c

    55c

    6653 6239 5810 5560

    3086

    5560

    4017

    5560

    3086

    4886

    6383 6211 6601

    41c

    28c

    33c

    31c

    6239 5810 5560

    3086

    6239 5810 5560

    3086

    2,657

    429

    2,692

    6,748

    TOP OF POSTSFOOTINGS @-3c

    NGLEXISITNG

    BRICK WALL

    16.9917.

    0017.07

    17.04

    17.04

    17.06

    BUILD

    ING

    HEIG

    HT FEATURESTONECLADDING

    INST.GASHWU

    RENDER COLOUR 1

    THERMAL CLADDINGw/ RENDER COLOUR 1

    MOULDING

    EG

    LOCATION OFFUTURE PCD

    COMB M'BOX(3-PHASE)

    19c AFLWALL

    1050HBALUSTRADE

    FEATURESTONE

    CLADDING

    41c BLADEWALL33c BLADE

    WALL

    OBS OBS

    130mm DIAMETERROUND STEELPOST UP TO6376mm

    RENDERCOLOUR 2

    6688 6688

    6418

    FL 0 (0c)

    CL 2657 (31c)

    FL 3086 (3086mm)

    CL 5778 (5778mm)

    41c

    32c 28c

    0c

    28c

    0c

    4715 4029

    4715 4029

    36c

    5388 4821

    55c

    5778 5388 4821

    5778

    2,657

    429

    2,692

    83

    5,778

    420

    8,140 2,050 5,370

    BOUNDARY WALL w/SQUARELINE GUTTER @ 32c

    TO BE SETBACK 100mm FROMBOUNDARY

    TOUGHENEDTHERMAL CLADDINGw/ RENDER COLOUR 1

    5° PITCHCOLORBOND ROOF

    FEATURESTONE

    CLADDING

    BARGE ANDCAPPING

    5° PITCHCOLORBOND ROOF

    FACE BRICK

    OBS

    BARGE ANDCAPPING

    RENDERCOLOUR 1

    SKYLIGHTLOCATION

    TBC

    OBS

    NGL 17.2

    217.

    0917.

    1217.

    0717.

    04

    BUILD

    ING

    HEIG

    HT

    19c HIGHAFL

    36c BLADEWALL

    OUTDOORSHR

    41c BLADE WALL

    OPENING

    RENDERCOLOUR 2

    5560 4960

    5560

    3086

    6688

    2400

    5486 5560

    3086

    28c

    21c

    0c

    28c

    0cFL 0 (0c)

    CL 2657 (31c)

    FL 3086 (3086mm)

    23c

    -1c

    33c

    5810

    3086

    41c

    31c

    5778

    36c

    55c

    6239

    28c

    0c

    21c

    2,657

    429

    2,692

    6,748F S S

    1050H BALUSTRADETHERMAL CLADDINGw/ RENDER COLOUR 1

    GARAGEDOOR

    SC

    BARGE AND CAPPING

    RENDERCOLOUR 1

    5° COLORBOND ROOF

    2° PITCHROOF BEHIND

    EXISITNGBRICK WALL

    17.04

    17.03

    BUILD

    ING

    HEIG

    HT

    NGL

    T-BAR @ 28c

    FEATURESTONE CLADDING

    19c AFLWALL

    41c BLADEWALL

    36c BLADEWALL

    33c BLADEWALL

    RENDERCOLOUR 2

    CL 5778 (5778mm)

    EXTENT OF RENDER:EXTENT OF RENDER COLOUR 1 TO ENTIRE HOUSE

    EXCLUDING BOUNDARY WALLS.EXTENT OF RENDER COLOUR 2 TO ALFRESCO PIER.

    EXTENT OF STONE CLADDING TO LHS GARAGE WALL,ENTRY/VOID WALL, UF FIREPLACE AND PDR 1 WALL, ANDGAMES AND DINING REAR WALLS. EXTENT AS PER PLAN.

    28c

    0c

    28c

    0c

    36c

    64c

    3000

    5560

    3086

    CL 2657 (31c)

    FL 3086 (3086mm)

    CL 5778 (5778mm)

    FL 0 (0c)

    2,657

    429

    2,692

    BALCONY

    ALFRESCO

    FEATURESTONECLADDINGAC

    RYLIC

    REND

    ER

    1 ELEVATION1:100

    2 ELEVATION1:100

    4 ELEVATION1:100

    3 ELEVATION1:100

    5 ELEVATION1:100

    timkTypewriterobs

    timkTypewriterobs

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:1

    JOB N°:REVISION N°:

    VARIATIONS:

    07

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    ELECTRICAL

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    NBN PROVISIONAL NOTE

    HOUSE TO BE FITTED WITH; - 1x SGPO WITH CONDUIT @ 1400 AFL, - 1x CONDUIT WITH DRAW-WIRE & BLANK PLATE (Cw) @ 1400 AFL FOR FUTURE PHONE/ DATA POINT, - 1x FIBRE COMMUNICATION CONDUIT WITH DRAWWIRE & BLANK PLATE (FC) NBN @ 1400 AFL.

    LOCATION OF FUTURE PCD (PREMISESCONNECTION DEVICE) TO BE NOMINATED ON PLANAT PRESTART.TO BE INSTALLED BY NBN PROVIDER.

    NOTE:FIBRE COMMUNICATION CONDUIT TO RUN FULLLENGTH FROM (FC) NBN PLATE TO FUTURE PCDLOCATION.

    LIGHT SWITCH BOX NOTELIGHT SWITCH BOX TO FIRST FLOOR TO BE 150mmMINIMUM FROM INTERNAL OPENING

    A/C NOTE:LOCATION OF REVERSE CYCLE AIR CONDITIONINGVENTS & ZONING TO BE PLACED BY INSTALLER.

    NOTE3 PHASE POWER REQUIRED.

    UPPER FLOOR ELECTRICAL LEGENDNUM1

    Text for legendSmoke Detector

    SymbSD

    GROUND FLOOR ELECTRICAL LEGENDNUM1

    1

    2

    1

    Text for legendData Point

    Phone Point

    Smoke Detector

    TV Point

    Symb

    SD

    NOTEPOSITION OF THE FOLLOWING TO BE CONFIRMEDAT PRESTART:- 1x TV POINT- 1x DATA POINT- 1x PHONE POINT- 60x 10w POWERLITE LED DOWNLIGHTS

    1 2 3

    4 5 6 7 8 9

    UP

    SD

    SD

    WMWM

    1st

    D.P

    INT. D.P

    INT. D.P

    D.P

    INT. D.P

    D.P

    D.P

    D.P

    D.P

    INST. GASHWU

    ENTRY

    PORTICO

    GARAGE

    MUD

    BED 2

    BATH

    BED 3

    GAMES

    BED 4

    ALFRESCO

    LAUNDRY

    CELLAR

    STOR

    E

    PLUMB DUCT

    PLUMB DUCT

    COMB M/BOX(3 PHASE)

    SHR PDR 1

    LOCATION OFFUTURE PCD

    4 5 6 7 8 91011121314151617DN

    SD

    FR REC

    DWREC

    PTY

    MH

    D.P

    D.P

    D.P

    550x550

    BALCONY

    DINING

    LIVINGKITCHEN

    SCULLERY

    ENSUITE

    MASTER SUITE

    DRESSING

    STUDYPDR 2

    WC

    STUDY

    SHR

    FRREC

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:1

    JOB N°:REVISION N°:

    VARIATIONS:

    08

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    SERVICE OVERLAY

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    NOTE:ELECTRICAL PLAN IS SHOWN LIGHTLY SHADED

    BELOW TO ALLOW FOR THE OVERLAY

    A/C NOTE:LOCATION OF AIR CONDITIONING VENTS & ZONING

    TO BE PLACED BY INSTALLER.

    NOTE:GIVE ALLOWANCE FOR ELECTRICAL LIGHTING

    BELOW FLOOR-TRUSS SYSTEM.

    CONCRETE TRUSS SYSTEM

    SERVICE OVERLAYNUM Text for legend Symb

    1 2 3

    4 5 6 7 8 9

    UP

    SD

    SD

    WMWM

    1st

    D.P

    INT. D.P

    INT. D.P

    D.P

    INT. D.P

    D.P

    D.P

    D.P

    D.P

    INST. GASHWU

    ENTRY

    PORTICO

    GARAGE

    MUD

    BED 2

    BATH

    BED 3

    GAMES

    BED 4

    ALFRESCO

    LAUNDRY

    CELLAR

    STOR

    E

    PLUMB DUCT

    PLUMB DUCT

    COMB M/BOX(3 PHASE)

    SHR PDR 1

    LOCATION OFFUTURE PCD

    4 5 6 7 8 91011121314151617DN

    BALCONY

    DINING

    LIVINGKITCHEN

    SCULLERY

    ENSUITE

    MASTER SUITE

    DRESSING

    STUDYPDR 2

    WC

    STUDY

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100, 1:50

    JOB N°:REVISION N°:

    VARIATIONS:

    09

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    STAIR LAYOUTS

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    BALUSTRADE AND STAIRTYPE TO BCAREQUIREMENTS

    STAIR INFORISER HEIGHT = 181.5TREAD WIDTH = 250

    BALUSTRADE MIN. HEIGHT1050 AFL

    BALUSTRADE STYLE ISINDICATIVE ONLY. REFER TOADDENDA

    DRYWALL LINING TO ALLSTAIRWELL WALLS

    10111213141516171

    050H

    BAL

    USTR

    ADE

    CONCRETESTAIRS

    9876543

    21

    1050H

    BALUST

    RADE

    NOMIN

    ATED

    STRING

    ER

    FL 3086 (3086mm)

    CL 5778 (5778mm)

    CL 2657 (31c)

    FL 0 (0c)

    2,657

    429

    2,692

    3,086

    17 R

    ISER

    S @

    181.5

    mm

    BALUSTRADE HEIGHT1050AFL TO BCAREQUIREMENT

    BALUSTRADE ANDSTAIR TYPE TO BCA

    REQUIREMENT

    1 2 3

    4

    5

    6

    7

    8

    9

    UP

    16

    LINING TOU/S OFSTAIRS

    STORE

    BWKUNDERSTAIRS

    CLOSEDUNDER STAIRS

    CONCRETESTAIRS

    1050

    H BA

    LUST

    RADE

    RAKEDCEILINGUNDERSTAIRS

    1900H DOOR

    1900

    2,112

    STORE

    RAKED CEILINGUNDER STAIRS

    123

    45

    67

    89

    1011

    1213

    1415

    1617

    CONCRETESTAIRS

    CLOSED UNDERSTAIRS

    1050H

    BALUST

    RADE

    THRU TOPASS

    CELLAR

    1050H BALUSTRADE

    NOMIN

    ATED S

    TRING

    ER

    BWK UNDERSTAIRS

    MDF TO SLABEDGE

    FL 3086 (3086mm)

    CL 5778 (5778mm)

    CL 2657 (31c)

    FL 0 (0c)

    2,657

    429

    2,692

    3,086

    17 R

    ISER

    S @

    181.5

    mm

    BALUSTRADE HEIGHT1050AFL TO BCAREQUIREMENT

    BALUSTRADE ANDSTAIR TYPE TO BCA

    REQUIREMENT

    250 250 1,000

    500 1,000

    1,500

    1,000

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    1,000

    3,250

    4,250

    1,000

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    250

    1,000

    3,250

    1,410

    901,9

    1090

    750

    4,250

    250 250 1,000

    500 1,000

    500 90 91050 1,500

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17DN

    SD

    820 CONCRETESTAIRS

    1050

    H BA

    LUST

    RADE

    550x550

    1050

    H BA

    LUST

    RADES2 S

    1

    1 STAIRS1:50

    2 STAIRS1:50

    UF STAIRS LAYOUT1:50

    GF STAIRS LAYOUT1:50

    STAIR PERSPECTIVE 1 STAIR PERSPECTIVE 2

  • SITE ADDRESS:OWNER ................................DATE...............................

    OWNER ...............................DATE................................

    BUILDER ...............................DATE................................

    DATE: 20/08/2020SCALE: 1:100

    JOB N°:REVISION N°:

    VARIATIONS:

    10

    SALES: DRAWN:CL TD TKCHECKED:

    SHEET N°: of 09

    1904R11

    PERSPECTIVES

    01

    REV: DESCRIPTION: INT: DATE: WEINBAUER

    SSL 1 (#28A) DILKARA WAYCITY BEACH WA 6015

    CLIENT: PREMIUM VENADO

    BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

    Copy

    right

    2011

    ©

    THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

    /C1S/

    /C2S/

    /BS/

    /C1D/

    /C2D/

    /BD/

    '1 ' CONTRACT (SILVER PLANS) TD 29.07.20 '2 ' '3' '4 ' '5' '6' '7' '8' '9' '10' '11' '12' '13'

    RESIDENTIAL ASSESSMENTADDITIONS TO, OR NEW SINGLE HOUSE/S, GROUPED DWELLINGS OR MULTIPLE DWELLINGS IN AREAS LESS THAN R40. Local Planning Policy 3.1 – Streetscape Local Planning Policy 3.2 – Buildings on the BoundaryA3 Book_REV 01.pdfA3 Book_REV 0101 EXISTING SITE PLAN02 SITE DEMOLITION PLAN03 SITE PLAN04 GROUND FLOOR PLAN05 UPPER FLOOR PLAN06 ELEVATIONS07 ELECTRICAL08 SERVICE OVERLAY09 STAIR LAYOUTS10 PERSPECTIVES

    200902 Neighbour Consent Ltr[1].pdfA3 Book_REV 01.pdfA3 Book_REV 0101 EXISTING SITE PLAN02 SITE DEMOLITION PLAN03 SITE PLAN04 GROUND FLOOR PLAN05 UPPER FLOOR PLAN06 ELEVATIONS07 ELECTRICAL08 SERVICE OVERLAY09 STAIR LAYOUTS10 PERSPECTIVES