swisspump pd 60hz
TRANSCRIPT
-
8/19/2019 Swisspump Pd 60hz
1/36
PD
In-line Circulating Pump60Hz
-
8/19/2019 Swisspump Pd 60hz
2/36
Approvals
René Wasmer
President of IQNet
Theodor Zahner
Managing Director SQS
CERTIFICATE IQNet and SQS
hereby certify that the organization
Certied area
Field of activity
has implemented and maintains a
Management Systemwhich fullls the requirements of the following standard
ISO 9001:2008
Scope No: 29
Issued on: 2008-12-20
Validity date: 2011-12-19
Registration Number: CH-32160
Whole company
Swiss Pump Company AGCH-3645 Thun-Gwatt
Pumps- and Controlsystems
IQNet Partners*:
AENOR Spain AFNOR Certifcation France AIB-Vinçotte International Belgium ANCE Mexico APCER Portugal CISQ Italy CQC China
CQM China CQS Czech Republic Cro Cert Croatia DQS Holding GmbH Germany DS Denmark ELOT Greece FCAV Brazil
FONDONORMA Venezuela HKQAA Hong Kong China ICONTEC Colombia IMNC Mexico Inspecta Certifcation Finland IRAM Argentina
JQA Japan KFQ Korea MSZT Hungary Nemko AS Norway NSAI Ireland PCBC Poland Quality Austria Austria RR Russia SII Israel
SIQ Slovenia SIRIM QAS International Malaysia SQS Switzerland SRAC Romania TEST St Petersburg Russia TSE Turkey YUQS Serbia
IQNet is represented i n the USA by: AFNOR Certicati on, CISQ, DQS Holding GmbH and NSAI Inc.
* The list of IQNet partners is valid at the time of issue of this certicate. Updated information is available under www.iqnet-certication.com
-
8/19/2019 Swisspump Pd 60hz
3/363
Contents
General DataIntroduction page 4
Definition of Model 4
Curves Conditions 5
Performance Ranges 5
Product range 6
Minimum inlet pressure NPSH 8
Application 9
Installation Requirement 10
Product structure and component material 11
Section Drawing PD 32 up to PD 150 11
Section Drawing PD 200 up to PD 250 12
Appendix: Base plate 13
Technical Data
PD32-**/2 14PD40-**/2 16
PD50-**/2 18
PD65-**/2 20
PD80-**/2 22
PD100-**/2 24
PD125-**/4 26
PD150-**/4 28
PD200-**/4 30PD250-**/4 32
-
8/19/2019 Swisspump Pd 60hz
4/36
G e n e r a l
D a t a
4
Introduction
English -Technical information:
The PD types are single stage in line centrifugal pumps, equipped with standard motor and
mechanical seal. Comparing with other pumps in similar structure, these pumps are less accessible tothe impurity in the liquid.
Deutsch - Technische Information:
Die PD Typen sind einstufige Inline Pumpen, ausgestattet mit einem Standard Motor und einer
Gleitringdichtung. Im Vergleich mit ähnlichen Pumpentypen weisen die PD Pumpen eine sehr gute
Resistenz gegen Schmutz im Fördermedium auf.
Français - Information technique :
Les pompes PD sont inline, centrifugat pompes avec un étage et avec un moteur standard et une
garniture mécanique. Au comparant avec autres pompes de construction similaire notre modèle estrésistant contre la boue dans le milieu.
Definition of Model
1
Inline circulation pump
Inline Zirkulationspumpe
Pompe inline circulation
2
DN of the inlet & outlet
Nennweite Saug- und Druckseite
Diamètre de la refoulement et aspiration
3
Rated head in m
Förderhöhe in m
Hauteur en m
4
Pole of the motor
Polzahl vom Motor
Pole de moteur
PD 50 - 24 / 2
1
2
3
4
-
8/19/2019 Swisspump Pd 60hz
5/365
Performance Ranges
PD
60 HZD 65 -100/2P
P 50 8 2D -9 /
PD 40 85/2-
PD 32 72/2-
P 2 5
4 / 4
D 0 - 1
PD 200-12.5/4P D 1 0 1 / 4
5 - 5 5 4PD 12 -11/
1
-
/ 4
P D
5 0
4 4
4PD 2 50-50/0 4PD 2 0-50/
PD 125 46/4-
P 32 4 2D -2 /
P D
4 -
0 / 2
0 2
P 8 8 2D 0 -7 /
D 1 00 0 2P -6 /
PD 50 20/2- P D 5 - 2 0 / 2 6
P 80 2 2D -1 /
P D 1 0 0 - 9 / 2
Curve Conditions
1- All curves are based on the measured value of motor 3x380 under the constant speed of 3500 rpm or 1750 rpm.
2- Curve tolerance in conformily with ISO 9906 Annex A.
3- Measurement is done with 20 ºC air-free water, without impurities.
4- the operation of pump shall refer to the performance region indicated by thre thickened curve to prevent oveheating ing due to too small flow rate or overload of motor due to too flow rate.
5- if the thickness and denisty of the pumped liquid id different from water, the motor power should be adjective.
-
8/19/2019 Swisspump Pd 60hz
6/36
G e n e r a l
D a t a
6
Product Ranges
1 X 220V 3 X 380V
P2 (kW) P2 (kW)1 PD 32-24/2 7 24 1.5 1.5
2 PD 32-27/2 10 27 2.2 2.2
3 PD 32-30/2 15 30 3
4 PD 32-38/2 15 38 4
5 PD 32-46/2 15 46 5.5
6 PD 32-57/2 20 57 7.5
7 PD 40-72/2 20 72 11
8 PD 40-20/2 12 20 1.5 1.5
9 PD 40-24/2 15 24 2.2 2.2
10 PD 40-28/2 15 28 3
11 PD 40-32/2 20 32 4
12 PD 40-35/2 25 35 5.5
13 PD 40-42/2 25 42 7.5
14 PD 40-65/2 25 65 11
15 PD 40-76/2 25 76 15
16 PD 40-85/2 30 85 18.5
17 PD 50-20/2 20 20 2.2 2.2
18 PD 50-27/2 20 27 3
19 PD 50-34/2 20 34 4
20 PD 50-40/2 20 40 5.5
21 PD 50-42/2 30 42 7.5
22 PD 50-51/2 35 51 11
23 PD 50-62/2 45 62 15
24 PD 50-72/2 45 72 18.5
25 PD 50-84/2 45 84 22
26 PD 50-98/2 50 98 30
27 PD 65-20/2 30 20 3
28 PD 65-25/2 30 25 4
29 PD 65-32/2 30 32 5.5
30 PD 65-38/2 35 38 7.5
31 PD 65-46/2 35 46 11
32 PD 65-55/2 35 55 1533 PD 65-60/2 50 60 18.5
34 PD 65-73/2 50 73 22
35 PD 65-85/2 60 85 30
36 PD 65-100/2 60 100 37
37 PD 80-12/2 50 12 3
38 PD 80-17/2 50 17 4
39 PD 80-20/2 60 20 5.5
40 PD 80-26/2 60 26 7.5
41 PD 80-30/2 80 30 11
42 PD 80-38/2 80 38 15
43 PD 80-47/2 80 47 18.5
44 PD 80-50/2 100 50 22
45 PD 80-65/2 100 65 30
Voltage (V)ModelNO.
Q
(m�/h)
H
(m)
n
(r/min)
3500
-
8/19/2019 Swisspump Pd 60hz
7/367
Product Ranges
1 X 220V 3 X 380V
P2 (kW) P2 (kW)46 PD 80-78/2 100 78 37
47 PD 100-11/2 50 11 3
48 PD 100-15/2 60 15 4
49 PD 100-17/2 80 17 5.5
50 PD 100-22/2 80 22 7.5
51 PD 100-25/2 100 25 11
52 PD 100-32/2 100 32 15
53 PD 100-34/2 120 34 18.5
54 PD 100-38/2 120 38 22
55 PD 100-52/2 130 52 30
56 PD 100-60/2 130 60 37
57 PD 125-11/4 120 11 5.5
58 PD 125-14/4 120 14 7.5
59 PD 125-20/4 120 20 11
60 PD 125-24/4 120 24 15
61 PD 125-28/4 140 28 18.5
62 PD 125-32/4 150 32 22
63 PD 125-38/4 150 38 30
64 PD 125-40/4 37
65 PD 125-46/4 45
66 PD 150-15/4 11
67 PD 150-18/4 15
68 PD 150-20/4 18.5
69 PD 150-24/4 22
70 PD 150-32/4 30
71 PD 150-36/4 37
72 PD 150-44/4 45
73 PD 200-12.5/4 22
74 PD 200-20/4 30
75 PD 200-23/4 37
76 PD 200-27/4 45
77 PD 200-32/4 5578 PD 200-43/4 75
79 PD 200-50/4 90
80 PD 250-14/4 37
81 PD 250-17/4 45
82 PD 250-20/4 55
83 PD 250-26/4 75
84 PD 250-32/4 90
85 PD 250-40/4 110
86 PD 250-50/4 132
n
(r/min)
Voltage (V)
1750
NO. ModelQ
(m�/h)
H
(m)
-
8/19/2019 Swisspump Pd 60hz
8/36
G e n e r a l
D a t a
8
Minimum inlet pressure NPSH
The following formula can be used for calculation of minimum inlet pressure:
H= Pb X 10.2 - NPSH - Hf - Hv - Hs
H - maximum suction head (m)Pd - atmosphere pressure (bar)
In a closed system, Pd means system pressure (bar)
NPSH - Net positive suction head (m)
It can read out from the point of possible max. flow rat shown on NPSH curve.
