svy area previous - science museum group
TRANSCRIPT
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_01
011924_02
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
01
011924_03
011924_05011924_04
011924_07
011924_06
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
AR
EA
SV
YA
RE
A
SV
YA
RE
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
P
o
st &
W
ire
F
e
n
ce
2
.0
0
H
t
2
0
4
.2
8
2
0
4
.5
3
2
0
4
.4
3
2
0
4
.2
1
204.00
203.78
2
0
3
.5
6
203.33
203.05
2
0
2
.8
3
2
0
2
.5
5
202.27
2
0
1
.9
6
201.71
2
0
1
.3
6
2
0
0
.9
7
200.57
200.31
199.99
199.72
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
204.09
2
0
4
.1
1
2
0
3
.9
4
2
0
3
.7
4
203.45
2
0
3
.2
4
2
0
3
.0
1
202.79
2
0
2
.5
2
202.17
2
0
1
.8
8
2
0
1
.5
9
201.33
2
0
0
.8
8
2
0
0
.5
7
200.29
199.99
199.59
GU
CL 203.33
GU
CL 206.99
SP
SP
200.68
201.44
202.20
2
0
3
.0
4
2
0
3
.6
8
204.43
205.24
206.00
206.68
2
0
7
.
3
0
2
0
7
.
9
7
208.35
2
0
8
.7
7
2
0
9
.
0
8
2
0
9
.
2
1
2
0
9
.
0
7
2
0
8
.
9
7
2
0
8
.
7
3
2
0
8
.
4
5
2
0
8
.
1
4
2
0
7
.
7
7
2
0
7
.
4
6
2
0
7
.
1
3
2
0
6
.
9
0
2
0
6
.
5
2
CL 208.95
202.65
201.80
2
0
1
.0
2
2
0
6
.8
6
206.41
2
0
5
.7
1
204.88
204.07
207.43
207.01
206.67
206.31
206.04
205.76
205.52
205.30
205.03
204.82
204.61
204.42
203.83
203.65
203.47
203.28
203.00
202.56
202.27
202.05
201.87
201.68
201.36
201.26
200.96
200.55
200.78
201.21
201.52
201.70
202.00
202.15
202.46
202.71
202.99
203.44
203.68
203.90
203.96
204.25
204.77
205.06
205.27
205.60
205.89
206.08
206.29
206.54
206.82
207.15
207.47
207.89
208.37
207.92
207.56
207.27
207.13
206.81
206.49
206.16
205.74
205.43
205.15
204.92
204.52
204.24
204.05
203.94
203.66
203.23
202.90
202.61
202.40
202.15
201.97
201.75
201.44
201.24
201.59
201.77
202.09
202.27
202.46
202.72
203.00
203.39
203.62
203.97
204.30
204.46
204.54
204.90
205.23
205.42
205.76
206.02
206.33
206.89
207.10
207.49
207.76
208.04
208.35
208.86
208.89
208.44
208.02
207.75
207.31
206.89
206.54
206.22
205.86
205.59
205.48
205.09
204.81
204.63
204.43
204.10
203.75
203.51
203.26
203.00
202.68
202.45
202.14
201.95
201.73
201.93
201.95
201.99
202.36
202.90
203.04
203.24
203.60
203.87
204.16
204.46
204.78
205.03
205.24
205.44
205.80
205.98
206.20
206.47
206.81
207.16
207.54
207.94
208.40
208.89
208.32
207.91
207.43
206.92
206.64
206.41
206.15
205.92
205.64
205.44
205.14
204.84
204.50
204.23
204.00
203.81
203.43
203.03
202.82
202.61
202.43
202.24
201.99
202.20
202.16
202.42
202.50
202.85
203.05
203.51
203.75
203.91
204.20
204.34
204.46
204.73
205.06
205.47
205.85
206.09
206.32
206.58
206.84
207.14
207.84
208.31
207.59
207.17
206.70
206.46
206.24
205.94
205.50
205.13
204.75
204.45
204.17
204.07
203.89
203.68
203.32
203.05
202.78
202.63
202.47
202.24
202.30
202.52
202.72
202.95
203.14
203.37
203.66
203.94
204.20
204.41
204.63
204.93
205.32
205.70
206.06
206.33
206.52
206.86
207.43
207.09
206.76
206.35
206.07
205.78
205.34
205.03
204.73
204.50
204.23
204.01
203.77
203.42
203.17
202.94
202.74
202.58
202.41
203.46
203.76
204.08
204.35
204.59
204.77
205.14
205.47
205.85
206.23
206.58
206.18
206.04
205.55
B01
E 413434.905
N 178689.052
Z 206.146
WM
Concrete Slab
P
o
s
s
i
b
l
e
P
/
E
W
a
t
e
r
(0.40dx2)
(
0
.6
5
d
)
(
0
.
6
0
d
)
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
(1
.5
0
d
)
(1
.5
0
d
)
(1
.5
0
d
)
(1
.5
0
d
)
(1
.5
0
d
)
(1.30d)
(1.30d)
(0.30d)
W
W
W
W
W
W
CL 206.86
FH
UTT
S
c
a
r
(1.10d)
Gravel
G
ra
ve
l
Gravel
G
ra
ve
l
G
ra
ve
l
G
ravel
Tarmac
Tarmac
Tarmac
Tarmac
Grass
Grass
Grass
Grass
Grass
Grass
Grass
2
0
5
.
5
0
2
0
6
.
5
0
2
0
7
.
5
0
2
0
8
.
5
0
2
0
3
.
5
0
2
0
4
.
5
0
2
0
1
.
5
0
2
0
2
.
5
0
2
0
0
.
5
0
206.50
2
0
7
.
5
0
2
0
8
.
5
0
2
0
2
.
5
0
2
0
3
.
5
0
2
0
4
.
5
0
2
0
5
.
5
0
2
0
6
.
5
0
2
0
7
.5
0
2
0
6
.
0
0
2
0
7
.
0
0
2
0
8
.
0
0
2
0
9
.
0
0
2
0
4
.
0
0
2
0
5
.
0
0
2
0
2
.
0
0
2
0
3
.
0
0
2
0
1
.
0
0
206.00
2
0
7
.
0
0
2
0
8
.
0
0
202.00
2
0
3
.
0
0
2
0
4
.
0
0
2
0
5
.
0
0
2
0
6
.
0
0
2
0
7
.
0
0
204.00
G
ra
ve
l
G
ravel
G
ravel
G
ra
ve
l
G
ravel
G
ravel
G
ravel
Grass
Grass
P
o
st &
W
ire
F
e
n
ce
2
.0
0
H
t
P
o
st &
W
ire
F
e
n
ce
2
.0
0
H
t
P
ost &
W
ire F
ence 2.00H
t
413325E
413325E
413350E
413350E
413375E
413375E
413400E
413400E
413425E
413425E
413450E
413450E
413475E
413475E
413500E
413500E
413525E
413525E
413550E
413550E
413575E
413575E
178575N 178575N
178600N 178600N
178625N 178625N
178650N 178650N
178675N 178675N
178700N 178700N
178725N 178725N
178750N 178750N
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_02
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
02
011924_03
011924_05011924_04
011924_07
011924_06
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
2
0
0
.9
7
200.57
200.31
199.99
199.72
1
9
9
.4
0
1
9
9
.1
4
198.86
1
9
8
.6
1
1
9
8
.4
2
198.14
1
9
7
.8
9
197.59
1
9
7
.3
9
197.19
196.98
196.79
1
9
6
.6
6
196.50
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
2
0
0
.8
8
2
0
0
.5
7
200.29
199.99
199.59
199.38
199.05
1
9
8
.8
0
198.48
198.28
198.14
197.80
197.60
1
9
7
.3
7
197.19
196.98
196.79
196.49
196.42
197.03
197.52
198.08
198.50
199.06
199.83
200.68
201.44
202.20
1
9
7
.6
8
1
9
7
.2
3
196.82
201.80
2
0
1
.0
2
200.20
199.32
198.77
1
9
8
.3
0
202.27
202.05
201.87
201.68
201.36
201.26
200.96
200.55
200.39
200.12
199.87
199.53
199.39
199.04
198.93
198.69
198.59
198.40
198.23
198.15
197.89
197.69
197.46
197.30
197.23
197.03
197.03
197.05
197.09
197.42
197.54
197.65
197.79
198.12
198.39
198.52
198.69
198.87
198.94
199.15
199.37
199.56
199.88
200.07
200.45
200.82
200.78
201.21
201.52
201.70
202.00
202.15
202.46
202.61
202.40
202.15
201.97
201.75
201.44
201.24
200.99
200.72
200.44
200.14
199.86
199.47
199.23
199.07
198.91
198.80
198.56
198.47
198.23
198.00
197.78
197.54
197.39
197.10
197.03
196.94
197.04
197.16
197.45
197.50
197.68
197.98
198.16
198.35
198.69
198.90
199.06
199.11
199.39
199.61
199.86
200.21
200.55
200.80
201.09
201.37
201.59
201.77
202.09
202.27
202.46
202.72
203.00
203.26
203.00
202.68
202.45
202.14
201.95
201.73
201.41
201.26
200.98
200.67
200.53
200.33
199.80
199.46
199.19
198.97
198.98
198.54
198.33
198.11
197.91
197.57
197.44
197.21
197.11
197.22
197.44
197.59
197.80
198.08
198.30
198.48
198.72
198.98
199.17
199.40
199.79
199.94
200.17
200.52
200.80
201.08
201.34
201.56
201.93
201.95
201.99
202.36
202.90
203.04
203.24
203.60
203.81
203.43
203.03
202.82
202.61
202.43
202.24
201.99
201.68
201.46
201.29
201.04
200.79
200.39
200.14
199.83
199.51
199.25
199.09
198.91
198.64
198.50
198.21
197.95
197.75
197.63
197.44
197.58
197.73
197.86
198.05
198.34
198.54
198.85
199.02
199.20
199.41199.41
199.73
200.03
200.46
200.71
200.93
201.36
201.55
201.89
201.94
202.20
202.16
202.42
202.50
202.85
203.05
203.51
203.75
203.91
203.68
203.32
203.05
202.78
202.63
202.47
202.24
202.09
201.98
201.52
201.43
201.08
200.72
200.45
200.07
199.80
199.54
199.29
199.19
198.97
198.77
200.47
200.85
201.12
201.49
201.68
201.98
202.15
202.30
202.52
202.72
202.95
203.14
203.37
203.66
203.77
203.42
203.17
202.94
202.74
202.58
202.41
202.16
203.46
203.76
B02
E 413613.981
N 178735.466
Z 201.768
(0.40dx2)
U
U
U
U
GU
CL 197.82
G
ravel
G
ravel
G
ra
ve
l
G
ravel
G
ravel
Tarmac
Tarmac
Tarmac
Grass
Grass
Grass
Grass
Grass
2
0
1
.
5
0
1
9
9
.
5
0
2
0
0
.
5
0
1
9
7
.5
0
1
9
8
.
5
0
1
9
7
.
5
0
1
9
8
.
5
0
1
9
9
.
5
0
2
0
0
.
5
0
2
0
1
.
5
0
2
0
2
.
5
0
1
9
7
.
5
0
2
0
2
.
0
0
1
9
9
.
0
0
2
0
0
.
0
0
2
0
1
.
0
0
1
9
7
.0
0
1
9
8
.
0
0
1
9
8
.
0
0
1
9
9
.
0
0
2
0
0
.
0
0
2
0
1
.
0
0
202.00
2
0
3
.
0
0
G
ra
ve
l
G
ra
ve
l
G
ravel
G
ravel
G
ra
ve
l
G
ra
ve
l
G
ravel
P
ost &
W
ire F
ence 2.00H
t
P
ost &
W
ire F
ence 2.00H
t
P
ost &
W
ire F
ence 2.00H
t
413525E
413525E
413550E
413550E
413575E
413575E
413600E
413600E
413625E
413625E
413650E
413650E
413675E
413675E
413700E
413700E
413725E
413725E
413750E
413750E
178575N 178575N
178600N 178600N
178625N 178625N
178650N 178650N
178675N 178675N
178700N 178700N
178725N 178725N
178750N 178750N
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_03
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
03
011924_02
011924_05011924_04
011924_07
011924_06
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
1
9
6
.4
4
1
9
6
.3
2
1
9
6
.2
4
1
9
6
.
1
9
1
9
6
.
2
1
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
6
.
1
2
1
9
6
.
1
7
1
9
6
.
2
1
197.19
196.98
196.79
1
9
6
.6
6
196.50
1
9
6
.3
8
1
9
6
.2
8
196.15
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
197.19
196.98
196.79
196.49
196.42
196.50
196.30
196.16
1
9
6
.1
1
1
9
5
.9
9
1
9
5
.8
1
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.7
5
1
9
5
.6
3
1
9
5
.5
5
195.48
1
9
5
.3
9
1
9
5
.3
2
195.42
195.3
4
195.60
1
9
5
.
7
0
1
9
5
.
7
1
GU
CL 196.42
SP
SP
1
9
6
.3
7
196.49
1
9
6
.6
2
196.73
197.03
197.52
1
9
7
.0
1
1
9
6
.9
1
1
9
7
.6
8
1
9
7
.2
3
196.82
197.89
197.69
197.46
197.30
197.23
197.03
197.03
196.79
196.81
196.67
196.57
196.43
196.51
196.56
196.69
196.73
196.90
197.05
197.09
197.42
197.54
197.65
197.79
198.00
197.78
197.54
197.39
197.10
197.03
196.94
196.75
196.73
196.58
196.61
196.68
196.71
196.86
196.89
197.04
197.16
197.45
197.50
197.68
197.98
198.16
198.33
198.11
197.91
197.57
197.44
197.21
197.11
196.96
196.85
196.69
196.71
196.81
196.78
197.03
197.20
197.22
197.44
197.59
197.80
198.08
198.30
198.48
198.64
198.50
198.21
197.95
197.75
197.63
197.44
197.31
197.13
197.08
196.89
197.43
197.58
197.73
197.86
198.05
198.34
198.54
198.77
(0.60dx2)
(0
.5
0
d
)
(0.4
5d) GU
CL 196.27
U
U
U
U
196.23
GU
CL 196.16
GU
CL 196.29
(0.40dx2)
(0.40dx2)
1
9
5
.
7
5
1
9
5
.
6
8
1
9
5
.
6
9
1
9
5
.
7
5
1
9
5
.
8
2
1
9
5
.
9
4
G
ravel
G
ravel
Tarmac
Tarmac
Tarmac
Grass
Grass
Tarmac
Tarmac
Tarmac
1
9
7
.5
0
1
9
6
.
5
0
1
9
6
.
5
0
1
9
7
.
5
0
1
9
7
.
5
0
1
9
7
.0
0
1
9
7
.
0
0
1
9
7
.
0
0
1
9
8
.
0
0
G
r
a
v
e
l
G
r
a
v
e
l
G
ra
ve
l
G
ra
ve
l
P
ost &
W
ire F
ence 2.00H
t
P
ost &
W
ire F
ence 2.00H
t
P
o
st &
W
ire
F
e
n
ce
2
.0
0
H
t
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
413725E
413725E
413750E
413750E
413775E
413775E
413800E
413800E
413825E
413825E
413850E
413850E
413875E
413875E
413900E
413900E
413925E
413925E
413950E
413950E
178575N 178575N
178600N 178600N
178625N 178625N
178650N 178650N
178675N 178675N
178700N 178700N
178725N 178725N
178750N 178750N
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_04
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
04
011924_03
011924_05
011924_02
011924_07
011924_06
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
SP
2
0
6
.
0
2
2
0
5
.
5
4
2
0
5
.
0
8
2
0
4
.
5
8
2
0
4
.
1
6
2
0
3
.
7
3
2
0
3
.
2
9
2
0
2
.
8
8
2
0
2
.
5
6
2
0
2
.
1
7
2
0
1
.
8
1
2
0
1
.
3
3
2
0
0
.
9
6
2
0
0
.
5
8
2
0
0
.
3
8
2
0
0
.
0
9
1
9
9
.
7
9
200.39
200.14
199.83
199.51
199.25
199.09
199.20
199.41199.41
199.73
200.03
200.46
200.71
200.93
201.36
201.55
201.89
201.94
202.20
202.16
202.42
203.89
203.68
203.32
203.05
202.78
202.63
202.47
202.24
202.09
201.98
201.52
201.43
201.08
200.72
200.45
200.07
199.80
199.54
199.29
199.19
199.18
199.44
199.72
199.82
200.18
200.47
200.85
201.12
201.49
201.68
201.98
202.15
202.30
202.52
202.72
202.95
203.14
203.37
203.66
203.94
204.20
204.41
204.63
204.93
205.32
205.70
206.07
205.78
205.34
205.03
204.73
204.50
204.23
204.01
203.77
203.42
203.17
202.94
202.74
202.58
202.41
202.16
201.97
201.73
201.55
201.19
200.93
200.53
200.23
199.99
199.81
199.61
199.34
199.50
199.82
199.96
200.22
200.31
200.65
201.00
201.28
201.61
201.84
201.99
202.29
202.45
202.61
202.82
203.06
203.21
203.46
203.76
204.08
204.35
204.59
204.77
205.14
205.47
205.85
206.23
206.18
206.04
205.55
205.29
204.86
204.58
204.34
204.05
203.95
203.60
203.28
203.13
202.94
202.80
202.56
202.45
202.23
201.94
201.81
201.32
200.70
200.39
200.31
200.15
199.89
199.53
199.64
199.85
200.09
200.35
200.48
200.64
201.13
201.38
201.78
202.06
202.27
202.40
202.63
202.84
202.98
203.10
203.31
203.47
203.88
204.13
204.38
204.63
204.87
205.39205.39
205.65
205.76
205.21
204.91
204.47
204.16
203.95
203.76
203.42
203.24
202.98
202.88
202.79
202.58
202.30
202.19
202.01
201.69
201.34
200.96
200.56
200.46
200.27
200.13
199.89
199.71
199.45
199.71
199.84
200.08
200.28
200.51
200.64
200.92
201.30
201.52
201.89
202.13
202.35
202.57
202.69
202.82
202.96
203.19
203.36
203.62
203.86
204.06
204.37
204.16
203.91
203.69
203.38
203.16
203.07
202.78
202.69
202.60
202.37
202.24
201.96
201.73
201.45
201.17
200.89
200.63
200.44
200.17
199.97
199.81
199.54
199.32
199.39
199.56
199.76
199.89
200.18
200.42
200.51
200.83
201.12
201.27
201.55
201.78
202.03
202.22
202.45
202.55
202.66
202.80
203.02
203.21
203.44
202.98
202.70
202.57
202.48
202.37
202.30
202.14
201.90
201.74
201.42
201.28
201.01
200.84
200.58
200.37
200.10
199.92
199.80
199.63
199.44
199.44
199.58
199.60
199.74
199.94
200.16
200.40
200.50
200.73
201.00
201.27
201.45
201.64
201.75
201.99
202.07
202.16
202.37
201.83
201.66
201.67
201.57
201.29
201.25
200.96
200.80
200.62
200.42
200.22
200.01
199.92
199.77
199.53
199.45
199.23
199.21
199.28
199.41
199.55
199.72
199.87
200.07
200.20
200.34
200.58
200.80
201.07
201.11
201.11
201.33
201.45
201.14
201.02201.02
200.96
200.93
200.76
200.69
200.43
200.23
200.04
199.83
199.63
199.51
199.36
199.34
199.25
199.18
198.95
198.93
199.10
199.20
199.30
199.38
199.42
199.60
199.65
199.77
199.93
200.16
200.39
200.53
200.58
200.75
200.47
200.31
200.13
200.14
199.91
199.71
199.63
199.45
199.31
199.30
199.26
199.08
199.06
198.99
198.88
198.88
198.83
198.97
199.01
199.15
199.18
199.23
199.36
199.54
199.65
199.82
200.02
199.97
200.09
199.94
199.86
199.67
199.52
199.37
199.17
199.03
199.00
B02
E 413613.981
N 178735.466
Z 201.768
P
o
s
s
i
b
l
e
P
/
E
W
a
t
e
r
(
0
.
9
0
d
)
S
c
a
r
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
1
9
9
.
5
0
2
0
0
.5
0
201.50
2
0
2
.5
0
2
0
3
.
5
0
2
0
4
.
5
0
205.50
1
9
9
.5
0
200.50
201.50
2
0
2
.
5
0
2
0
3
.5
0
1
9
9
.
5
0
2
0
0
.
5
0
2
0
0
.
0
0
201.00
202.0
0
2
0
3
.
0
0
2
0
4
.
0
0
205.00
206.00
2
0
0
.
0
0
201.00
2
0
2
.
0
0
2
0
3
.0
0
204.00
1
9
9
.
0
0
2
0
0
.
0
0
2
0
1
.
0
0
1
9
9
.
0
0
413450E
413450E
413475E
413475E
413500E
413500E
413525E
413525E
413550E
413550E
413575E
413575E
413600E
413600E
413625E
413625E
413650E
413650E
413675E
413675E
178725N 178725N
178750N 178750N
178775N 178775N
178800N 178800N
178825N 178825N
178850N 178850N
178875N 178875N
178900N 178900N
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_05
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
05
011924_03011924_02
011924_04
011924_07
011924_06
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
Empty Duct
Cover
CL 197.02
1
9
7
.3
7
1
9
7
.3
6
1
9
7
.4
0
1
9
7
.4
4
1
9
7
.4
1
1
9
7
.4
0
1
9
7
.3
2
1
9
7
.2
2
1
9
7
.2
2
1
9
7
.1
2
1
9
7
.0
0
1
9
6
.9
4
1
9
6
.8
2
1
9
6
.7
0
1
9
6
.5
7
1
9
6
.4
4
1
9
6
.3
2
1
9
6
.2
4
1
9
6
.
1
9
1
9
6
.
2
1
1
9
6
.
3
3
1
9
6
.
4
8
1
9
6
.
5
7
1
9
6
.
6
1
1
9
6
.
6
6
1
9
6
.
6
3
1
9
6
.
6
3
1
9
6
.
6
0
1
9
6
.
5
5
1
9
6
.
5
4
1
9
6
.
4
9
1
9
6
.
4
8
1
9
6
.
4
6
GU
CL 197.32
GU
CL 197.39
GU
CL 197.35
GU
CL 197.22
GU
CL 197.06
GU
CL 196.90
GU
CL 196.66
GU
CL 196.50
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
6
.
1
2
1
9
6
.
1
7
1
9
6
.
2
1
1
9
6
.
3
5
1
9
6
.
5
0
1
9
6
.
6
1
1
9
6
.
6
8
1
9
6
.
7
0
1
9
6
.
6
9
1
9
6
.
6
6
1
9
6
.
6
3
1
9
6
.
5
8
1
9
6
.
5
5
1
9
6
.
5
6
1
9
6
.
5
2
1
9
6
.
4
7
Cover
CL 196.65
(0
.4
0
d
)
(0
.5
0
d
)
(1
.2
0
d
)
(0
.6
0
d
)
(0
.4
0
d
)
(
0
.4
0
d
)
(
0
.7
0
d
)
(
0
.7
0
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
BT IC
CL 197.49
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B03
E 413859.141
N 178809.568
Z 197.114
1
9
7
.3
8
1
9
7
.5
7
1
9
7
.7
4
1
9
7
.8
4
1
9
7
.9
5
1
9
8
.0
4
1
9
8
.0
0
1
9
8
.0
1
1
9
7
.9
6
1
9
7
.8
3
1
9
7
.7
1
1
9
7
.4
4
1
9
7
.2
4
1
9
7
.0
1
1
9
6
.9
1
197.11
196.96
196.85
196.69
196.71
196.81
196.78
197.03
197.20
197.22
197.44
197.59
197.80
198.08
198.30
198.48
198.91
198.64
198.50
198.21
197.95
197.75
197.63
197.44
197.31
197.13
197.08
196.89
197.08
197.38
197.36
197.43
197.58
197.73
197.86
198.05
198.34
198.54
198.85
199.02
199.19
198.97
198.77
198.49
198.23
198.05
197.95
197.77
197.60
197.45
197.48
197.61
197.63
197.73
197.79
198.05
198.24
198.38
198.69
198.91
199.05
199.18
199.34
199.14
198.98
198.71
198.63
198.38
198.12
197.90
197.82
197.78
197.67
197.76
197.87
197.89
197.98
198.16
198.45
198.57
198.82
199.03
199.26
199.37
199.22
198.84
198.73
198.57
198.33
198.19
198.08
198.02
197.84
197.83
198.06
198.11
198.17
198.46
198.68
198.86
198.92
199.20
199.44
199.43
199.02
198.96
198.83
198.59
198.35
198.24
198.06
197.94
198.03
198.11
198.23
198.41
198.68
198.80
198.93
199.10
199.45
199.32
199.13
198.95
198.80
198.61
198.38
198.26
198.13
198.01
198.04
198.23
198.32
198.45
198.70
198.86
198.99
199.18
199.31
198.97
198.88
198.80
198.55
198.46
198.34
198.08
198.13
198.24
198.40
198.54
198.74
198.93
199.04
199.17
199.12
199.00
198.71
198.68
198.60
198.40
198.27
198.15
198.15
198.19
198.45
198.67
198.74
198.89
199.06
198.95
198.78
198.73
198.56
198.54
198.44
198.25
198.26
198.35
198.54
198.64
198.63
198.91
198.93
198.87
198.80
198.60
198.51
198.31
198.20
198.79
(0.50dx2)
GU
CL 197.38
196.23
196.49
196.67
196.80
196.91
196.98
197.02
197.02
197.04
197.18
197.27
197.34
197.40
197.39
197.44
197.46
197.42
197.42
197.34
197.31
197.19
197.18
197.22
197.25
197.24
197.26
197.24
197.18
197.09
196.98
196.83
196.88
196.87
196.83
196.80
196.73
196.56
196.33
196.42
196.54
196.64
196.73
196.76
196.81
196.76
196.82
196.94
197.07
197.14
197.17
197.20
197.22
197.18
197.08
197.15
197.05
197.13
197.09
197.10
197.06
197.10
197.06
197.00
196.94
196.80
196.75
196.79
196.74
196.66
196.64
196.70
196.70
196.76
196.75
196.79
196.94
196.97
197.01
197.00
196.99
197.05
197.08
197.07
197.00
196.91
196.97
196.96
196.97
196.90
196.88
196.89
196.89
196.81
196.77
196.68
196.67
196.65
196.60
196.60
196.68
196.74
196.80
196.85
196.83
196.85
196.91
196.90
196.86
196.78
196.78
196.82196.82196.81
196.82
196.83196.84
196.84
196.83
196.77196.77
196.71
196.66
196.61196.62196.61196.61
196.58
196.63
196.73
196.80
196.80
196.79
196.77
196.76
196.71
196.64
196.67
196.70
196.68
196.68
196.68
196.64
196.56
196.56
196.56
196.59
196.58
196.56
196.54
196.56
196.45
196.43
196.47
196.51
196.50
196.49
196.40
196.30
196.35
196.33
196.33
196.38
GU
CL 196.15
GU
CL 196.00
GU
CL 196.16
GU
CL 196.29
(0.40dx2)
(0.40dx2)
(N/Adx2)
(N/Adx2)
(0.35dx2)
(0.30dx2)
(0.35dx2)
(0.35dx2)
(0.35dx2)
(0.40dx2)
1
9
5
.
6
9
1
9
5
.
7
5
1
9
5
.
8
2
1
9
5
.
9
4
1
9
5
.
9
9
1
9
6
.
1
6
1
9
6
.
1
8
1
9
6
.
1
3
1
9
6
.
1
7
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Tarmac
Tarmac
Tarmac
Tarmac
1
9
7
.5
0
1
9
7
.
5
0
1
9
7
.
5
0
1
9
8
.5
0
1
9
8
.5
0
1
9
6
.
5
0
1
9
6
.
5
0
1
9
7
.
0
0
198.00
1
9
7
.
0
0
1
9
8
.
0
0
1
9
9
.0
0
1
9
9
.
0
0
1
9
7
.
0
0
1
9
7
.0
0
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
413700E
413700E
413725E
413725E
413750E
413750E
413775E
413775E
413800E
413800E
413825E
413825E
413850E
413850E
413875E
413875E
413900E
413900E
413925E
413925E
413950E
413950E
178725N 178725N
178750N 178750N
178775N 178775N
178800N 178800N
178825N 178825N
178850N 178850N
178875N 178875N
178900N 178900N
Note: Terminated Cable
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_06
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
06
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
Empty Duct
Cover
CL 197.02
1
9
7
.3
6
1
9
7
.4
0
1
9
7
.4
4
1
9
7
.4
1
1
9
7
.4
0
1
9
7
.3
2
1
9
7
.2
2
1
9
7
.2
2
1
9
7
.1
2
1
9
7
.0
0
1
9
6
.9
4
1
9
6
.
6
6
1
9
6
.
6
3
1
9
6
.
6
3
1
9
6
.
6
0
1
9
6
.
5
5
1
9
6
.
5
4
1
9
6
.
4
9
1
9
6
.
4
8
1
9
6
.
4
6
1
9
6
.
4
4
1
9
6
.
3
9
1
9
6
.
3
5
1
9
6
.
3
0
1
9
6
.
2
5
1
9
6
.
1
2
1
9
6
.
0
0
1
9
5
.
8
8
1
9
5
.
6
9
1
9
5
.
5
0
GU
CL 197.32
GU
CL 197.39
GU
CL 197.35
GU
CL 197.22
GU
CL 197.06
GU
CL 196.90
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
6
.
7
0
1
9
6
.
6
9
1
9
6
.
6
6
1
9
6
.
6
3
1
9
6
.
5
8
1
9
6
.
5
5
1
9
6
.
5
6
1
9
6
.
5
2
1
9
6
.
4
7
1
9
6
.
4
9
1
9
6
.
3
6
1
9
6
.
3
6
1
9
6
.
2
7
1
9
6
.
1
6
1
9
5
.
9
6
1
9
5
.
8
5
1
9
5
.
6
6
1
9
5
.
4
9
Cover
CL 196.65
Cover
CL 196.25
(0
.4
0
d
)
(0
.5
0
d
)
(1
.2
0
d
)
(0
.6
0
d
)
(0
.4
0
d
)
(
0
.4
0
d
)
(
0
.7
0
d
)
(
0
.7
0
d
)
(0
.7
0
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
BT IC
CL 197.49
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B03
E 413859.141
N 178809.568
Z 197.114
196.98
197.02
197.02
197.04
197.18
197.27
197.34
197.40
197.39
197.44
197.46
197.42
197.42
197.34
197.31
197.31
197.29
197.25
197.03
197.04
197.00
197.09
197.15
197.20
197.21
197.19
197.18
197.22
197.25
197.24
197.26
197.24
197.18
197.09
196.98
196.83
196.88
196.87
196.83
196.76
196.81
196.76
196.82
196.94
197.07
197.14
197.17
197.20
197.22
197.18
197.08
197.15
197.18
197.17
197.07
197.06
196.99
196.94
196.93
196.92
196.83
196.82
196.87
196.87
196.97
197.01
197.06
197.04
197.05
197.13
197.09
197.10
197.06
197.10
197.06
197.00
196.94
196.80
196.75
196.79
196.74
196.70
196.70
196.76
196.75
196.79
196.94
196.97
197.01
197.00
196.99
197.05
197.08
197.07
197.00
197.01
196.98
196.91
196.89
196.81
196.79
196.76
196.61
196.68
196.73
196.80
196.86
196.92
196.93
196.91
196.97
196.96
196.97
196.90
196.88
196.89
196.89
196.81
196.77
196.68
196.67
196.65
196.60
196.60
196.68
196.74
196.80
196.85
196.83
196.85
196.91
196.90
196.86
196.78
196.86
196.85
196.76
196.66
196.59
196.58
196.50
196.51
196.51
196.57
196.65
196.75
196.83
196.76
196.76
196.78
196.82196.82196.81
196.82
196.83196.84
196.84
196.83
196.77196.77
196.71
196.66
196.61196.62196.61196.61
196.58
196.63
196.73
196.80
196.80
196.79
196.77
196.76
196.71
196.71
196.68
196.69
196.64
196.65
196.52
196.50
196.49
196.52
196.59
196.55
196.61
196.65
196.66
196.64
196.67
196.70
196.68
196.68
196.68
196.64
196.56
196.56
196.56
196.59
196.58
196.56
196.54
196.56
196.56
196.56
196.56
196.51
196.48
196.44
196.40
196.35
196.34
196.30
196.32
196.28
196.35
196.42
196.44
196.44
196.44
196.45
196.43
196.47
196.51
196.50
196.49
196.40
196.30
196.35
196.33
196.32
196.29
196.24
196.21
196.15
196.20
196.07
196.09
196.14
196.18
196.21
196.24
196.29
196.33
196.33
196.38
196.30
196.35
196.27
196.22
196.23
196.17
196.09
196.07
196.03
196.00
196.04
196.06
196.13
196.17
196.19
196.25
196.18
196.10
196.02
195.93
195.95
195.90
195.78
195.88
195.89
195.98
196.10
196.00
195.86
195.85
195.69
195.81
195.66
GU
CL 196.04
GU
CL 196.15
(0.35dx2)
(0.30dx2)
(0.35dx2)
(0.35dx2)
(0.35dx2)
(0.40dx2)
1
9
6
.
1
7
1
9
6
.
1
0
1
9
6
.
2
6
1
9
6
.
2
3
1
9
6
.
2
8
1
9
6
.
2
2
1
9
6
.
2
7
1
9
6
.
3
0
1
9
6
.
2
8
1
9
6
.
2
9
1
9
6
.
1
9
1
9
6
.
0
5
1
9
6
.
0
3
1
9
5
.
8
8
1
9
5
.
7
2
1
9
5
.
5
6
1
9
5
.
3
1
1
9
5
.
2
0
1
9
5
.
0
8
IC
CL 195.57
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Tarmac
Tarmac
Tarmac
1
9
6
.
5
0
1
9
6
.
5
0
1
9
7
.
0
0
1
9
7
.0
0
1
9
6
.
0
0
1
9
7
.
0
0
1
9
7
.
0
0
R
u
n
w
a
y
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
413825E
413825E
413850E
413850E
413875E
413875E
413900E
413900E
413925E
413925E
413950E
413950E
413975E
413975E
414000E
414000E
414025E
414025E
414050E
414050E
178800N 178800N
178825N 178825N
178850N 178850N
178875N 178875N
178900N 178900N
178925N 178925N
178950N 178950N
178975N 178975N
Note: Terminated Cable
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_07
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
07
011924_03
011924_05011924_04
011924_06
011924_02
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
SVYAREA
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
1
9
6
.4
3
1
9
6
.4
9
1
9
6
.5
8
1
9
6
.6
6
1
9
6
.7
3
1
9
6
.8
1
1
9
6
.9
0
1
9
7
.0
3
1
9
7
.0
8
1
9
7
.1
1
1
9
7
.1
9
1
9
7
.2
3
1
9
7
.2
6
1
9
7
.3
1
1
9
7
.3
2
1
9
7
.3
1
1
9
7
.3
7
GU
CL 196.45
GU
CL 196.50
GU
CL 196.62
GU
CL 196.76
GU
CL 196.89
GU
CL 196.97
GU
CL 197.07
GU
CL 197.11
GU
CL 197.24
GU
CL 197.28
GU
CL 197.30
(0
.7
0
d
)
(
0
.6
0
d
)
(
0
.7
0
d
)
(
0
.8
0
d
)
(
0
.7
0
d
)
(
0
.3
0
d
)
(
0
.2
0
d
)
(
0
.2
0
d
)
(
0
.7
0
d
)
(
0
.6
0
d
)
(
0
.6
0
d
)
(
0
.7
0
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
U
U
U
U
SP
SP
1
9
7
.9
5
1
9
7
.7
6
1
9
7
.5
6
1
9
7
.3
1
1
9
6
.8
9
1
9
6
.7
0
1
9
6
.5
4
1
9
9
.
7
9
1
9
9
.
5
8
1
9
9
.
3
5
1
9
9
.
0
1
1
9
8
.
6
5
1
9
8
.
3
4
1
9
8
.
0
1
1
9
7
.
6
8
1
9
7
.
4
5
1
9
7
.
1
8
1
9
7
.
0
0
1
9
6
.
8
4
1
9
6
.
7
8
1
9
6
.
6
1
1
9
6
.
4
7
1
9
6
.
5
5
196.54196.55
1
9
6
.5
6
1
9
6
.5
3
1
9
6
.
5
7
1
9
6
.6
6
1
9
6
.7
9
1
9
7
.1
8
1
9
7
.4
6
1
9
7
.7
1
1
9
7
.9
1
1
9
8
.0
0
198.60
198.51
198.31
198.20
198.22
198.34
198.46
198.57
198.69
198.79
198.88
198.83
198.97
199.01
199.67
199.52
199.37
199.17
199.03
199.00
198.90
198.79
198.77
198.67
198.67
198.55
198.56
198.53
198.35
198.24
198.13
198.07
198.11
198.24
198.28
198.30
198.34
198.56
198.59
198.58
198.53
198.69
198.82
198.95
199.14
199.36
199.37
199.57
199.71
199.41
199.29
199.18
199.08
198.93
198.78
198.61
198.45
198.43
198.44
198.44
198.39198.39
198.24
198.24
198.13
198.04
197.94
197.87
197.88
198.01
198.06
198.15
198.19
198.25
198.22
198.32
198.35
198.47
198.60
198.85
198.89198.89
198.98
199.10
199.00
198.75198.76
198.72
198.62
198.62
198.38
198.35
198.36
198.32
198.24
198.21
198.09
198.05
197.83
197.93
197.72
197.69
197.77
197.79
197.86
197.95
198.02
198.04
198.16
198.23
198.26
198.28
198.36
198.51
198.56
196.56
196.61
196.63
F
(0.60dx2)
(0.60dx2)
(0.70d)
U
UU
U
U
U
U
U
U
U
U
U
GU
CL 197.11
GU
CL 197.90
198.47
198.25
198.24
198.21
198.18
198.18
197.99
197.94
197.99
197.85
197.73
197.66
197.73
197.66
197.62
197.57
197.71
197.85
197.88
197.91
197.95
198.00
197.98
197.98
198.10
197.89
197.80
197.73
197.70
197.65
197.65
197.52
197.46
197.49
197.47
197.55
197.38
197.35
197.37
197.31
197.44
197.41
197.38
197.43
197.48
197.60
197.28
197.24
197.20
197.19
197.22
197.21
197.16
197.12
197.23
197.05
196.99
197.01
197.00
197.13
197.12
197.17
197.14
196.97
196.97
197.03
196.96
196.89
196.82
196.74
196.79
196.84
196.81
196.83
196.90
196.73
196.66
196.66
196.66
196.67
196.65
196.57
196.57
196.64
196.58
196.62
197.31
197.31
197.29
197.25
197.19
197.18
197.13
197.12
197.07
197.04
197.04
196.95
196.81
196.63
196.55
196.40
196.37
196.34
196.29
196.27
196.32
196.28
196.34
196.39
196.54
196.70
196.83
196.89
196.94
196.90
196.94
197.03
197.03
197.04
197.00
197.09
197.15
197.20
196.94
196.93
196.92
196.95
196.89
196.83
196.85
196.73
196.68
196.56
196.44
196.27
196.24
196.21
196.21
196.22
196.14
196.15
196.21
196.29
196.40
196.46
196.51
196.56
196.67
196.71
196.78
196.48
196.38
196.35
196.21
196.16
196.10
196.09
196.09
195.97
196.00
195.99
196.06
GU
CL 197.23
(0.35dx2)
(N/Adx2)
(0.35dx2)
(0.40dx2)
(0.40dx2)
(0.35dx2)
(0.40dx2)
(0.40dx2)
(0.35dx2)
(0.35dx2)
(0.40dx2)
(0
.4
0
d
)
(
0
.
6
5
d
)
(0
.4
0
d
)
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
G
r
a
v
e
l
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Tarmac
Tarmac
Tarmac
1
9
7
.
5
0
1
9
7
.5
0
1
9
7
.5
0
1
9
8
.
5
0
1
9
9
.
5
0
1
9
8
.5
0
1
9
6
.
5
0
1
9
8
.
0
0
1
9
7
.
0
0
1
9
7
.
0
0
1
9
7
.
0
0
198.0
0
1
9
8
.0
0
1
9
9
.0
0
1
9
9
.
0
0
1
9
7
.
0
0
1
9
7
.
0
0
413575E
413575E
413600E
413600E
413625E
413625E
413650E
413650E
413675E
413675E
413700E
413700E
413725E
413725E
413750E
413750E
413775E
413775E
413800E
413800E
178925N 178925N
178950N 178950N
178975N 178975N
179000N 179000N
179025N 179025N
179050N 179050N
179075N 179075N
179100N 179100N
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_08
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
08
011924_03
011924_05011924_04
011924_07
011924_02
011924_06
011924_09
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
1
9
5
.
8
8
1
9
5
.
6
9
1
9
5
.
5
0
1
9
5
.
3
7
1
9
5
.
1
9
1
9
5
.
0
3
1
9
4
.
7
9
1
9
4
.
6
8
1
9
4
.
6
0
1
9
4
.
4
5
1
9
4
.
3
6
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
8
5
1
9
5
.
6
6
1
9
5
.
4
9
1
9
5
.
3
6
1
9
5
.
1
0
1
9
4
.
9
7
1
9
4
.
7
8
1
9
4
.
6
6
1
9
4
.
6
3
1
9
4
.
5
0
1
9
4
.
3
8
GU
CL 195.17
B04
E 413864.047
N 178997.638
Z 196.763
B05
E 413823.302
N 179135.824
Z 196.308
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
197.03
197.04
196.93
196.92
196.95
196.89
196.83
196.46
196.51
196.56
196.67
196.71
196.78
196.78
196.83
196.82
196.87
196.79
196.76
196.77
196.67
196.67
196.63
196.54
196.48
196.38
196.35
196.21
196.16
196.10
196.02
196.02
195.97
196.00
195.99
196.06
196.13
196.23
196.30
196.36
196.48
196.52
196.59
196.56
196.65
196.61
196.68
196.59
196.58
196.50
196.42
196.42
196.44
196.34
196.29
196.25
196.19
196.09
196.04
195.94
195.90
195.90
195.91
195.93
196.00
196.04
196.06
196.10
196.01
196.05
196.00
195.96
195.91
195.86
195.86
195.75
195.81
195.89
195.96
196.04
196.04
196.18
196.19
196.26
196.31
196.37
196.37
196.51
196.51
196.57
196.52
196.50
196.43
196.28
196.23
196.17
196.19
196.13
196.03
195.96
195.99
195.95
195.84
195.76
195.74
195.81
195.75
195.87
195.88
195.97
195.99
195.98
196.01
195.91
195.77
195.76
195.73
195.71
195.71
195.85
195.91
195.88
195.92
195.94
196.08
196.10
196.11
196.22
196.32
196.39
196.49
196.52
196.44
196.40
196.35
196.34
196.28
196.20
196.07
196.01
195.98
196.04
195.92
195.87
195.79
195.84
195.78
195.68
195.66
195.66
195.75
195.77
195.89
195.92
195.79
195.76
195.64
195.63
195.61
195.62
195.63
195.67
195.80
195.73
195.80
195.81
195.94
195.90
195.95
196.00
196.12
196.18
196.30
196.32
196.28
196.15
196.20
196.14
196.07
195.92
195.84
195.83
195.79
195.74
195.72
195.70
195.67
195.68
195.61
195.60
195.50
195.58
195.55
195.55
195.63
195.53
195.47
195.47
195.49
195.45
195.52
195.59
195.58
195.63
195.63
195.66
195.68
195.69
195.74
195.78
195.91
195.99
196.03
196.07
196.09
196.14
196.09
196.07
196.03
195.97
195.88
195.82
195.72
195.62
195.57
195.61
195.58
195.55
195.52
195.51
195.49
195.44
195.42
195.37
195.43
195.43
195.49
195.43
195.37
195.30
195.29
195.33
195.34
195.39
195.45
195.48
195.52
195.47
195.50
195.51
195.58
195.65
195.77
195.85
195.91
195.97
196.00
196.04
195.95
195.90
195.79
195.75
195.70
195.60
195.54
195.45
195.40
195.34
195.33
195.36
195.33
195.30
195.27
195.21
195.21
195.12
195.16
195.20
195.29
195.10
195.05
195.03
195.05
195.05
195.07
195.12
195.18
195.17
195.19
195.21
195.17
195.29
195.35
195.43
195.57
195.70
195.70
195.78
195.88
195.89
195.86
195.85
195.76
195.68
195.58
195.48
195.35
195.30
195.20
195.13
195.09
195.10
195.00
195.02
195.05
194.96
194.95
194.90
194.93
194.97
195.00
195.03
194.88
194.83
194.81
194.80
194.84
194.82
194.89
194.92
194.91
194.96
195.06
195.06
195.11
195.14
195.21
195.34
195.43
195.53
195.67
195.69
195.81
195.66
195.49
195.40
195.33
195.18
195.08
195.07
195.05
194.92
194.94
194.92
194.86
194.81
194.79
194.74
194.75
194.74
194.72
194.78
194.82
195.67
195.56
194.75
194.66
194.65
194.66
194.61
194.69
194.69
194.74
194.81
194.82
194.84
194.93
195.01
195.00
195.10
195.17
195.30
195.43
195.24
195.10
195.03
194.95
194.87
194.85
194.81
194.74
194.68
194.66
194.55
194.50
194.47
194.51
194.59
194.60
194.62
194.56
194.52
194.47
194.42
194.40
194.44
194.56
194.57
194.62
194.72
194.71
194.76
194.81
194.85
194.95
194.98
194.77
194.74
194.73
194.66
194.61
194.58
194.52
194.47
194.47
194.42
194.37
194.40
194.42
194.46
194.30
194.31
194.30
194.31
194.29
194.35
194.35
194.39
194.46
194.49
194.50
194.58
194.60
194.47
194.45
194.47
194.40
194.37
194.33
194.28
194.24
194.19
194.19
194.23
194.21
194.15
194.08
194.06
194.08
194.15
194.18
194.24
194.32
194.30
194.36
194.30
194.25
194.24
194.26
194.19
194.12
194.11
194.07
194.04
194.05
193.99
193.94
194.01
194.07
194.08
194.13
194.15
194.09
194.04
193.99
193.92
193.90
193.79
193.90
193.81
193.81
1
9
5
.
2
0
1
9
5
.
0
8
Grass
Grass
Grass
Grass
Grass
Grass
Grass
GrassGrass
Grass
Grass
Grass
Grass
Grass
1
9
5
.
5
0
1
9
4
.
5
0
1
9
4
.
5
0
1
9
5
.
5
0
1
9
6
.
5
0
1
9
5
.
5
0
1
9
6
.
5
0
194.5
0
1
9
6
.
0
0
1
9
5
.
0
0
1
9
5
.0
0
1
9
6
.
0
0
1
9
7
.
0
0
1
9
5
.
0
0
1
9
6
.0
0
1
9
6
.0
0
1
9
4
.
0
0
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
413825E
413825E
413850E
413850E
413875E
413875E
413900E
413900E
413925E
413925E
413950E
413950E
413975E
413975E
414000E
414000E
414025E
414025E
414050E
414050E
178975N 178975N
179000N 179000N
179025N 179025N
179050N 179050N
179075N 179075N
179100N 179100N
179125N 179125N
179150N 179150N
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_09
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
09
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_06
011924_11
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
1
9
5
.
3
7
1
9
5
.
1
9
1
9
5
.
0
3
1
9
4
.
7
9
1
9
4
.
6
8
1
9
4
.
6
0
1
9
4
.
4
5
1
9
4
.
3
6
1
9
4
.
2
8
1
9
4
.
1
8
1
9
4
.
0
6
1
9
4
.
0
0
1
9
3
.
9
2
1
9
3
.
8
0
1
9
3
.
7
2
1
9
3
.
6
7
1
9
3
.
6
3
1
9
3
.
6
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
4
9
1
9
5
.
3
6
1
9
5
.
1
0
1
9
4
.
9
7
1
9
4
.
7
8
1
9
4
.
6
6
1
9
4
.
6
3
1
9
4
.
5
0
1
9
4
.
3
8
1
9
4
.
2
2
1
9
4
.
2
4
1
9
4
.
0
8
1
9
3
.
9
9
1
9
3
.
8
4
1
9
3
.
8
2
1
9
3
.
7
3
1
9
3
.
6
3
1
9
3
.
6
4
GU
CL 195.17
GU
CL 193.58
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
195.99
196.03
195.97
195.88
195.82
195.72
195.62
195.52
195.47
195.50
195.51
195.58
195.65
195.77
195.85
195.91
195.97
195.79
195.75
195.70
195.60
195.54
195.45
195.40
195.34
195.33
195.36
195.33
195.30
195.27
195.05
195.03
195.05
195.05
195.07
195.12
195.18
195.17
195.19
195.21
195.17
195.29
195.35
195.43
195.57
195.70
195.70
195.76
195.68
195.58
195.48
195.35
195.30
195.20
195.13
195.09
195.10
195.00
195.02
195.05
194.96
194.95
194.90
194.93
194.97
195.00
195.03
195.10
194.94
194.88
194.83
194.81
194.80
194.84
194.82
194.89
194.92
194.91
194.96
195.06
195.06
195.11
195.14
195.21
195.34
195.43
195.53
195.67
195.49
195.40
195.33
195.18
195.08
195.07
195.05
194.92
194.94
194.92
194.86
194.81
194.79
194.74
194.75
194.74
194.72
194.78
194.82
194.85
195.15
195.02
194.89
194.74
194.72
194.73
194.75
194.66
194.65
194.66
194.61
194.69
194.69
194.74
194.81
194.82
194.84
194.93
195.01
195.00
195.10
195.17
195.30
195.43
195.24
195.10
195.03
194.95
194.87
194.85
194.81
194.74
194.68
194.66
194.55
194.50
194.47
194.51
194.59
194.60
194.62
194.59
194.58
194.51
194.50
194.56
194.52
194.47
194.42
194.40
194.44
194.56
194.57
194.62
194.72
194.71
194.76
194.81
194.85
194.95
194.98
194.77
194.74
194.73
194.66
194.61
194.58
194.52
194.47
194.47
194.42
194.37
194.40
194.42
194.46
194.44
194.39
194.39
194.28
194.28
194.30
194.30
194.31
194.30
194.31
194.29
194.35
194.35
194.39
194.46
194.49
194.50
194.58
194.60
194.47
194.45
194.47
194.40
194.37
194.33
194.28
194.24
194.19
194.19
194.23
194.21
194.24
194.20
194.07
194.08
194.15
194.08
194.06
194.08
194.15
194.18
194.24
194.32
194.30
194.36
194.30
194.25
194.24
194.26
194.19
194.12
194.11
194.07
194.04
194.05
194.08
194.03
194.07
193.99
193.96
193.99
193.94
194.01
194.07
194.08
194.13
194.15
194.09
194.04
194.04
193.99
193.92
193.90
193.79
193.90
193.84
193.83193.84
193.73
193.74
193.81
193.81
193.80
193.87
193.88
193.89
193.86
193.58193.78
193.78
193.70
193.71
193.70
193.71
193.70
193.62
193.67
193.69
193.70
193.66
193.60
193.56
193.53
193.56
193.43
193.42
193.52
193.40
/
/
/
/
/
/
/
/
1
9
3
.
4
9
1
9
3
.
5
1
GU
CL 193.38
GU
CL 193.81
GU
CL 194.21
1
9
4
.
9
8
1
9
4
.
8
3
1
9
4
.
6
7
1
9
4
.
4
7
1
9
4
.
3
7
1
9
4
.
2
8
1
9
4
.
1
5
1
9
4
.
0
9
1
9
4
.
0
1
1
9
3
.
9
0
1
9
3
.
7
9
1
9
3
.
6
6
1
9
3
.
6
0
1
9
3
.
4
2
1
9
3
.
3
6
1
9
3
.
2
1
1
9
3
.
1
1
1
9
2
.
9
9
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Tarmac
Tarmac
1
9
5
.
5
0
1
9
4
.
5
0
1
9
4
.
5
0
1
9
5
.
5
0
193.50
194.5
0
1
9
5
.
0
0
1
9
5
.0
0
1
9
5
.
0
0
1
9
4
.
0
0
R
u
n
w
a
y
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
413925E
413925E
413950E
413950E
413975E
413975E
414000E
414000E
414025E
414025E
414050E
414050E
414075E
414075E
414100E
414100E
414125E
414125E
414150E
414150E
414175E
414175E
179000N 179000N
179025N 179025N
179050N 179050N
179075N 179075N
179100N 179100N
179125N 179125N
179150N 179150N
179175N 179175N
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_10
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
10
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_06
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
Point
1
9
6
.4
2
1
9
6
.3
2
1
9
6
.3
3
1
9
6
.
3
9
1
9
6
.
3
9
1
9
6
.
4
0
1
9
6
.
3
1
1
9
6
.
3
6
1
9
6
.
3
8
1
9
6
.
3
2
GU
CL 196.38
GU
CL 196.37
(0
.8
0
d
)
(
0
.
4
0
d
)
(0
.4
0
d
)
(
0
.7
0
d
)
(
0
.
5
0
d
)
(
0
.
6
0
d
)
(
0
.
6
0
d
)
(
0
.
7
0
d
)
(
0
.
6
0
d
)
(
0
.
4
0
d
)
(
0
.
4
0
d
)
(
0
.
4
0
d
)
(
0
.
6
0
d
)
(
0
.
6
0
d
)
(
0
.
5
0
d
)
(
0
.
5
0
d
)
(
0
.
5
0
d
)
B
T
B
T
B
T
B
T
BT IC
CL 196.41
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
BT IC
CL 195.82
1
9
6
.
2
3
1
9
6
.
1
1
1
9
6
.
1
1
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
1
9
6
.
0
1
1
9
5
.
8
0
1
9
5
.
8
0
1
9
5
.
6
9
1
9
5
.
6
5
1
9
5
.
5
5
1
9
5
.
5
9
1
9
5
.
4
9
1
9
5
.
4
9
1
9
5
.
3
8
1
9
5
.
3
2
1
9
5
.
2
8
1
9
5
.
2
4
1
9
5
.
1
8
1
9
5
.
1
4
1
9
5
.
0
9
1
9
5
.
0
3
1
9
5
.
0
2
1
9
4
.9
8
GU
CL 195.53
B05
E 413823.302
N 179135.824
Z 196.308
T02
E 413779.720
N 179206.895
Z 195.986
T01
E 413728.266
N 179159.686
Z 196.454
B06
E 413885.856
N 179277.623
Z 195.238
E
a
v
e
s
2
0
5
.
4
0
E
a
v
e
s
2
0
5
.
4
0
E
a
v
e
s
2
0
5
.
3
9
E
a
v
e
s
2
0
6
.
4
9
E
a
v
e
s
2
0
6
.
4
7
E
a
v
e
s
2
1
0
.
8
9
E
a
v
e
s
2
0
6
.
4
8
E
a
v
e
s
2
0
5
.
4
6
E
a
v
e
s
1
9
7
.
2
6
E
a
v
e
s
1
9
7
.
4
0
1
9
6
.
5
0
1
9
6
.
4
3
1
9
6
.
3
8
1
9
6
.
3
1
1
9
6
.
2
3
1
9
6
.
1
8
196.12
1
9
6
.
0
0
1
9
5
.
9
0
195.82
1
9
5
.
7
2
1
9
5
.
6
6
1
9
5
.
6
2
1
9
5
.
6
1
1
9
5
.
4
9
1
9
5
.
5
1
1
9
6
.
2
4
T
k
196.14T
k
1
9
6
.0
3
T
k
1
9
5
.
9
6
T
k
195.83Tk
1
9
5
.
7
6
T
k
1
9
5
.
6
8
T
k
1
9
5
.
6
6
T
k
1
9
5
.
6
6
T
k
1
9
5
.
5
0
T
k
1
9
5
.
5
5
T
k
1
9
5
.
5
5
T
k
Grass
Grass
Grass
Grass
Grass
Grass
Grass
G
r
a
s
s
Grass
Grass
Grass
G
r
a
s
s
G
r
a
s
s
G
r
a
s
s
S
t
e
p
s
C
o
b
b
l
e
s
S
t
o
n
e
s
Concrete
C
o
b
b
l
e
s
S
t
o
n
e
s
Highly
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
I
r
o
n
R
a
i
l
i
n
g
1
.
2
0
H
t
C
o
n
c
r
e
t
e
M
e
t
a
l
B
o
x
Tank
M
e
t
a
l
Barrier
P
a
v
i
n
g
S
l
a
b
Hose
Box
T
y
r
e
W
a
l
l
T
y
r
e
W
a
l
l
I
r
o
n
R
a
i
l
i
n
g
1
.
3
0
H
t
I
r
o
n
R
a
i
l
i
n
g
1
.
3
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
SV
FH
Mkr
WM
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
ER
1
9
5
.
5
6
1
9
5
.
4
8
1
9
5
.
4
9
1
9
5
.
4
8
1
9
5
.
5
1
1
9
5
.
5
1
1
9
5
.
5
2
1
9
5
.
4
8
1
9
5
.
4
7
1
9
5
.
4
7
1
9
5
.
4
7
1
9
5
.
5
0
1
9
5
.
4
7
1
9
5
.
5
1
1
9
5
.
5
1
1
9
5
.
4
9
1
9
5
.
4
7
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
4
8
195.55
195.60
195.60
195.65
195.68
195.67
195.55
195.83
195.86
196.06
196.12
196.23
196.46
196.30
195.85
195.85
195.76
195.77
195.59
195.85
195.80
195.85
195.85
195.78
195.78
195.50
195.86
196.22
196.24
196.37
196.47
196.58
196.63
196.58
196.07
196.05
196.02
195.57
195.58
195.46
195.67
195.65
195.51
194.85
194.89
194.85
194.86
194.85
195.15
195.16
195.11
195.17
195.15
195.24
194.94
195.18
195.22
195.18
195.31
195.29
195.08
195.02
195.15
195.22
195.33
195.48
195.59
195.75
195.92
195.90
196.71
196.56
196.62
196.64
196.56
196.49
196.43
196.40
196.44
196.40
196.21
196.18
196.07
196.02
195.94
195.83
195.81
195.73
195.58
195.53
195.44
195.40
195.31
195.13
195.29
195.21
195.71
195.48
195.45
195.53
195.55
195.63
195.46
195.52
195.56
195.53
195.02
195.19
195.34
195.51
195.41
195.55
195.57
195.56
195.52
195.65
195.85
195.54
195.70
195.54
195.66
195.68
195.60
195.58
195.49
195.10
195.01
195.11
195.22
195.22
194.92
194.99
194.99
194.99
194.95
195.21
195.56
195.53
195.38
195.37
195.41
195.19
195.29
195.39
195.53
195.24
194.86
195.03
195.03
194.92
195.17
195.08
195.09
195.00
195.12
194.91
195.07
195.10
195.20
195.14
195.08
195.22
195.15
195.19
195.19
195.08
195.05
195.00
194.98
195.05
194.97
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
RWP
B
B
B
B
B
B
1
9
5
.
4
9
1
9
5
.
5
6
1
9
5
.
6
8
1
9
5
.
6
5
1
9
5
.
6
9
195.76
1
9
5
.
9
0
1
9
5
.
9
7
196.0
3
1
9
6
.0
7
1
9
5
.
5
4
T
k
1
9
5
.
5
0
T
k
1
9
5
.
6
6
T
k
1
9
5
.
7
0
T
k
1
9
5
.
6
9
T
k
1
9
5
.
7
3
T
k
195.79T
k
1
9
5
.
9
6
T
k
1
9
6
.
0
0
T
k
196.0
7T
k
1
9
6
.1
1
T
k
1
9
6
.
1
4
1
9
6
.
0
9
T
k
M
H
C
L
1
9
5
.
5
6
1
9
5
.
5
2
1
9
5
.
5
2
1
9
5
.
4
9
1
9
5
.
4
7
1
9
5
.
5
0
RE
RE
GU
CL 195.44
GU
CL 195.47
/
/
/
MH
CL 195.84
MH
CL 195.75
MH
CL 195.76
MH
CL 195.85
MH
CL 195.56
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
6
3
1
9
5
.
8
3
1
9
5
.
8
7
1
9
5
.
9
9
1
9
6
.
4
4
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
6
.
5
1
1
9
6
.
0
7
1
9
6
.
0
2
1
9
6
.
0
1
1
9
6
.
0
0
1
9
5
.
9
2
1
9
5
.
8
8
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
4
1
1
9
5
.
4
7
1
9
5
.
5
1
1
9
5
.
5
4
1
9
5
.
6
7
1
9
5
.
7
7
1
9
5
.
7
2
1
9
5
.
8
1
1
9
5
.
8
9
1
9
5
.
8
4
MH
CL 195.77
1
9
5
.
4
3
1
9
5
.
4
7
1
9
5
.
4
9
1
9
5
.
4
5
1
9
5
.
5
5
1
9
5
.
5
0
1
9
5
.
5
3
1
9
6
.
0
5
1
9
6
.
0
6
1
9
5
.
9
4
1
9
5
.
9
0
1
9
5
.
8
2
1
9
5
.
7
8
1
9
5
.6
5
195.61
195.59
MH
CL 195.85
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
7
0
2
0
1
.
8
6
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
2
0
1
.
7
8
2
0
1
.
7
8
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
5
.
2
8
1
9
5
.
4
4
1
9
5
.
5
6
1
9
5
.
5
5
1
9
5
.
5
4
1
9
5
.
4
3
1
9
5
.
4
4
1
9
5
.
4
7
1
9
5
.
4
8
1
9
5
.
4
5
1
9
5
.
4
2
1
9
5
.
4
3
1
9
5
.
4
8
1
9
5
.
4
8
1
9
5
.
5
1
1
9
5
.
5
0
PO
PO
TP
TP
1
9
4
.
8
5
1
9
4
.
7
5
1
9
4
.
8
1
194.81
195.08
1
9
5
.1
4
195.14
1
9
5
.
1
7
1
9
5
.
2
4
1
9
5
.
4
1
1
9
5
.
4
8
1
9
5
.
4
6
1
9
5
.4
4
1
9
5
.4
4
1
9
5
.4
4
1
9
5
.
4
7
1
9
5
.
4
0
1
9
5
.
2
7
1
9
5
.
2
7
1
9
5
.
2
9
1
9
5
.
1
6
1
9
5
.
1
4
1
9
5
.
0
2
1
9
4
.
9
0
1
9
4
.
9
0
1
9
4
.
8
8
1
9
5
.
2
4
1
9
5
.
1
8
1
9
4
.
9
0
1
9
4
.
9
1
1
9
5
.
0
0
1
9
5
.
2
9
1
9
4
.
8
9
1
9
5
.
1
8
1
9
5
.
2
3
1
9
4
.
8
9
1
9
4
.
9
7
1
9
4
.
8
9
1
9
4
.
8
9
MH
CL 195.10
VP
MH
CL 195.17
MH
CL 195.10
G
U
C
L
1
9
4
.
8
2
GU
CL 194.76
1
9
4
.
7
9
BT IC
CL 195.83
GU
CL 195.60
1
9
5
.
5
4
1
9
5
.
7
0
1
9
5
.
6
4
1
9
5
.
5
9
1
9
5
.
6
3
1
9
5
.
7
9
1
9
5
.
7
4
1
9
5
.
6
3
1
9
5
.
6
7
/
/
/
/
1
9
5
.
4
8
1
9
5
.
4
3
MH
CL 195.45
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
4
.
8
4
1
9
5
.
1
6
1
9
5
.
3
5
1
9
5
.
4
4
1
9
4
.
8
8
1
9
4
.
8
5
1
9
5
.
0
8
1
9
5
.
0
6
1
9
5
.1
1
195.15
1
9
5
.
2
4
1
9
5
.
2
2
1
9
5
.
2
6
1
9
5
.
1
4
195.14
1
9
5
.0
6
1
9
5
.
4
3
1
9
5
.2
7
195.21
MH
CL 195.63
1
9
5
.
0
7
1
9
5
.
1
9
1
9
5
.
0
9
1
9
5
.
1
0
1
9
5
.
0
2
1
9
4
.
9
9
1
9
4
.
9
5
1
9
4
.
8
9
1
9
5
.
0
1
1
9
5
.
0
0
1
9
4
.
9
0
1
9
5
.
0
0
1
9
4
.
8
6
GU
CL 194.67
GU
CL 194.81
1
9
5
.
1
2
MH
CL 195.08
T1A
E 413684.411
N 179207.411
Z 195.597
T3
E 413784.214
N 179297.107
Z 195.218
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
196.31
196.36
196.44
196.26
196.27
196.32
196.23
196.32
196.34
196.27
196.29
196.15
196.31
196.31
196.26
196.23
196.17
196.10
196.10
196.21
196.28
196.22
196.08
196.10
196.13
195.98
196.10
196.14
196.15
196.11
196.02
196.02
195.91
195.93
196.00
196.04
196.06
196.10
196.01
195.92
195.88
196.01
195.83
195.96
196.01
196.05
196.00
195.96
195.91
195.86
195.86
195.81
195.75
195.87
195.88
195.97
195.99
196.03
195.97
195.81
195.88
195.84
195.60
195.68
195.86195.85
195.91
195.97
195.98
196.01
195.91
195.77
195.76
195.73
195.66
195.66
195.75
195.77
195.89
195.92
195.95
195.90
195.73
195.68
195.53
195.60
195.64
195.43
195.46
195.50
195.73
195.80
195.80
195.79
195.76
195.64
195.63
195.61
195.62
195.50
195.58
195.55
195.55
195.63
195.53
195.47
195.47
195.49
195.45
195.44
195.42
195.37
195.43
195.43
195.49
195.43
195.37
195.30
195.29
195.33
195.34
195.21
195.21
195.12
195.16
195.20
195.29
195.19
195.10
195.05
195.03
195.05
195.05
195.07
194.93
194.97
195.00
195.03
195.10
195.88
195.34
195.35
195.38
195.43
195.60
195.64
195.72
195.67
195.56
195.61
195.64
195.54
195.44
195.34
195.23
195.22
195.40
195.17
195.16
195.28
195.29
195.37
195.51
195.57
195.54
195.55
195.47
195.51
195.52
195.38
195.33
195.27
195.27
195.07
195.09
195.12
194.94
195.10
195.20
195.18
195.26
195.34
195.38
195.41
195.36
195.27
195.32
195.30
195.30
195.21
195.08
195.10
195.02
194.91
194.94
194.88
194.89
194.99
195.03
195.09
195.11
195.21
195.19
195.22
195.15
195.02
195.07
195.10
195.13
195.09
195.07
195.04
194.94
194.86
194.85
195.04
194.87194.87
194.86
194.86
194.93
194.94
194.95
194.99
195.01
194.74
194.79
194.87
194.89
194.76
(0.45dx2)
(0.45dx2)
Grass
Grass
Grass
Grass
Grass
Grass
Grass
C
o
n
c
r
e
t
e
C
o
n
c
r
e
t
e
C
o
n
c
r
e
t
e
C
o
n
c
r
e
t
e
C
o
n
c
r
e
t
e
C
o
n
c
r
e
t
e
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
C
o
n
c
r
e
t
e
T
a
r
m
a
c
T
a
r
m
a
c
T
a
r
m
a
c
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
P
a
v
i
n
g
S
l
a
b
s
1
9
5
.5
0
195.50
1
9
6
.
5
0
1
9
5
.
5
0
1
9
5
.5
0
1
9
5
.5
0
195.5
0
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
5
0
1
9
5
.
5
0
195.50
1
9
5
.5
0
1
9
5
.
5
0
1
9
5
.
0
0
195.00
1
9
6
.0
0
1
9
6
.
0
0
1
9
6
.
0
0
1
9
6
.0
0
1
9
6
.
0
0
1
9
6
.
0
0
1
9
5
.
0
0
1
9
5
.0
0
1
9
5
.
0
0
1
9
5
.
0
0
1
9
5
.
0
0
1
9
5
.
0
0
1
9
5
.
0
0
F
Assembly
Fire
I
r
o
n
R
a
i
l
i
n
g
1
.
2
0
H
t
I
r
o
n
R
a
i
l
i
n
g
1
.
2
0
H
t
I
r
o
n
R
a
i
l
i
n
g
1
.
2
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
C
h
a
i
n
L
i
n
k
F
e
n
c
e
1
.
8
0
H
t
B
o
x
Tank
Flammables
S
t
e
p
s
Concrete
Concrete
Concrete
I
r
o
n
R
a
i
l
i
n
g
1
.
3
0
H
t
T
y
r
e
W
a
l
l
T
y
r
e
W
a
l
l
O
v
e
r
h
e
a
d
W
i
r
e
O
v
e
r
h
e
a
d
W
i
r
e
C
o
v
e
r
F
o
r
C
a
b
l
e
s
MH
CL 195.12
413675E
413675E
413700E
413700E
413725E
413725E
413750E
413750E
413775E
413775E
413800E
413800E
413825E
413825E
413850E
413850E
413875E
413875E
413900E
413900E
413925E
413925E
179125N 179125N
179150N 179150N
179175N 179175N
179200N 179200N
179225N 179225N
179250N 179250N
179275N 179275N
179300N 179300N
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
A
S
R
D
R
D
r
a
i
n
a
g
e
C
h
a
n
n
e
l
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_11
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
11
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_06
011924_10
011924_13
011924_14
011924_12
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
UTT
Possible P/E
Concrete Slab
1
9
3
.
9
2
1
9
3
.
8
0
1
9
3
.
7
2
1
9
3
.
6
7
1
9
3
.
6
3
1
9
3
.
6
0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.
8
4
1
9
3
.
8
2
1
9
3
.
7
3
1
9
3
.
6
3
1
9
3
.
6
4
GU
CL 193.58
(
0
.9
0
d
)
(
1
.
1
0
d
)
(
0
.
9
0
d
)
(
0
.
9
0
d
)
(
0
.
8
5
d
)
(
0
.
8
0
d
)
(
1
.
1
0
d
)
(
0
.
9
0
d
)
(
0
.
3
5
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
FH
1
9
4
.
9
8
1
9
4
.9
7
1
9
4
.8
8
1
9
4
.8
0
1
9
4
.6
9
1
9
4
.5
1
1
9
4
.3
5
1
9
4
.2
6
B07
E 414013.975
N 179333.857
Z 194.226
194.87
195.05
194.97
194.88
194.79
194.73
194.59
194.42
1
9
4
.
7
9
1
9
4
.
7
3
1
9
4
.7
5 1
9
4
.7
7
1
9
4
.8
1
Tarmac
L
o
n
g
G
r
a
s
s
195.03
195.05
194.90
194.93
194.97
195.00
195.03
195.10
194.94
194.88
194.83
194.81
194.80
194.84
194.75
194.74
194.72
194.78
194.82
194.85
195.02
195.07
195.10
194.94
194.95
194.99
194.96
195.00
194.89
194.89
194.74
194.79
194.87
194.89
194.92
194.86
194.93
194.91
194.82
194.73
194.74
194.72
194.73
194.75
194.66
194.65
194.66
194.47
194.51
194.59
194.60
194.62
194.59
194.58
194.62
194.64
194.71
194.77
194.78
194.73
194.75
194.72
194.77
194.79
194.71
194.76
194.80
194.71
194.76
194.74
194.67
194.69
194.69
194.68
194.62
194.60
194.54
194.53
194.51
194.50
194.56
194.52
194.47
194.42
194.40
194.37
194.40
194.42
194.46
194.44
194.39
194.39
194.44
194.47
194.47
194.51
194.47
194.53
194.63
194.60
194.63
194.68
194.66
194.76
194.64
194.59
194.54
194.46
194.51
194.53
194.44
194.42
194.38
194.37
194.24
194.26
194.28
194.28
194.30
194.30
194.31
194.30
194.31
194.24
194.19
194.19
194.23
194.21
194.24
194.20
194.17
194.13
194.14
194.24194.24
194.33
194.30
194.31
194.36
194.40
194.36
194.45
194.51
194.58
194.46
194.45
194.38
194.27
194.26
194.21
194.22
194.21
194.15
194.13
194.08
194.06
194.07
194.07
194.08
194.15
194.08
194.06
194.08
194.15
194.11
194.07
194.04
194.05
194.08
194.03
194.07
194.05
194.06
194.03
194.04
194.14
194.16
194.19
194.20
194.24
194.25
194.26
194.32
194.31
194.19
194.18
194.14
194.10
194.13
194.14
194.11
194.07
194.05
193.90
193.94
193.99
194.00
193.96
193.99
193.96
193.99
193.94
194.01
194.07
193.99
193.92
193.90
193.79
193.90
193.84
193.83193.84
193.85
193.83
193.82
193.80
193.86
193.91
193.95
194.06
194.01
193.98
193.99
194.01
193.95
194.06
193.96193.95
193.86
193.84
193.88
193.88
193.92
193.91
193.85
193.83
193.76
193.71
193.69
193.70
193.74
193.73
193.74
193.81
193.81
193.80
193.87
193.88
193.58193.78
193.78
193.70
193.71
193.70
193.71
193.70
193.66
193.65
193.63
193.66
193.71
193.78
193.76
193.85
193.81
193.79
193.75
193.76
193.76
193.81
193.68
193.63
193.66
193.69
193.64
193.62
193.73
193.73
193.76
193.67
193.61
193.58
193.62
193.67
193.63
193.62
193.67
193.69
193.70
193.66
193.60
193.56
193.53
193.56
193.58
193.64
193.60
193.58
193.57
193.57
193.59
193.60
193.57
193.56
193.54
193.54
193.52
193.59
193.47
193.46
193.45
193.50
193.46
193.45
193.51
193.56
193.60
193.58
193.59
193.57
193.58
193.52
193.43
193.42
193.52
193.40
193.40
193.37
193.42
193.47
193.48
193.48
193.54
193.54
193.49
193.43
193.47
193.46
193.46
193.43
193.49
193.38
193.42
193.43
193.44
193.47
193.48
193.50
193.43
193.40
193.37
193.32
193.30
193.31
193.36
193.25
193.19
193.20
193.25
193.26
193.32
193.38
193.43
193.42
193.43
193.42
193.33
193.28
193.33
193.38
193.35
193.33
193.31
193.19
193.13
193.15
193.16
193.14
193.05
193.08
193.13
193.19
193.18
193.27
193.26
193.31
193.17
193.14
193.19
193.23
193.22
193.13
193.04
192.96
193.07
193.01
193.00
192.97
193.07
193.03
193.06
193.06
193.07
192.97
192.87
192.90
192.97
192.94
192.98
192.91
192.88
192.90
192.86
192.81
192.81
192.91
192.79
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.
4
9
1
9
3
.
3
5
1
9
3
.
2
4
1
9
3
.
2
6
1
9
3
.
1
1
1
9
3
.
1
8
1
9
3
.
1
0
1
9
3
.
0
5
1
9
3
.
0
7
1
9
2
.
9
7
1
9
3
.
5
1
1
9
3
.
3
6
1
9
3
.
2
9
1
9
3
.
2
8
1
9
3
.
1
4
1
9
3
.
0
8
1
9
3
.
0
3
1
9
3
.
0
0
1
9
2
.
9
9
1
9
2
.
9
4
1
9
2
.
8
6
GU
CL 193.00
GU
CL 193.38
/1
9
2
.
9
2
192.74
1
9
2
.
7
7
1
9
2
.
8
6
1
9
2
.8
4
1
9
3
.0
0
1
9
3
.0
6
1
9
3
.1
3
1
9
3
.1
6
1
9
3
.
2
5
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.4
0
193.36
193.28
193.23
193.15
193.03
1
9
3
.
0
0
1
9
2
.
8
9
1
9
2
.
8
1
1
9
2
.
7
4
1
9
2
.
8
4
1
9
3
.
6
0
1
9
3
.
4
2
1
9
3
.
3
6
1
9
3
.
2
1
1
9
3
.
1
1
1
9
2
.
9
9
1
9
3
.
0
1
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Tarmac
193.50
1
9
3
.5
0
1
9
4
.5
0
193.50
1
9
4
.
5
0
1
9
3
.5
0
194.50
1
9
5
.
0
0
195.00
1
9
4
.
0
0
1
9
4
.
0
0
1
9
4
.
0
0
194.00
1
9
3
.0
0
1
9
3
.
0
0
1
9
3
.
0
0
R
u
n
w
a
y
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
L
o
n
g
G
r
a
s
s
L
o
n
g
G
r
a
s
s
Possible Cover
413950E
413950E
413975E
413975E
414000E
414000E
414025E
414025E
414050E
414050E
414075E
414075E
414100E
414100E
414125E
414125E
414150E
414150E
414175E
414175E
179150N 179150N
179175N 179175N
179200N 179200N
179225N 179225N
179250N 179250N
179275N 179275N
179300N 179300N
179325N 179325N
Area of Small Trees
UTT
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_12
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
12
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_06
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
(
1
.
1
0
d
)
(
0
.
9
0
d
)
(
0
.
3
5
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
193.66
193.57
193.23
193.30
193.40
193.44
193.52
193.68
193.68
193.71
193.46
193.44
193.42
193.24
193.33
193.25
1
9
3
.
5
0
1
9
3
.4
8
193.41
193.46
1
9
3
.
5
5
1
9
3
.
6
2
Tarmac
Tarmac
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
193.69
193.70
193.74
193.66
193.65
193.63
193.66
193.71
193.78
193.64
193.62
193.73
193.73
193.76
193.67
193.61
193.58
193.62
193.67
193.64
193.60
193.58
193.57
193.57
193.59
193.60
193.57
193.56
193.54
193.54
193.52
193.59
193.47
193.46
193.45
193.50
193.46
193.45
193.51
193.56
193.60
193.58
193.59
193.57
193.58
193.52
193.37
193.42
193.47
193.48
193.48
193.54
193.54
193.49
193.43
193.47
193.46
193.46
193.43
193.49
193.38
193.42
193.43
193.44
193.47
193.48
193.50
193.43
193.40
193.37
193.32
193.30
193.31
193.25
193.19
193.20
193.25
193.26
193.32
193.38
193.43
193.42
193.43
193.42
193.33
193.28
193.33
193.38
193.35
193.33
193.31
193.19
193.13
193.15
193.16
193.14
193.05
193.08
193.13
193.19
193.18
193.27
193.26
193.31
193.17
193.14
193.19
193.23
193.22
193.13
193.04
192.96
193.07
193.01
193.00
192.97
193.07
193.03
193.06
193.06
193.07
192.97
192.87
192.90
192.97
192.94
192.98
192.91
192.88
192.90
192.86
192.81
192.81
192.91
192.79
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.
2
4
1
9
3
.
2
6
1
9
3
.
1
1
1
9
3
.
1
8
1
9
3
.
1
0
1
9
3
.
0
5
1
9
3
.
0
7
1
9
2
.
9
7
1
9
3
.
2
9
1
9
3
.
2
8
1
9
3
.
1
4
1
9
3
.
0
8
1
9
3
.
0
3
1
9
3
.
0
0
1
9
2
.
9
9
1
9
2
.
9
4
1
9
2
.
8
6
1
9
2
.
7
3
1
9
2
.
6
4
1
9
2
.
5
9
1
9
2
.
5
7
1
9
2
.
5
3
1
9
2
.
4
5
1
9
2
.
3
8
1
9
2
.
3
2
1
9
2
.
2
1
1
9
2
.
1
4
1
9
2
.
1
0
1
9
3
.
1
3
1
9
3
.
2
8
1
9
3
.
4
0
1
9
3
.
5
4
1
9
3
.
5
8
1
9
3
.
6
1
1
9
3
.
7
1
GU
CL 193.00
GU
CL 191.61
GU
CL 192.17
GU
CL 192.51
GU
CL 192.84
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
2
.
9
2
1
9
2
.
7
9
1
9
2
.
6
9
1
9
2
.
6
2
1
9
2
.
5
7
1
9
2
.
5
8
1
9
2
.
4
9
1
9
2
.
4
9
1
9
2
.
4
5
1
9
2
.
2
6
1
9
2
.
1
8
1
9
2
.
0
9
1
9
2
.1
2
1
9
2
.
1
9
1
9
2
.
2
7
1
9
2
.
2
6
1
9
2
.
3
9
1
9
2
.
4
0
1
9
2
.
5
0
1
9
2
.
5
3
1
9
2
.
5
6
1
9
2
.
5
9
1
9
2
.
6
9
192.74
1
9
2
.
7
7
1
9
2
.
8
6
1
9
2
.8
4
1
9
3
.0
0
1
9
3
.0
6
1
9
3
.1
3
1
9
3
.1
6
1
9
3
.
2
5
1
9
3
.
5
8
1
9
3
.
6
0
1
9
3
.
7
0
1
9
3
.
6
3
1
9
3
.
4
2
1
9
3
.
2
9
1
9
3
.
2
1
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.5
6
1
9
3
.4
9
1
9
3
.4
0
193.36
193.28
193.23
1
9
3
.1
5
1
9
3
.0
3
1
9
3
.
0
0
1
9
2
.
8
9
1
9
2
.
8
1
1
9
2
.
7
4
1
9
2
.
8
4
1
9
2
.
9
1
1
9
2
.
8
3
1
9
2
.
8
2
1
9
2
.
7
3
1
9
2
.
6
3
1
9
2
.
5
1
1
9
2
.
4
5
1
9
2
.
3
0
1
9
2
.
1
8
1
9
2
.
1
3
1
9
2
.
0
6
1
9
1
.
9
8
1
9
1
.
9
8
1
9
1
.
9
0
1
9
1
.
7
9
1
9
1
.
7
0
1
9
1
.
6
5
1
9
1
.
5
8
Grass
Tarmac
1
9
3
.5
0
193.50
1
9
3
.5
0
1
9
3
.5
0
1
9
3
.0
0
1
9
3
.
0
0
1
9
3
.
0
0
R
u
n
w
a
y
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
L
o
n
g
G
r
a
s
s
414075E
414075E
414100E
414100E
414125E
414125E
414150E
414150E
414175E
414175E
414200E
414200E
414225E
414225E
414250E
414250E
414275E
414275E
414300E
414300E
179225N 179225N
179250N 179250N
179275N 179275N
179300N 179300N
179325N 179325N
179350N 179350N
179375N 179375N
179400N 179400N
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
UTT
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_13
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
13
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_10
011924_12
011924_14
011924_06
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
(
1
.
1
0
d
)
(
0
.
9
0
d
)
(
0
.
3
5
d
)
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
193.66
193.57
193.23
193.30
193.40
193.44
193.52
193.68
193.68
193.71
193.46
193.44
193.42
193.24
193.33
193.25
1
9
3
.
5
0
1
9
3
.4
8
193.41
193.46
1
9
3
.
5
5
1
9
3
.
6
2
Tarmac
Tarmac
R
u
n
w
a
y
L
o
n
g
G
r
a
s
s
193.69
193.70
193.74
193.66
193.65
193.63
193.66
193.71
193.78
193.64
193.62
193.73
193.73
193.76
193.67
193.61
193.58
193.62
193.67
193.64
193.60
193.58
193.57
193.57
193.59
193.60
193.57
193.56
193.54
193.54
193.52
193.59
193.47
193.46
193.45
193.50
193.46
193.45
193.51
193.56
193.60
193.58
193.59
193.57
193.58
193.52
193.37
193.42
193.47
193.48
193.48
193.54
193.54
193.49
193.43
193.47
193.46
193.46
193.43
193.49
193.38
193.42
193.43
193.44
193.47
193.48
193.50
193.43
193.40
193.37
193.32
193.30
193.31
193.25
193.19
193.20
193.25
193.26
193.32
193.38
193.43
193.42
193.43
193.42
193.33
193.28
193.33
193.38
193.35
193.33
193.31
193.19
193.13
193.15
193.16
193.14
193.05
193.08
193.13
193.19
193.18
193.27
193.26
193.31
193.17
193.14
193.19
193.23
193.22
193.13
193.04
192.96
193.07
193.01
193.00
192.97
193.07
193.03
193.06
193.06
193.07
192.97
192.87
192.90
192.97
192.94
192.98
192.91
192.88
192.90
192.86
192.81
192.81
192.91
192.79
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.
2
4
1
9
3
.
2
6
1
9
3
.
1
1
1
9
3
.
1
8
1
9
3
.
1
0
1
9
3
.
0
5
1
9
3
.
0
7
1
9
2
.
9
7
1
9
3
.
2
9
1
9
3
.
2
8
1
9
3
.
1
4
1
9
3
.
0
8
1
9
3
.
0
3
1
9
3
.
0
0
1
9
2
.
9
9
1
9
2
.
9
4
1
9
2
.
8
6
1
9
2
.
7
3
1
9
2
.
6
4
1
9
2
.
5
9
1
9
2
.
5
7
1
9
2
.
5
3
1
9
2
.
4
5
1
9
2
.
3
8
1
9
2
.
3
2
1
9
2
.
2
1
1
9
2
.
1
4
1
9
2
.
1
0
1
9
3
.
1
3
1
9
3
.
2
8
1
9
3
.
4
0
1
9
3
.
5
4
1
9
3
.
5
8
1
9
3
.
6
1
1
9
3
.
7
1
GU
CL 193.00
GU
CL 191.61
GU
CL 192.17
GU
CL 192.51
GU
CL 192.84
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
2
.
9
2
1
9
2
.
7
9
1
9
2
.
6
9
1
9
2
.
6
2
1
9
2
.
5
7
1
9
2
.
5
8
1
9
2
.
4
9
1
9
2
.
4
9
1
9
2
.
4
5
1
9
2
.
2
6
1
9
2
.
1
8
1
9
2
.
0
9
1
9
2
.1
2
1
9
2
.
1
9
1
9
2
.
2
7
1
9
2
.
2
6
1
9
2
.
3
9
1
9
2
.
4
0
1
9
2
.
5
0
1
9
2
.
5
3
1
9
2
.
5
6
1
9
2
.
5
9
1
9
2
.
6
9
192.74
1
9
2
.
7
7
1
9
2
.
8
6
1
9
2
.8
4
1
9
3
.0
0
1
9
3
.0
6
1
9
3
.1
3
1
9
3
.1
6
1
9
3
.
2
5
1
9
3
.
5
8
1
9
3
.
6
0
1
9
3
.
7
0
1
9
3
.
6
3
1
9
3
.
4
2
1
9
3
.
2
9
1
9
3
.
2
1
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.5
6
1
9
3
.4
9
1
9
3
.4
0
193.36
193.28
193.23
1
9
3
.1
5
1
9
3
.0
3
1
9
3
.
0
0
1
9
2
.
8
9
1
9
2
.
8
1
1
9
2
.
7
4
1
9
2
.
8
4
1
9
2
.
9
1
1
9
2
.
8
3
1
9
2
.
8
2
1
9
2
.
7
3
1
9
2
.
6
3
1
9
2
.
5
1
1
9
2
.
4
5
1
9
2
.
3
0
1
9
2
.
1
8
1
9
2
.
1
3
1
9
2
.
0
6
1
9
1
.
9
8
1
9
1
.
9
8
1
9
1
.
9
0
1
9
1
.
7
9
1
9
1
.
7
0
1
9
1
.
6
5
1
9
1
.
5
8
Grass
Tarmac
1
9
3
.5
0
193.50
1
9
3
.5
0
1
9
3
.5
0
1
9
3
.0
0
1
9
3
.
0
0
1
9
3
.
0
0
R
u
n
w
a
y
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
L
o
n
g
G
r
a
s
s
414075E
414075E
414100E
414100E
414125E
414125E
414150E
414150E
414175E
414175E
414200E
414200E
414225E
414225E
414250E
414250E
414275E
414275E
414300E
414300E
179225N 179225N
179250N 179250N
179275N 179275N
179300N 179300N
179325N 179325N
179350N 179350N
179375N 179375N
179400N 179400N
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
UTT
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_14
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
14
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_10
011924_13
011924_12
011924_06
011924_15
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
Possible
P
/E
U
T
T
WM
193.68
193.85
193.86
193.85
193.84
194.10
194.16
194.08
194.01
194.13
194.02
193.90
193.96
193.95
193.87
193.86
193.86
193.72
193.71
193.78
193.69
193.66
193.67
193.69
193.64
193.50
193.70
193.66
193.57
192.90
193.01
193.15
193.23
193.30
193.40
193.44
193.52
193.68
193.68
193.71
193.76
193.91
194.00
194.10
194.14
194.24
193.60
193.59
193.56
193.53
193.16
192.47
192.92
193.24
193.35
193.42
193.50
193.46
193.44
193.42
193.39
193.26
193.13
192.97
192.73
193.00
193.10
193.15
193.20
193.24
193.33
193.25
193.16
193.10
193.38
192.97
192.73
193.17
193.10
193.09
193.05
193.09
1
9
4
.2
0
1
9
3
.6
5
193.66
1
9
3
.8
9
1
9
4
.1
5
1
9
4
.1
9
IC
CL 194.17
1
9
3
.8
1
1
9
3
.6
3
1
9
3
.5
9
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.8
8
1
9
3
.9
9
1
9
3
.9
5
1
9
3
.9
1
1
9
3
.8
5
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.7
8
1
9
3
.7
1
1
9
3
.6
0
1
9
3
.6
1
1
9
3
.6
0
1
9
3
.5
9
1
9
3
.6
3
1
9
3
.6
1
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.6
6
193.7
3
193.7
5
IC
CL 193.71
1
9
3
.
5
2
1
9
3
.
5
0
1
9
3
.4
8
193.41
193.46
1
9
3
.
5
5
1
9
3
.
6
2
1
9
4
.2
0
1
9
4
.1
3
1
9
4
.0
5
1
9
3
.9
3
1
9
3
.8
4
1
9
3
.
7
7
1
9
3
.
6
9
E
a
v
e
s
2
0
5
.2
1
1
9
4
.8
0
1
9
4
.6
9
1
9
4
.5
1
1
9
4
.3
5
1
9
4
.2
6
1
9
4
.1
8
1
9
4
.0
8
1
9
3
.9
2
1
9
3
.
7
5
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
A
S
R
W
IC
CL 192.84
1
9
3
.1
3
1
9
3
.1
4
1
9
3
.
1
8
1
9
3
.
2
5
1
9
3
.
1
0
193.0
8
1
9
3
.1
4
1
9
3
.
0
3
1
9
2
.
9
9
1
9
3
.
0
4
1
9
2
.
8
7
1
9
2
.6
4
192.59
1
9
2
.6
6
1
9
2
.6
5
1
9
2
.8
0
1
9
3
.
0
3
1
9
3
.1
1
1
9
3
.
1
3
1
9
3
.
2
4
1
9
3
.
2
1
1
9
3
.
1
4
1
9
3
.1
9
1
9
3
.1
5
IC
CL 192.47
IC
CL 192.46
1
9
2
.4
3
1
9
2
.4
1
192.44
1
9
2
.4
8
1
9
2
.
5
3
1
9
2
.
6
4
1
9
2
.8
3
1
9
2
.8
7
193.01
193.02
1
9
3
.
1
2
1
9
3
.
2
1
1
9
3
.
2
9
1
9
3
.3
5
1
9
3
.4
6
1
9
3
.5
9
1
9
3
.5
9
1
9
3
.
5
3
1
9
3
.5
4
1
9
3
.5
7
1
9
3
.5
8
1
9
3
.6
0
1
9
3
.5
6
1
9
3
.6
0
/
/
/
/
C
r
a
s
h
B
a
r
r
i
e
r
1
9
3
.
3
5
1
9
3
.5
8
1
9
3
.
6
0
1
9
3
.
6
8
1
9
3
.
5
2
E
a
v
e
s
2
0
5
.2
2
E
a
v
e
s
2
0
9
.6
7
E
a
v
e
s
2
0
5
.2
2
E
a
v
e
s
2
0
5
.2
3
B07
E 414013.975
N 179333.857
Z 194.226
B08
E 414061.310
N 179417.277
Z 193.138
E
a
v
e
s
2
0
5
.2
6
E
a
v
e
s
2
0
5
.2
7
E
a
v
e
s
1
9
5
.9
3
E
a
v
e
s
1
9
5
.9
2
E
a
v
e
s
1
9
6
.6
1
Grass
G
r
a
s
s
Grass
Grass
Paving Slabs
C
rash B
arrie
r
C
o
n
c
r
e
te
P
o
s
t &
W
ir
e
F
e
n
c
e
1
.2
0
H
t
P
o
s
t &
W
ir
e
F
e
n
c
e
1
.2
0
H
t
P
o
s
t &
W
ir
e
F
e
n
c
e
1
.2
0
H
t
P
o
s
t &
W
ir
e
F
e
n
c
e
1
.2
0
H
t
194.88
194.79
194.73
194.59
194.42
194.43
194.85
194.72
194.53
194.61
194.49
194.47
194.22
194.38
194.55
194.35
194.46
194.37
194.45
193.87
194.18
194.11
194.21
194.15
193.56
193.64
193.89
193.55
193.46
192.43
192.42
192.46
192.44
192.42
192.43
192.45
192.35
192.38
192.70
192.85
192.70
192.63
192.68
193.06
193.01
193.21
193.23
193.23
192.74
193.23
193.04
192.94
193.03
193.14
192.74
192.70
192.53
193.36
193.35
193.38
193.31
193.42
193.54
193.65
193.59
193.48
193.47
RWP
RWP
RWP
VP
VP
1
9
4
.7
5 1
9
4
.7
7
1
9
4
.8
1
1
9
4
.6
9
1
9
4
.6
5
1
9
4
.5
0
1
9
4
.3
2
1
9
3
.7
0
1
9
3
.8
2
1
9
3
.7
2
1
9
3
.7
5
1
9
3
.
9
0
193.92
1
9
3
.8
9
1
9
3
.6
8
1
9
3
.7
3
1
9
3
.7
3
1
9
3
.8
3
GU
CL 193.87
GU
CL 193.69
G
U
C
L
1
9
3
.5
7
H
E
R
A
S
H
E
R
A
S
H
E
R
A
S
H
E
R
A
S
1
9
4
.0
0
1
9
3
.
6
5
1
9
3
.
6
9
1
9
3
.6
0
1
9
3
.
5
6
1
9
3
.5
5
/
/
/
/
/
/
1
9
2
.5
0
1
9
2
.5
1
1
9
2
.4
7
192.43
1
9
2
.
4
7
1
9
2
.
6
5
1
9
2
.
9
0
1
9
3
.
2
5
1
9
3
.4
6
1
9
3
.3
1
1
9
3
.6
6
1
9
3
.6
1
1
9
3
.5
7
1
9
3
.4
7
1
9
3
.
1
7
192.99
1
9
2
.7
6
1
9
2
.
4
9
1
9
2
.
4
9
1
9
2
.4
7
1
9
2
.5
1
1
9
2
.4
5
1
9
2
.4
9
1
9
2
.3
6
1
9
2
.4
3
1
9
2
.3
7
1
9
2
.3
0
1
9
2
.4
0
1
9
2
.3
5
1
9
2
.3
5
1
9
2
.2
9
MH
CL 193.50
MH
CL 193.50
1
9
3
.7
0
MH
CL 193.46
MH
CL 192.92
MH
CL 193.43
MH
CL 193.48
MH
CL 193.47
MH
CL 193.47
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.3
4
1
9
3
.3
5
1
9
3
.4
4
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.4
1
1
9
3
.2
6
1
9
3
.2
0
1
9
3
.2
6
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.1
4
1
9
3
.1
6
1
9
3
.1
9
/
1
9
3
.1
5
T7
E 414010.804
N 179450.944
Z 192.283
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Tarmac
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
194.46
194.31
194.19
194.06
193.96193.95
193.86
193.76
193.81
193.68
193.63
193.59
193.47
193.46
193.43
193.49
193.38
193.33
193.07
192.09
192.04
191.94
191.97
192.01
192.06
191.82
191.53
1
9
2
.
5
9
1
9
1
.
1
5
1
9
1
.
5
6
1
9
1
.
8
3
1
9
2
.
0
3
1
9
2
.
2
9
1
9
2
.
5
0
1
9
2
.
5
8
1
9
2
.
7
5
1
9
2
.
8
7
1
9
3
.
1
3
1
9
3
.
2
8
1
9
3
.
4
0
1
9
3
.
5
4
1
9
3
.
5
8
1
9
3
.
6
1
1
9
3
.
7
1
/
/
/
/
/
/
/
/
/
/
/
/
1
9
2
.
6
9
1
9
2
.
6
2
1
9
2
.
6
3
1
9
2
.3
8
1
9
2
.
4
3
1
9
2
.
5
3
192.59
1
9
2
.
6
8
192.65
192.62
1
9
2
.
5
3
1
9
2
.4
6
1
9
2
.4
1
1
9
2
.3
5
1
9
2
.
2
9
1
9
2
.
2
6
1
9
2
.
5
3
1
9
2
.
3
5
1
9
2
.
1
6
1
9
1
.
9
1
1
9
1
.
6
8
1
9
1
.
2
6
1
9
1
.
8
8
1
9
2
.
0
3
1
9
2
.0
4
1
9
2
.0
7
1
9
2
.
1
4
1
9
2
.
1
6
1
9
2
.
1
6
1
9
2
.
1
7
1
9
2
.3
0
1
9
2
.3
4
1
9
2
.4
2
1
9
2
.4
5
1
9
2
.
3
9
1
9
2
.
5
7
1
9
2
.
1
4
SP
1
9
2
.
5
9
1
9
2
.8
4
1
9
3
.0
0
1
9
3
.0
6
1
9
3
.1
3
1
9
3
.1
6
1
9
3
.
2
5
1
9
3
.
5
8
1
9
3
.
6
0
1
9
3
.
7
0
1
9
3
.
6
3
1
9
3
.
4
2
1
9
3
.
2
9
1
9
3
.
2
1
1
9
3
.
0
4
1
9
2
.
8
5
1
9
2
.
7
1
1
9
2
.
6
4
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
3
.5
6
1
9
3
.4
9
1
9
3
.4
0
193.36
193.28
193.23
193.15
193.03
1
9
3
.
0
0
1
9
2
.
8
9
1
9
2
.
0
4
1
9
1
.
7
2
1
9
1
.
4
0
P
a
v
in
g
S
la
b
s
P
a
v
in
g
S
la
b
s
P
a
v
in
g
S
la
b
s
C
o
n
c
r
e
te
C
o
n
c
r
e
te
C
o
n
c
r
e
te
C
o
n
c
r
e
te
C
o
n
c
r
e
te
C
o
n
c
r
e
te
C
o
n
c
r
e
te
G
r
a
s
s
P
a
v
in
g
S
la
b
s
Grass
Grass
Grass
Tarmac
1
9
3
.5
0
192.5
0
1
9
2
.5
0
1
9
2
.5
0
192.5
0
1
9
3
.5
0
1
9
3
.
5
0
1
9
3
.
5
0
1
9
4
.
5
0
1
9
4
.
5
0
194.50
1
9
3
.5
0
1
9
3
.5
0
193.00
1
9
3
.
0
0
1
9
3
.
0
0
193.00
1
9
3
.
0
0
1
9
3
.
0
0
1
9
4
.0
0
1
9
4
.0
0
1
9
4
.0
0
194.0
0
1
9
3
.0
0
1
9
3
.0
0
Cra
sh B
arr
ier
0.7
0H
t
Concrete Slab
Possible Cover
Crash Barrier
H
a
n
g
a
r
Tarmac
Tarmac
MH
CL 192.97
MH
CL 193.28
Gully
413950E
413950E
413975E
413975E
414000E
414000E
414025E
414025E
414050E
414050E
414075E
414075E
414100E
414100E
414125E
414125E
414150E
414150E
414175E
414175E
414200E
414200E
179325N 179325N
179350N 179350N
179375N 179375N
179400N 179400N
179425N 179425N
179450N 179450N
179475N 179475N
179500N 179500N
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Note: Scar
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
Surveyed:
Dwg No: Rev:
Checked:
Drawn:
Job No:
Client:
Project:
Scale:
Title:
PO9 2NL
HAMPSHIRE
HAVANT
NEW LANE
8 HAYWARD BUSINESS CENTRE
TEL: 0845 456 1104
www.sumoservices.com
FAX: 0845 408 0653
Date Completed:Post Code:
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Notes:
Survey is referenced to OS Grid and Level Datum.
RevDrawn Date
Notes
SHEET LAYOUT
011924_15
011924_01
GENERAL NOTES
Utilities may continue outside of the survey area. Any paint marks outside of the area are for
investigative purposes only and may not represent the full extent of the sub-surface utilities.
Only sub-surface utility information is provided. Above ground utility information may be shown
where it assists with positional referencing.
Where logic indicates a utility exists but which cannot be positively confirmed with the
technology, an assumed route (ASR) is recorded. All Assumed Service Routes (ASR)
have been highlighted with a background yellow colour for visual enhancement.
SUMO does not procure statutory or private source utility information as part of its detection
service nor does it record any such information in a utility survey unless otherwise noted.
Statutory plans should be consulted to supplement this survey.
Vertical & Horizontal Position - Vertical position (depth) is indicative to the top of the
utility/feature and is recorded as DTS (depth to top of service) and should not be taken as
exact. Where depth information from the technology is unclear, depth is not shown. Drains
may have been detected using threading and the depth indicated could be between the top
and the bottom of the drain. Horizontal position is indicative to the centre of the utility/feature
and should not be taken as exact.
Warranty - Biodegradable paints are used to mark-out the position of the utilities. Before long
paint markings may become illegible depending on ground, weather and traffic conditions. No
warranty is given in respect of the durability of the paint markings and that they are a complete
representation of the sub-surface utilities therefore this drawing should be used as the primary
reference for the survey results.
This drawing does not provide an absolute representation of the sub-surface. Utilities have
been detected using non-invasive technologies only and the performance can be adversely
affected by ground, weather and site conditions outside of SUMO's control therefore some
utilities may be undetectable. While SUMO uses reasonable endeavours to detect all utilities it
does not warrant that 100% detection will be achieved and that approximate depth penetration
of the technologies will be greater than two metres.
Sewer and manhole details shown on this drawing have been obtained by observation and
measurement from the surface and as such cannot be guaranteed. Where precise sewer
details will be critical to the project design Sumo would recommend that entry into the chamber
be undertaken using a specialist team, appropriately qualified for confined space entry. These
teams can be supplied on request.
Irrespective of the information provided by a utility survey and statutory plans,
excavation work should be undertaken with extreme caution and in accordance with
HSE Guidelines - HSG47 Avoiding Danger from Underground Services
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
Fence
Pedestrian Railing
Crash Barrier
Heras Fence
Gulley
Lamp Post (symbol - sized)
Building (incomplete detail)
Single Double
50.00
Ground Level in metres
Spot Height
Gate
Embankment
GL 50.00
Junction Box - Elec
LP
Water Meter (symbol)
Water Valve (symbol)
WM
WV
Tree (dimensions in metres - e.g.)
Diameter at 1mh: (bole)
Spread:
Height:
Dia: 0.3
Sp: 7.5
Ht: 10.2
Species:Maple
Manhole
JB
GU
MH
Kerb top (level in metres)
Kerb channel (level in metres)
Wall
Edge Detail (level in metres)
Building Canopy
Drainage Channel
Drop Kerb (level in metres)
Footpath (level in metres)
Overhead Service Line
Invert Level in metres IL 50.00
LEGEND
Stop Cock (symbol)
Sign Post (symbol)
Fire Hydrant
Electric Pole (symbol)
Cable into Ground (symbol)
Post (symbol)
Electric Cabinet
Earth Rod (symbol)
ER
(O.60d)
Telephone Pole (symbol)
Vent Pipe (symbol)
Rodding Eye (symbol)
Rain Water Pipe (symbol)
Barrier (symbol - sized)
Bollard (symbol)
British Telecoms IC BTMH
Distribution Board (symbol)
EP
Electric Sign (symbol)
Cable TV Box (symbol)
CTV
Gas Valve (symbol)
GV
Junction Box - BT
Junction Box - Comms
OPipe Diameter in millimetres 100
Road Sign (symbol)
Survey Station (symbol)
SC
Stop Valve (symbol)SV
Sapling (symbol)
S
TP
Traffic Bollard (symbol)
Traffic Light (symbol)
VP
Feeder Pillar
B
PO
Belisha Beacon (symbol)
Direction of Flow (Drainage)
UTILITY LINETYPES
British Telecom
Cable Television
Closed Circuit Television
Communications
Drainage - Combined Water
Drainage - Foul Water
Drainage
Drainage - Storm Water
Electric
Fibre Optic
Fuel
Multiple Services Route
Oil
Oxygen
Street Lighting
Traffic Signal Loop
Unknown
Water
Empty Duct
Assumed Service Route - See GENERAL NOTES
(Using abbreviation of service and colour as above)
HV Cables
Fire Hydrant Main
UTILITY SURVEY INFORMATION
Contracted Survey Area
Previous Survey AreaPREVIOUS
SVY AREA
Area of Concern
Depth to Top of Service (metres)
Unable to Lift (cover)
Unable to Trace
Unable to Trace Further
Unable to Trace (due to blockage)
End of Trace
Soak Away
Unable to Survey UTS
UTL
Cover Level in metresCL 50.00
Inspection Cover
EC
IC
JB BT
JB COM
RS
RE
SP
SA
TOPOGRAPHIC & UTILITY DETAILS
RWP
Unknown Pipeline
Unknown Valve (symbol)
UV
Light Bollard (symbol)
LB
Telephone Box (symbol)
Flag Pole (symbol)
FP
Flat Roof Level in metres FRL 50.00
Flood Light (symbol)FL
Parapet Level in metres PL 50.00
DB
Spot Light (symbol)
Waste Pipe (symbol)
WP
FH
FP
Light in ground (symbol)
SL
Borehole (symbol)
Unknown Cable
Gas
Heating Pipes
Manhole Capped Port
CCTV Camera
Pipe into Ground (symbol)
Located by Ground Penetrating Radar GPR
ABREVIATIONS used on a PAS 128 Survey
(O.65d B2P) 0.65d = Depth in metres, B2 = Quality Level, P = Post processed GPR
15
011924_03
011924_05011924_04
011924_07
011924_02
011924_08
011924_09
011924_11
011924_10
011924_13
011924_14
011924_06
011924_12
Utilities & Topographical Details
Museum Of Science & Industry
Science Museum Group, Red Barn Gate,
21/10/2017 SN4 9LT
SOR011924
1/250 (A0 Sheet)
SF,DW,CW,TD,JHG
EJG
SF,DW,CW,TD,JHG
Wroughton, Swindon.
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
SV
YA
RE
AS
VY
AR
EA
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
SVYAREASVYAREASVYAREA
SVYAREASVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREASVY
AREA
SVYAREA
SVYAREASVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
SVYAREA
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
S
V
Y
A
R
E
A
191.71
191.77
192.02
191.97
191.82
191.87
191.96
192.01
192.08
192.09
192.04
191.94
191.97
192.01
191.53
191.18
190.91
190.58
190.37
190.03
189.91
189.83
189.86
189.87
189.92
189.89
189.92
189.92
189.91
189.68
189.56
189.45
189.62
189.59
1
9
2
.
1
4
1
9
2
.
1
0
1
9
2
.
0
4
1
9
1
.
9
1
1
9
1
.
8
7
1
9
1
.
7
7
1
9
1
.
6
8
1
9
1
.
6
3
1
9
1
.
5
3
1
9
1
.
4
7
1
9
1
.
3
7
1
9
1
.
1
8
1
9
1
.
0
7
1
9
0
.8
7
190.80
190.63
1
9
0
.
4
5
1
9
0
.
3
2
1
9
0
.
1
6
1
8
9
.
9
8
190.03
190.00
190.00
190.00
189.97
189.96
1
8
9
.
8
8
1
9
0
.
0
1
1
9
0
.
1
8
1
9
0
.
4
7
1
9
0
.
8
3
1
9
1
.
1
5
1
9
1
.
5
6
1
9
1
.
8
3
GU
CL 191.44
GU
CL 191.20
GU
CL 191.41
GU
CL 191.61
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1
9
2
.
1
8
1
9
2
.
0
9
1
9
2
.
0
2
1
9
1
.
8
8
1
9
1
.
8
9
1
9
1
.
8
0
1
9
1
.
7
2
1
9
1
.
7
3
1
9
1
.
5
7
1
9
1
.
5
0
1
9
1
.
4
3
1
9
1
.
2
3
1
9
1
.
1
0
1
9
0
.
8
1
(0.60dx2)
1
9
2
.
0
6
1
9
2
.
1
6
192.22
1
9
2
.
1
5
1
9
2
.
1
3
1
9
1
.
9
0
191.94
1
9
2
.
0
4
1
9
2
.
0
5
1
9
1
.
9
1
1
9
1
.8
5
1
9
1
.
7
0
1
9
1
.
7
2
1
9
1
.
6
9
1
9
1
.
6
7
1
9
1
.
6
8
1
9
1
.
7
2
1
9
1
.
6
1
1
9
1
.5
4
1
9
1
.
4
0
1
9
1
.
2
5
1
9
0
.
9
5
1
9
0
.4
5
1
9
0
.0
7
190.09
190.04
190.14
190.17
190.06
190.04
190.0
6
1
9
0
.
0
3
1
9
0
.
2
5
1
9
0
.
3
8
190.55
1
9
0
.6
9
1
9
2
.
4
3
1
9
2
.
5
3
192.59
1
9
2
.
6
8
192.65
192.62
1
9
2
.
5
3
1
9
2
.4
6
1
9
2
.4
1
1
9
2
.3
5
1
9
2
.
2
9
1
9
2
.
2
6
1
9
2
.
2
3
1
9
2
.
2
5
1
9
2
.
1
2
1
9
2
.
0
7
1
9
1
.
9
1
1
9
1
.
6
8
1
9
1
.
2
6
1
9
0
.
9
2
1
9
0
.
5
7
1
9
0
.
2
9
1
9
0
.
1
3
190.05
1
8
9
.
9
8
1
9
0
.0
9
1
9
0
.
7
6
1
9
1
.2
1
1
9
1
.4
0
1
9
1
.5
8
1
9
1
.
7
1
1
9
1
.
7
9
191.7
8
1
9
1
.8
2
1
9
1
.
8
8
1
9
2
.
0
3
1
9
2
.0
4
1
9
2
.0
7
1
9
2
.
1
4
1
9
2
.
1
6
1
9
2
.
1
6
1
9
2
.
1
7
1
9
2
.3
0
1
9
2
.3
4
1
9
2
.4
2
1
9
1
.7
1
1
9
1
.
7
0
1
9
1
.7
4
1
9
1
.
7
9
1
9
1
.
8
2
1
9
1
.
7
7
1
9
1
.8
2
1
9
1
.7
1
1
9
2
.0
9
1
9
2
.
0
2
1
9
2
.1
6
1
9
2
.
1
7
1
9
2
.
1
4
192.09
1
9
2
.0
3
1
9
2
.1
2
1
9
2
.
1
9
1
9
1
.
6
2
1
9
1
.
6
0
1
9
1
.
5
9
1
9
1
.
5
9
1
9
1
.
6
2
1
9
1
.6
3
1
9
1
.
7
3
1
9
1
.
8
3
1
9
1
.
9
0
1
9
1
.
8
9
1
9
2
.
0
1
1
9
2
.
1
0
1
9
0
.
7
7
1
9
0
.
8
9
1
9
1
.
1
2
1
9
1
.
2
4
1
9
1
.
3
6
1
9
1
.
4
6
191.5
0
191.5
0
1
9
1
.
5
7
1
9
1
.
6
1
1
9
1
.
6
3
1
9
1
.
1
0
1
9
0
.
7
5
1
9
0
.
4
7
1
9
0
.
2
0
1
9
0
.
0
3
1
8
9
.
8
9
1
8
9
.7
5
189.7
1
189.71
189.69
189.73
189.73
189.73
189.74
189.78
189.74
189.58
189.38189.27
189.33
189.39
189.36
1
9
1
.
6
5
1
9
1
.
5
8
1
9
1
.
5
6
1
9
1
.
4
7
1
9
1
.
3
8
1
9
1
.
3
5
1
9
1
.
2
7
1
9
1
.
2
2
1
9
1
.
1
7
1
9
1
.
1
0
1
9
1
.
0
3
1
9
0
.
8
7
1
9
0
.
7
5
1
9
0
.
5
6
190.35
1
9
0
.
1
9
1
9
0
.
0
3
1
8
9
.
9
0
189.76
189.73
Tarmac
Tarmac
Tarmac
Tarmac
Long Grass
Area of Small Trees
414150E
414150E
414175E
414175E
414200E
414200E
414225E
414225E
414250E
414250E
414275E
414275E
414300E
414300E
414325E
414325E
414350E
414350E
414375E
414375E
414400E
414400E
179400N 179400N
179425N 179425N
179450N 179450N
179475N 179475N
179500N 179500N
179525N 179525N
179550N 179550N
179575N 179575N
Long Grass
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
Area of Small Trees
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t
P
o
s
t
&
W
i
r
e
F
e
n
c
e
1
.
3
0
H
t