system description acrowall-es - basf · 2018. 11. 6. · kick-out flashing detail system...

16
Acrowall-ES Class PB EIFS incorporating a primary moisture barrier Typical Details 1. ACROWALL-ES SYSTEM APPLICATION (PLAN VIEW) 2. ACROWALL-ES SYSTEM APPLICATION (ISOMETRIC VIEW) 3. AESTHETIC GROOVE (PLAN VIEW) 4. INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS 5. WINDOW HEAD (FLUSH) 6. WINDOW HEAD (RECESSED) 7. WINDOW JAMB (FLUSH) (PLAN VIEW) 8. WINDOW JAMB (RECESSED) (PLAN VIEW) 9. WINDOW SILL (FLUSH) 10. WINDOW SILL (RECESSED) 11. ROOF EDGE FLASHING 12. METAL COPING 13. PARAPET EPS CAP DETAIL 14. EXPANSION JOINT DETAIL AT FLOORLINE OF WOOD FRAME CONSTRUCTION 15. EXPANSION JOINT AT CHANGE IN SUBSTRATE 16. TERMINATION AT SOFFIT/GABLE END 17. EXPANSION JOINT DETAIL (PLAN VIEW) 18. PIPE PENETRATION 19. CORNER MESH APPLICATION WITH HI-IMPACT 20 (PLAN VIEW) 20. CORNER MESH APPLICATION WITH ACROMESH TM 4, INTERMEDIATE 6 OR 12 (PLAN VIEW) 21. LIGHT FIXTURE 22. TERMINATION AT FOUNDATION 23. TERMINATION AT FOUNDATION (FLUSH) 24. KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763

Upload: others

Post on 26-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

Acrowall-ESClass PB EIFS incorporating a primary moisture barrier

Typical Details

1. ACROWALL-ES SYSTEM APPLICATION (PLAN VIEW)

2. ACROWALL-ES SYSTEM APPLICATION (ISOMETRIC VIEW)

3. AESTHETIC GROOVE (PLAN VIEW)

4. INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS

5. WINDOW HEAD (FLUSH)

6. WINDOW HEAD (RECESSED)

7. WINDOW JAMB (FLUSH) (PLAN VIEW)

8. WINDOW JAMB (RECESSED) (PLAN VIEW)

9. WINDOW SILL (FLUSH)

10. WINDOW SILL (RECESSED)

11. ROOF EDGE FLASHING

12. METAL COPING

13. PARAPET EPS CAP DETAIL

14. EXPANSION JOINT DETAIL AT FLOORLINE OF WOOD FRAME CONSTRUCTION

15. EXPANSION JOINT AT CHANGE IN SUBSTRATE

16. TERMINATION AT SOFFIT/GABLE END

17. EXPANSION JOINT DETAIL (PLAN VIEW)

18. PIPE PENETRATION

19. CORNER MESH APPLICATION WITH HI-IMPACT 20 (PLAN VIEW)

20. CORNER MESH APPLICATION WITH ACROMESHTM 4, INTERMEDIATE 6 OR 12 (PLAN VIEW)

21. LIGHT FIXTURE

22. TERMINATION AT FOUNDATION

23. TERMINATION AT FOUNDATION (FLUSH)

24. KICK-OUT FLASHING DETAIL

SYSTEM DESCRIPTION1033763

Page 2: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

2. TYPICAL ACROWALL-ES SYSTEM APPLICATION (ISOMETRIC VIEW)

1. TYPICAL ACROWALL-ES SYSTEM APPLICATION (PLAN VIEW)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE BASE COAT

ACROCRETE REINFORCING MESH

ACROCRETE FINISH COAT

Page 3: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

4. TYPICAL INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS

3. TYPICAL AESTHETIC GROOVE (PLAN VIEW)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

AESTHETIC GROOVE

ACROCRETE® INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

ACROCRETE INSULATION BOARD

STAGGER INSULATION BOARD JOINTS AT CORNER OF OPENINGS

WRAP ACROCRETE BASE COAT AND ACROMESHTM 4 WRAP ACROCRETE BASE COAT AND ACROMESHTM 4 REINFORCING MESH AT INSULATION BOARD EDGESREINFORCING MESH AT INSULATION BOARD EDGES

ACROMESH 4 REINFORCING MESHEMBEDDED IN ACROCRETE BASE COATEMBEDDED IN ACROCRETE BASE COAT

NOTE: • TYPICAL AT WINDOWS, DOORS, ETC.• MAINTAIN A MIN. 13 MM (1/2”) PERIMETER SEALANT JOINT• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS

305 M

M (12”

)

305 M

M (12”

)

229 MM (9”)

229 MM (9”)

Page 4: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCOTE® T

BACKER ROD AND SEALANT

WINDOW

6. TYPICAL WINDOW HEAD (RECESSED)

5. TYPICAL WINDOW HEAD (FLUSH)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCOTE® T

BACKER ROD AND SEALANT

WINDOW

Page 5: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCOTE® T

BACKER ROD AND SEALANT

WINDOW

8. TYPICAL WINDOW JAMB DETAIL (RECESSED) (PLAN VIEW)

7. TYPICAL WINDOW JAMB DETAIL (FLUSH) (PLAN VIEW)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCOTE® T

BACKER ROD AND SEALANT

WINDOW

Page 6: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

WINDOW

BACKER ROD AND SEALANT

ACROCOTE® T

FRAMING

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

10. TYPICAL WINDOW SILL DETAIL (RECESSED)

9. TYPICAL WINDOW SILL DETAIL (FLUSH)

WINDOWNOTE:• EXTEND FLASHING MIN. OF • 50 MM (2”) OVER EIFS• FLASHINGS ARE BY OTHERS • AND SHALL BE AS PER DESIGN/ • CODE REQUIREMENTS

PAN FLASHING

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

SEALANT

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

Page 7: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

12. TYPICAL METAL COPING DETAIL

11. TYPICAL ROOF EDGE FLASHING DETAIL

ROOF SYSTEM

ROOF EDGE FLASHING

SEALANT

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

ROOF SYSTEM

ROOF EDGE FLASHING

SEALANT

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

MIN. 50 MM (2”)

MIN. 50 MM (2”)

Page 8: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

14. TYPICAL EXPANSION JOINT DETAIL AT FLOORLINE WOOD-FRAME CONSTRUCTION

13. TYPICAL EPS PARAPET CAP DETAIL

NOTEFLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS.

EPS CAP

FRAMING

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

ROOF SYSTEM

TYPICAL WOOD FRAMING

ACCEPTABLE SHEATHING

BACKER ROD AND SEALANT

ACROCOTE® T

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

MIN. 19 MM (3/4”)

Page 9: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

16. TYPICAL TERMINATION AT SOFFIT/GABLE END

15. TYPICAL EXPANSION JOINT AT CHANGE IN SUBSTRATE

FRAMING

MASONRY

ACCEPTABLE SHEATHING

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

BACKER ROD AND SEALANTNOTE:JOINT WIDTH PER DESIGN

ACROCOTE® T

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

FRAMING

ACCEPTABLE SHEATHING

BLOCKING

SOFFIT

TRIM

FRIEZE BOARD

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

MIN. 50 MM (2”)MIN. 50 MM (2”)

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCRETE BASE COAT

Page 10: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

18. TYPICAL PIPE PENETRATION

17. TYPICAL EXPANSION JOINT DETAIL (PLAN VIEW)

FRAMING

ACCEPTABLE SHEATHING

ACROCOTE® T

BACKER ROD AND SEALANT

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

TYPICAL WOOD FRAMING

ACCEPTABLE SHEATHING

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCRETE INSULATION BOARD

BACKER ROD AND SEALANT

ACROCOTE T

ACROCRETE BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

MIN. 13 MM (1/2”) MIN. 13 MM (1/2”)

WIDTH PER DESIGN

Page 11: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

20. TYPICAL CORNER MESH APPLICATION WITH ACROMESH 4, INTERMEDIATE 6 OR 12 (PLAN VIEW)

19. TYPICAL CORNER MESH APPLICATION WITH HI-IMPACT 20 (PLAN VIEW)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

HI-IMPACT 20 EMBEDDED IN ACROCRETE BASE COAT

ACROMESHTM 4 OR INTERMEDIATE 6 EMBEDDED IN ACROCRETE BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

CORNER MESH EMBEDDED IN BASE COAT

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROMESH 4, INTERMEDIATE 6 OR 12 EMBEDDED IN ACROCRETE BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

CORNER MESH EMBEDDED IN BASE COAT

NOTE: A CONTINUOUS OVERLAY OF ACROMESH 4, INTERMEDIATE 6 OR 12 IS REQUIRED OVER CORNER MESH

NOTE: • BUTT EDGE OF HI-IMPACT 20 TO CORNER MESH• A CONTINUOUS OVERLAY • OF ACROMESH 4 OR • INTERMEDIATE 6 IS REQUIRED OVER HI-IMPACT 20 OR • CORNER MESH

Page 12: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

ACROWALL-ES DETAILS

22. TYPICAL TERMINATION AT FOUNDATION

21. TYPICAL LIGHT FIXTURE

ACROCRETE INSULATION BOARD

FRAMING

ACCEPTABLE SHEATHING

WRAP BASE COAT AND ACROCRETE® REINFORCING MESH

SET FLANGE IN SEALANT

SMALL LIGHT FIXTURE

ACROCRETE BASE COAT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

SEALANT AND BOND BREAKER

NOTE: • GRADE SHALL BE PITCHED • FOR POSITIVE DRAINAGE• TERMINATE SYSTEM 203 MM (8”) • MIN. ABOVE GRADE

WIRE OPENINGWIRE OPENING

MIN. 50 MM (2”)MAX. 305 MM (12”)

Page 13: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others

24. TYPICAL KICK-OUT FLASHING DETAIL

23. TYPICAL TERMINATION AT FOUNDATION (FLUSH)

FRAMING

ACCEPTABLE SHEATHING

ACROCRETE® BASE COAT

ACROCRETE INSULATION BOARD

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

WRAP BASE COAT AND ACROCRETE REINFORCING MESH

ACROCOTE® T

BACKER ROD AND SEALANT

FOUNDATION

ACCEPTABLE SHEATHING

STEP FLASHING

ACROWALL-ES SYSTEM

BACKER ROD AND SEALANT

ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT

MIN. 25 MM (1”)

NOTE:• KICK-OUT FLASHING MUST BE ANGLED 100˚ MIN. TO ALLOW FOR PROPER DRAINAGE.

• KICK-OUT FLASHING SEAMS MUST BE • KICK-OUT FLASHING SEAMS MUST BE SOLDERED OR SEALED WITH SOLDERED OR SEALED WITH APPROPRIATE SEALANT.

• TERMINATE ACROWALL-ES SYSTEM • TERMINATE ACROWALL-ES SYSTEM MIN. 50 MM (2”) ABOVE ROOF. MIN. 50 MM (2”) ABOVE ROOF.

BUILDING PAPERBUILDING PAPER

ROOF SHINGLESROOF SHINGLES

DRIP EDGE

KICK-OUT FLASHINGKICK-OUT FLASHING

MIN. 13 MM (1/2”)

Page 14: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTES

Page 15: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

NOTES

Page 16: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes

RESIDENTIAL POLICYOn one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction with-out expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.]

Consult BASF Wall Systems’ Technical Services Department for specific recom-mendations concerning all other applications. Consult the Acrocrete web-site, www.acrocrete.com for additional information about products and systems and for updated literature.

DISCLAIMERThis information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON-SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used.

BASF Wall Systems | 3550 St. Johns Bluff Road South Jacksonville, FL 32224-2614 P: 800.221.9255 F: 904. 996.6300 www.acrocrete.com©2006 BASF Printed in U.S.A. 11/06