Hf - Pipeline loss at the inlet (m)
it is in accordance with pipeline possible max. flow.
Hv - Steam pressure (m)
It depends on liquid temperature and steam pressure value.
Hs - Safety margin (m)
Minimum 0.5m delivery head.If the calculated result H is negative, a delivery head of Min. inlet pressure is necessary.
Note: Normally, the above calculation will not be done. H is calculated in the following conditions:
1. The liquid temperature is comparatively higher.
2. Liquid flow exceeds rated value.
3. Suction stroke is comparatively large or inlet pipeline long.
4. System pressure is too low.
5. Bad inlet condition.
-
8/19/2019 Swisspump Pd 60hz
9/369
Application
The pumps are applicable for clean, attenuate, non-corrosive, non-flammable, and non-explosive liquid which
shall not contain any solid grain and fiber that might damage the pump mechanically or chemically. The detailed
requirements on the liquid are in table 3. If the liquid viscosity or density is beyond the required level, the perfor-mance curves will descend and energy consumption will be increased.
Liquid temperature: -15°C ~ 110°C
Max. Pressure: Normal type: PN12 bar; special type: PN16 bar.
Max
temperature
water supply
for boiler
water supply
for region
condensate
water
alkalescent
water
cooling orlubricant
process
Alcoholised
compound
Hydrogen
peroxide
≤ 60°C
20%
Diesel oil
Coal oil ≤ 60°C
Oxidant
PD pumps can be used in chemical
industry, pharmaceutical industry, food
processing and so on.
•Liquid feeding
•System pressure boosting
•Mixed circuit circulation pump
< 50°C Tiny quantity rime may
impair the shaft seal
< 50°C
< 50°C Tiny quantity rime may
impair the shaft seal
30% brine
(NaCl, CaCl2
solution)
≤ 60°C
Addictive and little impuritymay impair the shaft seal
Weak alkalescence
Organic
solvent
< 110°C
Weak alkalescence
soft water
Liquid requirement Application
< 90°C
< 110°CPD Pumps are applicable for urban
water supply, industrial water, cooling
system, and cold & hot water for
regional heat supply system:
•Main circulation pump
•Mixed circuit pump
•Boiler mixed-flow pump
•Gas-fired freezer pump
•Filter pump
•Constant pressure system pump
•Urban hot water circulation
-15°C 110°C
Liquid
Water
Imflammable liquid
Underground
Water
< 90°C
Cooling
liquid
Hydro carbon
antifreeze
sea water
-
8/19/2019 Swisspump Pd 60hz
10/36
G e n e r a l
D a t a
10
Installation Requirements
Some detailed requirement of installation is as below, the concrete request is as follows:
1- If the system pipeline can support the pumps, pumps with 2.2kW motor power (including power is higher than
2.2kW) can be hung in line, if the system pipeline cannot support the pumps or the pump motor power is higherthan 2.2kW, the pumps must be installed in brackets or base.
2- Pumps with motor power lower than 2.2kw (including 2.2kW) can be installed horizontally or vertically to pipe
line. Pumps with motor power higher than 2.2kW, can only be installed vertically to the pipeline.
3- The pump installation shall not allow the system pipeline tensile force to be transferred to the pump body.
4- The pump should be installed in the environment with sufficient cooling and the cooling air shall not be
above 40°C.
5- If the pumps are installed outdoors, there should be covers to protect electric components from water.
6- For the convenience of maintenance, there should be enough space above and below the pumps, minimum
300mm shallbe kept for pumps with motor lower than 5.5kW, and minimum 1000mm for pumps with motor power higher
than 5.5kW (including 5.5kW) .
7- To prevent noises and vibration and ensure the best operation, anti- vibration base shall be used in installation.
Generally, centrally base with the weight equal or bigger than 1.5 X pump weight shall be adopted.
8- Pumps with bases or without bases are both available for customer’s requirements.
2-A 2-B 2-C
For power > 2.2kW For power 5.5kW≥
For power < 5.5kWFor power 2.2kW≤
-
8/19/2019 Swisspump Pd 60hz
11/3611
Product Structure and Component Material
Motor and pumps can be separated, standard motors and mechanical seals are provided.
The motors are entirely close and air cooling type standard motors. Its major dimensions are in conformity with GB
standard.The pump body is equal to a section of pipeline. While in maintenance, blind flange can be used to seal the pump
covers which enable the normal operation of pumps.
The flange connection dimensions are in conformity with the related provisions PN16 in GB/T17241.6
or ISO7005-2/DIN 2501.
Pump body is installed with replaceable wear ring which is able to minimize the leakage to the lowest amount.
The inlet and outlet diameters are inconformity with related standard dimensions.
The bracket is to connect motor and the pump. “O” ring or flat rubber circle is used to seal the bracket and the pump.
No. Parts Material
1 Pump body HT200
2 Impeller HT200/ 0Cr18Ni9
3 Pump head HT200
4 Mechanical seal Carbon/ Silicon Carbide
5 Guard Plate 0Cr18Ni9
6 Shaft 2Cr13
7 Air release bolt 0Cr18Ni9
8 Ring NBR
9 Plug 0Cr18Ni9
Section Drawing PD 32 up to PD 150
-
8/19/2019 Swisspump Pd 60hz
12/36
G e n e r a l
D a t a
12
No. Parts Material1 Pump body HT200
2 Impeller HT200/ 0Cr18Ni9
3 Pump head HT200
4 Mechanical seal Carbon/ Silicon Carbide
5 Guard Plate 0Cr18Ni9
6 Shaft 2Cr13
7 Air release bolt Brass H628 O Ring NBR
9 Plug 0Cr18Ni9
10 Coupling Carbon Steel
Section Drawing PD 200 up to PD 250
-
8/19/2019 Swisspump Pd 60hz
13/3613
Appendix: Base Plate
No. Product Model Base Plate Type No. Product Model Base Plate Type No. Product Model Base Plate Type
1 PD 32-24/2 A 25 PD 50-84/2 A 49 PD 100-17/2 A
2 PD 32-27/2 A 26 PD 50-98/2 A 50 PD 100-22/2 A
3 PD 32-30/2 A 27 PD 65-20/2 A 51 PD 100-25/2 A
4 PD 32-38/2 A 28 PD 65-25/2 A 52 PD 100-32/2 A
5 PD 32-46/2 A 29 PD 65-32/2 A 53 PD 100-34/2 A
6 PD 32-57/2 A 30 PD 65-38/2 A 54 PD 100-38/2 A
7 PD 32-72/2 A 31 PD 65-46/2 A 55 PD 100-52/2 A
8 PD 40-20/2 A 32 PD 65-55/2 A 56 PD 100-60/2 A9 PD 40-24/2 A 33 PD 65-60/2 A 57 PD 125-11/4 A
10 PD 40-28/2 A 34 PD 65-73/2 A 58 PD 125-14/4 A
11 PD 40-32/2 A 35 PD 65-85/2 A 59 PD 125-20/4 A
12 PD 40-35/2 A 36 PD 65-100/2 A 60 PD 125-24/4 A
13 PD 40-42/2 A 37 PD 80-12/2 A 61 PD 125-28/4 A
14 PD 40-65/2 A 38 PD 80-17/2 A 62 PD 125-32/4 A
15 PD 40-76/2 A 39 PD 80-20/2 A 63 PD 125-38/4 A
16 PD 40-85/2 A 40 PD 80-26/2 A 64 PD 125-40/4 A
17 PD 50-20/2 A 41 PD 80-30/2 A 65 PD 125-46/4 A
18 PD 50-27/2 A 42 PD 80-38/2 A 66 PD 150-15/4 A
19 PD 50-34/2 A 43 PD 80-47/2 A 67 PD 150-18/4 A
20 PD 50-40/2 A 44 PD 80-50/2 A 68 PD 150-20/4 A
21 PD 50-42/2 A 45 PD 80-65/2 A 69 PD 150-24/4 A22 PD 50-51/2 A 46 PD 80-78/2 A 70 PD 150-32/4 A
23 PD 50-62/2 A 47 PD 100-11/2 A 71 PD 150-36/4 A
24 PD 50-72/2 A 48 PD 100-15/2 A 72 PD 150-44/4 A
Remark: Base plate is optional part, need to note when order.
