t25001en.pdf

4
Selection Guide for Pressure Regulators Associated Information Sheet T 2500 EN Edition November 2012 Information Sheet T 2500-1 EN

Upload: catalin-stan

Post on 01-Oct-2015

214 views

Category:

Documents


1 download

TRANSCRIPT

  • Selection Guide for Pressure Regulators

    Associated Information Sheet T 2500 EN Edition November 2012

    Information Sheet T 2500-1 EN

  • Self-operated Regulators

    Pressure Regulators

    Selection guide Part 1

    2 T 2500-1 EN

    Pressure regulators for ... The SAMSON range includes the following regulators

    Processing plants

    Cryogenic service

    Industrial energy transfer networks (inc. air) (steam)

    Heating, ventilation and air-conditioning

    District heating

    Food processing and pharmaceuticalindustries, FDA-compliant

    Free of non-ferrous metal Possible

    Stainless steel /possible /possible

    Typetested Safety version

    Pressure reducing valves

    Excess pressure valves

    Safety valve and pressure limiterwith/without pressure regulator

    Pressure build-up regulator andexcess pressure valve

    Type 2405/Type 2407See T 2520 EN/T 2524 EN

    Type 41-23 2)

    See T 2512 EN

    Type 44-0 B 2)

    See T 2628 EN

    Type 44-1 B 2)

    See T 2626 EN

    Type 44-6 B 2)

    See T 2626 EN

    Type M 44-7 2)

    See T 2532 EN

    Type 2434 1)

    See T 2504 EN

    Type 2406/Type 2408See T 2522 EN/T 2528 EN

    1) With external supply of compressed air for set point adjustment2) Special version available with external air supply for set point adjustment

    Type 41-73 2)See T 2517 EN

    Type M 44-2 2)

    See T 2530 EN

  • Selection guide Part 2

    3 T 2500-1 EN

    Possible Possible

    /possible Possible Possible

    TV-typetested

    Type 44-4 (SEV)See T 2632 EN

    Type 2371-00See T 2642 EN

    Type 2334(pressure reducing valve)See T 3210 EN

    Type 2334(excess pressure valve)See T 3210 EN

    Type 33-1 (SSV)See T 2551 EN

    Type 36-3 (SSV)See T 2546 EN

    Type 44-3 (SSV)See T 2623 EN

    Type 44-9 (SSV)See T 2630 EN

    Type 2401See T 2519 EN

    Type 44-8 (SEV)See T 2723 EN

    Type 33-7 (SEV)See T 2551 EN Type 36-8 (SEV)

    See T 2546 EN

    Type 2333See T 2552 EN

    Type 2422/2424See T 2547 EN

    Type 2422/2425See T 2549 EN

    Type 2335See T 2552 EN

    Type 2371-11See T 2640 EN

  • Selection guide Part 3

    T 2500-1 EN

    SAMSON AG MESS- UND REGELTECHNIKWeismllerstrae 3 60314 Frankfurt am Main GermanyPhone: +49 69 4009-0 Fax: +49 69 4009-1507Internet: http://www.samson.de 20

    12-1

    1

    Pressure regulators for ... The SAMSON range includes the following regulators

    Processing plants

    Cryogenic service

    Industrial energy transfer networks (inc. air)

    Heating, ventilation and air-conditioning

    District heating

    Food processing and pharmaceuticalindustries, FDA-compliance

    Free of non-ferrous metal

    Stainless steel /possible

    Typetested Safety version TV-typetested

    Corrosive media

    Pressure reducing valves

    Excess pressure valves

    Safety valve and pressure limiterwith/without pressure regulator

    Pressure build-up regulator andexcess pressure valve

    Type 2357-11See T 2560

    Type 2357-21See T 2560

    Type 44-2See T 2623

    Type 50 ES/EMSee T 2555 EN

    Type 44-7See T 2723 EN

    Type 2357-1, Type 2357-6See T 2557 EN

    Type 2357-7, Type 2357-2See T 2557 EN

    Type 2357-3See T 2559 ENType 2357-31See T 2558 ENType 2357-11/-21See T 2560 EN

    Type 2375See T 2536 EN

    Type 2373See T 2534 EN

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 250 /GrayImageMinResolutionPolicy /Warning /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.33000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1000 /MonoImageMinResolutionPolicy /Warning /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check true /PDFXCompliantPDFOnly true /PDFXNoTrimBoxError false /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition (ISO Coated \050Prozess-Standard Offset, gestrichenes Papier, 60 L/cm, ISO 12647-2:2004\051) /PDFXRegistryName () /PDFXTrapped /False

    /CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /UseDocumentProfile /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice