swimming pool certificate guide february 2020...turning end, the pool must be of such length that...

12
SWIMMING POOL CERTIFICATE GUIDE FEBRUARY 2020

Upload: others

Post on 03-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • SWIMMING POOL CERTIFICATE GUIDE

    FEBRUARY 2020

  • BUILDING DRAWING - KEY PLAN

    POOL DRAWINGS

    Longitudinal Section

    Floor Plan Cross Section

    FR 2 - SWIMMING POOLS

    1

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

  • FR 2 - SWIMMING POOLS

    2

    MEASUREMENT CRITERIA

    1.- The measurements shall be done by a certified surveyor, appointed or approved by the Member in the country in which the pool is situated.

    2.- The surveying equipment shall be a Total Station. The minimum requirements of the Total Station are the following:

    - Angle Measurement Accuracy Hz and V: 1" (0.3 mgon)

    - Distance Measurement Accuracy: 1mm + 1.5ppm

    3.- The surveyor shall provide a Calibration Certificate confirming the measurement quality of surveying equipment. The certificate will have a

    maximum validity of 1 year.

    4.- All dimensions shall be measured using a mini prism or targets.

    5.- The measurements corresponding to the FR 2.1, 2.2, 2.5, 2.6 and 2.7 shall be measured with the pool full of water. The water level can be

    lowered up to 5cm to avoid water reflection when measuring.

    6.- The measurements corresponding to the FR 2.3, 2.4, 2.14 should be measured with the empty pool.

    6.- The water temperature shall be 25º to 28 ºC.

    7.- The length of the pool FR 2.1, 2.2 shall be measured in the centre of each lane.

    8.- The width of the pool shall be measured in both ends of the pool.

    9.- The depth of the pool FR 2.3 shall be measured at least in 5 points per lane: 1 m and 6 m from each end wall and in the centre of the pool.

    10.- The verticality of the end walls FR 2.4 shall be measured in the centre of each lane. The end walls shall be vertical and form 90 degrees right

    angles. The admissible tolerance in walls verticality will be ±0.30º.

    ORTHOGONALITY OF THE POOL

    The sides of the pool shall be orthogonal and form 90 degrees right angle. The tolerance of the angle is ±0.05º.

    The 2 diagonals shall be the same length. The tolerance of the diagonal is 10mm.

    ORTHOGONALITY OF THE POOL

    Angle 1

    Angle 2

    Angle 3

    Angle 4

    Diagonal 1

    Diagonal 2

    DEGREES / m

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

  • 2.1 A2.1 B

    0.30

    FR 2.1 - LENGTH / FR 2.2 - DIMENSIONAL TOLERANCES

    0

    LANE No2.1 A (m) 2.1 B (m)

    FR 2 - SWIMMING POOLS

    FR 2.1 - 25.000 / 50.000 metres. When touch panels of Automatic Officiating Equipment are used on the starting end, or additionally on the

    turning end, the pool must be of such length that ensures the required distance of 25.000 / 50.000 metres between the two panels.

    FR 2.2 - Dimensional Tolerances

    The admissible tolerance in 50.00 m / 25.00 m swimming pools will be +0.010, -0.000 metre. Tolerances will be measured as follows:

    Wall to Wall : Minimum 50.020m / 25.020m - Maximum 50.030m / 25.030m

    Tolerances have to be consistent 0.300 metre above to 0.800 metre bellow the water surface. These measurements should be certified by a

    surveyor or other qualified official, appointed or approved by the Member in the country in which the pool is situated.

    3

    1

    2

    3

    4

    5

    6

    7

    8

    Distances between walls - Length shall be measured in the centre of the lane

    9

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

  • 2.1 A2.1 B

    0.30

    FR 2.1 - LENGTH / FR 2.2 - DIMENSIONAL TOLERANCES

    FR 2 - SWIMMING POOLS

    3.1

    0

    LANE No2.1 A (m) 2.1 B (m)

    1

    2

    3

    4

    5

    6

    7

    8

    9

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    Distances between walls - Length shall be measured in the centre of the lane

    FR 2.1 - 25.000 / 50.000 metres. When touch panels of Automatic Officiating Equipment are used on the starting end, or additionally on the

    turning end, the pool must be of such length that ensures the required distance of 25.000 / 50.000 metres between the two panels.

    FR 2.2 - Dimensional Tolerances

    The admissible tolerance in 50.00 m / 25.00 m swimming pools will be +0.010, -0.000 metre. Tolerances will be measured as follows:

    Wall to Wall : Minimum 50.020m / 25.020m - Maximum 50.030m / 25.030m

    Tolerances have to be consistent 0.300 metre above to 0.800 metre bellow the water surface. These measurements should be certified by a

    surveyor or other qualified official, appointed or approved by the Member in the country in which the pool is situated.

  • 2.1 C2.1 D

    0.302.1 E2.1 F

    0.30

    FR 2.1 - LENGTH / FR 2.2 - DIMENSIONAL TOLERANCES

    FR 2 - SWIMMING POOLS

    3.2

    0

    LANE No2.1 C (m) 2.1 D (m)

    1

    2

    3

    4

    5

    6

    7

    8

    9

    2.1 E (m) 2.1 F (m)

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    Distances between walls - Length shall be measured in the centre of the lane

    FR 2.1 - 25.000 / 50.000 metres. When touch panels of Automatic Officiating Equipment are used on the starting end, or additionally on the

    turning end, the pool must be of such length that ensures the required distance of 25.000 / 50.000 metres between the two panels.

    FR 2.2 - Dimensional Tolerances

    The admissible tolerance in 50.00 m / 25.00 m swimming pools will be +0.010, -0.000 metre. Tolerances will be measured as follows:

    Wall to Wall : Minimum 50.020m / 25.020m - Maximum 50.030m / 25.030m

    Tolerances have to be consistent 0.300 metre above to 0.800 metre bellow the water surface. These measurements should be certified by a

    surveyor or other qualified official, appointed or approved by the Member in the country in which the pool is situated.

  • 1.006.00

    2.3 A 2.3 B

    β

    FR 2.3 - DEPTH

    Minimum depth at points 2.3 A

    m

    FR 2.3 - A minimum depth of 1.35 metres, extending from 1.0 metre to at least 6.0 metres from the end wall is required for pools with starting

    block. A minimum depth of 1.0 metre is required elsewhere.

    Minimum depth elsewhere

    FR 2 - SWIMMING POOLS

    DEPTH

    WIDTH

    End wall 1. Pool Width

    WIDTH

    Width: There is no restrictions in width.

    FR 2.5: Lanes shall be at least 2.5 metres wide, with two spaces of at least 0.2 metre outside of the first and last lanes.

    m

    4

    End wall 2. Pool Width

    Minimum depth at points 2.3 B

    FR 2.4 - WALLS

    FR 2.4.1 - End walls shall be vertical, parallel and form 90º right angles to the swimming course and to the surface of the water. They shall be

    constructed of solid material, with a non slip surface extending 0.8 m below the water surface. The tolerance in walls verticality will be ±0.3º.

    Angle β - End wall 1

    0LANE No

    Angle β - End wall 2

    1 2 3 4 5 6 7 8 9

    Rest ledges

    FR 2.4.2 - REST LEDGES

    Rest ledges compliant with FR 2.4.2

    YES NO

    FR 2.4.2 - Rest ledges along the pool walls are permitted; they must be not less than1.2 metres below the water surface, and may be 0.1 metre

    to 0.15 metre wide. Both internal and external ledges are acceptable, however internal ledges are preferred.

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    N/A

  • 5.0015.00

    Min 50.020m / Max 50.030m

    9

    8

    7

    6

    5

    4

    3

    2

    1

    0

    9

    8

    7

    6

    5

    4

    3

    2

    1

    0

    BackstrokeFalse Start

    5.0015.00

    BackstrokeFalse Start

    25.00

    FR 2 - SWIMMING POOLS

    FR 2.5 - LANES / FR 2.6 LANE ROPES

    FR 2.5 - Lanes shall be at least 2.5 metres wide, with two spaces of at least 0.2 metre outside of the

    first and last lanes.

    FINA RULE COMPLIANT NONCOMPLIANT

    FR 2.6.1 - In an 8 lane pool, lane ropes shall extend the full length of the course [...]

    Lane ropes must comply with the requirements established in the FR 2.6.1.

    In a swimming pool the colour of the lane ropes should be as follows:

    • Two (2) GREEN ropes for lanes 1 and 8

    • Four (4) BLUE ropes for lanes 2, 3, 6 and 7

    • Three (3) YELLOW ropes for lanes 4 and 5

    The components extending for a distance of 5.0 m from each end of the pool shall be of RED colour.

    There shall not be more than one lane rope between each lane. The lane ropes shall be firmly

    stretched and the tensions should be 1-1,2kN .

    FR 2.6.2 - At the 15-metre mark from each end wall of the pool the components shall be distinct in

    colour from the surrounding floats.

    FR 2.6.3 - In 50 metre pools the components shall be distinct to mark 25 metres.

    Read in conjunction with the below diagram.

    5

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

  • 2.7 A

    2.7 β

    2.7 D

    2.7 C

    2.7 B

    2.7 E

    FR 2 - SWIMMING POOLS

    FR 2.7 - STARTING PLATFORMS

    FR 2.7 - Starting Platforms shall be firm and give no springing effect. The height of the platform above the water surface shall be from 0.5

    metre to 0.75 metre. The surface area shall be at least 0.5 metre x 0.5 metre and covered with a non-slip material.

    Maximum slope shall not be more than 10 degrees. The starting platform may have an adjustable setting back plate. The platform shall be

    constructed so as to permit the gripping of the platform by the swimmer in the forward start at the front and the sides; it is recommended that,

    if the thickness of the starting platform exceeds 0.04 metre, grips of at least 0.1 metre width on each side and 0.4 metre width in the front be

    cut out to 0.03 metre from the surface of the platform.Handgrips for the forward start may be installed on the sides of the starting platforms.

    Handgrips for backstroke starts shall be placed within 0.3 mete to 0.6 metre above the water surface both horizontally and vertically. They

    shall be parallel to the surface of the end wall and must not protrude beyond the end wall.

    A minimum depth of 1.35 metres, extending from 1.0 metre to at least 6.0 metres from the end wall is required for pools with starting

    blocks. Electronic read‐out boards may be installed under the blocks. Flashing is not allowed. Figures must not move during a backstrokestart.

    FR 2.7 - STARTING PLATFORM COMPLIANT NONCOMPLIANT

    The height of the platform (2.7 A) above the water surface shall be from 0.5 metre

    to 0.75 metre.

    The surface area of the platform shall be at least 0.5 metre x 0.5 metre (2.7 B x

    2.7 C ) and covered with a non-slip material.

    Maximum slope of the platform shall not be more than 10 degrees (2.7 β) .

    The platform shall be constructed so as to permit the gripping of the platform by

    the swimmer in the forward start at the front and the sides

    Handgrips for backstroke starts shall be placed within 0.3 metre to 0.6 metre

    above the water surface both horizontally and vertically (2.7 D,E). They shall be

    parallel to the surface of the end wall and must not protrude beyond the end wall.

    FR 2.8 NUMBERING

    FR 2.8 - Numbering: Each starting block must be distinctly numbered on all four

    sides, clearly visible. It is recommended that lane number 0 shall be on the

    right-hand side when facing the course from the starting end with exception of

    50m events, which may start from the opposite end. Touch panels may be

    numbered on the top part.

    FINA RULE COMPLIANT NONCOMPLIANT

    6

    NOT SUPPLIED

    NOT SUPPLIED

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

  • FR 2 - SWIMMING POOLS

    FR 2.9 - BACKSTROKE TURN INDICATORS

    FR 2.9 - Backstroke Turn Indicators: Flagged ropes shall be suspended across

    the pool, 1.8 metres above the water surface, from fixed standards placed 5.0

    metres from each end wall. Distinctive marks must be placed on both sides of the

    pool, and where possible on each lane rope, 15.0 metres from each end wall.

    FINA RULE COMPLIANT NONCOMPLIANT

    FR 2.10 - BACKSTROKE LEDGE

    Backstroge Ledge

    YES NO

    Backstroge Ledge compliant with FR 2.10

    FR 2.10 - A backstroke ledge may be used:

    - The ledge may be adjustable to 4 cm above or 4 cm below the water level.