-
8/19/2019 Swisspump Pd 60hz
14/36
T e c h n i c a l
D a t a
14
PD32-**/2
PD 32
-
8/19/2019 Swisspump Pd 60hz
15/3615
PD32-**/2
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD 32-24/2 140 190 155 115 115 144 100 166 556 340 170 56
PD 32-27/2 140 190 155 115 115 144 100 166 556 340 170 59
PD 32-30/2 160 197 165 115 115 144 100 185 600 340 170 68
PD 32-38/2 160 230 188 129 129 144 100 185 620 440 220 79
PD 32-46/2 200 260 208 129 129 144 100 213 743 440 220 104
PD 32-57/2 200 260 208 129 129 144 100 213 743 440 220 107
PD 32-72/2 350 330 255 129 129 144 100 262 852 440 220 167
Model
(mm) weight
(KG))
Model (Kw) Q(m³/h) 4 7 8 10 12 15 20 25
PD 32-24/2 1.5 24.5 24 23 21
PD 32-27/2 2.2 29 28 27 26 23
PD 32-30/2 3 35 34 32 30 23
PD 32-38/2 4 43 42 40 38 33
PD 32-46/2 5.5 49 49 48 46 44PD 32-57/2 7.5 62 62 61 59 57 53
PD 32-72/2 11 77 77 76 75 72 67
H
(m)
Size, weight, and volume for transportation
Performance Table
-
8/19/2019 Swisspump Pd 60hz
16/36
T e c h n i c a l
D a t a
16
PD40-**/2
PD 40
-
8/19/2019 Swisspump Pd 60hz
17/3617
PD40-**/2
Size, weight, and volume for transportation
Performance TableModel (Kw) Q(m³/h) 5 10 12 15 20 25 30
PD 40-20/2 1.5 23 22 20 18
PD 40-24/2 2.2 27 26 24 18
PD 40-28/2 3 35 33 28 20
PD 40-32/2 4 34 34 33 32 30
PD 40-35/2 5.5 38 38 37 36 35 33
PD 40-42/2 7.5 45 45 44 43 42 40
PD 40-65/2 11 69 69 68 67 65 63
PD 40-76/2 15 79 79 78 77 76 73
PD 40-85/2 18.5 91 91 90 89 87 85
H
(m)
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD 40-20/2 140 190 155 97 95 120 68 160 518 320 160 46PD 40-24/2 140 190 155 97 95 120 68 160 518 320 160 53
PD 40-28/2 160 197 165 97 95 120 68 178 561 320 160 70
PD 40-32/2 160 230 188 138 128 144 110 185 630 440 220 77
PD 40-35/2 200 260 208 138 128 144 110 213 753 440 220 106
PD 40-42/2 200 260 208 138 128 144 110 213 753 440 220 110
PD 40-65/2 350 330 255 138 128 144 110 262 862 440 220 167
PD 40-76/2 350 330 255 140 138 144 110 262 862 440 220 178
PD 40-85/2 350 330 255 140 138 144 110 262 922 440 220 196
Model(mm) Weight
(KG)
-
8/19/2019 Swisspump Pd 60hz
18/36
T e c h n i c a l
D a t a
18
PD50-**/2
PD 50
-
8/19/2019 Swisspump Pd 60hz
19/3619
PD50-**/2
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD50-20/2 140 190 155 117 115 144 115 153 558 340 170 65
PD50-27/2 160 197 165 117 115 144 115 172 602 340 170 74
PD50-34/2 160 230 188 129 115 144 115 172 622 340 170 79
PD50-40/2 200 260 208 129 115 144 115 197 742 340 170 103
PD50-42/2 200 260 208 171 158 144 115 197 742 440 220 118
PD50-51/2 350 330 255 171 158 144 115 250 855 440 220 181
PD50-62/2 350 330 255 171 158 144 115 250 855 440 220 191
PD50-72/2 350 330 255 171 158 144 115 250 915 440 220 209
PD50-84/2 350 360 285 171 158 144 115 250 955 440 220 245
PD50-98/2 400 400 310 171 158 144 115 250 1025 440 220 296
Weight
(KG)Model
(mm)
PD50-20/2 21 20.5 20.3 20 18.5
PD50-27/2 31 30 28.8 27 26
PD50-34/2 37 36.2 35.3 34 32.7
PD50-40/2 41.5 41.2 41 40 39
PD50-42/2 45.5 44 43 42 40 39
PD50-51/2 54 53.5 52.5 52 51 50 47
PD50-62/2 66.5 66.6 66 65 63 62 59 56
PD50-72/2 77 77 77.2 76 73 72 71 69
PD50-84/2 88 88 88 87 85 84 83 82
PD50-98/2 99.1 99.4 99.6 99 98.5 98
5.5 H
7.5 (m)
11
15
18.5
22
30
50 55
2.2
3
4
30 35 40 4510 15 20 25Model (Kw) Q(m³/h) 5
-
8/19/2019 Swisspump Pd 60hz
20/36
T e c h n i c a l
D a t a
20
PD65-**/2
PD 65
-
8/19/2019 Swisspump Pd 60hz
21/3621
PD65-**/2
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD65-20/2 160 197 165 142 124 144 105 191 611 360 180 74
PD65-25/2 160 230 188 142 124 144 105 191 631 360 180 81
PD65-32/2 200 260 208 142 124 144 105 213 748 360 180 105
PD65-38/2 200 260 208 142 124 144 105 213 748 360 180 108
PD65-46/2 350 330 255 179 167 144 125 262 877 475 238 183
PD65-55/2 350 330 255 179 167 144 125 262 877 475 238 193
PD65-60/2 350 330 255 179 167 144 125 262 937 475 238 210
PD65-73/2 350 330 255 179 167 144 125 262 933 475 238 248
PD65-85/2 400 400 310 179 167 144 125 262 1047 475 238 309
PD65-100/2 400 400 310 179 167 144 125 262 1047 475 238 328
Model(mm) Weight
(KG)
PD65-20/2 3 22.2 22 20 18 14.3
PD65-25/2 4 28 27 25 24 21
PD65-32/2 5.5 35 33.5 32 31 29.5
PD65-38/2 7.5 39.5 38.7 38.5 38 36 31.5
PD65-46/2 11 48 47 46.5 46 45 44
PD65-55/2 15 57.3 56.5 56.2 55 54 52
PD65-60/2 18.5 64 63.8 62 61.8 60.5 60 56PD65-73/2 22 78 77 76.5 76 75.5 73 71
PD65-85/2 30 87.8 88 90 90.5 89.5 88.5 85 83
PD65-100/2 37 107.6 106 105 104 103 102 100 99.5
Model (Kw) Q(m³/h) 10
H
(m)
50 60 7020 30 35 40
-
8/19/2019 Swisspump Pd 60hz
22/36
T e c h n i c a l
D a t a
22
PD80-**/2
PD 80
-
8/19/2019 Swisspump Pd 60hz
23/3623
PD80-**/2
Size, weight, and volume for transportation
Performance Table
B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD80-12/2 197 165 142 124 160 97 219 631 450 225 84
PD80-17/2 230 188 142 124 160 97 219 651 450 225 91
PD80-20/2 260 210 142 124 160 97 241 768 450 225 114
PD80-26/2 260 210 142 124 160 97 241 768 450 225 117
PD80-30/2 330 255 182 163 144 115 279 884 500 250 194
PD80-38/2 330 255 182 163 144 115 279 884 500 250 204
PD80-47/2 330 255 182 163 144 115 279 944 500 250 222
PD80-50/2 330 255 182 163 144 115 279 984 500 250 258
PD80-65/2 400 310 182 163 144 115 279 1054 500 250 319
PD80-78/2 400 310 182 163 144 115 279 1054 500 250 338
Model(mm) Weight
(KG)
PD80-12/2 15.2 15.6 15 14.5 13.5 12 10.5
PD80-17/2 18.5 19 18.6 18.1 17.5 17 15.8 13.5
PD80-20/2 22.5 23 23.6 22.8 22 21.2 20 19 16
PD80-26/2 30.3 30.6 30.4 30 29 28 26 25 21
PD80-30/2 36.8 36.8 36.7 35.8 35.3 34.2 33.1 32.4 30 27.8 23.5 20.5
PD80-38/2 42.9 43 43.1 43 42.6 42 40.5 39.5 38 36.2 32.3 32
PD80-47/2 51.3 51.5 50.9 50.5 50.3 50.2 50 49.4 47 46.5 44.6 42.1
PD80-50/2 54.7 55.5 55.2 55 54.8 54.3 54.3 53.4 51.6 50.5 50 48.5
PD80-65/2 70.9 71.4 72 71.9 71.6 71 70.3 69.3 65 64.3
PD80-78/2 81.9 82.8 82.9 82.5 82.4 81.1 80 78 77
Model (Kw) Q(m³/h)
22
50 60 70 80 90 100 11030 40
37
5 10
30
3
H
(m)
4
5.5
7.5
11
15
18.5
20
-
8/19/2019 Swisspump Pd 60hz
24/36
T e c h n i c a l
D a t a
24
PD100-**/2
PD 100
-
8/19/2019 Swisspump Pd 60hz
25/3625
PD100-**/2
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD 100-11/2 160 215 190 134 101 160 105 190 630 450 225 65
PD 100-15/2 160 215 190 134 101 160 105 190 630 450 225 83
PD 100-17/2 200 260 205 150 117 144 140 215 785 500 250 119
PD 100-22/2 200 260 205 150 117 144 140 215 785 500 250 122
PD 100-25/2 350 350 245 181 152 230 140 270 900 550 275 197
PD 100-32/2 350 350 265 181 152 230 140 270 900 550 275 207
PD 100-34/2 350 350 265 181 152 230 140 270 960 550 275 224
PD 100-38/2 350 350 280 181 152 230 140 270 1000 550 275 260
PD 100-52/2 400 400 305 181 152 230 140 270 1070 550 275 318
PD 100-60/2 400 400 305 181 152 230 140 270 1070 550 275 337
Model(mm) Weight
(KG)
Model (Kw) Q(m³/h) 10 20 40 50 60 80 100 120 130 140
PD 100-11/2 3 17.2 17.1 14.6 11 9 6.3
PD 100-15/2 4 20.7 20.8 17.9 15 8
PD 100-17/2 5.5 21.1 20.8 20 19.2 17 13
PD 100-22/2 7.5 25.6 25.4 24.4 23.5 22 18.4
PD 100-25/2 11 29.1 29.5 28.8 27.8 26.6 25 19.8 19.4
PD 100-32/2 15 36 36.6 35.6 34.6 33.5 32 28.9 25.5
PD 100-34/2 18.5 39.4 39.4 39.5 39 37.8 36.2 34 33.4 31
PD 100-38/2 22 43.7 44.5 44.2 43.8 42.5 40.5 38 36.4 35
PD 100-52/2 30 55 55.8 55.9 55.9 55.5 55 53.6 52 50.9
PD 100-60/2 37 62 62.9 63.3 63.2 63 62 60.6 60 57.6
H
(m)
-
8/19/2019 Swisspump Pd 60hz
26/36
T e c h n i c a l
D a t a
26
PD125-**/4
PD 125
-
8/19/2019 Swisspump Pd 60hz
27/3627
PD125-**/4
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2PD 125-11/4 200 260 208 216 176 230 215 228 873 620 310 166
PD 125-14/4 200 260 208 216 176 230 215 228 873 620 310 169
PD 125-20/4 350 330 255 272 248 230 215 298 1003 800 400 320
PD 125-24/4 350 330 255 272 248 230 215 298 1003 800 400 330
PD 125-28/4 350 330 255 272 248 230 215 298 1063 800 400 349
PD 125-32/4 350 330 255 272 248 230 215 298 1103 800 400 384
PD 125-38/4 400 400 310 272 248 230 215 299 1174 800 400 444
PD 125-40/4 450 450 325 272 248 230 215 314 1189 800 400 499
PD 125-46/4 450 450 325 272 248 230 215 314 1214 800 400 536
Model(mm) Weight
(KG)
Model (Kw) Q(m³/h) 20 40 60 80 100 120 140 150 160 180 200 220
PD 125-11/4 5.5 12.9 12.7 12.6 12.2 11.6 11 10 9
PD 125-14/4 7.5 16.2 16.1 16 15.9 15.3 14 13.8 12.5
PD 125-20/4 11 21.75 21.4 21.2 21 20.6 20 18 16.4 14.5
PD 125-24/4 15 26.2 25.9 25.7 25.5 24.8 24 22.9 21.2 19.8
PD 125-28/4 18.5 30.4 30.2 30.1 29.9 29.4 28.6 28 26.6 24.5 22.5
PD 125-32/4 22 35.2 34.9 34.8 34.5 34.2 33.5 32.7 32 31.3 30.1 27.8
PD 125-38/4 30 40.2 40.1 40 39.9 39.8 39.5 38.6 38 37.8 36.2 33.8
PD 125-40/4 37 42.6 42.8 42.9 42.7 42.4 41.9 41.3 40.7 40 38.9 37.4
PD 125-46/4 45 47.2 47.4 47.6 47.7 47.6 47.5 47.2 46.7 46 45.1 44.1
H
(m)
-
8/19/2019 Swisspump Pd 60hz
28/36
T e c h n i c a l
D a t a
28
PD150-**/4
PD 150
-
8/19/2019 Swisspump Pd 60hz
29/3629
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2PD 150-15/4 350 315 250 238 208 230 215 269 974 800 400 280
PD 150-18/4 350 315 250 238 208 230 215 269 1014 800 400 300
PD 150-20/4 350 360 275 238 208 230 215 269 1064 800 400 336
PD 150-24/4 350 360 275 238 208 230 215 269 1104 800 400 352
PD 150-32/4 400 400 305 238 208 230 215 269 1134 800 400 403
PD 150-36/4 450 450 325 267 248 230 230 288 1188 900 450 508
PD 150-44/4 450 450 325 267 248 230 230 288 1213 900 450 545
Model (mm) Weight
(KG)
Model (Kw) Q(m³/h) 30 60 90 120 140 160 180 200 220 240
PD 150-15/4 11 19.1 18.4 17.6 16.7 15.9 15.0 14.1 12.7 10.5
PD 150-18/4 15 21.6 21.3 20.8 20.1 19.5 18.8 18.0 16.9 15.4 12.6
PD 150-20/4 18.5 24.0 23.6 23.3 22.9 22.4 21.7 20.9 20.0 18.9 17.4
PD 150-24/4 22 27.0 27.2 27.1 26.8 26.3 25.8 24.9 24.0 22.8 21.5
PD 150-32/4 30 34.2 34.4 34.6 34.4 34.0 33.5 32.8 32.0 30.9 29.4
PD 150-36/4 37 39.7 39.3 38.8 38.2 37.8 37.3 36.7 36.0 34.9 33.6
PD 150-44/4 45.0 47.3 47.4 47.2 46.8 46.4 45.8 45.0 44.0 42.9 41.7
H
(m)
PD150-**/4
-
8/19/2019 Swisspump Pd 60hz
30/36
T e c h n i c a l
D a t a
30
PD200-**/4
PD 200
-
8/19/2019 Swisspump Pd 60hz
31/3631
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD 200-12.5/4 350 360 280 278 219 360 270 415 1285 1000 500 431
PD 200-20/4 400 400 305 278 219 360 270 415 1335 1000 500 490
PD 200-23/4 450 450 335 303 252 360 270 445 1395 1100 550 600
PD 200-27/4 450 450 335 303 252 360 270 445 1420 1100 550 636
PD 200-32/4 550 490 365 303 252 360 270 445 1505 1100 550 707
PD 200-43/4 550 550 400 315 269 360 270 457 1587 1100 550 880
PD 200-50/4 550 550 400 315 269 360 270 457 1637 1100 550 971
Model (mm) Weight
(KG)
Model (Kw) Q(m³/h) 160 200 240 280 320 360 400 440
PD 200-12.5/4 22 17.4 17.1 16.7 16.0 15.2 14.1 12.5 10.0
PD 200-20/4 30 25.1 24.8 24.3 23.8 23.0 21.8 20.0 17.5
PD 200-23/4 37 28.8 28.6 28.3 27.6 26.6 25.1 23.0 20.3
PD 200-27/4 45 32.8 32.4 31.8 31.0 30.0 28.7 27.0 24.6
PD 200-32/4 55 37.8 37.4 36.8 36.1 35.1 33.8 32.0 29.5
PD 200-43/4 75 47.7 47.4 47.1 46.6 45.9 44.8 43.0 40.0
PD 200-50/4 90 53.2 52.9 52.7 52.4 52.0 51.4 50.0 47.6
H
(m)
PD200-**/4
-
8/19/2019 Swisspump Pd 60hz
32/36
T e c h n i c a l
D a t a
32
PD250-**/4
PD 250
-
8/19/2019 Swisspump Pd 60hz
33/3633
Size, weight, and volume for transportation
Performance Table
D B1 B2 B3 B4 B5 H1 H2 H3 L1 L2
PD 250-14/4 450 450 335 316 243 390 300 495 1475 1100 550 610
PD 250-17/4 450 450 335 316 243 390 300 495 1500 1100 550 647
PD 250-20/4 550 490 365 316 243 390 300 495 1585 1100 550 720
PD 250-26/4 550 550 400 329 264 440 300 507 1667 1100 550 906
PD 250-32/4 550 550 400 329 264 440 300 507 1717 1100 550 997
PD 250-40/4 660 625 555 347 292 440 305 525 1860 1200 600 1386
PD 250-50/4 660 625 555 347 292 440 305 525 1910 1200 600 1469
Model (mm) Weight
(KG)
Model (Kw) Q(m³/h) 240 300 360 420 480 540 600 630 660 720PD 250-14/4 37 19.6 19.1 18.4 17.7 16.8 15.9 14.7 14.0 14.0 11.6
PD 250-17/4 45 22.5 22.1 21.4 20.7 19.9 18.9 17.6 17.0 17.0 14.4
PD 250-20/4 55 25.8 25.2 24.5 23.7 22.9 21.9 20.7 20.0 20.0 17.6
PD 250-26/4 75 33.3 32.5 31.5 30.6 29.5 28.2 26.8 26.0 26.0 23.1
PD 250-32/4 90 38.9 38.2 37.3 36.3 35.5 34.2 32.8 32.0 32.0 29.3
PD 250-40/4 110 46.4 45.8 45.2 44.4 43.6 42.4 40.9 40.0 40.0 36.5
PD 250-50/4 132 56.1 55.7 55.1 54.4 53.6 52.5 50.9 50.0 50.0 46.3
H
(m)
PD250-**/4
-
8/19/2019 Swisspump Pd 60hz
34/36
-
8/19/2019 Swisspump Pd 60hz
35/36
-
8/19/2019 Swisspump Pd 60hz
36/36
www.swisspump.com
Swiss Pump Company AG
Moosweg 36
CH - 3645 Thun - Gwatt
Switzerland
Tel. +41 33 223 11 00
Fax +41 33 223 11 22