    - The ledge is a minimum of 65 cm in length.

    - The ledge must be 8 cm in height, 2 cm at the width with 10 degrees of slope

    FR 2.11 - FALSE START ROPE

    FR 2.11 - False Start Rope may be suspended across the pool not less than 1.2

    m above the water level from fixed standards placed 15.0 m in front of the starting

    end. It shall be attached to the standards by a quick release mechanism. The

    rope must effectively cover all lanes when activated.

    FINA RULE COMPLIANT NONCOMPLIANT

    FR 2.12 - WATER CONDITIONS

    FINA RULE COMPLIANT NONCOMPLIANT

    7

    NOT SUPPLIED

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    NOT ISSUED

    N/A

    N/A

    FR 2.12.1 - Water temperature shall be 25° to 28°.

    FR 2.12.2 - Water Movement. During competition the water in the pool must be at

    a constant level, with no appreciable movement.

    In order to keep the water level, preserve the transparency of water and take into

    consideration the health regulations in force in most countries, inflow and outflow

    has to be regulated as follows:

    - 220 to 250 m3/h for 50.00 m pools

    - 150 to 180 m3/h for 33.33 m pools

    - 120 to 150 m3/h for 25.00 m pools

    In daily use, inflow and outflow has to follow the health regulation of each country

    At these turnover rates, the water distribution has to be such that no appreciable

    current or turbulence is created.

    Appreciable current or turbulence test should be done as detailed in the FR2.12.2

    The video/s and an annexe with at least 6 frames (1 frame / 10 seconds) per test

    shall be issued

  • F1

    D1

    A

    B

    A

    H1

    E1

    A B

    A

    F2

    D2

    A

    AH2

    E2

    CA

    B

    A

    FR 2 - SWIMMING POOLS

    FR 2.14 - LANE MARKINGS

    8

    FR 2.13 - LIGHTING

    FR 2.13 Lighting - Light intensity over starting platforms and turning ends shall not

    be less than 600 lux.

    A lighting report shall be issued

    COMPLIANT NONCOMPLIANTFINA RULE NOT ISSUED

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    FR 2.14 Lane Markings - shall be of a dark contrasting colour, placed on the floor of the pool in the centre of each lane.

    Width: minimum 0.2 metre, maximum 0.3 metre.

    Length: 46.0 metres for 50 metre long pools / 21.0 metres for 25 metre long pools.

    Each lane line shall end 2.0* metres from the end wall of the pool with a distinctive

    cross line 1.0 metre long and of the same width as the lane line. Target lines shall be placed on the end walls or on the touch panels, in the

    centre of each lane, of the same width as the lane lines. *Pool length tolerances must be considered.

    They shall extend without interruption from the deck edge (curb), to the floor of the pool to a maximum of 3 metres. A cross line 0.5 metre long

    shall be placed 0.3 metre below the water surface, measured to the centre point of the cross line.

    For 50m and 25m pools constructed after 1 January 2006, cross lines 0.5 metre long shall be placed at the 15 metre mark from each end of

    the pool. After October 2013 this shall be measured from the end wall to the centre point of the cross line.

    LANE No A B C D1 / D2 E1 / E2 F1 / F2 H1 / H2

    0

    1

    2

    3

    4

    5

    6

    7

    8

    9

    A maximum tolerance of ±5mm is accepted

  • FR 2 - SWIMMING POOLS

    FR 2.15 - BULKHEADS

    Bulkheads

    YES NO

    Bulkheads compliant with FR 2.15

    FR 2.15 Bulkheads – When a bulkhead serves as an end wall, it must extend the full width of the course and present a solid

    smooth, non-slippery stable vertical surface on which touch pads may be mounted extending not less than 0.8m below and 0.3m above the

    surface of the water, and must be free of hazardous openings above or below the waterline which may be penetrated by a swimmer’s

    hands, feet, toes or fingers. A bulkhead must be of a design that provides for the free movement of officials along its length without such

    movement creating any appreciable current or water turbulence.

    9

    COMMENTS

    BUILDING NAME

    POOL No

    FEDERATION

    PAGE No

    SURVEYOR

    POOL EXPERT

    FEDERATION MEMBER

    DATE

    SIGNATURE

    SIGNATURE

    SIGNATURE

    N/A

    CERTIFICATE GUIDE_SW_00Planos y vistas00G

    CERTIFICATE GUIDE_SW_01Planos y vistas1G

    CERTIFICATE GUIDE_SW_02Planos y vistas2G

    CERTIFICATE GUIDE_SW_03.1Planos y vistas3G

    CERTIFICATE GUIDE_SW_03.2Planos y vistas3GB

    CERTIFICATE GUIDE_SW_03.3Planos y vistas3GBC

    CERTIFICATE GUIDE_SW_04Planos y vistas4G

    CERTIFICATE GUIDE_SW_05Planos y vistas5G

    CERTIFICATE GUIDE_SW_06Planos y vistas6G

    CERTIFICATE GUIDE_SW_07Planos y vistas7G

    CERTIFICATE GUIDE_SW_08Planos y vistas8G

    CERTIFICATE GUIDE_SW_09Planos y vistas9G

    CERTIFICATE GUIDE_SW_03.2.pdfPlanos y vistasG3.2

    CERTIFICATE GUIDE_SW_03.1.pdfPlanos y vistasG3.1

    CERTIFICATE GUIDE_SW_03.1.pdfPlanos y vistasG3.1

    CERTIFICATE GUIDE_SW_03.2.pdfPlanos y vistasG3.2

    CERTIFICATE GUIDE_SW_03.0.pdfPlanos y vistasG3.0

    CERTIFICATE GUIDE_SW_03.1.pdfPlanos y vistasG3.1

    BUILDING NAME: DEVELOPED BY: CHECKED BY: APPROVED BY: FEDERATION: POOL No: DATE: Ang1: Ang2: Ang3: Ang4: Diag1: Diag2: 0A: 0B: 1A: 1B: 2A: 2B: 3A: 3B: 4A: 4B: 5A: 5B: 6A: 6B: 7A: 7B: 8A: 8B: 9A: 9B: WIDTH 1: WIDTH 2: DEPTH 1: DEPTH 3: DEPTH 2: EW1 LANE 0: EW1 LANE 1: EW1 LANE 2: EW1 LANE 3: EW1 LANE 4: EW1 LANE 5: EW1 LANE 6: EW1 LANE 7: EW1 LANE 8: EW1 LANE 9: EW2 LANE 0: EW2 LANE 1: EW2 LANE 2: EW2 LANE 3: EW2 LANE 4: EW2 LANE 5: EW2 LANE 6: EW2 LANE 7: EW2 LANE 8: EW2 LANE 9: RL2: OffRL1: OffL1: OffL2: OffL3: OffL4: OffSP1: OffSP3: OffSP4: OffSP5: OffSP2: OffN1: OffBT1: OffBL1: OffBL2: OffFS1: OffWT1: OffWT2: OffLI1: OffA0: A1: A2: A3: A4: A5: A6: A7: A8: A9: B0: B1: B2: B3: B4: B5: B6: B7: B8: B9: C0: C1: C2: C3: C4: C5: C6: C7: C8: C9: D0: D1: D2: D3: D4: D5: D6: D7: D8: D9: E0: E1: E2: E3: E4: E5: E6: E7: E8: E9: F0: F1: F2: F3: F4: F5: F6: F7: F8: F9: H0: H1: H2: H3: H4: H5: H6: H7: H8: H9: BH1: OffBH2: OffCOMMENTS: 0C: 0D: 0E: 0F: 1C: 1D: 1E: 1F: 2C: 2D: 2E: 2F: 3C: 3D: 3E: 3F: 4C: 4D: 4E: 4F: 5C: 5D: 5E: 5F: 6C: 6D: 6E: 6F: 7C: 7D: 7E: 7F: 8C: 8D: 8E: 8F: 9C: 9D: 9E: 9F: 0A_BULK: 0B_BULK: 1A_BULK: 1B_BULK: 2A_BULK: 2B_BULK: 3A_BULK: 3B_BULK: 4A_BULK: 4B_BULK: 5A_BULK: 5B_BULK: 6A_BULK: 6B_BULK: 7A_BULK: 7B_BULK: 8A_BULK: 8B_BULK: 9A_BULK: 9B_BULK: